Advance Information MC68901 MULTI-FUNCTION PERIPHERAL JANUARY, 1984 This document contains information on a new product. Specifications and information herein ©MOTOROLA INC., 1984 ADI-984 are s4bject to change without notice. Motorola reserves the right to make changes to any products herein to improve reliability, function or design. Motorola does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. TABLE OF CONTENTS Paragraph Page Number Title Number Section 1 Introduction Section 2 Signal and Bus Operation Description 2.1 Signal Description ................................................. . 2-1 2.1.1 VCC and GND .................................................. . 2-2 2.1.2 Clock (ClK) .................................................... . 2-2 2.1.3 Asynchronous Bus Control ....................................... . 2-2 2.1.3.1 Chip Select (CS) .............................................. . 2-2 2.1.3.2 Data Strobe (DS) ............................................. . 2-2 2.1.3.3 Read/Write (R/W) ............................................ . 2-2 2.1.3.4 Data Transfer Acknowledge (DTACK) ............................ . 2-2 2.1.3.5 Register Select Bus (RS1 Through RS5) ......................... . 2-2 2.1.3.6 Data Bus (DO Through D7) ...................................... . 2-2 2.1.3.7 Reset (RESET) ................................................ . 2-3 2.1.4 Interrupt Control ................................................ . 2-3 2.1.4.1 Interrupt Request (IRQ) ........................................ . 2-3 2.1.4.2 Interrupt Acknowledge (lACK) .................................. . 2-3 2.1.4.3 Interrupt Enable In CfED ......................................... . 2-3 2.1.4.4 Interrupt Enable Out (lEO) ...................................... . 2-3 2.1.5 General Purpose I/O Interrupt Lines (10 Through 17) .................. . 2-3 2.1.6 Timer Control ................................................... . 2-4 2.1.6.1 Timer Clock (XT Al 1 and XT Al2) ................................ . 2-4 2.1.6.2 Timer Inputs (TAl and TBI) ..................................... . 2-4 2.1.6.3 Timer Outputs (TAO, TBO, TCO, and TDO) ....................... . 2-4 2.1.7 Serial 1/ 0 Control ............................................... . 2-4 2.1.7.1 Serial Input (S I) ............................................... . 2-4 2.1.7.2 Serial Output (SO) ............................................ . 2-4 2.1.7.3 Receiver Clock (RC) ........................................... . 2-5 2.1.7.4 Transmitter Clock (TCi ......................................... . 2-5 2.1.8 DMA Control ................................................... . 2-5 2.1.8.1 Receiver Ready (RR) ........................................... . 2-5 2.1.8.2 Transmitter Ready (TR) ........................................ . 2-5 2.1.9 Signal Summary ................................................ . 2-5 2.2 Bus Operation .................................................... . 2-6 2.2.1 Data Transfer Operations ......................................... . 2-6 iii TABLE OF CONTENTS ( Continued) Paragraph Page Number Title Number 2.2.1.1 Read Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2.2.1.2 Write Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2.2.2 Interrupt Acknowledge Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2.2.3 Reset Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Section 3 Interrupt Structure 3.1 Interrupt Processing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.1.1 Interrupt Channel Prioritization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.1.2 Interrupt Vector Number Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3.2 Daisy-Chaining MFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3.3 Interrupt Control Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3.3.1 Interrupt Enable Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3.3.2 Interrupt Pending Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3.3.3 Interrupt Mask Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3.4 Nesting MFP Interrupts ............................................. 3-6 3.4.1 Selecting The End-Of-Interrupt Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3.4.2 Automatic End-Of-Interrupt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3.4.3 Software End-Of-Interrupt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Section 4 General Purpose Input/Output Interrupt Port 4.1 M6800 Interrupt Controller ..................... '. . . . . . . . . . . . . . . . . . . . . . 4-1 4.2 GPIP Control Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.2.1 GPIP Data Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.2.2 Active Edge Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.2.3 Data Direction Register ........................................... 4-2 Section 5 Timers 5.1 Operation Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.1.1 Delay Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.1.2 Pulse Width Measurement Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5.1.3 Event Count Mode Operation ............. . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 5.2 Timer Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 5.2.1 Timer Data Hegisters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 5.2.2 Timer Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 Section 6 Universal Synchronous/Asynchronous Receiver-Transmitter 6.1 Character Protocols ......................... ;...................... 6-1 6.1.1 Asynchronous Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6.1.2 Synchronous Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 iv TABLE OF CONTENTS ( Concluded) Paragraph Page Number Title Number 6.1.3 USART Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 6.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 6.2.1 Receiver Interrupt Channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 6.2.2 Receiver Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 6.2.3 Special Receive Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 6.3 Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 6.3.1 Transmitter Interrupt Channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 6.3.2 Transmitter Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 6.4 DMA Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Section 7 Electrical Characteristics 7.1 Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7.2 Thermal Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7.3 Power Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7.4 DC Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 7.5 Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 7.6 Clock Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 7.7 AC Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 7.8 Timer AC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5 Section 8 Mechanical Data and Ordering Information 8.1 Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 8.2 Package Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 8.3 Ordering Information ............................................... 8-3 v LIST OF ILLUSTRATIONS Figure Page Number Title Number 1-1 MFPBlockDiagram ................................................ 1-1 2-1 Input and Output Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 Read Cycle Timing ................................................. 2-6 2-3 Write Cycle Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2-4 lACK Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 3-1 Interrupt Vector Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-2 Vector Register Format (VR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-3 Daisy-Chained Interrupt Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-4 Interrupt Control Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 4-1 GPIP Control Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 5-1 Conceptual Circuit of Timers A and B in Pulse Width Measurement Mode. . . 5-2 5-2 Timer Data Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 5-3 Timer Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 6-1 Synchronous Character Register (SCR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 6-2 USART Control Register (UCR) ...................................... 6-3 6-3 Receiver Status Register (RSR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 6-4 Transmitter Status Register (TSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 7-1 IRQ Test Load ..................................... , ... .. ......... . 7-2 7-2 Typical Test Load .................................................. 7-2 7-3 MFP External Oscillator Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 7-4 Read Cycle Timing ................................................. Foldout 1 7-5 Write Cycle Timing ................................................. Foldout 2 7-6 Interrupt Acknowledge Cycle (jET Low) ................................ Foldout 3 7-7 Interrupt Acknowledge Cycle (lET High) ................................ Foldout 4 vi LIST OF TABLES Table Page Number Title Number 1-1 M FP Register Map. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 1-2 2-1 Signal Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 3-1 Interrupt Channel Prioritization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 vii/viii SECTION 1 INTRODUCTION The MC68901 multi-function peripheral (MFP) is a member of the M68000 Family of peripherals. The MFP directly interfaces to the MC68000 processor via an asynchronous bus structure. Both vectGred and polled interrupt schemes are supported, with the M FP providing unique vector number generation for each of its 16 interrupt sources. Additionally, handshake lines are provided to facilitate DMAC interfacing. Refer to Figure 1-1 for a block diagram of the MC68901. ClK RESET TCO TDO XTAl1 Data XTAL2 (8) TAO Register TAl Select TBO (5) CPU TBI Bus CS I/O RR R/W SI RC USART DS SO TC DTACK TR General Purpose I/O-Interrupts 10-17 Figure 1-1. MFP Block Diagram 1-1 The MC68901 performs many of the functions common to most microprocessor-based systems. T~e resources available to the user include: • Eight Individually Programmable I/O Pins with Interrupt Capability • 16-Source Interrupt Controller with Individual Source Enabling and Masking • Four Timers, Two of which are Multi-Mode Timers • Timers May Be Used as Baud Rate Generators for the Serial Channel • Single-Channel Full-Duplex Universal Synchronous/ Asynchronous Receiver-Transmitter (USART) that Supports Asynchronous and with the Addition of a Polynomial Generator Checker Supports Byte Synchronous Formats By incorporating multiple functions within the MFP, the system designer retains flexibility while minimizing device count. From a programmer's point of view, the versatility of the MFP may be attributed to its register set. The registers are well organized and allow the M FP to be easily tailored to a variety of applications. All of the 24 registers are also directly addressable which simplifies programming. The register map is shown in Table 1-1. Table 1-1. MFP Register Map Address Binary Hex RS5 RS4 RS3 RS2 RSl Abbreviation Register Name 01 0 0 0 0 0 GPIP General Purpose 1/0 Register 03 0 0 0 0 1 AER Active Edge Register 05 0 0 0 1 0 DDR Data Direction Register 07 0 0 0 1 1 IERA Interrupt Enable Register A 09 0 0 1 0 0 IERB Interrupt Enable Register B OB 0 0 1 0 1 IPRA Interrupt Pending Register A OD 0 0 1 1 0 IPRB Interrupt Pending Register B OF 0 0 1 1 1 ISRA Interrupt In-Service Register A 11 0 1 0 0 0 ISRB Interrupt In-Service Register B 13 0 1 0 0 1 IMRA Interrupt Mask Register A 15 0 1 0 1 0 IMRB Interrupt Mask Register B 17 0 1 0 1 1 VR Vector Register 19 0 1 1 0 0 TACR Timer A Control Register 1B 0 1 1 0 1 TBCR Timer B Control Register 10 0 1 1 1 0 TCDCR Timers C and D Control Register 1F 0 1 1 1 1 TADR Timer A Data Register 21 1 0 0 0 0 TBDR Timer B Data Register 23 1 0 0 0 1 TCDR Timer C Data Register 25 1 0 0 1 0 TDDR Timer D Data Register 27 1 0 0 1 1 SCR Synchronous Character Register 19 1 0 1 0 0 UCR USART Control Register 2B 1 0 1 0 1 RSR Receiver Status Register 2D 1 0 1 1 0 TSR Transmitter Status Register 2F 1 0 1 1 1 UDR USART Data Register NOTE: Hex addresses assume that RS1 connects with A 1, RS2 connects with A2, etc. and that DS is connected to LDS on the MC68000 or DS is connected to DS on the MC68008. 1-2 SECTION 2 SIGNAL AND BUS OPERATION DESCRIPTION This section contains a brief description of the input and output signals. A discussion of bus opera- tion during the various operations is also presented. NOTE The terms assertion and negation will be used extensively. This is done to avoid confu- sion when dealing with a mixture of "active low" and "active high" signals. The term assert or assertion is used to indicate that a signal is active or true, independent of whether that level is represented by a high or low voltage. The term negate or negation is used to indicate that a signal is inactive or false. 2.1 SIGNAL DESCRIPTION The input and output signals can be functionally organized into the groups shown in Figure 2-1. The following paragraphs provide a brief description of the signal and a reference (if applicable) to other sections that contain more detail about its function. 10-17 VCC TAl GND TBI ClK TAO TBO Timer CS TCO Control OS TOO R/W MFP XTAll DTACK XTAL2 RS1-RS5 RESET SO 51 I Serial liD r RC Control RO TC Interrupt lACK Control . iEi lEO TR } DMA RR Control Figure 2-1. Input and Output Signals 2-1 2.1.1 VCC and GND These inputs supply power to the MFP. The VCC is power at + 5 volts and GND is the ground connection. 2.1.2 Clock (ClK) The clock input is a single-phase TTL-compatible signal used for internal timing. This input should not be gated off at any time and must conform to minimum and maximum pulse width times. The clock is not necessarily the system clock in frequency nor phase. 2.1.3 Asynchronous Bus Control Asynchronous data transfers are controlled by chip select, data strobe, read/write, and data transfer acknowledge. The low order register select lines, RS 1-RS5, select an internal MFP register for a read or write operation. The reset line initializes the MFP registers and the internal control signals. 2.1.3.1 CHIP SELECT (CS). This input activates the MFP for internal register access. 2.1.3.2 DATA STROBE (DS). This input is part of the internal chip select and interrupt acknowl- edge functions. The MFP must be located on the lower portion of the 16-bit data bus so that the vector number passed to the processor during an interrupt acknowledge cycle will be located in the low byte of the data word. As a result, DS must be connected to the processor's lower data strobe if vectored interrupts are to be used. Note that this forces all registers to be located at odd ad- dresses and latches data on the rising edge for writes. 2.1.3.3 READ/WRITE (R/W). This input defines a data transfer as a read (high) or a write (low) cycle. 2.1.3.4 DATA TRANSFER ACKNOWLEDGE (DTACK). This output signals the completion of the operation phase of a bus cycle to the processor. If the bus cycle is a processor read, the MFP asserts DTACK to indicate that the information on the data bus is valid. If the bus cycle is a pro- cessor to the MFP, DTACK acknowledges the acceptance of the data by the MFP. DTACK will be asserted only by an MFP that has CS or lACK (and lEi) asserted. 2.1.3.5 REGISTER SELECT BUS (RS1 THROUGH RS5). The lower five bits of the register select bus select an internal M FP register during a read or write operation. 2.1.3.6 DATA BUS (DO THROUGH D7). This bidirectional bus is used to receive data from or transmit data to the M FP' s internal registers during a processor read or write cycle. During an inter- rupt acknowledge cycle, the data bus is used to pass a vector number to the processor. Since the MFP is an 8-bit peripheral, the MFP could be located on either the upper or lower portion of the 16-bit data bus (even or odd address). However, during an interrupt acknowledge cycle, the vector number passed to the processor must be 10cateGf in the low byte of the data word. As a result, DO-D7 of the M FP must be connected to the low order eight bits of the processor data bus, placing MFP registers at odd addresses if vectored interrupts are to be used. 2-2 2.1.3.7 RESET (RESET). This input will initialize the MFP during power up or in response to a total system reset. Refer to 2.2.3 Reset Operation for further information. 2.1.4 Interrupt Control The interrupt request and interrupt acknowledge signals are handshake lines for a vectored interrupt scheme. Interrupt enable in and the interrupt enable out implement a daisy-chained interrupt struc- ture. 2.1.4.1 INTERRUPT REQUEST (IRQ). This output signals the processor that an interrupt is pen- ding from the MFP. There are 16 interrupt channels that can generate an interrupt request. Clearing the interrupt pending registers (IPRA and IPRB) or clearing the interrupt mask registers (IMRA and IMRB) will cause IRQ to be negated. IRQ will also be negated as the result of an interrupt acknowledge cycle, unless additional interrupts are pending in the MFP. Refer to SECTION 3 INTERRUPT STRUCTURE for further information. 2.1.4.2 INTERRUPT ACKNOWLEDGE (lACK). If both IRQ and lEi are active, the MFP will begin an interrupt acknowledge cycle when lACK and OS are asserted. The MFP will supply a unique vector number to the processor which corresponds to the interrupt handler for the particular channel re- quiring interrupt service. In a daisy-chained interrupt structure, all devices in the chain must have a common lACK. Refer to 2.2.2 Interrupt Acknowledge Operation and 3.1.2 Interrupt Vector Number Format for addition.al information. 2.1.4.3 INTERRUPT ENABLE IN (iEi). This input, together with the lEO signal, provides a daisy- chained interrupt structure for a vectored interrupt scheme. lET indicates that no higher priority device is requesting interrupt service. So, the highest priority device in the chain should have its lET pin tied low. During an interrupt acknowledge cycle, an M FP with a pending interrupt is not allowed to pass a vector number to the processor until its lET pin is asserted. When the daisy-chain option is not implemented, all MFPs should have their lET pin tied low. Refer to 3.2 DAISY-CHAINING MFPs for additional information. 2.1.4.4 INTERRUPT ENABLE OUT (lEO). This output, together with the lET signal, provides a daisy-chained interrupt structure for a vectored interrupt scheme. The lEO of a particular MFP signals lower priority devices that neither the M FP nor any other higher-priority device is requesting interrupt service. When a daisy-chain is implemented, lEO is tied to the next lower priority device's iEi input. The lowest priority device's lEO is not connected. When the daisy-chain option is not im- plemented, lEO is not connected. Refer to 3.2 DAISY-CHAINING MFPs for additional information. 2.1.5 General Purpose I/O Interrupt Lines (10 Through 17) This is an 8-bit pin-programmable I/O port with interrupt capability. The data direction register (DDR) individually defines each line as either a high-impedance input or a TTL-compatible output. As an input, each line can generate an interrupt on the user selected transition of the input signal. Refer to SECTION 4 GENERAL PURPOSE I/O INTERRUPT PORT for further information. 2-3 2.1.6 Timer Control These lines provide internal timing and auxiliary timer control inputs required for certain operating modes. Additionally, the timer outputs are included in this group. 2.1.6.1 TIMER CLOCK (XTAL1 AND XTAL2). This input provides the timing signal for the four timers. A crystal can be connected between the timer clock inputs, XT AL 1 and XT AL2, or XT AL 1 can be driven with a TTL-level clock while XTAL2 is not connected. The following crystal parameters are suggested: a) Parallel resonance, fundamental mode AT-cut, ·HC6 or HC33 holder b) Frequency tolerance measured with 18 picofarads load (0.1 % accuracy) - drive level 10 microwatts c) Shunt capacitance equals 7 picofarads maximum d) Series resistance: 2.0 Asynchronous * 1 1 2 Asynchronous * Only used with divide-by-16 clock mode SET a) MPU writes a one CLEARED a) MPU writes a zero b) Reset PE Parity Enable. When this bit is zero, no parity check will be made and no parity bit will be computed for transmis- sion. When this bit is a one, parity will be checked by the receiver and parity will be calculated and inserted during data transmission. Note that parity is not automatically appended to the synchronous character for word lengths of less than eight bits. In this case, the parity should be written into the synchronous character register along with the synchronous word. SET a) MPU writes a one CLEARED a) MPU writes a zero b) Reset E/O Even/Odd Parity. When this bit is zero, odd parity is selected. When this bit is a one, even parity is selected. SET a) MPU writes a one CLEARED a) MPU writes a zero b) Reset Figure 6-2. USART Control Register (UCR) 6-3 6.2.1 Receiver Interrupt Channels The USART receive section is assigned two interrupt channels. One indicates the buffer fu'li condi- tion, while the other channel indicates an error condition. Error conditions include overrun, parity error, synchronous found, and break. These interrupting conditions correspond to the SF, OE, PE, and F/S or B bits of the receiver status register. These flags will function as described in 6.2.2 Receiver Status Register whether the receiver interrupt channels are enabled or disabled. While only one interrupt is generated per character received, two dedicated interrupt channels allow separate vector numbers to be assigned for normal and abnormal receiver conditions. When a received word has an error associated with it and the error interrupt channel is enabled, an interrupt will be generated on the error channel only. However, if the error channel is disabled, an interrupt for an error condition will be generated on the buffer full interrupt channel along with interrupts pro- duced by the buffer full condition. The receiver status register must always be read to determine which error condition produced the interrupt. 6.2.2 Receiver Status Register The receiver status register contains the receive buffer full flag, the synchronous strip enable, the receiver enable, and various status information associated with the data word in the receive buffer. The RSR is latched each time a data word is transferred to the receive buffer. RSR flags cannot change again until the data word has been read. The exception is the character in progress flag which monitors when a new word is being assembled in the asynchronous character format. The receiver status register is shown in Figure 6-3. F/S Address 2B I ~ BF ____ ~ OE ____ ~ PE ____ ~ FE or B _ _ _ _ _ _ L -_ _ _ _ ~ M/CIP SS _ _ _ _- L _ _ _ _ ~~ RE __ ~ BF Buffer Full. This bit is set when a received word is transferred to the receive buffer. This bit is cleared when the receive buffer is read by accessing the USART data register (UDR). This bit is read only. SET a) Received word transferred to buffer CLEARED a) Receive buffer read b) Reset OE Overrun Error. An overrun error occurs when a received word is due to be transferred to the receive buffer, but the receive buffer is full. Neither the receive buffer nor the RSR is overwritten. The OE bit is set after the receive buffer full condition is satisfied by reading the UDR. This error condition will generate an interrupt to the processor. The OE bit is cleared by reading the RSR. New data words will not be assembled until the RSR is read. SET a) Incoming word received and receive buffer full CLEARED a) Receiver status register read b) Reset PE Parity Error. This bit is set when the word transferred to the receive buffer has a parity error. This bit is cleared when the word transferred to the receive buffer does not have a parity error. SET a) Word in receive buffer has a parity error CLEARED a) Word in receive buffer does not have a parity error b) Reset FE Frame Error. A frame error exists when a non-zero data word is not followed by a stop bit in the asynchronous character format. The FE bit is set when the word transferred to the receive buffer has a frame error. The FE bit is cleared when the word transferred to the receive buffer does not have a frame error. SET a) Word in receive buffer has a frame error CLEARED a) Word in receive buffer does not have a frame error b) Reset Figure 6-3. Receiver Status Register (RSR) (Sheet 1 of 2) 6-4 F/S or B Found/Search or Break Detect. In the synchronous character format this bit can be set or cleared in software. When the bit is a zero, the USART receiver is placed in the search mode. The incoming data is compared to the syn- chronous character register (SCR) and the word length counter is disabled. The F/S bit will automatically be set when a match is found and the word length counter will be enabled. An interrupt will also be produced on the receive error channel. SET a) Incoming word matches synchronous character CLEARED a) MPU writes a zero b) Incoming word does not match synchronous character c) Reset In the asynchronous character format, this flag indicates a break condition. A break is detected when an all zero data word with no stop bit is received. The break condition continues until a non-zero data bit is received. The B bit is set when the word transferred to the receive buffer is a break indication. A break condition generates an interrupt to the processor. This bit is cleared when a non-zero data bit is received and the break condition has been acknowl- edged by reading the RSR at least once. An end of break interrupt will be generated when the bit is cleared. SET a) Word in receive buffer is a break CLEARED a) Break terminates and receiver status register read since beginning of break condition b) Reset M or CIP Match/Character in Progress. In the synchronous character format, this flag indicates that a synchronous character has been received. The M bit is set when the word transferred to the receive buffer matches the synchronous character register. The M bit is cleared when the word transferred to the receive buffer does not match the syn- chronous character register. SET a) Word transferred to receive buffer matches the synchronous character CLEARED a) Word transferred to receive buffer does not match synchronous character b) Reset In the asynchronous character format, this flag indicates that a word is being assembled. The CIP bit is set when a start bit is detected. The CIP bit is cleared when the final stop bit has been received. SET a) Start bit is detected CLEARED a) End of word detected b) Reset SS Synchronous Strip Enable. When this bit is a zero, data words that match the synchronous character register will not be loaded into the receive buffer and no buffer full condition will be produced. When this bit is a one, data words that match the synchronous character register will be transferred to the receive buffer and a buffer full condi- tion will be produced. SET a) MPU writes a one CLEARED a) MPU writes a zero b) Reset RE Receiver Enable. When this bit is a zero, the receiver will be immediately disabled. All flags will be cleared. When this bit is a one, normal receiver operation is enabled. This bit should not be set to a one until the receiver alock is active. SET a) MPU writes a one b) Transmitter is disabled in auto-turnaround mode CLEARED a) MPU writes a zero b) Reset Figure 6-3. Receiver Status Register (RSR) (Sheet 2 of 2) 6.2.3 Special Receive Considerations Certain receive conditions relating to the overrun error flag and the break detect flag require further explanation. Consider the following examples: 1) A break is received while the receive buffer is full. This does not produce an overrun condition. Only the B flag will be set after the receiver buffer is read. 2) A new word is received and the receive buffer is full. A break is received before the receive buffer is read. Both the Band OE flags will be set when the buffer full condition is satisfied. 6-5 6.3 TRANSMITTER The transmit buffer is loaded by writing to the USART data register (UDRl. The data word will be transferred to an internal 8-bit shift register when the last word in the shift register has been transmitted. This will produce a buffer empty condition. If the transmitter completes the transmis- sion of the word in the shift register before a new word is written to the transmit buffer, an underrun error will occur. In the asynchronous character format, the transmitter will send a mark until the transmit buffer is written. In the synchronous character format, the transmitter will continuously send the synchronous character. The transmit buffer can be loaded prior to enabling tne transmitter. After the transmitter is enabled, there is a delay before the first bit is output. The serial output line (SO) should be programmed to be high, low, or high impedance when the transmitter is enabled to force the output line to the desired state until the first bit is shifted out. Note that a one bit will always be transmitted prior to the word in the transmit shift register when the transmitter is first enabled. When the transmitter is disabled, any word currently being transmitted will continue to completion. However, any word in the transmit buffer will not be transmitted and will remain in the buffer. So, no buffer empty condition will occur. If the buffer is empty when the transmitter is disabled, the buffer empty condition will remain, but no underrun condition will be generated when the word in transmission is completed. If no word is being transmitted when the transmitter is disabled, the transmitter will stop at the next rising edge of the internal shift clock. In the asynchronous character format, the transmitter can be programmed to send a break. The break will be transmitted once the word currently in the shift register has been sent. If the shift register is empty, the break command will be effective immediately. An END interrupt will be generated at every normal character boundary to aid in timing the break transmission. The break will continue until the break command is cleared. Any character in the transmit buffer at the start of a break will be transmitted when the break is ter- minated. If the transmit buffer is empty at the start of a break, it may be written at any time during the break. If the buffer is still empty at the end of the break, an underrun condition will exist. Disabling the transmitter during a break condition causes the transmitter to cease transmission of the break character at the end of the current character. No end of break stop bit will be transmitted. Even if the transmit buffer is empty, no buffer empty condition will occur nor will an underrun con- dition occur. Also, any word in the transmit buffer will remain. 6.3.1 Transmitter Interrupt Channels The USART transmit section is assigned two interrupt channels. One channel indicates a buffer empty condition and the other channel indicates an underrun or end condition. These interrupting conditions correspond to the BE, UE, and END flag bits of the transmitter status register (TSR). The flag bits will function as described in 6.3.2 Transmitter Status Register whether their associated in- terrupt channel is enabled or disabled. 6.3.2 Transmitter Status Register The transmitter status register contains various transmitter error flags and transmitter control bits for selecting auto-turnaround and loopback mode. The TSR is shown in Figure 6-4. 6-6 7 6 5 4 3 2 1 0 (Hex) 2D I~. BE Address UE_ _~_ _ _ ______L -_ _ AT_ _ _~_ _ END B H L TE _ _~_ _ _ _ _ _~_ _ _ _~_ _ _ _ _ _~_ _ _ _~ BE Buffer Empty. This bit is set when the word in the transmit buffer is transferred to the transmit shift register. This bit is cleared when the transmit buffer is reloaded by writing to the USART data register (UDR). SET a) Transmit buffer contents transferred to transmit shift register CLEARED a) Transmit buffer written UE Underrun Error. This bit is set when the word in the transmit shift register has been transmitted before a new word is loaded into the transmit buffer. This bit is cleared by reading the TSR or by disabling the transmitter. This bit does not need to be cleared before writing to the UDR. SET a) Transmit shift register contents transmitted before transmit buffer written CLEARED a) Transmitter status register read b) Transmitter disabled AT Auto- Turnaround. When this bit is set, the receiver will be enabled automatically after the transmitter has been disabled and the last character being transmitted is completed. This bit is cleared at the end of the transmission. SET a) MPU writes a one CLEARED a) Transmitter disabled END End of Transmission. When the transmitter is disabled while a character is being transmitted, the END will be set after the character transmission is complete. If no word is being transmitted when the transmitter is disabled, the END bit will be set immediately. The END bit is cleared by reenabling the transmitter. SET a) Transmitter disabled CLEARED a) Transmitter enabled B Break. This bit has no function in the synchronous character format. In the asynchronous character format, when this bit is set to a one, a break will be transmitted upon the completion of the transmission of any word in the transmit shift register. A break consists of an all zero data word with no stop bit. When this bit is cleared by soft- ware, the break indication will cease and normal transmission will resume. Note that when B is set, BE cannot be set. SET a) MPU writes a one CLEARED a) MPU writes a zero H, L High and Low. These control bits configure the transmitter output (SO) when the transmitter is disabled. These bits also force the transmitter output after the transmitter is enabled until END is cleared. H L Output State 0 0 High Impedance 0 1 Low 1 0 High 1 1 Loopback Mode Loopback mode internally connects the transmitter output to the receiver input and the transmitter clock to the receiver clock internally. The receiver clock (RC) and the serial input (SI) are not used. When the transmitter is disabled, SO is forced high. SET a) M PU writes a one CLEARED a) MPU writes a zero TE Transmitter Enable. When this bit is cleared, the transmitter is disabled. The UE bit will be cleared and the EN!!) bit will be set. When this bit is set, the transmitter is enabled. The transmitter output will be driven according to the H and L bits until transmission begins. A one bit will be transmitted before the transmission of the word in the transmit shift register is begun. SET a) MPU writes a one CLEARED a) MPU writes a zero b) Reset Figure 6-4. Transmitter Status Register (TSR) 6-7 6.4 DMA OPERATION USART error conditions are only valid for each character boundary. When the USART performs block data transfers by using the DMA handshake lines RR (receiver ready) and TR (transmitter ready), errors must be saved and checked at the end of a block. This is accomplished by enabling the error channel for the receiver or transmitter and by masking interrupts for this channel. Once. the transfer is complete, interrupt pending register A is read. Any pending receiver or transmitter error indicates an error in the data transfer. 6-8 SECTION 7 ELECTRICAL CHARACTERISTICS This section contains the electrical specifications and associated timing information for the MC68901 multi-function peripheral. 7.1 MAXIMUM RATINGS Rating Symbol Value Unit This device contains circuitry to protect Supply Voltage VCC -0.3 to 7.0 V the inputs against damage due to high -0.3 to 7.0 V static voltages or electric fields; however, Input Voltage Vin it is advised that normal precautions be Operating Temperature Range TA o to 70 °c taken to avoid application of any voltage Storage Temperature Tstg -65 to 150 °c higher than maximum-rated voltages to Power Dissipation PD 1.5 W this high-impedance circuit. Reliability of operation is enhanced if unused inputs are tied to an appropriate logic voltage level (e.g., either VCC or GND). 7.2 THERMAL CHARACTERISTICS Characteristic Symbol Value Rating Thermal Resistance Ceramic (JJA 40 °C/W Plastic TBD 7.3 POWER CONSIDERATIONS The average chip-junction temperature, T J, in °c can be obtained from: T J =TA+ (Poe (JJA) (1 ) Where: T A = Ambient Temperature, °c (JJA = Package Thermal Resistance, Junction-to-Ambient, °C/W PO= PINT+ PliO PINT= ICC x VCe, Watts - Chip Internal Power PI/O= Power Oissipation on Input and Output Pins - User Oetermined For most applications PI/O< PINT and can be neglected. An approximate relationship between Po and T J (if PliO is neglected) is: PO= K+ (T J + 273°C) (2) Solving equations 1 and 2 for K gives: K= poe(T A + 273°C) + (JJA P02 (3) Where: K is a constant pertaining to the particular part. K can be determined from equation (3) by measuring Po (at equilibrium) for a known T A Using this value of K the values of Po and T J can be obtained by solving equations (1) and (2) iteratively for any value of T A 7-1 7.4 DC ELECTRICAL CHARACTERISTICS (TA=O°C to 70°C, VCC= -5 V ±5%, unless otherwise noted) Characteristic Symbol Min Max Unit Input High Voltage VIH 2.0 VCC+0.3 V Input Low Voltage VIL -0.3 0.8 V Output High Voltage, Except DTACK (lOH= -120 /LA) VOH 2.4 - V Output Low Voltage, Except DTACK (lOL =2.0 mAl VOL - 0.5 V Power Supply Current (Outputs Open) ILL - 180 mA Input Leakage Current (Vin = 0 to V CC) III - 10 /LA Hi-Z Output Leakage Current in Float (Vout = 2.4 to V CC) ILOH - 10 /LA Hi-Z Output Leakage Current in Float (V ou t=0.5 V) ILOL - -10 /LA DTACK Output Source Current (Vout= 2.4 V) IOH - -400 /LA DTACK Output Sink Current (V out =0.5 V) 10L - 5.3 mA 7.5 CAPACITANCE (T A = 25°C, f= 1 MHz, unmeasured pins returned to ground) Characteristic Input Capacitance Hi-Z Output Capacitance +5V IRQ 0-----. I CL =1OO PF Figure 7-1. IRQ Test Load +5V for ali outputs except DT ACK CL = 100 pF RL =20 k{} Test RL=1.90k{} Point for DTACK CL =130 pF RL =6 k{} MMD7000 Or RL =740 {} Equivalent Figure 7-2. Typical Test Load 7-2 7.6 CLOCK TIMING Characteristic Symbol Min Max Unit Frequency of Operation f 1.0 4.0 MHz Cycle Time tCYC 250 1000 ns Clock Pulse Width tCl, tCH 110 250 ns Rise and Fall Times tCr, tCf - 15 ns r 30 pF 1----..---.. XTAL1 Crystal Parameters Parallel resonance fundamental mode AT cut RS s 1500 (f= 2.8-4.0 MHz) MC68901 RS s300 0 (f= 2.0- 2.7 MHz) Cl = 18 pF, CM =0.02 pF, CR =5 pF, lM =96 MHz f (typical) = 2.4576 MHz 1----..---.. XT Al2 Figure 7-3. MFP External Oscillator Components 7-3 7.7 AC ELECTRICAL CHARACTERISTICS (Vee=5.0 Vdc ±5%, VSS =0 Vdc, TA=oDe to 70 De unless otherwise noted; See Figures 7-4 through 7-7) Num Characteristic Min Max Unit 1 CS, lACK, DS Width High 50 - ns 2 Address Valid to Falling CS Setup Time 30 - ns 3 Data Valid Prior to Rising DS Setup Time 280 - ns 4(1) CS, lACK Valid to Falling Clock Setup Time 50 - ns 5 Clock Low to DT ACK Low - 220 ns 6 CS or DS High to DTACK High - 60 ns 7 CS or DS' High to DTACK High Impedance - 100 ns 8 CS or DS High to Data Invalid Hold Time 0 - ns 9 CS or DS High to Data High Impedance - 50 ns 10 CS or DS High to Address Invalid Hold Time 0 - ns 11 Data Valid from CS Low - 250 ns 12 Read Data Valid to DTACK Low Setup Time 50 - ns 13 DT ACK Low to DS or CS High Hold Time 0 - ns 14 lEI Low to Clock Falling Setup Time 50 - ns 15 lEO Valid from Clock Low Delay Time - 220 ns 16 Data Valid from Clock Low Delay Time - 300 ns 17 lEO Invalid from lACK High Delay Time - 100 ns 18 DT ACK Low from Clock High Delay Time - 220 ns 19 lEO Valid from lEI Low Delay Time - 140 ns 20 Data Valid from lEI Low Delay Time - 200 ns 21 Clock Cycle Time 250 1000 ns 22 Clock Width Low 110 - ns 23 Clock Width High 110 - ns 24(2) CS, lACK Inactive to Rising Clock Setup Time 100 - ns 25 I/O Minimum Active Pulse Width 100 - ns 26 I/O Minimum Time Between Active Edges 100 - ns 27 I/O Data Valid from Rising CS or DS - 500 ns 28 Receiver Ready Delay from Rising RC - 240 ns 29 Transmitter Ready Delay from Rising TC - 295 ns 30 Timer Output Low from Rising Edge of CS or DS (A and B) (Reset Output Time) - 500 ns 31 Output Time Valid from Internal Timeout - 2 tCLK ns +300 32 Timer Clock Low Time 110 - ns 33 Timer Clock High Time 110 - ns 34 Timer Clock Cycle Time 250 1000 ns 35 RESET Low Time 2 - p's 36 Delay to Falling INTR from External Interrupt Active Transition - 380 ns 37 Transmitter Internal Delay from Rising or Falling Edge of TC 550 - ns 38 Receiver Buffer Full Interrupt Transition Delay Time from Rising Edge of RC 750 - ns 39 Receiver Error Interrupt Transition Delay Time from Falling Edge of RC 750 - ns 40 Serial Input Setup Time from Rising Edge of RC (Divide-by-One Only) 80 - ns 41 Data Hold Time from Rising Edge of RC (Divide-by-One Only) 350 - ns 42 Serial Output Data Valid from Falling Edge of TC - 390 ns 43 Transmitter Clock Low Time 500 - ns NOTES: 1. If the setup time is not met, CS will not be recognized until the next falling clock. 2, If this setup time is met (for consecutive cycles), the minimum hold-off time of one clock cycle will be obtained, If not met, the hold-off time will be two clock cycles. 7-4 7.7 AC ELECTRICAL CHARACTERISTICS (Continued) (VCC=5.0 Vdc ±5%, VSS=O Vdc, TA=O°C to 70°C, unless otherwise noted; See Figures 7-4 through 7-7) Num Characteristic Min Max Unit 44 Transmitter Clock High Time 500 - ns 45 Transmitter Clock Cycle Time 1.05 - ns 46 Receiver Clock Low Time 500 - ns 47 Receiver Clock High Time 500 - ns 48 Receiver Clock Cycle Time 1.05 - ns 49 CS, lACK, DS Width Low - 80 tCLK 50 Serial Output Data Valid from Falling Edge of TC (Divided-by 16) - 490 ns Timing diagrams (Figures 7-4, 7-5, 7-6, and 7-7) are located on foldout pages 1 through 4 at the end of this document. 7.8 TIMER AC CHARACTERISTICS Definitions: Error= Indicated time value - actual time value tpsc= tCLK x Prescale Value Internal Timer Mode: Single Interval Error (Free Running) (See Note 2) .................................. ± 100 ns Cumulative Internal Error ............................................................. 0 Error Between Two Timer Reads ....................................... ± (tpsc - 4 tCLK) Start Timer to Stop Timer Error .................. 2 tCLK + 100 ns to - (tpsc+ 6 tCLK + 100 ns) Start Timer to Read Timer Error .............................. 0 to - (tpsc+ 6 tCLK + 400 ns) Start Timer to Interrupt Request Error (See Note 3) ............ - 2 tCLK to - (4 tCLK + 800 ns) Pulse Width Measurement Mode: Measurement Accuracy (See Note 1) ............................ 2 tCLK to - (tpsc+4 tCLK) Minimum Pulse Width .......................................................... 4 tCLK Event Counter Mode: Minimum Active Time of TAl and TBI ............................................ .4 tCLK Minimum Inactive Time of TAl and TBI ............................................ 4 tCLK NOTES: 1. Error may be cumulative if repetitively performed. 2. Error with respect to tout or IRQ if note 3 is true. 3. Assuming it is possible for the timer to make an interrupt request immediately. 7-5/7-6 SECTION 8 MECHANICAL DATA AND ORDERING INFORMATION This section contains the pin assignments, package dimensions, and ordering information for the MC68901. 8.1 PIN ASSIGNMENTS R/W cs RS1 2 DS DTACK lACK D7 D6 D5 D4 D3 RC D2 vcc D1 NC DO TAO GND T80 ClK TCO ill TDO lEO XTAl1 IRQ XTAL2 FiR TAl, TIl T81 10 11 8-1 8.2 PACKAGE DIMENSIONS U ]J L SUFFIX CERAMIC PACKAGE CASE 740-02 )::=:==:::::j[ f-ch-=====~=~I I1-------------89 ------------~ ~F I -L~-H+I-I+HI-I-I-I+I~.j ~ Jo ~GL -l\-J 1- -.j ~M --1 IT] L NOTES: MILLIMETERS INCHES 1. DIMENSION [Aj IS DATUM. DIM MIN MAX MIN MAX 2. POSTIONAL TOLERANCE FOR LEADS: A 60.35 61.57 2.376 2.424 B 14.63 15.34 0.576 0.604 Itl0' I 0.25 (0.010)@!T A@I C 3.05 4.32 0.120 0.160 3. IT] IS SEATING PLANE. .0 0.381 0.533 0.015 0.021 4. DIMENSION "L" TO CENTER OF LEAOS F 0.762 1.397 0.030 0.055 WHEN FORMED PARALLEL. G 2.54 BSC 0.100 BSC 5. DIMENSIONING AND TOLERANCING PER J 0.203 0.330 0.008 0.013 ANSI Y14.5, 1973. K 2.54 4.19 0.100 0.165 L 14.99 15.65 0.590 0.616 M 00 100 00 100 N 1.016 1.524 0.040 0.060 P SUFFIX PLASTIC PACKAGE CASE 767-01 MILLIMETERS INCHES NOTES: 1. Of] IS ENO OF PACKAGE DIM MIN MAX MIN MAX DATUM PLANE. A 61.67 61.77 2.428 2.432 [[lIS BOTH A DATUM AND B 13.92 14.02 0.548 0.552 SEATING PLANE. C 4.83 5.06 0.190 0.200 2. POSITIONAL TOLERANCE 0 0.38 0.50 0.015 0.020 FOR LEADS 24 &. 25: F 1.22 1.34 0.048 0.053 G 2.54 BSC 0.100 BSC 1.10.35 (0.014) ITI B @IR I J 0.25 I 0.30 0.010 0.012 POSITIONAL TOLERANCE K 3.23 I 3.37 0.127 0.133 FOR LEAD PATIERN: L 15.24 BSC 0.600 BSC ,.10.25 (0.010) ITI B@I M 00 I 100 00 100 3. DIM B DOES NOT INCLUDE N 0.64 0.88 0.025 0.035 MOLD FLASH . U 1.79 BSC . 0.070 BSC 4. DIM L IS TO CENTER OF LEADS WHEN FORMED PARALLEL. 5. DIMENSIONING AND TOLERANCING PER ANSI Y14.5, 1973. 8-2 8.3. ORDERING INFORMATION Maximum Clock Temperature Package Type Frequency Range Order Number Ceramic 4.0 MHz O°C to 70°C MC68901L L Suffix Plastic 4.0 MHz O°C to 70°C MC68901P P Suffix 8-3/8-4 elK RiVii cs OS RS1-RS5 11 00-07 Figure 7-4. Read Cycle Timing Foldout 1 elK R/W RS1-RS5 DO-D7 Figure 7-5. Write Cycle Timing Foldout 2 1. 'iEO only goes low if no acknowledgeable interrupt is pending. If lEO goes low, DT ACK and the data bus remain in the high- impedance state. Figure 7-6. Interrupt Acknowledge Cycle (iEi Low) Foldout 3 ClK 00-07 NOTES: 1. iEO only goes low if no acknowledgeable interrupt is pending. If I EO goes low, DT ACK and the data bus remain in the high- impedance state. 2. DT ACK will go low at 0 if specification number 14 is met. Otherwise, DT ACK will go low at @. Figure 7-7. Interrupt Acknowledge Cycle (TEi High) Foldout 4 ® MOTOROI.A Semiconductor Products Inc. 3501 ED BLUESTEIN BLVD., AUSTIN, TEXAS 78721 • A SUBSIDIARY OF MOTOROLA INC. A16081 PRINTED IN USA 1-84 IMPERIAL LITHO C19014 18,000