SAAS050 SERIES APPLICATION DATA (continued) 14, 15. 16. 18. 19. 20. 21. 22,23, 24. 25. 26. 27. 28. CRS Character rounding select This input signal from the SAA5020 Timing Chain is required for correct character rounding of displayed characters. (Normal height characters only). BCS Big character select This input from the SAA5040 Teletext Acquisition and Control device allows selection of large characters by remote control. TLC Transmitted large characters This output to the SAA5020 Timing Chain enables double height characters to be displayed as a result of control characters stored in the page memory. Vpop + 5 V supply This is the power supply input to the circuit. TRE This input is a 6 MHz signal from the SAA5020 Timing Chain used as a character dot rate clock. FI This input is a 1 MHz equa! mark/space ratio signal from the SAA5020 Timing Chain. It is used to latch the 7-bit parallel character data into the input latches. [It is also used to synchron- ise an internal divide-by 6 counter. The F1 signal is internally synchronised with TR6. Y Output This is a video output signa! which is active in the HIGH state containing character dot information for tv display. The output is an open drain transistor capable of sinking current to Vgg B,G,F outputs These are the Blue, Green and Red Character video outputs to the tv display circuits. They are active HIGH and contain both character and background colour information. The outputs are open drain transistors capable of sinking current to Vs. BLAN Blanking This active HIGH output signal provides tv picture video blanking. It is active for the duration of a box when Picture On and Display Enable are HIGH. It is also activated permanently for normal teletext display when no tv picture is required (PO LOW). The output is an open drain transistor capable of sinking current to Vgg. Full details given in Table 3. LOSE Load output shift register enable This input signal from the SAA5020 Timing Chain resets the internal control character flip-flops prior to the start of each display line. This signal also defines the character display period. PO Picture On This input signal from the SAA5040 Teletext Acquisition and Control device is used to control the character video and blanking outputs. When PO is HIGH, only text in boxes is displayed unless in superimpose mode. The input is H!GH for tv picture video on, LOW for picture off. See Table 3. DE Display enable This input signal from the SAA5040 Teletext Acquisition and Control device is used to enable the teletext display. The input is HIGH for teletext display enabled. LOW for display cancelled. See Table 3. we: (Mullard o