-- -- File Name: AlertLog_Demo_Hierarchy.vhd -- Design Unit Name: AlertLog_Demo_Hierarchy -- Revision: STANDARD VERSION, 2015.01 -- -- Copyright (c) 2015 by SynthWorks Design Inc. All rights reserved. -- -- -- Maintainer: Jim Lewis email: jim@synthworks.com -- Contributor(s): -- Jim Lewis email: jim@synthworks.com -- -- Description: -- Demo showing use of hierarchy in AlertLogPkg -- Both TB and CPU use sublevels of hierarchy -- UART does not use sublevels of hierarchy -- Usage of block statements emulates a separate entity/architecture -- -- Developed for: -- SynthWorks Design Inc. -- Training Courses -- 11898 SW 128th Ave. -- Tigard, Or 97223 -- http://www.SynthWorks.com -- -- -- Revision History: -- Date Version Description -- 01/2015 2015.01 Refining tests -- 01/2020 2020.01 Updated Licenses to Apache -- -- -- This file is part of OSVVM. -- -- Copyright (c) 2015 - 2020 by SynthWorks Design Inc. -- -- Licensed under the Apache License, Version 2.0 (the "License"); -- you may not use this file except in compliance with the License. -- You may obtain a copy of the License at -- -- https://www.apache.org/licenses/LICENSE-2.0 -- -- Unless required by applicable law or agreed to in writing, software -- distributed under the License is distributed on an "AS IS" BASIS, -- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. -- See the License for the specific language governing permissions and -- limitations under the License. -- library IEEE ; use ieee.std_logic_1164.all ; use ieee.numeric_std.all ; use std.textio.all ; use ieee.std_logic_textio.all ; library osvvm ; use osvvm.OsvvmGlobalPkg.all ; use osvvm.TranscriptPkg.all ; use osvvm.AlertLogPkg.all ; entity AlertLog_Demo_Hierarchy is end AlertLog_Demo_Hierarchy ; architecture hierarchy of AlertLog_Demo_Hierarchy is signal Clk : std_logic := '0'; begin Clk <= not Clk after 10 ns ; -- ///////////////////////////////////////////////////////////// -- \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Testbench_1 : block constant TB_AlertLogID : AlertLogIDType := GetAlertLogID("Testbench_1") ; begin TbP0 : process variable ClkNum : integer := 0 ; begin wait until Clk = '1' ; ClkNum := ClkNum + 1 ; print(LF & "Clock Number " & to_string(ClkNum)) ; end process TbP0 ; ------------------------------------------------------------ TbP1 : process constant TB_P1_ID : AlertLogIDType := GetAlertLogID("TB P1", TB_AlertLogID) ; variable TempID : AlertLogIDType ; begin -- Uncomment this line to use a log file rather than OUTPUT -- TranscriptOpen("./Demo_Hierarchy.txt") ; -- Uncomment this line and the simulation will stop after 15 errors -- SetAlertStopCount(ERROR, 15) ; SetAlertLogName("AlertLog_Demo_Hierarchy") ; wait for 0 ns ; -- make sure all processes have elaborated SetLogEnable(DEBUG, TRUE) ; -- Enable DEBUG Messages for all levels of the hierarchy TempID := GetAlertLogID("CPU_1") ; -- Get The CPU AlertLogID SetLogEnable(TempID, DEBUG, FALSE) ; -- turn off DEBUG messages in CPU SetLogEnable(TempID, INFO, TRUE) ; -- turn on INFO messages in CPU -- Uncomment this line to justify alert and log reports -- SetAlertLogJustify ; for i in 1 to 5 loop wait until Clk = '1' ; if i = 4 then SetLogEnable(DEBUG, FALSE) ; end if ; -- DEBUG Mode OFF wait for 1 ns ; Alert(TB_P1_ID, "Tb.P1.E alert " & to_string(i) & " of 5") ; -- ERROR by default Log (TB_P1_ID, "Tb.P1.D log " & to_string(i) & " of 5", DEBUG) ; end loop ; wait until Clk = '1' ; wait until Clk = '1' ; wait for 1 ns ; -- Report Alerts without expected errors ReportAlerts ; print("") ; -- Report Alerts with expected errors expressed as a negative ExternalErrors value ReportAlerts(Name => "AlertLog_Demo_Hierarchy with expected errors", ExternalErrors => -(FAILURE => 0, ERROR => 20, WARNING => 15)) ; TranscriptClose ; print(LF & "The following is brought to you by std.env.stop:") ; std.env.stop ; wait ; end process TbP1 ; ------------------------------------------------------------ TbP2 : process constant TB_P2_ID : AlertLogIDType := GetAlertLogID("TB P2", TB_AlertLogID) ; begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 2 ns ; Alert(TB_P2_ID, "Tb.P2.E alert " & to_string(i) & " of 5", ERROR) ; -- example of a log that is not enabled, so it does not print Log (TB_P2_ID, "Tb.P2.I log " & to_string(i) & " of 5", INFO) ; end loop ; wait until Clk = '1' ; wait for 2 ns ; -- Uncomment this line to and the simulation will stop here -- Alert(TB_P2_ID, "Tb.P2.F Message 1 of 1", FAILURE) ; wait ; end process TbP2 ; ------------------------------------------------------------ TbP3 : process constant TB_P3_ID : AlertLogIDType := GetAlertLogID("TB P3", TB_AlertLogID) ; begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 3 ns ; Alert(TB_P3_ID, "Tb.P3.W alert " & to_string(i) & " of 5", WARNING) ; end loop ; wait ; end process TbP3 ; end block Testbench_1 ; -- ///////////////////////////////////////////////////////////// -- \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Cpu_1 : block constant CPU_AlertLogID : AlertLogIDType := GetAlertLogID("CPU_1") ; begin ------------------------------------------------------------ CpuP1 : process constant CPU_P1_ID : AlertLogIDType := GetAlertLogID("CPU P1", CPU_AlertLogID) ; begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 5 ns ; Alert(CPU_P1_ID, "Cpu.P1.E Message " & to_string(i) & " of 5", ERROR) ; Log (CPU_P1_ID, "Cpu.P1.D log " & to_string(i) & " of 5", DEBUG) ; Log (CPU_P1_ID, "Cpu.P1.F log " & to_string(i) & " of 5", FINAL) ; -- disabled end loop ; wait ; end process CpuP1 ; ------------------------------------------------------------ CpuP2 : process constant CPU_P2_ID : AlertLogIDType := GetAlertLogID("CPU P2", CPU_AlertLogID) ; begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 6 ns ; Alert(CPU_P2_ID, "Cpu.P2.W Message " & to_string(i) & " of 5", WARNING) ; Log (CPU_P2_ID, "Cpu.P2.I log " & to_string(i) & " of 5", INFO) ; end loop ; wait ; end process CpuP2 ; end block Cpu_1 ; -- ///////////////////////////////////////////////////////////// -- \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Uart_1 : block constant UART_AlertLogID : AlertLogIDType := GetAlertLogID("UART_1") ; begin -- Enable FINAL logs for every level -- Note it is expected that most control of alerts will occur only in the testbench block -- Note that this does not turn on FINAL messages for CPU - see global for settings that impact CPU SetLogEnable(UART_AlertLogID, FINAL, TRUE) ; -- Runs once at initialization time ------------------------------------------------------------ UartP1 : process begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 10 ns ; Alert(UART_AlertLogID, "Uart.P1.E alert " & to_string(i) & " of 5") ; -- ERROR by default Log (UART_AlertLogID, "UART.P1.D log " & to_string(i) & " of 5", DEBUG) ; end loop ; wait ; end process UartP1 ; ------------------------------------------------------------ UartP2 : process begin for i in 1 to 5 loop wait until Clk = '1' ; wait for 11 ns ; Alert(UART_AlertLogID, "Uart.P2.W alert " & to_string(i) & " of 5", WARNING) ; -- Info not enabled Log (UART_AlertLogID, "UART.P2.I log " & to_string(i) & " of 5", INFO) ; Log (UART_AlertLogID, "UART.P2.F log " & to_string(i) & " of 5", FINAL) ; end loop ; wait ; end process UartP2 ; end block Uart_1 ; end hierarchy ;