B.2--EXPANSION UNIT REQUIREMENTS B.2.1 System Bus Requirements There are only two design considerations that must be understood to interface with the system bus. Qne controls a Data Bus driver on the TI-99/4A end of the connecting cable, and the other is used during printed circuit board (PUB) burn-in. B.2.1.1 Remote Data Bus Driver. As has been previously noted, there are additional requirements for interfacing through the Peripheral Expansion Unit (PFII). Regardless of the processor driving the PEU, a signal must be provided to indicate to the interface that a memory cycle is being requested for a PCB in the PEU. This signal is termed "RDBENA*", and is used to enable Data Bus drivers on the TI-99/4A end of the cable. It must function as an open-collector signal, but a tri-state gate may be used instead if the input is grounded and the tri-state controller is connected in parallel with that gate for the Data Bus Buffer. B.2.1.2 Burn-In Consideration. A single high true line shall be provided to enable the PCB to respond to both memory and CRU accesses. This line is held at a high level in the PEU, but is driven to allow a parallel connection of 16 PCBs during burn-in. When low, this signal shall disable the PCB from driving any of the system memory and CRU bus lines. The interrupt sensing has been excepted from this in the past. 8.2.2 Power Allocation Assumptions The following is a guide for maximum load current a PCB should present to the PEU. ) 250 ma on the +15v unregulated bus. o 500 ma on the *+8v unregulated bus. ) 30 ma on the -15v unregulated bus. 28