;------------------------------------------------------------------------------------ ;Test 12 - DMA Fill to CRAM ;------------------------------------------------------------------------------------ TestDMAFillToCRAMText: dc.b 'DMA Fill to CRAM ' TestDMAFillToCRAMTextEnd: TestDMAFillToCRAMExpectedResult: dc.w $0000, $0000, $0000, $0000, $0000, $0000, $0000, $0000, $0224, $0000, $0000, $0000, $0224, $0000, $0000, $0000 TestDMAFillToCRAM: ;Initialize the text result block move.w #(TestDMAFillToCRAMTextEnd-TestDMAFillToCRAMText),D7 move.w #2,(A0)+ ;Set the number of display lines move.w D7,(A0)+ ;Set the text length move.w #$0020,D6 ;Set the data length move.w D6,(A0)+ lea TestDMAFillToCRAMText,A1 sub.w #1,D7 TestDMAFillToCRAMWriteText: move.b (A1)+,(A0)+ dbf D7,TestDMAFillToCRAMWriteText move.w #1,(A0)+ ;Set the expected result data present flag lea TestDMAFillToCRAMExpectedResult,A1 ;Write the expected result data to the buffer sub.w #1,D6 TestDMAFillToCRAMWriteExpectedResultData: move.b (A1)+,(A0)+ dbf D6,TestDMAFillToCRAMWriteExpectedResultData ;Clear data in CRAM at 0x20 move.l #$C0200000,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA fill operation to CRAM address 0x20 move.w #$0004,D1 move.w #$8F01,$C00004 move.w #$8154,$C00004 move.w #$9300, D2 move.b D1,D2 move.w D2,$C00004 move.w #$9400, D2 lsr.l #8,D1 move.b D1,D2 move.w D2,$C00004 move.w #$9780,$C00004 move.l #$C0200080,(A0) ;DMA fill at CRAM address 0x20 nop ;If we uncomment this block, we get corrupted write data at the start of the nop ;fill. If we don't have any wait cycles between the control port write and the nop ;data port write, the written data is usually correct, with the exception that nop ;the byte order of the first write is reversed. If we do insert wait states nop ;between the control port write and the data port write, without any wait states nop ;before the control port write, the fill starts with a fill data of 0x00, and at nop ;some point during the fill operation, usually 4 or 5 bytes in, the data port nop ;write then occurs, and the fill operation from then on picks up the correct fill nop ;data from that data port write. In other words, if we don't insert a wait state nop ;between when we set all our registers for a fill above, and when we actually nop ;perform the control port write to setup for the fill operation, the fill can nop ;inadvertantly trigger immediately when the control port write is made, without nop ;waiting for the data port write to occur. We have found from testing that at nop ;least 20 NOP cycles are required in order to get reliable results, when the nop ;control port write occurs as a long word write from RAM. nop nop nop nop nop move.l (A0),$C00004 move.w #$1234,$C00000 ;Start DMA fill with 0x1234 TestDMAFillToCRAMDMAWaitLoop1: move.w $C00004,D5 btst #1,D5 bne TestDMAFillToCRAMDMAWaitLoop1 move.w #$8144,$C00004 move.w #$8F02,$C00004 move.l #$00200020,$C00004 ;Read from CRAM at 0x20 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop move.l #$00210020,$C00004 ;Read from CRAM at 0x21 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop ;Clear data in CRAM at 0x20 move.l #$C0200000,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 ;Do a DMA fill operation to CRAM address 0x21 move.w #$0004,D1 move.w #$8F01,$C00004 move.w #$8154,$C00004 move.w #$9300, D2 move.b D1,D2 move.w D2,$C00004 move.w #$9400, D2 lsr.l #8,D1 move.b D1,D2 move.w D2,$C00004 move.w #$9780,$C00004 move.l #$C0210080,(A0) ;DMA fill at CRAM address 0x21 nop ;If we uncomment this block, we get corrupted write data at the start of the nop ;fill. If we don't have any wait cycles between the control port write and the nop ;data port write, the written data is usually correct, with the exception that nop ;the byte order of the first write is reversed. If we do insert wait states nop ;between the control port write and the data port write, without any wait states nop ;before the control port write, the fill starts with a fill data of 0x00, and at nop ;some point during the fill operation, usually 4 or 5 bytes in, the data port nop ;write then occurs, and the fill operation from then on picks up the correct fill nop ;data from that data port write. In other words, if we don't insert a wait state nop ;between when we set all our registers for a fill above, and when we actually nop ;perform the control port write to setup for the fill operation, the fill can nop ;inadvertantly trigger immediately when the control port write is made, without nop ;waiting for the data port write to occur. We have found from testing that at nop ;least 20 NOP cycles are required in order to get reliable results, when the nop ;control port write occurs as a long word write from RAM. nop nop nop nop nop move.l (A0),$C00004 move.w #$1234,$C00000 ;Start DMA fill with 0x1234 TestDMAFillToCRAMDMAWaitLoop2: move.w $C00004,D5 btst #1,D5 bne TestDMAFillToCRAMDMAWaitLoop2 move.w #$8144,$C00004 move.w #$8F02,$C00004 move.l #$00200020,$C00004 ;Read from CRAM at 0x20 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop move.l #$00210020,$C00004 ;Read from CRAM at 0x21 move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ move.w $C00000,(A0)+ nop ;Wait for a few cycles after a read before modifying any VDP settings. On the nop ;real hardware, if a control port write occurs immediately after a data port nop ;read, the VDP can lock up. Most likely, this occurs due to the read target nop ;being modified to an invalid target before a read pre-cache is complete. nop nop nop nop nop nop ;Clear data in CRAM at 0x20 move.l #$C0200000,$C00004 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 move.w #$0000,$C00000 rts