this little program can be used to verify that a cartridge is properly disabled when RUNning a program. the expected/correct output very much depends on the individual cartridge and cartridge-ROM (see below). - in the first two rows you see a dump of the values read from the beginning of the IO1 and IO2 blocks - below that is a copy of what can be read from $8000. if you see a pattern that shows all values 0...$ff then you are looking at the C64 RAM - next is the IO1 page - last not least the IO2 page - after RESET restart the program with SYS 2560 -------------------------------------------------------------------------------- expected results: -------------------------------------------------------------------------------- Retro Replay, MMC-Replay, Nordic Replay (with Retro-Replay ROM): ---------------------------------------------------------------- RUN with cartridge enabled ("install fastload" in main screen): - registers de00 and de01 read as 48, 48 - at 8000 is RAM - de00 page is active cartridge ROM - df00 page is inactive (open I/O) RUN with cartridge disabled ("normal reset" in main screen): - at 8000 is RAM - de00 page is inactive (open I/O) - df00 page is inactive (open I/O) Final Cartridge III: -------------------- RUN with cartridge enabled: - at 8000 is RAM - de00 page is active cartridge ROM - df00 page is active cartridge ROM RUN with cartridge disabled: - at 8000 is RAM - de00 page is active cartridge ROM - df00 page is active cartridge ROM Super Snapshot v5: ------------------ RUN with cartridge enabled: - at 8000 is RAM - de00 page is active cartridge ROM - df00 page is inactive (open I/O) RUN with cartridge disabled (F8 in main screen): - at 8000 is RAM - de00 page is inactive (open I/O) - df00 page is inactive (open I/O)