CODED PARA METER DATA 8.1 PARAMETER LOOK-UP ROM CODED PARAMETER INPUT REGISTER DECODE LOGIC & CONDITION LATCHES PARAMETER INTERPOLATER INTERPOLATION CONTROLLER FILTER EXCITATION SIGNAL LPC NETWORK UNVOICED) FIGURE 4 — SYNTHESIZER BLOCK DIAGRAM Coded speech parameter data is fed serially from either the VSM or the FIFO buffer to the Parameter Input Register. Here the Controller unpacks the data and performs various tests (i.e., is the repeat bit set, is pitch zero, is energy zero). Once unpacked the coded parameter data is stored in RAM to be used as the index value to select the appropriate value from the Parameter Look-Up ROM. The outputs of the Parameter Look-Up ROM are the target values for the interpolation logic to reach in this frame period. During each of the eight interpolation periods the interpolation logic sends new pitch and energy parameters to the signal generator which produces the filter excitation sequence, and new K-parameter values to the LPC lattice network. So, at the end of each sample period there is a new value of digitized synthetic speech available to the D/A converter. CODED SPEECH PARAMETERS The 12 synthesis parameters (pitch, energy and reflection coefficients K1-K10), are stored in the VSM in coded form. Each parameter occupies between 3-6 bits. These coded values select a 10-bit actual parameter from the parameter Look-Up ROM. Depending on the influence of each parameter on speech quality, between 8 and 64 possible values are stored in the Look-Up ROM for decoding and use in synthesis calculations. Table 3 summarizes parameter coding for the TMS 5220. TABLE 3 — PARAMETER CODING PARAMETER LEVELS CODE BITS ENERGY 15* 4 PITCH 64 6 Ki 32 5 K2 32 5 K3 16 4 K4 16 4 K5 16 4 K6 16 4 K7 16 4 KB 8 3 Kg 8 3 K10 8 3 12 247 49+REPEAT=50BITS 8 * Energy = 1111 is the stop code,