B.1.2.1 READ Before WRITE Considerations There are different READ and WRITE addresses for most of the memory-mapped devices (MMDs). This is because the TMS 9900 does a READ operation at the destination address prior to writing to it. Many of the MMDs have internal address registers that autoinecrement after either a RFAN or a WRITF Operation. This autoincrement characteristic of the MMD may not produce the desired results if it is not taken into consideration when designs or modifications are made. The READ before WRITE exists because the 9900 is a word-oriented machine from a memory access standpoint. The several byte-oriented instructions are carried out by the machine in a word execution format, and the other byte in the word must not be altered. The machine itself must save the unaltered byte, concatenate the new byte with it, and return the word to memory. The internal logic of the TMS 9900 is designed this way because it was to the designers distinct advantage to do this same READ before WRITE on both byte and word moves. B,1.2.2 Cartridge Memory Space The cartridge memory space at >6000 must be treated as if it is logically connected to the cartridge port. The GROM chips are rather poor line drivers at best, and their life on the 1/0 data bus is limited. Even though the GROM data bus is currently connected directly to the [/0 data bus, there is no guarantee that updated versions of the TI-99/4A will have the sdme connection. The new generation TI console will probably isolate the GROM data bus from the 1/0 data bus. DON'T TRY TO ACCESS THE CARTRIDGE MEMORY SPACE FROM THE I/O PORT! 22