A. APPENDIX A SYSTEM CLOCK TMS 5200 10 pF RC OPTION TYPICAL VALUES: SAMPLE FREQUENCY R 10 kHz R = 80-100 ka 8 kHz R = 120-200 kn FIGURE A-1 — TMS 5200 OSCILLATOR OPTIONS OSCILLATOR TRIMMING PROCEDURE To avoid capacitive loading of the high impedance OSC input, the following procedure is recommended for setting the TMS 5220 clock frequency. Reference to Table A-1, Comparison of System Times (page 16), shows that an RC oscilla- tor frequency of 640 kHz corresponds to a ROM clock rate of 160 kHz. This signal is buffered and not affected by measurement instrument capacities. To set the RC oscillator frequency, connect a frequency counter to the ROM clock output of the TMS 5220 and trim the reading to 160 kHz. Use of 10 pF shunt capacitor is recommended to prevent circuit layout and environmental stray noise from affecting device operation. 14