The following is a list of changes to the ST4079, pages 10 and 11. Page 10: gate loc input from to NA5 PA027 E XMONOEN (PB050-XQ) MONOEN (PB050-Q) NA5 PA034 D MONOEN (PB050-Q) XMONOEN (PB050-XQ) Page 11: delete gates PB016 and PB032 gate loc input from to NO3 PB005 A OLDENN (PB016-O) OLDEN (PB022-Q) NO3 PB008 B OLDENN (PB016-O) OLDEN (PB022-Q) NO3 PB014 B OLDENN (PB016-O) OLDEN (PB022-Q) NO4 PB023 C OLDENN (PB016-O) OLDENN (PB022-XQ) NO4 PB031 C OLDENN (PB016-O) OLDENN (PB022-XQ) NO4 PB042 D OLDENN (PB016-O) OLDENN (PB022-XQ) NA5 PB007 A XXAI0 (PB032-O) (PB034-O) NA4 PB013 D XXAI0 (PB032-O) (PB034-O) NO4 PB031 B XXAI0 (PB032-O) (PB034-O) Label "OLDENN" is now obtained from PB022-XQ instead of PB016-O All inputs connected to PC032-O should be connected to PB034-O