;------------------------------------------------------------------------------------ ; Test - ;-Description: ;------------------------------------------------------------------------------------ TestDMAFillSourceRegUpdateText: dc.b 'DMA Fill Source Reg Update ' TestDMAFillSourceRegUpdateTextEnd: TestDMAFillSourceRegUpdateExpectedResult: dc.w $5555, $4444, $3333, $2222, $1111, $FFFF, $EEEE, $DDDD, $FFFF, $EEEE, $DDDD, $CCCC TestDMAFillSourceRegUpdate: ;Initialize the text result block move.w #(TestDMAFillSourceRegUpdateTextEnd-TestDMAFillSourceRegUpdateText),D7 move.w #2,(A0)+ ;Set the number of display lines move.w D7,(A0)+ ;Set the text length move.w #$0018,D6 ;Set the data length move.w D6,(A0)+ lea TestDMAFillSourceRegUpdateText,A1 sub.w #1,D7 TestDMAFillSourceRegUpdateWriteText: move.b (A1)+,(A0)+ dbf D7,TestDMAFillSourceRegUpdateWriteText move.w #1,(A0)+ ;Set the expected result data present flag lea TestDMAFillSourceRegUpdateExpectedResult,A1 ;Write the expected result data to the buffer sub.w #1,D6 TestDMAFillSourceRegUpdateWriteExpectedResultData: move.b (A1)+,(A0)+ dbf D6,TestDMAFillSourceRegUpdateWriteExpectedResultData ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA transfer from 0x1F4 in the source data block to VRAM address 0x9000 for 8 bytes move.l #(VRAMTestDataBlockAligned+$1F4),D0 move.w #$0004,D1 move.w #$8154,$C00004 move.w #$8F02,$C00004 move.w #$9300, D2 move.b D1,D2 move.w D2,$C00004 move.w #$9400, D2 lsr.l #8,D1 move.b D1,D2 move.w D2,$C00004 move.w #$9500, D2 lsr.l #1,D0 move.b D0,D2 move.w D2,$C00004 move.w #$9600, D2 lsr.l #8,D0 move.b D0,D2 move.w D2,$C00004 move.w #$9700, D2 lsr.l #8,D0 move.b D0,D2 move.w D2,$C00004 ;We do the transfer to initiate the DMA operation using RAM here, otherwise we almost ;always get a lockup on the real hardware. move.l #$40000082,(A0) ;DMA transfer to VRAM address 0x8000 move.l (A0),$C00004 ;Test target memory move.l #$00000002,$C00004 ;Read from VRAM at 0x8000 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA fill operation to 0x8000 for 4 bytes with the source register set to 0x00FA move.l #$00FA,D0 move.w #$0004,D2 move.w #$8F01,$C00004 move.w #$8154,$C00004 move.w #$9300, D7 move.w D2,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9400, D7 lsr.l #8,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9500, D7 move.w D0,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9600, D7 lsr.l #8,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9780,$C00004 move.l #$40000082,(A0) ;DMA fill at VRAM address 0x8000 nop ;If we uncomment this block, we get corrupted write data at the start of the nop ;fill. If we don't have any wait cycles between the control port write and the nop ;data port write, the written data is usually correct, with the exception that nop ;the byte order of the first write is reversed. If we do insert wait states nop ;between the control port write and the data port write, without any wait states nop ;before the control port write, the fill starts with a fill data of 0x00, and at nop ;some point during the fill operation, usually 4 or 5 bytes in, the data port nop ;write then occurs, and the fill operation from then on picks up the correct fill nop ;data from that data port write. In other words, if we don't insert a wait state nop ;between when we set all our registers for a fill above, and when we actually nop ;perform the control port write to setup for the fill operation, the fill can nop ;inadvertantly trigger immediately when the control port write is made, without nop ;waiting for the data port write to occur. We have found from testing that at nop ;least 20 NOP cycles are required in order to get reliable results, when the nop ;control port write occurs as a long word write from RAM. nop nop nop nop nop move.l (A0),$C00004 move.w #$1234,$C00000 ;Start DMA fill with 0x1234 TestDMAFillSourceRegUpdateDMAWaitLoop1: move.w $C00004,D5 btst #1,D5 bne TestDMAFillSourceRegUpdateDMAWaitLoop1 move.w #$8144,$C00004 move.w #$8F02,$C00004 ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA transfer from 0x1F4 in the source data block to VRAM address 0x8000 for 8 bytes, not updating ;the lower address byte. move.l #(VRAMTestDataBlockAligned+$1F4),D0 move.w #$0004,D1 move.w #$8154,$C00004 move.w #$8F02,$C00004 move.w #$9300, D2 move.b D1,D2 move.w D2,$C00004 move.w #$9400, D2 lsr.l #8,D1 move.b D1,D2 move.w D2,$C00004 move.w #$9500, D2 lsr.l #1,D0 move.b D0,D2 ; move.w D2,$C00004 move.w #$9600, D2 lsr.l #8,D0 move.b D0,D2 move.w D2,$C00004 move.w #$9700, D2 lsr.l #8,D0 move.b D0,D2 move.w D2,$C00004 ;We do the transfer to initiate the DMA operation using RAM here, otherwise we almost ;always get a lockup on the real hardware. move.l #$40000082,(A0) ;DMA transfer to VRAM address 0x8000 move.l (A0),$C00004 ;Test target memory move.l #$00000002,$C00004 ;Read from VRAM at 0x8000 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA fill operation to 0x8000 for 4 bytes with the source register set to 0x00FE move.l #$00FE,D0 move.w #$0004,D2 move.w #$8F01,$C00004 move.w #$8154,$C00004 move.w #$9300, D7 move.w D2,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9400, D7 lsr.l #8,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9500, D7 move.w D0,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9600, D7 lsr.l #8,D6 move.b D6,D7 move.w D7,$C00004 move.w #$9780,$C00004 move.l #$40000082,(A0) ;DMA fill at VRAM address 0x8000 nop ;If we uncomment this block, we get corrupted write data at the start of the nop ;fill. If we don't have any wait cycles between the control port write and the nop ;data port write, the written data is usually correct, with the exception that nop ;the byte order of the first write is reversed. If we do insert wait states nop ;between the control port write and the data port write, without any wait states nop ;before the control port write, the fill starts with a fill data of 0x00, and at nop ;some point during the fill operation, usually 4 or 5 bytes in, the data port nop ;write then occurs, and the fill operation from then on picks up the correct fill nop ;data from that data port write. In other words, if we don't insert a wait state nop ;between when we set all our registers for a fill above, and when we actually nop ;perform the control port write to setup for the fill operation, the fill can nop ;inadvertantly trigger immediately when the control port write is made, without nop ;waiting for the data port write to occur. We have found from testing that at nop ;least 20 NOP cycles are required in order to get reliable results, when the nop ;control port write occurs as a long word write from RAM. nop nop nop nop nop move.l (A0),$C00004 move.w #$1234,$C00000 ;Start DMA fill with 0x1234 TestDMAFillSourceRegUpdateDMAWaitLoop2: move.w $C00004,D5 btst #1,D5 bne TestDMAFillSourceRegUpdateDMAWaitLoop2 move.w #$8144,$C00004 move.w #$8F02,$C00004 ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA transfer from 0x1FC in the source data block to VRAM address 0x8000 for 8 bytes, not updating ;the middle address byte. move.l #(VRAMTestDataBlockAligned+$1FC),D0 move.w #$0004,D1 move.w #$8154,$C00004 move.w #$8F02,$C00004 move.w #$9300, D2 move.b D1,D2 move.w D2,$C00004 move.w #$9400, D2 lsr.l #8,D1 move.b D1,D2 move.w D2,$C00004 move.w #$9500, D2 lsr.l #1,D0 move.b D0,D2 move.w D2,$C00004 move.w #$9600, D2 lsr.l #8,D0 move.b D0,D2 ; move.w D2,$C00004 move.w #$9700, D2 lsr.l #8,D0 move.b D0,D2 move.w D2,$C00004 ;We do the transfer to initiate the DMA operation using RAM here, otherwise we almost ;always get a lockup on the real hardware. move.l #$40000082,(A0) ;DMA transfer to VRAM address 0x8000 move.l (A0),$C00004 ;Test target memory move.l #$00000002,$C00004 ;Read from VRAM at 0x8000 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop ;Clear data in VRAM at 0x8000 move.l #$40000002,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 rts