TRANSIENT VOLTAGE SUPPRESSION DEVICES 1995 SEMICONDUCTOR $5.00 SEMICONDUCTOR HARRIS SEMICONDUCTOR TRANSIENT VOLTAGE SUPPRESSION This Transient Voltage Suppression Databook represents the full line of Harris Semiconductor transient voltage suppression products for commercial and military applications and supersedes previously published transient voltage material under the Harris, GE, RCA or Intersil names. For a complete listing of all Harris Semiconductor products, please refer to the Product Selection Guide (PSG-201 ; ordering information below). For complete, current and detailed technical specifications on any Harris devices please contact the nearest Harris sales, representative or distributor office. Literature requests may also be directed to: Harris Semiconductor Data Services Department P.O. Box 883, MS 53-204 Melbourne, FL 32902 Phone: 1-800-442-7747 Fax: 407-724-7240 See Section 14 for information available on AnswerFAX, 407-724-7800 SEE US ON THE NET . . . Harris' home page is http://vrow.semi.harris.com or E:mail our Central Applications Group at centapp@harris.com, for technical assistance U.S. HEADQUARTERS Harris Semiconductor P. O. Box 883, Mail Stop 53-210 Melbourne, FL 32902 TEL: 1-800-442-7747 (407) 729-4984 FAX: (407) 729-5321 ASIA Harris Semiconductor PTE Ltd. No. 1 Tannery Road Cencon 1 , #09-01 Singapore 1334 TEL: (65) 748-4200 FAX: (65) 748-0400 EUROPEAN HEADQUARTERS Harris Semiconductor Mercure Center 100, Rue de la Fusee 1130 Brussels, Belgium TEL: 32 2 724 21 11 FAX: 32 2 724 22 05 All Harris Semiconductor products are manufactured, assembled and tested under ISO9000 quality system certifications Copyright © Harris Corporation 1994 (All rights reserved) Printed in U.S.A.. 7/1995 i | M00\ x YEARS z HARRIS See our specs in CAPS ISO9000 CERTIFIED ASSOCIATION LABORATORY Harris Semiconductor products are sold by description only. All specifications in this product guide are applicable only to packaged products; specifications for die are available upon request. Harris reserves the right to make changes in circuit design, specifications and other information at any time without prior notice. Accordingly, the reader is cautioned to verify that information in this publication is current before placing orders. Reference to products of other manufacturers are solely for convenience of comparison and do not imply total equivalency of design, performance, or otherwise. SEMICONDUCTOR ii FOR COMMERCIAL AND MILITARY APPLICATIONS General Information I Transient Suppression - Devices and Principles | Varistors - Basic Properties, Terminology and Theory Varistor Products Quality and Reliability Designing With Varistors Varistor Testing Surgector Products Integrated Protection Circuits Suppression - Telecommunication Systems Suppression - Automotive Transients Application Notes High Reliability Series How to Use Harris AnswerFAX Sales Offices Index (5) SEMICONDUCTOR TECHNICAL ASSISTANCE Harris Marketing Support Services (HMSS), 1-800-4HARRIS HMSS provides world-class service to customers requiring information on all products offered by Harris Semiconductor. Ask Harris Marketing Support Services for answers concerning: • Product Identification • Distributor Stocking Levels • Availability • Requests for Literature and Samples • Competitive and Obsolete Cross-Reference HMSS services are available from 8:00am to 8:00pm EST. Callers from outside the United States, dial (407) 727-9207. HMSS is the initial contact for customers who need technical assistance with the selection and use of our products. Callers have the option to be connected directly to the Central Applications Group. Central Applications, 1-800-4HARRIS Ask our experienced staff of engineers for assistance with: • Device Selection • Specification Interpretation • Applications for Any Harris Product Central Applications serves you Monday through Thursday 8:00am to 7:00pm and Friday 8:00am to 5:00pm EST. Callers from outside the United States dial (407) 727-9207. Central Applications' knowledge of our portfolio can provide you with a total system design solution using the latest Harris devices! Electronic Technical Support Electronic services from Harris Semiconductor offer you the most current information possible. ww w.sem i. harris.com http://www.semi.harris.com • Latest Literature Revisions • New Product Listing • Product Information • Design Support • Contact Information SEMICONDUCTOR ANSWER EAX (407) 724-7800 • Latest Literature Revisions • New Product Listing • Data Book Request Form CENTRAL APPLICATIONS EMAIL centapp@harris.com • Technical Application Assistance See our specs in CAPS % C0RP . /100\ J2 HARRIS TVS GENERAL INFORMATION PAGE ALPHA NUMERIC PRODUCT INDEX 1-3 PRODUCT INDEX BY FAMILY 1-4 MOV INDEX 1-5 VOLTAGE TRANSIENTS - AN OVERVIEW 1-11 Repeatable Transients 1-11 Random Transients 1-13 Transients on AC Power Lines 1-13 Telecommunication Line Transients 1-14 Automobile Transients 1-14 Effects of Voltage Transients 1-15 Transient Detection 1-16 Previous and Future Surge Recordings 1-17 Transient Testing and Standards 1-18 References 1-18 THE DEVELOPMENT OF A GUIDE ON SURGE VOLTAGES IN LOW-VOLTAGE AC POWER CIRCUITS 1-19 Introduction 1-19 The Origins of Surge Voltages 1-19 Rate of Occurrence and Voltage Levels In Unprotected Circuits 1-19 Waveshape of Representative Surge Voltages 1-20 Energy and Source Impedance 1-21 _i O < b cr < uj 2 z rr ui o C3 ll 1-1 Alpha Numeric Product Index PAGE AS Series High Energy Metal-Oxide Arrester Blocks 4-11 Automotive AUML Series Multilayer Transient Surface Mount Surge Suppressors 4-14 BA/BB Series Industrial High Energy Metal-Oxide Varistors 4-22 "C" III Series Radial Lead Metal-Oxide Varistors 4-26 CA Series Industrial High Energy Metal-Oxide Disc Varistors 4-34 CH Series Surface Mount Metal-Oxide Varistors 4-39 CP Series Connector Pin Metal-Oxide Varistors 4-43 C S Series Connector Pin Metal-Oxide Varistors 4-48 DA/DB Series Industrial High Energy Metal-Oxide Varistors 4-51 HA Series Industrial High Energy Metal-Oxide Varistors 4-55 z HIP1090 Protected High Side Power Switch with Transient Suppression 9-16 LA Series UL Recognized Radial Lead Metal-Oxide Varistors for Line Voltage Operation 4-59 £ g MA Series Axial Lead Metal-Oxide Varistors 4-69 2 o C5 Lu ML Series Multilayer Surface Mount Transient Surge Suppressors 4-74 NA Series Industrial High Energy Metal-Oxide Square Varistors 4-83 PA Series Base Mount Metal-Oxide Varistors 4-87 RA Series Low Profile Metal-Oxide Varistors 4-91 SGT03U13 Unidirectional Transient Surge Suppressors (SURGECTOR™) 8-3 SGT06U13 Unidirectional Transient Surge Suppressors (SURGECTOR™) 8-3 SGT1 0S1 Gate Controlled Unidirectional Transient Surge Suppressors 8-6 SGT21B13 Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT21B13A Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT22B13 Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT22B13A Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT23B13 Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT23B13A Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT23U13 Unidirectional Transient Surge Suppressors (SURGECTOR™) 8-3 SGT27B13 Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT27B13A Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT27B13B Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT27B27 Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-14 SGT27B27A Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-14 SGT27B27B Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-14 SGT27S10 Gate Controlled Unidirectional Transient Surge Suppressors 8-6 SGT27S23 Gate Controlled Unidirectional Transient Surge Suppressor (SURGECTOR™) 8-18 SP710 Protected Power Switch with Transient Suppression 9-3 SP720 Electronic Protection Array for ESD and Over- Voltage Protection 9-6 SP720MD-8 High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP720MD High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP720MM-8 High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP720MM High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP721 Electronic Protection Array for ESD and Over- Voltage Protection 9-11 ZA Series Radial Lead Metal-Oxide Varistors for Low-to-Medium Voltage Operation 4-98 1-3 Product Index by Family PAGE HIGH RELIABILITY SERIES DESC Qualified Parts List (QPL) MIL-R-83530 13-3 DESC Standard Military Drawing # 87063 13-5 DESC Standard Military Drawing # 90065 13-7 Harris High Reliability Series TX Equivalents 13-7 SP720MD-8, SP720MD, High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP720MM-8, SP720MM INTEGRATED PROTECTION CIRCUITS SP710 Protected Power Switch with Transient Suppression 9-3 SP720 Electronic Protection Array for ESD and Over- Voltage Protection 9-6 SP721 Electronic Protection Array for ESD and Over-Voltage Protection 9-11 HIP1090 Protected High Side Power Switch with Transient Suppression 9-16 SURGECTOR PRODUCTS SGT03U13, SGT06U13, Unidirectional Transient Surge Suppressors (SURGECTOR™) 8-3 SGT23U13 SGT1 0S1 0, SGT27S1 Gate Controlled Unidirectional Transient Surge Suppressors 8-6 SGT21B13.SGT21B13A, Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT22B13.SGT22B13A, SGT23B1 3, SGT23B1 3A, SGT27B13.SGT27B13A, SGT27B13B SGT27B27, SGT27B27A, Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-14 SGT27B27B SGT27S23 Gate Controlled Unidirectional Transient Surge Suppressor (SURGECTOR™) 8-18 VARISTOR PRODUCTS AS Series High Energy Metal-Oxide Arrester Blocks 4-11 Automotive AUML Series Multilayer Surface Mount Transient Surge Suppressors 4-14 BA/BB Series Industrial High Energy Metal-Oxide Varistors 4-22 "C" III Series Radial Lead Metal-Oxide Varistors 4-26 CA Series Industrial High Energy Metal-Oxide Disc Varistors 4-34 CH Series Surface Mount Metal-Oxide Varistors 4-39 CP Series Connector Pin Metal-Oxide Varistors 4-43 CS Series Connector Pin Metal-Oxide Varistors 4-48 DA/DB Series Industrial High Energy Metal-Oxide Varistors 4-51 HA Series Industrial High Energy Metal-Oxide Varistors 4-55 LA Series UL Recognized Radial Lead Metal-Oxide Varistors for Line Voltage Operation 4-59 MA Series Axial Lead Metal-Oxide Varistors 4-69 ML Series Multilayer Surface Mount Transient Surge Suppressors 4-74 NA Series Industrial High Energy Metal-Oxide Square Varistors 4-83 PA Series Base Mount Metal-Oxide Varistors 4-87 RA Series Low Profile Metal-Oxide Varistors 4-91 ZA Series Radial Lead Metal-Oxide Varistors for Low-to-Medium Voltage Operation 4-98 1-4 MOV Index MODEL NUMBER PAGE V302AS32 4-12 V402AS32 4-12 V502AS32 4-12 V602AS32 4-12 V302AS42 4-12 V402AS42 4-12 V502AS42 4-12 V402AS60 4-12 V18AUMLA1210 4-15 V18AUMLA1812 4-15 V18AUMLA2220 4-15 V131BA60 4-23 V151BA60 4-23 V251BA60 4-23 V271BA60 4-23 V321BA60 4-23 V421BA60 4-23 V481BA60 4-23 V511BA60 4-23 V571BA60 4-23 V661BA60 4-23 V751BA60 4-23 V881BA60 4-23 V112BB60 4-23 V142BB60 4-23 V172BB60 4-23 V202BB60 4-23 V242BB60 4-23 V282BB60 4-23 V130LA10C 4-27 V130LA20C 4-27 MODEL NUMBER PAGE V130LA20CX325 4-27 V140LA10C 4-27 V140LA20C 4-27 V140LA20CX340 4-27 V150LA10C 4-27 V150LA20C 4-27 V150LA20CX360 4-27 V175LA10C 4-27 V1 75LA20C 4-27 V175LA20CX425 4-27 V230LA20C 4-27 V230LA40C 4-27 V230LA40CX570 4-27 V250LA20C 4-27 V250LA40C 4-27 V250LA40CX620 4-27 V275LA20C 4-27 V275LA40C 4-27 V275LA40CX680 4-27 V300LA20C 4-27 V300LA40C 4-27 V300LA40CX745 4-27 V320LA20C 4-27 V320LA40C 4-27 4-35 V131CA40 4-35 V151CA32 4-35 V151CA40 4-35 V251CA32 4-35 V251CA40 4-35 V251CA60 4-35 MODEL NUMBER PAGE V271CA32 4-35 V271CA40 4-35 V271CA60 4-35 V321CA32 4-35 V321CA40 4-35 V321CA60 4-35 V421CA32 4-35 V421CA40 4-35 V421CA60 4-35 V481CA32 4-35 V481CA40 4-35 V481CA60 4-35 V511CA32 4-35 V511CA40 4-35 V511CA60 4-35 V571CA32 4-35 V571CA40 4-35 V571CA60 4-35 V661CA32 4-35 V661CA40 4-35 V661CA60 4-35 V751CA32 4-35 V751CA40 4-35 V751CA60 4-35 V881CA60 4-35 V112CA60 4-35 V142CA60 4-35 V172CA60 4-35 V202CA60 4-35 V242CA60 4-35 V282CA60 4-35 1-5 MOV Index MODEL NUMBER PAGE MODEL NUMBER PAGE MODEL NUMBER PAGE V22CH8 4-40 V26CS22 4-49 V271HA40 4-56 V27CH8 4-40 V31CS22 4-49 V321HA32 4-56 V33CH8 4-40 V38CS22 4-49 V321HA40 4-56 V39CH8 4-40 V131DA40 4-52 V421HA32 4-56 V47CH8 4-40 V131DB40 4-52 V421HA40 4-56 V56CH8 4-40 V151DA40 4-52 V481HA32 4-56 V120CH8 4-40 V151DB40 4-52 V481HA40 4-56 V150CH8 4-40 V251DA40 4-52 V511HA32 4-56 V180CH8 4-40 V251DB40 4-52 V511HA40 4-56 V200CH8 4-40 V271 DA40 4-52 V571HA32 4-56 V220CH8 4-40 V271DB40 4-52 V571 HA40 4-56 V240CH8 4-40 V321DA40 4-52 V661HA32 4-56 V360CH8 4-40 V321DB40 4-52 V661HA40 4-56 V390CH8 4-40 V421DA40 4-52 V751HA32 4-56 V430CH8 4-40 V421DB40 4-52 V751HA40 4-56 V8CP22 4-44 V481DA40 4-52 V130LA1 4-60 V14CP22 4-44 V481DB40 4-52 V130LA2 4-60 V31CP22 4-44 V511DA40 4-52 V130LA5 4-60 V38CP22 4-44 V511DB40 4-52 V130LA10A 4-60 V130CP22 4-44 V571DA40 4-52 V130LA20A 4-60 V150CP22 4-44 V571DB40 4-52 V130LA20B 4-60 V31CP20 4-44 V661DA40 4-52 V140LA2 4-60 V38CP20 4-44 V661DB40 4-52 V140LA5 4-60 V130CP20 4-44 V751DA40 4-52 V140LA10A 4-60 V150CP20 4-44 V751DB40 4-52 V140LA20A 4-60 V38CP16 4-44 V131HA32 4-56 V150LA1 4-60 V130CP16 4-44 V131HA40 4-56 V150LA2 4-60 V150CP16 4-44 V151HA32 4-56 V150LA5 4-60 V8CS22 4-49 V151HA40 4-56 V150LA10A 4-60 V14CS22 4-49 V251HA32 4-56 V150LA20A 4-60 V18CS22 4-49 V251HA40 4-56 V150LA20B 4-60 V22CS22 4-49 V271HA32 4-56 V175LA2 4-60 1-6 MOV Index MODEL NUMBER PAGE MODEL NUMBER PAGE MODEL NUMBER PAGE V175LA5 4-60 V420LA7 4-61 V33MA1A 4-70 V175LA10A 4-60 V420LA10 4-61 V33MA1B 4-70 V175LA20A 4-60 V420LA20A 4-61 V33MA1S 4-70 V230LA4 4-60 V420LA40B 4-61 V39MA2A 4-70 V230LA10 4-60 V460LA7 4-61 V39MA2B 4-70 V230LA20A 4-60 V480LA7 4-61 V39MA2S 4-70 V230LA40A 4-60 V480LA10 4-61 V47MA2A 4-70 V250LA2 4-60 V480LA40A 4-61 V47MA2B 4-70 V250LA4 4-60 V480LA80B 4-61 V47MA2S 4-70 V250LA10 4-60 V510LA10 4-61 V56MA2A 4-70 V250LA20A 4-60 V510LA40A 4-61 V56MA2B 4-70 V250LA40A 4-60 V510LA80B 4-61 V56MA2S 4-70 V250LA40B 4-60 V575LA10 4-61 V68MA3A 4-70 V275LA2 4-60 V575LA40A 4-61 V68MA3B 4-70 V275LA4 4-60 V575LA80B 4-61 V68MA3S 4-70 V275LA10 4-60 V625LA10 4-61 V82MA3A 4-70 V275LA20A 4-60 V625LA40A 4-61 V82MA3B 4-70 V275LA40A 4-60 V625LA80B 4-61 V82MA3S 4-70 V275LA40B 4-60 V660LA10 4-61 V100MA4A 4-70 V300LA2 4-61 V660LA50A 4-61 V100MA4B 4-70 V300LA4 4-61 V660LA100B 4-61 V1 00MA4S 4-70 V300LA10 4-61 V1000LA80A 4-61 V120MA1A 4-70 V300LA20A 4-61 V1000LA160B 4-61 V120MA2B 4-70 V300LA40A 4-61 V18MA1A 4-70 V120MA2S 4-70 V320LA7 4-61 V18MA1B 4-70 V150MA1A 4-70 V320LA10 4-61 V18MA1S 4-70 V150MA2B 4-70 V320LA20A 4-61 V22MA1A 4-70 V180MA1A 4-70 V320LA40B 4-61 V22MA1B 4-70 V180MA3B 4-70 V385LA7 4-61 V22MA1S 4-70 V220MA2A 4-70 V385LA10 4-61 V27MA1A 4-70 V220MA4B 4-70 V385LA20A 4-61 V27MA1B 4-70 V270MA2A 4-70 V385LA40B 4-61 V27MA1S 4-70 V270MA4B 4-70 1-7 MOV Index MODEL NUMBER PAGE MODEL NUMBER PAGE MODEL NUMBER PAGE V330MA2A 4-70 V511NA34 4-84 V56RA8 4-92 V330MA5B 4-70 V571NA34 4-84 V68RA8 4-92 V390MA3A 4-70 V661NA34 4-84 V82RA8 4-92 V390MA6B 4-70 V751NA34 4-84 V100RA8 4-92 V430MA3A 4-70 V130PA20A 4-88 V120RA8 4-92 V430MA7B 4-70 V130PA20C 4-88 V1 50RA8 4-92 V3.5MLA0805 4-75 V150PA20A 4-88 V180RA8 4-92 V3.5MLA0805L 4-75 V150PA20C 4-88 V200RA8 4-92 V3.5MLA1206 4-75 V250PA40A 4-88 V220RA8 4-92 V5.5MLA0805 4-75 V250PA40C 4-88 V240RA8 4-92 V5.5MLA0805L 4-75 V275PA40A 4-88 V270RA8 4-92 V5.5MLA1206 4-75 V275PA40C 4-88 V360RA8 4-92 V14MLA0805 4-75 V320PA40A 4-88 V390RA8 4-92 V14MLA0805L 4-75 V320PA40C 4-88 V430RA8 4-92 V14MLA1206 4-75 V420PA40A 4-88 V18RA16 4-93 V18MLA0805 4-75 V420PA40C 4-88 V22RA16 4-93 V18MLA0805L 4-75 V480PA80A 4-88 V27RA16 4-93 V18MLA1206 4-75 V480PA80C 4-88 V33RA16 4-93 V18MLA1210 4-75 V510PA80A 4-88 V39RA16 4-93 V26MLA1206 4-75 V510PA80C 4-88 V47RA16 4-93 V26MUA1210 4-75 V575PA80A 4-88 V56RA16 4-93 V33MLA1206 4-75 V575PA80C 4-88 V68RA16 4-93 V42MLA1206 4-75 V660PA100A 4-88 V82RA1 6 4-93 V56MLA1206 4-75 V660PA100C 4-88 V100RA16 4-93 V68MLA1206 4-75 V8RA8 4-92 V120RA16 4-93 V131NA34 4-84 V12RA8 4-92 V150RA16 4-93 V151NA34 4-84 V18RA8 4-92 V180RA16 4-93 V251NA34 4-84 V22RA8 4-92 V200RA16 4-93 V271NA34 4-84 V27RA8 4-92 V220RA16 4-93 V321NA34 4-84 V33RA8 4-92 V240RA16 4-93 V421NA34 4-84 V39RA8 4-92 V270RA16 4-93 V481NA34 4-84 V47RA8 4-92 V360RA16 4-93 1-8 V390RA16 4-93 V430RA16 4-93 V24RA22 4-93 V36RA22 4-93 V200RA22 4-93 V240RA22 4-93 V270RA22 4-93 V390RA22 4-93 V430RA22 4-93 V8ZA05 4-99 V8ZA1 4-99 V8ZA2 4-99 V12ZA05 4-99 V12ZA1 4-99 V12ZA2 4-99 V18ZA05 4-99 V18ZA1 4-99 V18ZA2 4-99 V18ZA3 4-99 V18ZA40 4-99 V22ZA05 4-99 V22ZA1 4-99 V22ZA2 4-99 V22ZA3 4-99 V24ZA50 4-99 V27ZA05 4-99 V27ZA1 4-99 V27ZA2 4-99 V27ZA4 4-99 V27ZA60 4-99 V33ZA05 4-99 V33ZA1 4-99 V33ZA2 4-99 V33ZA5 4-99 V33ZA70 4-99 V36ZA80 4-99 V39ZA05 4-99 V39ZA1 4-99 V39ZA3 4-99 V39ZA6 4-99 V39ZA20 4-99 V47ZA05 4-100 V47ZA1 4-100 V47ZA3 4-100 V47ZA7 4-100 V47ZA20 4-100 V56ZA05 4-100 V56ZA2 4-100 V56ZA3 4-100 V56ZA8 4-100 V56ZA20 4-100 V68ZA05 4-100 V68ZA2 4-100 V68ZA3 4-100 V68ZA10 4-100 V68ZA20 4-100 V82ZA05 4-100 V82ZA2 4-100 V82ZA4 4-100 V82ZA12 4-100 V100ZA05 4-100 V100ZA3 4-100 V100ZA4 4-100 V100ZA15 4-100 V120ZA05 4-100 V120ZA1 4-100 V120ZA4 4-100 V120ZA6 4-100 V120ZA20 4-100 V150ZA05 4-100 V150ZA1 4-100 V150ZA4 4-100 V150ZA8 4-100 V150ZA20 4-100 V180ZA05 4-101 V180ZA1 4-101 V180ZA5 4-101 V180ZA10 4-101 V180ZA20 4-101 V205ZA05 4-101 V220ZA05 4-101 V240ZA05 4-101 V270ZA05 4-101 V330ZA05 4-101 V360ZA05 4-101 V390ZA05 4-101 V430ZA05 4-101 V470ZA05 4-101 V620ZA05 4-101 V680ZA05 4-101 V715ZA05 4-101 V750ZA05 4-101 —I 2 < b cc < Z EC Ui O O LL 1-9 Voltage Transients - An Overview To treat any problem, the scope of the problem must first be established. This section is an overview of the sources and nature of transient overvoltages, the problems they can cause and the equipment for testing and monitoring them. Transients in electrical circuits result from the sudden release of previously stored energy. This energy can be stored within the circuit and released by a voluntary or con- trolled switching action or it can be stored outside the circuit and be injected or coupled into the circuit of interest by some action beyond the control of the circuit designer. Transients may occur either in repeatable fashion or as ran- dom impulses. Repeatable transients, such as commutation voltage spikes, inductive load switching, etc., are more eas- ily observed, defined and suppressed. Random transients are more elusive. They occur at unpredictable times, at remote locations, and require installation of monitoring instruments to detect their occurrence. Experience has been accumulated to provide reasonable guidelines of the tran- sient environments in low voltage AC power circuits,' 1 • 2 ' telecommunications equipment' 3 ' and automotive electrical systems.' 4 ' Effective transient overvoltage protection requires that the impulse energy be dissipated in the added suppressor at a voltage low enough to ensure the survival of circuit compo- nents. The following sections will discuss in detail the two categories of transients, how they occur, their effects and their detection. Repeatable Transients A sudden change in the electrical conditions of any circuit will cause a transient voltage to be generated from the energy stored in circuit inductance and capacitance. The rate of change in current (di/dt) in an inductor (L) will gener- ate a voltage equal to -L di/dt, and it will be of a polarity that causes current to continue flowing in the same direction. It is this effect that accounts for most switching-induced tran- sient overvoltages. It occurs as commutating spikes in power conversion circuits, when switching loads and under fault conditions. The effect is brief, since the source is limited to the energy stored in the inductance (1/2Li 2 ), and it is gen- erally dissipated at a high instantaneous power (Energy = power x time). But the simple effect of one switching opera- tion can be repeated several times during a switching sequence (consider arcing in the contact gap of a switch), so that cumulative effects can be significant. Energizing the Transformer Primary When a transformer is energized at the peak of the supply volt- age, the coupling of this voltage step function to the stray capacitance and inductance of the secondary winding can generate an oscillatory transient voltage with a peak amplitude up to twice the normal peak secondary voltage (Figure 1). LOAD SECONDARY VOLTAGE &RY I Vs-PK FIGURE 1. VOLTAGE TRANSIENT CAUSED BY ENERGIZING TRANSFORMER PRIMARY Subsequent oscillations depend on the L and C parameters of the circuit. Another important point to remember is that the secondary side will be part of a capacitive divider network in series with the transformer interwinding capacitance (C s ). This capacitively coupled voltage spike has no direct rela- tionship to the turns ratio of the transformer, so that it is con- ceivable that the secondary circuit can see a substantial fraction of the peak applied primary voltage. De-Energizing the Transformer Primary The opening of the primary circuit of a transformer generates extreme voltage transients, especially if the transformer drives a high impedance load. Transients in excess of ten times normal voltage have been observed across power semiconductors when this type of switching occurs. Interrupting the transformer magnetizing current, and the resulting collapse of the magnetic flux in the core, couples a high voltage transient into the transformer secondary wind- ing, as shown in Figure 2. 1-11 Voltage Transients - An Overview CLOSING SWITCH H6- -Wv- LOAD FIGURE 2. VOLTAGE TRANSIENT CAUSED BY INTERRUPTION OF TRANSFORMER MAGNETIZING CURRENT Unless a low-impedance discharge path is provided, this burst of transient energy appears across the load. If this load is a semiconductor device or capacitor with limited voltage capabilities, that component may fail. The transients pro- duced by interrupting the magnetizing current are usually quite severe. For example, the stored energy in the magne- tizing field of a 1 50kVA transformer can be 9J. Fault with Inductive Power Source If a short develops on any power system, devices parallel to the load may be destroyed as the fuse clears. FIGURE 3. VOLTAGE TRANSIENT CAUSED BY FUSE BLOW- ING DURING POWER FAULT When the fuse or circuit breaker of Figure 3 opens, it inter- rupts the fault currents causing the slightly inductive power source to generate a high voltage (-L di/dt), and high energy (1/2Li 2 ), transient across any parallel devices. Suddenly interrupting a high current load will have a similar effect. Switch Arcing When current in an inductive circuit, such as a relay coil or a filter reactor, is interrupted by a contactor, the inductance tries to maintain its current by charging the stray capaci- tance. Similar action can take place during a closing sequence if the contacts bounce open after the initial closing as in Figure 4. The high initial charging current will oscillate in the inductance and capacitance at a high frequency. When the voltage at the contact rises, breakdown of the gap is possible since the distance is still very small during the opening motion of the contact. The contact arc will clear at the current zero of the oscillation but it will restrike as the contact voltage rises again. As the contacts are moving far- ther apart, each restrike must occur at a higher and higher voltage until the contact succeeds in interrupting the current. FIGURE 4. VOLTAGE TRANSIENTS CAUSED BY SWITCH ARCING This restrike and escalation effect is particularly apparent in Figure 5, where a switch opens a relay coil of 1H, having about 0.001 |iF of distributed (stray) capacitance in the wind- ing. Starting with an initial DC current of a 100mA, the circuit produces hundreds of restrikes (hence, the "white" band on the oscillogram) at high repetition rate, until the circuit clears, but not before having reached a peak of 3kV in contrast to the initial 125V in the circuit. SB s a 3 HORIZONTAL -t, 500>is/DIV., VERTICAL -V, LOkV/DIV FIGURE 5. VOLTAGE ESCALATION DURING RESTRIKES Electromechanical contacts generate transients which they generally can survive. However, in the example just discussed, the 2.5ms long sequence of restrikes and attendant high current may be damaging to the contacts. Also, the transients injected into the power system during the restrike can be damaging to other loads. In an attempt to eliminate electromechanical switches and their arcing problem, solid-state switches are recommended with good reason! However, if these switches are applied without discrimination in inductive circuits, the very effectiveness of the interruption can lead to the generation of high voltage transients. 1-12 Voltage Transients - An Overview In the example of Figure 6, the transistor used for switching 400mA in a 70mH solenoid is exposed to 420V spikes, although the circuit voltage is only 150V. Whenever possible, a system should be examined for poten- tial sources of transient overvoltage so they can be elimi- nated at the source, for one source can affect many components. It the sources are many (or unidentifiable) and the susceptible components few, it may be more practical then to apply suppression at the components. 150VDC » 50ms/DIVISION FIGURE 6. TRANSISTOR SWITCHING TRANSIENT Random Transients Frequently, transient problems arise from the power source feeding the circuit. These transients create the most conster- nation because it is difficult to define their amplitude, dura- tion and energy content. The transients are generally caused by switching parallel loads on the same branch of a distribution system, although they also can be caused by lightning. Communication lines, such as alarm and tele- phone systems, are also affected by lightning and power system faults. To deal with random transients, a statistical approach has been taken to identify the nature of line overvoltages. While recordings of transients have been made, one cannot state that on a specific system there is an "X" probability of encountering a transient voltage of "Y" amplitude. Therefore, one is limited to quoting an "average" situation, while being well aware that large deviations from this average can occur, depending on the characteristics of the specific system. In the following sections, the recorded experiences of three types of systems will be described. These are: 1) AC power lines (up to 1000V); 2) telecommunication systems; and 3) automotive systems. Transients on AC Power Lines Data collected from various sources has provided the basis for this guide to transient overvoltages.' 1 • °- 6| 7j 8 ' Amplitude and Frequency of Occurrence The amplitude of transient recordings covers the range from harmless values just above normal voltage to several kilo- volts. For 120V AC lines, flashover of the typical wiring spac- ing produces an upper limit between 6kV and 8kV. Ironically, the better the wiring practices, the higher the flashover, allowing higher transients to exist in the wiring system. Stud- ies of the frequency of occurrence and amplitude agree on an upper limit and a relative frequency of occurrence. Figure 7 shows frequency as a function of amplitude. Experi- ence indicates that devices with less than 2kV withstand capability will have poor service life in the unprotected resi- dential environment. Prudent design will aim for 3kV capabil- ity, although, where safety is of the utmost concern, designing for 6kV can cope with these rare but possible occurrences. o 5 a in ■ 1.0 0.01 i % \ * % • • \ \ »X t — ^ * s> * \\ • * * * * • 1 * 0.2 0.4 0.6 1 2 4 6 10 PEAK VALUE OF VOLTAGE TRANSIENT kV , . SERVICE ENTRANCE OF BANK BUILDING IN BASEL, SWITZERLAND SERVICE ENTRANCE, 16 FAMILY HOUSE, UNDERGROUND SYSTEM (HEAD STATION). FARMHOUSE SUPPLIED BY OVERHEAD TRANSMISSION LINES. LANDIS AND GYR. PLANT, ZUG, OUTLET IN LAB. , _ _ 16 FAMILY HOUSE, UPSTAIRS LIVING ROOM OUTLET. LANDIS AND GYR., ZUG, OUTLET IN FURNACE ROOM (COURTESY OF L. REGEZ, LANDIS AND GYR., ZUG, SWITZERLAND). ' U.S. COMPOSITE CURVE. (220V) SERVICE (120V) SERVICE FIGURE 7. FREQUENCY OF OCCURRENCE OF TRANSIENT OVER-VOLTAGES IN 220V AND 120V SYSTEMS 1-13 Voltage Transients - An Overview For systems of higher voltages (220V, 240V, 480V), limited data is available for U.S. systems. However, the curves of Figure 8 indicate the difference between the two classes, 120V and 220V systems, is smaller than the differences within each class.' 8 ' One can conclude that the amplitude of the transient depends more upon the amount of externally coupled energy and the system impedance than upon the system voltage. o = 5ns — * -"""^T„ = 5ps ^ H = 1000ns T N = TIME TO HALF VALUE OF PEAK 100 200 300 400 500 RATED VOLTAGE OF DISTRIBUTION SYSTEM (V) FIGURE 8. SWITCHING VOLTAGE TRANSIENTS AS A FUNC- TION OF THE SYSTEM VOLTAGE FOR THREE VALUES OF THE TRANSIENT TAIL (TIME TO HALF-VALUE) - (DATA COURTESY OF L. REGEZ, LANDIS & GYR . ZAG, SWITZERLAND) For internal switching transients in the power system, Figure 8 shows the relationship (computed and measured) between system voltage and transient peaks.' 8 ' Clearly, there is no direct linear increase of the transient amplitude as the system voltage is increased. Some indication of the uncertainty concerning the expected transient level can be found in the industrial practice of choosing semiconductor ratings. Most industrial users of power semiconductors choose semiconductor voltage ratings from 2.0 to 2.5 times the applied peak steady-state voltage, in conjunction with rudimentary transient suppression, in order to ensure long-term reliability. Whether or not this ratio is realistically related to actual transient levels has not been established; the safety factor is simply chosen by experience. While it is dangerous to argue against successful experience, there are enough cases where this rule of thumb is insufficient and thus a more exact approach is justified. Another objection to the indiscriminate rule of thumb is economic. Specifying 2.5 times the peak system voltage results in a high price penalty for these components. It is normally unrealistic and uneconomical to specify semiconductors that should withstand transients without protection. The optimum situation is a combination of low cost transient protection combined with lower cost semiconductors having lower voltage ratings. Duration, Waveform and Source Impedance There is a lack of definitive data on the duration, waveform and source impedance of transient overvoltages in AC power circuits. These three parameters are important for estimating the energy that a transient can deliver to a suppressor. It is desirable to have a means of simulating the environment through a model of the transient overvoltage pulse. Suggestions have been made to use standard impulses initially developed for other applications. For instance, the classical 1.2 x 50\xs unidirectional voltage impulse specified in high voltage systems has been proposed.' 91 Also the repetitive burst of 1.5MHz oscillations ("SWC") specified for low-voltage and control systems exposed to transients induced by high-voltage disconnect switches in utility switch yards is another suggestion.' 10 ' Working Groups of the IEEE and the International Electrotechnical Commission have developed standard test waves and source impedance definitions. These efforts are aiming at moving away from a concept whereby one should duplicate environmental conditions and towards a concept of one standard wave or a few standard waves arbitrarily specified. The justifications are that equipments built to meet such standards have had satisfactory field experience and provide a relative standard against which different levels of protection can be compared. A condition for acceptance of these standard waves is that they be easy to produce in the laboratory.' 11 ' This is the central idea of the TCL (Transient Control Level) concept which is currently being proposed to users and manufacturers in the electronics industry. Acceptance of this concept will increase the ability to test and evaluate the reliability of devices and systems at acceptable cost. Telecommunication Line Transients Transient overvoltages occurring in telephone lines can usually be traced to two main sources: lightning and 50Hz/60Hz power lines. Lightning overvoltage is caused by a strike to the conductor of an open wire system or to the shield of a telephone cable. Most modern telephone lines are contained in shielded cables. When lightning or other currents flow on the shield of a cable, voltages are induced between the internal conductors and the shield.' 12 ' The magnitude of the induced voltages depend on the resistance of the shield material, openings in its construction, and on the dielectric characteristics and surge impedance of the cable. The close proximity of telephone cables and power distribu- tion systems, often sharing right-of-way-poles and even ground wires, is a source of transient overvoltages for the telephone system. Overvoltages can arise from physical contact of falling wires, electromagnetic induction, and ground potential rise. Section 10 of this data book presents a detailed discussion of lightning-induced and power system- induced transients. Automobile Transients Four principal types of voltage transients are encountered in an automobile. These are "load dump," alternator field decay, inductive switching and mutual coupling ' 4 ' In addi- tion, service "Jump starts" with 24V batteries may occur. The load dump transient is the most severe and occurs when the alternator current loading is abruptly reduced. The most demanding case is often initiated by the disconnection 1-14 Voltage Transients - An Overview of a partially discharged battery due to defective terminal connections. Transient voltages have been reported over 100V lasting up to 500ms with energy levels in the range of tens to hundreds of joules. Switching of inductive loads, such as motors and solenoids, will create negative polarity transient voltages with a smaller positive excursion. The voltage waveform has been observed to rise to a level of -210V and +80V and last as long as 320us. The impedance to the transient is unknown, leading some designers to test with very low impedance, resulting in the use of more expensive components than necessary. The alternator field decay transient is essentially an inductive load switching transient. When the ignition switch is turned off, the decay of the alternator field produces a negative voltage spike, whose amplitude is dependent on the voltage regulator cycle and load. It varies between -40V to -100V and can last 200ms. Other unexplained transients have been recorded with peaks of 600V upon engine shutdown. Furthermore, removal of regulation devices, particularly the battery, will raise normally innocuous effects to dangerous levels. For example, ignition pulses up to 75V and 90us in duration have been observed with the battery disconnected. Section 11 provides a comprehensive review of automotive transients and practical suppression techniques to protect automotive electronics. Effects of Voltage Transients Effects on Semiconductors Most semiconductor devices are intolerant of voltage tran- sients in excess of their voltage ratings. Even such a short- lived transient as a few microseconds can cause the semi- conductor to fail catastrophically or may degrade it so as to shorten its useful life. Frequently, damage occurs when a high reverse voltage is applied to a non-conducting PN junction. The junction may avalanche at a small point due to the non-uniformity of the electric field. Also, excess leakage current can occur across the passivated junction between the terminations on the die surface. The current can create a low resistance channel that degrades the junction blocking voltage capability below the applied steady-state voltage. In the avalanche case, thermal runaway can occur because of localized heating building up to cause a melt-through which destroys the junction. If the base-emitter junction of a transistor is repetitively "avalanched" or "zenered" to a high current level by a reverse pulse, the forward current gain may be degraded. The triggering sensitivity of a thyristor can be reduced in the same manner by "zenering" the gate-cathode junction. Thyristors can also be damaged if turned on by a high voltage spike (forward breakover) under bias conditions that allow a rate of current increase (di/dt) beyond device capability. This will occur in virtually all practical circuits because the discharge of the RC dv/dt protection circuits will exceed device capability for di/dt and destroy the thyristor. Effects on Electromechanical Contacts The high voltage generated by breaking current to an inductor with a mechanical switch will ultimately cause pitting, welding, material transfer, or erosion of the contacts. The nature of ultimate failure of the contacts depends upon such factors as the type of metal used, rate of opening, contact bounce, atmosphere, temperature, steady-state and inrush currents, and AC or DC operation. Perhaps most important is the amount of energy dissipated in each operation of the contacts. The actual breaking of current by a set of contacts is a complex operation. The ultimate break occurs at a microscopic bridge of metal which, due to the inductive load, is forced to carry nearly all the original steady-state current. Ohmic heating of this bridge causes it to form a plasma, which will conduct current between the contacts when supplied with a current and voltage above a certain threshold. The inductor, of course, is more than happy to supply adequate voltage (E L = -L di/dt). As the contacts separate and the current decreases, a threshold is reached, and the current stops abruptly ("chopping"). Inductor current then charges stray capacitances up to the breakdown voltage of the atmosphere between the contacts. (For air, this occurs at 30kV/in.) The capacitance discharges and recharges repeatedly until all the energy is dissipated. This arc causes sufficient contact heating to melt, oxidize, or "burn" the metal, and when the contacts close again, the contacts may form a poorer connection. If they "bounce," or are closed soon after arcing, the contacts may be sufficiently molten to weld closed. Welding can also occur as a result of high inrush currents passing through the initially formed bridges upon closing. Good suppression techniques can significantly reduce the amount of energy dissipated at the contacts, with a propor- tional increase in operating life. Suppression can also reduce the noise generated by this arcing. Voltage-limiting devices are particularly suited to preventing the noisy high- voltage "showering" arc described above and illustrated in Figure 4. Effects on Insulation Transient overvoltages can cause breakdown of insulation, resulting in either a temporary disturbance of device opera- tion or instantaneous failure. The insulating level in the former case will be weakened leading to premature failure. The severity of the breakdown varies with the type of insula- tion air, liquid, or solid. The first two tend to be self-healing, while breakdown of solid insulation (generally organic mate- rials) is generally a permanent condition. Air clearances between metal parts in electrical devices and power wiring constitute air gaps, which behave according to the usual physics of gap breakdown (pressure, humidity, shape of electrodes, spacing). The International Electrotech- nical Commission Working Group on Low Voltage Insulation Coordination has developed a table listing the minimum clearances in air for optimum and worst case electric field conditions existing between electrodes.' 1 31 Breakdown of the clearance between metal parts can be viewed as a form of 1-15 Voltage Transients - An Overview protection, limiting the overvoltage on the rest of the circuit. However, this protection is dependent upon the likelihood of AC line current that may follow during the arc breakdown. Normally, power-follow current should cause the system fuse or breaker to function. If the power-follow current heat is limited by circuit impedance, then the system fusing may not operate. In that case, sufficient heat could be generated to cause a fire. Experience with power wiring has shown that metal clearances can flash-over harmlessly under transient voltage conditions, and power-follow problems are rare, but can occur. In liquid dielectrics, an impulse breakdown not followed by a high current is normally harmless. However, this type of breakdown is of limited interest in low-voltage systems, where liquid insulation systems are seldom used, except in combination with some degree of solid insulation. Breakdown of solid insulation generally results in local car- bonization of an organic material. Inorganic insulation mate- rials are generally mechanically and permanently damaged. When no power-follow current takes place, the system can recover and continue operating. However, the degraded insulating characteristic of the material leads to breakdown at progressively lower levels until a mild overvoltage, even within AC line overvoltage tolerances, brings about the ulti- mate permanent short circuit. Since the final failure can occur when no transients are present, the real cause of the problem may be concealed. Breakdown along surfaces of insulation is the concern of "creepage" specifications. The working group of I EC cited above is also generating recommendations on creepage dis- tances. The behavior of the system where creepage is con- cerned is less predictable than is breakdown of insulation in the bulk because the environment (dust, humidity) will deter- mine the withstand capability of the creepage surface. When considering the withstand capabilities of any insula- tion system, two fundamental facts must be remembered. The first is that breakdown of insulation is not instantaneous but is governed by the statistics of avalanche ionization. Hence there is a "volt-time" characteristic, which challenges the designer to coordinate protection systems as a function of the impinging waveshape. The second is that the distribu- tion of voltage across insulation is rarely linear. For example, a steep wave front produces a piling up of voltage in the first few turns of a motor winding, often with reflections inside the winding. Also, the breakdown in the gap between the elec- trodes, initiating at the surface, is considerably dependent upon the overall field geometry, as well as on macroscopic surface conditions. Effects on Power Consumption As a result of the increasing emphasis on energy conserva- tion, a number of transient voltage suppression devices have been offered for sale as energy savers. The premise seems to be that transient overvoltages would cause degra- dation of electrical equipment leading to increased losses and thus to a waste of energy. No convincing proof has been offered to support this claim, and injunctions against making such claims have been obtained in several states.' 14 ' Noise Generation With the proliferation of low level logic circuits, electrical noise problems are of concern, especially in environments with electromechanical devices. Noise can upset automatic manufacturing equipment, medical equipment, computers, alarms and thyristor-controlled machinery. Such disruption can cause loss of product, time, money, and even human life. Noise enters a system either directly on wires or grounds connected to the source or through coupling to adjacent wires. Noise problems are dealt with by suppression at the source, at the receiver, or by isolation. Noise is induced when stray capacitance or mutual inductance links the sus- ceptible system to the noise-generating system. The ampli- tude of the induced noise is then related to the rate-of- change of either the current or the voltage of the noise source. The low-frequency components of the induced noise (which are hardest to filter out) are a result of the amplitude of the original transient impulses. Frequently, the source of noise is the arcing of contacts breaking current through an inductor, such as a relay coil. A low-current, high-voltage arc creates a series of brief dis- charges of a damped oscillatory nature, occurring at kHz to MHz frequencies with amplitudes of from 300V to several thousand volts. These pulses and their reflections from loads and line discontinuities travel along the power wires, easily inducing noise in adjacent wiring. This interference is best eliminated by preventing it at the source (the induc- tance) with voltage-limiting devices such as varistors. Rate of Rise vs Amplitude Interference coupled into electronic systems, as opposed to damage, is most often associated with the rate of rise of the interfering signal rather than its peak amplitude. Conse- quently, low-amplitude fast-rise interference which is dealt only by the capacitance of a varistor until the clamping level is reached by the impinging interference may still be a prob- lem with the circuit if attempts are made to suppress it with a retrofit varistor at the location of the victim. A much more effective cure would be to install the appropriate varistor near the source of the offending surge, so that the interfer- ence radiated or coupled by the surge would be confined to the immediate vicinity of the offending source. Transient Detection Voltage transients are brief and unpredictable. These two characteristics make it difficult to detect and measure them. Even transients described earlier in this section as "repeat- able" are subject to variations resulting from the timing of the switching operation, the erratic bouncing of contacts, and other random combinations. The transient detector par excellence is the high-frequency storage oscilloscope, but its cost limits its availability. Cus- tom systems have been built to monitor transients on loca- tion, n s ' 16 l but cost has been a limiting factor in this method of detection as well. A conventional oscilloscope with high- frequency response can be used as a monitor if it is provided 1-16 Voltage Transients - An Overview with single-sweep controls for monitoring transients occur- ring at random times but at relatively low frequent rates. The operator sets the trigger controls at some threshold level in single-sweep mode and watches the "ready" light on the oscilloscope panel while a camera with open shutter records the screen display. The film is pulled after the operator notices that sweep occurred and, thus, a record is obtained. While not very efficient for extensive monitoring, this method is very effective for short-term panics, the most frequent situ- ation when transients are suspected. Digital storage oscillo- scopes with automatic data transfer to a magnetic disc are now available for unattended monitoring. In recent years, leading oscilloscope manufacturers have developed improved versions of storage oscilloscopes and high-frequency, high sampling rate digital oscilloscopes. The experienced engineer can put them to work and obtain satis- factory recordings by the technique described above, using normal safeguards against erroneous recordings (check on noise background, stray ground currents, radiation of noise into preamplifier circuits, high frequency response limitations in differential mode, etc.). A wide variety of suitable analog or digital test instruments is commercially available. These allow economical monitoring of a remote location by providing various degrees of storage (single-event recording, counting above a threshold, digital memory for playback, etc.). Trade magazines and engineering papers have also described a number of homemade detectors. While these are undoubtedly performing to the satisfaction of their cre- ators, one can question the economic wisdom of investing time and engineering resources to duplicate, debug, validate and calibrate a homemade device when so many commer- cial units offering well demonstrated and credible perfor- mance are available. Previous and Future Surge Recordings The supporting data cited in the IEEE Guide on Surge Volt- ages, ANSI/IEEE C62-41-1980, are based on voltage surge recordings made in the 1962-1965 period. In that period, dig- ital instrumentation for surge monitoring was not as readily available as it is now, and, most significantly, the proliferation of surge protective devices, such as metal oxide varistors, had not reached the present level. Measurements, limited to voltage, were conducted with oscilloscope/camera systems or with peak-recording instru- ments. Voltages were generally recorded between the line(s) and the neutral of a single-phase or polyphase power sys- tem. No measurements had been reported as neutral-to- ground; some may have been between line and ground. Of course, that distinction is moot for measurements made at the service entrance where neutral and ground are bonded. An estimate of the number of low-voltage surge protective devices such as varistors used in the United States since 1972 on AC power circuits is in the order of 500 million. An undefined but substantial portion of that number is installed in permanently connected equipment. Therefore, it is now very likely that a new limitation exists in the recording of volt- age surges. A surge recording instrument installed indiscrim- inately at a random location may have a varistor connected across the line near the point being recorded. I 17 ' This situa- tion will have several implications for the recordings obtained in present and future measurements, as contrasted to those of previous measurement campaigns. 1 . Locations where voltage surges were previously identified assuming no change in the source of surges are now like- ly to experience lower voltage surges, while current surg- es will occur in the newly installed protective devices. 2. Not only will the peaks of the observed voltages be changed, but also their waveforms will be affected by the presence of nearby varistors as follows: a. If a varistor is located between the source of the surge and the recording instrument, the instrument will record the clamping voltage of the varistor. This voltage will have lower peaks but longer time to half- peak than the original surge. b. If the instrument is located between the source of the surge and a varistor, or if a varistor is installed in a parallel branch circuit, the instrument will record the clamping voltage of the varistor, preceded by a spike corresponding to the inductive drop in the line sup- plying surge current into the varistor. c. If a varistor is connected between line and neutral with a surge impinging between line and neutral at the service entrance, a new situation is created: the line-to-neutral voltage is indeed clamped as intended, but the inductive drop in the neutral con- ductor between the point of connection of the varistor and the service entrance creates a spike voltage between the neutral and the grounding connector at the point of connection of the varistor and down- stream points supplied by the same neutral. Because this spike will have a short duration, it will be enhanced by the open-end transmission line effect between the neutral and grounding conductors.' 18 ' 3. The surge voltage limitation function performed by flash- over of clearances is more likely to be assumed by new surge protective devices that are constantly being added to the systems. 4. The considerations discussed in paragraphs 1 , 2, and 3 above will produce a significant reduction in the mean of recorded voltage surges in a population of different loca- tions. This reduction will continue as more and more varistors are installed. The upper limit, however, will re- main the same for locations where no varistor has yet been installed. A sense of false security and an incorrect description of the environment might be created by atten- tion given only to the average of voltage surges presently recorded in power systems. Furthermore, the need for adequate surge current handling capability of a new can- didate surge suppressor might be underestimated if par- tial surge diversion is already being performed by a nearby varistor. This risk will be exacerbated if an attempt is made to clamp at lower voltages by the installation of a new protective device with a clamping voltage lower than that of the device already installed. 11 §l 1-17 Voltage Transients - An Overview Transient Testing and Standards It is desirable to have test criteria and definitions that provide a common engineering language beneficial to both the user and manufacturer of surge protective devices. Regret- fully, different terms have come into use through industry practice over the years. Testing standards have tended to proliferate as the measurement objective defines either the characteristics of the protective device or the environment of the application. The characteristics of each surge protection device will vary according to its basic construction. Protective devices are diverse, being based on ionized gas breakdown, semiconductor junction breakdown, and "charge hopping" conduction. For this reason, it seems sensible to group devices by physical category and set up pertinent standards that are suitable for characterizing their behavior. The standards would use appropriate stress levels and measure those parameters that are critical to ensuring proper performance. The application environment has demanded different condi- tions of transient levels. Standards vary depending on sys- tem usage, whether protection is intended for power lines, telecommunications, automotive, or aircraft, to name a few. Each environment also has been defined with less than full precision leading to additional diversity on choice of wave- shape, amplitude and duration. Several organizations such as ANSI/IEEE, IEC, UL, NEMA are currently developing guidelines and standards to describe what the environment is likely to be, on the basis of accumulated recording and field experience. From this, test specifications are being prepared 120 ' 21 ■ 22 ' 231 that will allow objectives are realistic evaluation of suppressor applications. References [1] Martzloff, F.D., The Development of a Guide on Surge Voltages in Low-Voltage AC Power Circuits," Report 81 CRD047, General Electric, Schenectady, New York 1981 . [2] Greenwood, Allan, "Electrical Transients in Power Sys- tems", Wiley-lnterscience, New York, 1971. [3] Bodle, D.W., A.J. Ghaze, M. Syed and R.L. Woodside, "Characterization of the Electrical Environment," Toronto: University of Toronto Press, 1 970. [4] "Recommended Environmental Practices for Electronic Equipment Design," Publication SAEJ1211, Society of Automotive Engineers, Warrendale, Pennsylvania. [5] Hahn, G.J. and F.D. Martzloff, "Surge Voltages in Resi- dential and Industrial Power Circuits," IEEE Trans. PAS- 89, No. 6, July-Aug. 1970, pp. 1049-1056. [6] Bull, J.H., "Voltage Spikes in L. V. Distribution Systems and Their Effects on the Use of Electronic Control Equip- ment," Report No. 5254, Electrical Research Assn., Cleeve Rd., Leatherhead, Surrey, Great Britain, 1968. [7] EEE Surge Protective Devices Committee, "Bibliogra- phy on Surge Voltages in AC Power Circuits Rated 600 Volts or Less," IEEE Trans. PAS-89, No. 6, July-Aug. 1970, pp. 1056-1061. [8] Data contributed by L. Regez (Landis & Gyr. Co., Zug, Switzerland), Swiss representative to IEC Working Group 28A on Low Voltage Insulation Coordination. [9] "Surge Arresters for Alternating Current Power Circuits," ANSI Standard C62.1, IEEE Standard 28,1974. [10] "Guide for Surge Withstand Capability (SWC) Test," ANSI Standard C37.90a, 1974, IEEE Standard 472,1974. [11] Martzloff, F.D. and F.A. Fisher, Transient Control Level- Philosophy and Implementation The Reasoning Behind the Philosophy," 77CH1224-SEMC, Proceedings of the 2nd Symposium on EMC, Montreux, June 1977. [1 2] Fisher, F.A., "A Way to Evaluate the Effects of Changing Magnetic Fields on Shielded Conductors," Report 77CRD158, General Electric, Schenectady, New York, July 1977. [13] "Insulation Co-ordination Within Low- Voltage Systems, including Clearances and Creepage Distances for Equipment," IEC Report 664,1980. [14] "Evaluation of Transient Voltage Suppressors for Sav- ing Electric Energy," EPRI EM- 1722, February 1981. [15] Allen, George W., "Design of Power-Line Monitoring Equipment," IEEE Trans. PAS-90, No. 6, Nov-Dec. 1971, pp.2604-2609. [1 6] Herzog, R., "How to Catch a Transient" Machine Design Magazine, March 1973, pp. 170-175. [1 7] Martzloff, F.D., Discussion of paper "Rural Alaska Electric Power Quality," IEEE Transactions on Power Apparatus and Systems PAS-104, No. 3, pp. 618-619, March 1985. [18] Martzloff, F.D. and Gauper, H.A., "Surge and High Fre- quency Propagation in Industrial Power Lines," 85CRD087,General Electric Company, Schenectady, New York, 1985. [19] Martzloff, F.D., "Varistor versus Environment: Winning the Rematch," IEEE/PES Summer Meeting, 1985 Scheduled for IEEE Transaction on Power Apparatus and System, 1986. [20] "IEEE Standard Test Specifications for Gas Tube Surge-Protective Devices," ANSI/IEEE C62.3 1-1981. [21] "IEEE Standard Test Specifications for Low-Voltage Air Gap Surge-Protective Devices (Excluding Valve and Expulsion Type Devices)," ANSI/IEEE C62.32- 1981. [22] "IEEE Standard Test Specifications for Varistor Surge- Protective Devices," ANSI/IEEE C62.33- 1982. [23] "IEEE Standard Test Specifications for Avalanche Junc- tion Semiconductor Surge-Protective Devices," IEEE C62.34-1984. 1-18 The Development of a Guidef on Surge Voltages in Low- Voltage AC Power Circuits F.D. Martzloff, Fellow, IEEE Introduction Surge voltages occurring in AC power circuits can be the cause of misoperation or product failure for residential as well as industrial systems. The problem has received increased attention in recent years because miniaturized solid state devices are more sensitive to voltage surges (spikes and transients) than were their predecessors. Although surge voltage amplitudes and their frequency of occurrence on unprotected circuits are well known, their waveshapes and energy content are less well known. On the basis of measurements, statistics, and theoretical considerations, a practical guide for outlining the environment for use in predicting extreme waveshapes and energy content can nevertheless be established. A Working Group of the Surge Protective Devices Committee has completed such a descriptive Guide.it The Guide proposes two waveforms, one oscillatory, the other unidirectional, depending on the location within the power system. It also includes recommendations for source impedance or short- circuit current. While the major purpose of the Guide is to describe the environment, a secondary purpose is to lead toward standard tests. The Origins of Surge Voltages Surge voltages occurring in low-voltage AC power circuits originate from two major sources: system switching transients and direct or indirect lightning effects on the power system. System switching transients can be divided into transients associated with (1) major power system switching disturbances, such as capacitor bank switching; (2) minor switching near the point of interest, such as an appliance turnoff in a household or the turnoff of other loads in an individual system; (3) resonating circuits associated with switching devices, such as thyristors; and (4) various system faults, such as short circuits and arcing faults. Measurements and calculations of lightning effects have been made to yield data on what levels can be produced, even if the exact mechanism of any particular surge is unknown. While the data have been recorded primarily on 120, 220/380, or 277/480V systems, the general conclusions should be valid for 600V systems. To the extent that surge voltages are produced by a discrete amount of energy being dumped into a power system, low impedance, heavy industrial systems can be expected to experience lower peaks from surge voltages than 120V residential systems, but comparable, or greater, amounts of energy potentially available for deposition in a surge suppressor. Rate of Occurrence and Voltage Levels In Unprotected Circuits The rate of occurrence of surges varies over wide limits, depending on the particular power system. Prediction of the rate for a particular system is always difficult and frequently impossible. Rate is related to the level of the surges; low- level surges are more prevalent than high-level surges. It is essential to recognize that a surge voltage observed in a power system can be either the driving voltage or the volt- age limited by the sparkover of some clearance in the sys- tem. Hence, the term unprotected circuit must be understood to be a circuit in which no low-voltage protective device has been installed but in which clearance sparkover will eventually limit the maximum voltage. The distribution of surge levels, therefore, is influenced by the surge-producing mechanisms as well as by the sparkover level or clearances in the system. This distinction between actual driving voltage and voltage limited by sparkover is particularly important at the interface between outdoor equipment and indoor equip- ment. Outdoor equipment has generally higher clearances, hence higher sparkover levels: 10kV may be typical, but 20kV is possible. In contrast, most indoor wiring devices used in 120V-240V systems have sparkover levels of about 6kV; this 6kV level, therefore, can be selected as a typical cutoff for the occurrence of surges in indoor power systems. = < 10' 2 o (3 u 2°io- 1 io- J I HIGH t*nj sunt \ V^MEDIl V~EXPO SURE >, CL SPAR* EARANC X .OVER OF ES (NOTE) LOW >S EXPOSURE I \ 0.3 0.5 2 5 SURGE CREST (kV) 10 20 NOTE: In some locations, sparkover of clearances may limit the overvoltages. FIGURE 1. RATE OF SURGE OCCURRENCE vs VOLTAGE LEVEL AT UNPROTECTED LOCATIONS Data collected from many sources have led to the plot shown in Figure 1. This prediction shows with certainty only a relative frequency of occurrence, while the absolute num- Z I o < b cc < LU E ^ cc uj o O LL t Condensed from a paper presented at the 1979 IEEE 14th Electrical/Electronics insulation Conference, Boston, October 9-1, 1979. Reprinted with permission of the Institute of Electrical and Electronics Engineers, tt ANSI/1 EEE C62.4I-I980 Guide on Surge Voltages in Low- Voltage AC Power Circuits. 1-19 The Development of a Guide on Surge Voltages in Low-Voltage AC Power Circuits ber of occurrences can be described only in terms of "low exposure," "medium exposure, or "high exposure." These exposure levels can be defined in general terms as follows: Low Exposure - Systems in geographical areas known for low lightning activity, with little load switching activity Medium Exposure - Systems in geographical areas known for high lightning activity, with frequent and severe switching transients. High Exposure - Rare but real systems supplied by long overhead lines and subject to reflections at line ends, where the characteristics of the installation produce high sparkover levels of the clearances. The two lower lines of Figure 1 have been drawn at the same slope, since the data base shows reasonable agree- ment among several sources on that slope. All lines may be truncated by sparkover of the clearances at levels depend- ing on the withstand voltage of these clearances. The "high- exposure" line needs to be recognized, but it should not be applied indiscriminately to all systems. Such application would penalize the majority of installations, where the expo- sure is lower. From the relative values of Figure 1 , two typical levels can be cited for practical applications. First, the expectation 3kV transient occurrence on a 120V circuit ranges from 0.01 to 10 per year at a given location a number sufficiently high to justify the recommendation of a minimum 3kV withstand capability. Second, the sparkover of wiring devices indicates that a 6kV withstand capability may be sufficient to ensure device survival indoors, but a withstand capability of 10kV, or greater, may be required outdoors. The voltage and current amplitudes presented in the Guide attempt to provide for the vast majority of lightning strikes but should not be considered as "worst case," since this con- cept cannot be determined realistically. One should think in terms of the statistical distribution of strikes, accepting a rea- sonable upper limit for most cases. Where the conse- quences of a failure are not catastrophic but merely represent an annoying economic loss, it is appropriate to make a trade-off of the cost of protection against the likeli- hood of failure caused by a high but rare surge. For instance, a manufacturer may be concerned with nationwide failure rates, those at the upper limits of the distribution curve, while the user of a specific system may be concerned with a single failure occurring at a specific location under "worst-case conditions." Rates can be estimated for average systems, however, and even if imprecise, they provide man- ufacturers and users with guidance. Of equal importance is the observation that surges in the range of 1 kV to 2kV are fairly common in residential circuits. Surges occur at random times with respect to the power fre- quency, and the failure mode of equipment may be affected by the power frequency follow current. Furthermore, the tim- ing of the surge with respect to the power frequency may affect the level at which failure occurs. Consequently, when the failure mode is likely to be affected, surge testing should be done with the line voltage applied to the test piece. Waveshape of Representative Surge Voltages Waveshapes in Actual Occurrences Indoor - Measurements in the field, measurements in the laboratory, and theoretical calculations indicate that most surge voltages in indoor low-voltage systems have oscilla- tory waveshapes, unlike the well-known and generally accepted unidirectional waves specified in high-voltage insu- lation standards. A surge impinging on the system excites the natural resonant frequencies of the conductor system. As a result, not only are the surges typically oscillatory, but surges may have different amplitudes and waveshapes at different places in the system. These oscillatory frequencies of surges range from 5kHz to more than 500kHz. A 30kHz to 100kHz frequency is a realistic measure of a "typical" surge for most residential and light industrial AC line networks. Outdoor and Service Entrance - Surges encountered in outdoor locations have also been recorded, some oscillatory, other unidirectional. The "classical lightning surge" has been established as 1 .2/50ms for a voltage wave and 8/20ms for a current wave, but these waveshapes should not be construed as typical waves for low-voltage circuits. Lightning discharges induce oscillations, reflections, and disturbances that ulti- mately appear as decaying oscillations in low-voltage systems. Because the prime concern here is the energy associated with these surges, the waveshape to be selected must involve greater energy than that associated with the indoor environment. Secondary surge arresters have a long history of successful performance, meeting the ANSI C62.1 specifi- cation, as detailed below; consequently, these specifications can be adopted as a realistic representation of outdoor waveshapes. Selection of Representative Waveshapes The definition of a waveshape to be used as representative of the environment is important for the design of candidate protective devices, since unrealistic requirements, such as excessive duration of the voltage or very low source imped- ance, place a high energy requirement on the suppressor, with a resulting cost penalty to the end user. The two requirements defined below reflect this trade-off. Indoor - Based on measurements conducted by several independent organizations in 120V and 240V systems, the wave- shape shown in Figure 2 is reasonably representative of surge voltages in these power circuits. Under the pro- posed description of a "0.5us - 100kHz ring wave," this waveshape rises in 0.5ns, then decays while oscillating at 100kHz, each peak being about 60% of the preceding peak. Outdoor - In the outdoor and service entrance environment, as well as in locations close to the service entrance, sub- stantial energy, or current, is still available, in contrast to the indoor environment, where attenuation has taken place. For these locations, the unidirectional impulses long established for secondary arresters are more appropriate than the oscil- latory wave. 1-20 The Development of a Guide on Surge Voltages in Low-Voltage AC Power Circuits Accordingly, the recommended waveshape is 1.2/50us for the open-circuit voltage or voltage applied to a high-imped- ance device, and 8/20us for the discharge current or current in a low-impedance device. The numbers used to describe the impulse, 1.2/50 and 8/20, are those defined in IEEE Standard 28 - ANSI Standard C62.1; Figure 3 presents the waveshape and a graphic description of the numbers. 09V PEAK . 0.5ns — »-l L<— 60% OFV PEAK FIGURE 2. THE PROPOSED 0.5ns - 100kHz RING WAVE (OPEN-CIRCUIT VOLTAGE) Energy and Source Impedance General The energy involved in the interaction of a power system with a surge source and a surge suppressor will divide between the source and the suppressor in accordance with the characteristics of the two impedances. In a gap-type suppressor, the low impedance of the arc after sparkover forces most of the energy to be dissipated elsewhere: for instance, in a resistor added in series with the gap for limit- ing the power-follow current. In an energy-absorber suppres- sor, by its very nature, a substantial share of the surge energy is dissipated in the suppressor, but its clamping action does not involve the power-follow energy resulting from the short-circuit action of a gap. It is therefore essential to the effective use of suppression devices that a realistic assumption be made about the source impedance of the surge whose effects are to be duplicated. The voltage wave shown in Figure 2 is intended to represent the waveshape a surge source would produce across an open circuit. The waveshape will be different when the source is connected to a load having a lower impedance, and the degree to which it is lower is a function of the imped- ance of the source. To prevent misunderstanding, a distinction between source impedance and surge impedance needs to be made. Surge impedance, also called characteristic impedance, is a con- cept relating the parameters of a line to the propagation of traveling waves. For the wiring practices of the AC power cir- cuits discussed here, this characteristic impedance would be in the range of 1 50£J to 300Q, but because the durations of the waves being discussed (50us to 2us) are much longer than the travel times in the wiring systems being considered, traveling wave analyses are not useful here. Source impedance, defined as "the impedance presented by a source energy to the input terminals of a device, or net- work" (IEEE Standard 100), is a more useful concept here. In the conventional Thevenin's description, the open-circuit voltage (at the terminals of the network or test generator) and the source impedance (of the surge source or test gen- erator) are sufficient to calculate the short-circuit current, as well as any current for a specified suppressor impedance. The measurements from which Figure 1 was derived were of voltage only. Little was known about the impedance of the circuits upon which the measurements were made. Since then, measurements have been reported on the impedance of power systems. Attempts were made to combine the observed 6kV open-circuit voltage with the assumption of a parallel 50n/50uH impedance. 0.9V P V W Vpeak o.sv PEAK — T, —J 50 M s T,x 1.67 = 1.2ns FIGURE 3A. OPEN-CIRCUIT VOLTAGE WAVEFORM 0.9I PI 0-1 "peak T 2 I 1.25 = 8ms FIGURE 3B. DISCHARGE CURRENT WAVEFORM FIGURE 3. UNIDIRECTIONAL (ANSI STANDARD C62.1) WAVESHAPES This combination resulted in low energy deposition capabil- ity, which was contradicted by field experience of suppressor performance. The problem led to the proposed definition of oscillatory waves as well as high-energy unidirectional waves, in order to produce both the effects of an oscillatory wave and the high-energy deposition capability. The degree to which source impedance is important depends largely on the type of surge suppressors that are used. The surge suppressors must be able to withstand the current passed through them by the surge source. A test generator of too high an impedance may not subject the device under test to sufficient stresses, while a generator of too low an imped- ance may subject protective devices to unrealistically severe stresses. A test voltage wave specified without reference to source impedance could imply zero source impedance one capable of producing that voltage across any impedance, even a short circuit. That would imply an infinite surge cur- rent, clearly an unrealistic situation. 1-21 The Development of a Guide on Surge Voltages in Low-Voltage AC Power Circuits Because of the wide range of possible source impedances and the difficulty of selecting a specific value, three broad categories of building locations are proposed to represent the vast majority of locations, from those near the service entrance to those remote from it. The source impedance of the surge increases from the outside to locations well within the building. Open-circuit voltages, on the other hand, show little variation within a building because the wiring provides little attenuation. Figure 4 illustrates the application of the three categories to the wiring of a building. For the two most common location categories, Table 1 shows the representative surge voltages and currents, with the waveforms and amplitudes of the surges, and high- or low-impedance specimen. For the discharge current shown, the last two columns show the energy that would be depos- ited in a suppressor clamping at 500V and 1 000V, typical of 120V or 240V applications, respectively. For higher system voltages (assuming the same current values), the energy would increase in proportion to the clamping voltage of a suppressor suitable for that system voltage. The values shown in Table 1 represent the maximum range and correspond to the "medium exposure" situation of Figure 1. For less exposed systems, or when the prospect of a failure is not highly objectionable, one could specify lower values of open-circuit voltages with corresponding reduc- tions in the discharge currents. The 6kV open-circuit voltage derives from two facts: the limit- ing action of wiring device sparkover and the unattenuated propagation of voltages in unloaded systems. The 3kA dis- charge current in Category B derives from experimental results: field experience in suppressor performance and simu- lated lightning tests. The two levels of discharge currents from the 0.5ns - 100kHz wave derive from the increasing imped- ance expected in moving from Category B to Category A. Location Category C is likely to be exposed to substantially higher voltages than location Category B because the limit- ing effect of sparkover is not available. The "medium expo- sure" rates of Figure 1 could apply, with voltage in excess of 10kV and discharge currents of 10kA, or more. Installing unprotected load equipment in location Category C is not recommended; the installation of secondary arresters, how- ever, can provide the necessary protection. Secondary arresters having 10kA ratings have been applied success- fully for many years in location Category C (ANSI Standards C62.1 and C62.2). NOTES: A Outlets and Long Branch Circuits: All outlets at more than 10m (30 feet) from Category B with wires #1 4-1 0; All outlets at more than 20m (60 feet) from Category C with wires #14-10. B. Major Feeders and Short Branch Circuits: Distribution panel devices; Bus and feeder systems in industrial plants; Heavy ap- pliance outlets with "short" connections to the service entrance; Lighting systems in commercial. C. Outside and Service Entrance: Sen/ice drop from pole to build- ing entrance; Run between meter and distribution panel; Over- head line to detached buildings; Underground lines to well pumps. FIGURE 4. LOCATION CATEGORIES TABLE 1 . SURGE VOLTAGES AND CURRENT DEEMED TO REPRESENT THE INDOOR ENVIRONMENT AND SUGGESTED FOR CONSIDERATION IN DESIGNING PROTECTIVE SYSTEMS LOCATION CATEGORY COMPARABLE TO IEC 664 CATEGORY IMPULSE TYPE OF SPECIMEN OR LOAD CIRCUIT ENERGY (JOULES) DEPOSITED IN A SUPPRESSOR (NOTE 3) WITH CLAMPING VOLTAGE OF WAVEFORM MEDIUM EXPOSURE AMPLITUDE 500V (120V SYSTEM) 1000V (240V SYSTEM) A. Long branch circuits and outlets II 0.5ms- 100kHz 6kV High Impedance (Note 1) 200A Low Impedance (Note 2) 0.8 1.6 B. Major feeders short branch circuits, and load center III 1.2/50ns 6kV High Impedance (Note 1 ) 8/20us 3kA Low Impedance (Note 2) 40 80 0.5ms -100kHz 6kV Low Impedance (Note 1 ) 500A High Impedance (Note 2) 2 4 NOTES: 1 . For high-impedance test specimens or load circuits, the voltage shown represents the surge voltage. In making simulation tests, use that value for the open-circuit voltage of the test generator. 2. For low-impedance test specimens or load circuits, the current shown represents the discharge current of the surge (not the short-circuit current of the power system). In making simulation tests, use that current for the short-circuit current of the test generator. 3. Other suppressors which have different clamping voltages would receive different energy levels. 1-22 TVS TRANSIENT SUPPRESSION DEVICES AND PRINCIPLES PAGE TRANSIENT SUPPRESSION DEVICES AND PRINCIPLES 2-3 Transient Suppression Devices 2-3 A Simplified Comparison Between Protection with Linear and Nonlinear Suppressor Devices 2-4 Transient Suppressors Compared 2-6 Comparison of Zener Diode and Harris Varistor Transient Suppressors 2-8 Proof Tests 2-10 Update On New Devices 2-10 < _i ^2 2-1 Transient Suppression Devices and Principles This section presents a brief description of available tran- sient suppressors and their operation, and discusses how these devices can be applied. Transient Suppression Devices There are two major categories of transient suppressors: a) those that attenuate transients, thus preventing their propa- gation into the sensitive circuit; and b) those that divert tran- sients away from sensitive loads and so limit the residual voltages. Attenuating a transient, that is, keeping it from propagating away from its source or keeping it from impinging on a sensi- tive load is accomplished with filters inserted in series within a circuit. The filter, generally of the low-pass type, attenuates the transient (high frequency) and allows the signal or power flow (low-frequency) to continue undisturbed. Diverting a transient can be accomplished with a voltage- clamping type device or with a "crowbar" type device. The designs of these two types, as well as their operation and application, are different enough to warrant a brief discus- sion of each in general terms. A more detailed description will follow later in this section. A voltage-clamping device is a component having a variable impedance depending on the current flowing through the device or on the voltage across its terminal. These devices exhibit a nonlinear impedance characteristic that is, ohm's law is applicable but the equation has a variable R. The vari- ation of the impedance is monotonic; in other words, it does not contain discontinuities in contrast to the crowbar device, which exhibits a turn-on action. The volt-ampere characteris- tic of these clamping devices is somewhat time-dependent, but they do not involve a time delay as do the sparkover of a gap or the triggering of a thyristor. 1 0.01 t ^Z = 1 >n V 1 10 CURRENT (A) NON-LINEAR IMPEDANCE (POWER LAW): I = KV° FIGURE 1. VOLTAGE/CURRENT CHARACTERISTIC FOR A LINEAR m RESISTOR AND NONLINEAR VARISTOR With a voltage-clamping device, the circuit is unaffected by the presence of the device before and after the transient for any steady-state voltage below the clamping level. The volt- age clamping action results from the increased current drawn through the device as the voltage tends to rise. If this current increase is greater than the voltage rise, the imped- ance of the device is nonlinear (Figure 1). The apparent "clamping" of the voltage results from the increased voltage drop (IR) in the source impedance due to the increased cur- rent. It should be clearly understood that the device depends on the source impedance to produce the clamping. One is seeing a voltage divider action at work, where the ratio of the divider is not constant but changes. However, if the source impedance is very low, then the ratio is low. The suppressor cannot be effective with zero source impedance (Figure 2) and works best when the voltage divider action can be implemented. Vzv,(_fY_)V c FIGURE 2A. VOLTAGE CLAMPING DEVICE FIGURE 2B. CROWBAR DEVICE FIGURE 2. DIVISION OF VOLTAGE WITH VARIABLE IMPED- ANCE SUPPRESSOR Crowbar-type devices involve a switching action, either the breakdown of a gas between electrodes or the turn-on of a thyristor. After switching on, they offer a very low impedance path which diverts the transient away from the parallel-con- nected load. These crowbar devices have two limitations. The first is their delay time, typically microseconds, which leaves the load unprotected during the initial rise. The second limitation is that a power current from the steady-state voltage source will follow the surge discharge (called "follow-current" or "power-follow"). In AC circuits, this power-follow current may or may not be cleared at a natural current zero; in DC cir- cuits the clearing is even more uncertain. Therefore, if the crowbar device is not designed to provide self-clearing action within specified limits of surge energy and system voltage and power-follow current, additional means must be provided to open the power circuit. ! 2-3 Transient Suppression Devices and Principles Filters The frequency components of a transient are several orders of magnitude above the power frequency of an AC circuit and, of course, a DC circuit. Therefore, an obvious solution is to install a low-pass filter between the source of transients and the sensitive load. The simplest form of filter is a capacitor placed across the line. The impedance of the capacitor forms a voltage divider with the source impedance, resulting in attenuation of the transient at high frequencies. This simple approach may have undesirable side effects, such as a) unwanted reso- nances with inductive components located elsewhere in the circuit leading to high peak voltages; b) high inrush currents during switching, or, c) excessive reactive load on the power system voltage. These undesirable effects can be reduced by adding a series resistor hence, the very popular use of RC snubbers and suppression networks. However, the price of the added resistance is less effective clamping. Beyond the simple RC network, conventional filters compris- ing inductances and capacitors are widely used for interfer- ence protection. As a bonus, they also offer an effective transient protection, provided that the filter's front-end com- ponents can withstand the high voltage associated with the transient. There is a fundamental limitation in the use of capacitors and filters for transient protection when the source of transients in unknown. The capacitor response is indeed nonlinear with frequency, but it is still a linear function of current. In Section 1, it was explained that to design a protection scheme against random transients, it is often necessary to make an assumption about the characteristics of the imping- ing transient. If an error in the source impedance or in the open-circuit voltage is made in that assumption, the conse- quences for a linear suppressor and a nonlinear suppressor are dramatically different as demonstrated by the following comparison. A Simplified Comparison Between Protection with Linear and Nonlinear Suppressor Devices Assume an open-circuit voltage of 3000V (see Figure 2): 1 . If the source impedance is Z = 50Q With a suppressor impedance of Z v = 81i The expected current is: 1 = = 51 .7A and V R = 8x51.7 = 414V The maximum voltage appearing across the terminals of a typical nonlinear V130LA20A varistor at 51. 7A is 330V. Note that: Z s xl = 50X51.7=2586V Z v xl = 8X51.7 = 414V = 3000V 2. If the source impedance is only 5S1 (a 1 0: 1 error in the as- sumption), the voltage across the same linear 8£2 sup- pressor is: V R = 3000 = 1850V However, the nonlinear varistor has a much lower imped- ance; again, by iteration from the characteristic curve, try 400V at 500A, which is correct for the V130LA20A; to prove the correctness of our "educated guess" we calculate I, 3000-400V Z s X I = 5 x 520 = 2600V l= I =520A Vc= 400V = 3000V which justifies the "educated guess" of 500A in the circuit. NOTE: An educated guess, or the result of an iteration, see "Design- ing with Harris Varistors," Section 6. Summary TABLE 1. 3000V "OPEN-CIRCUIT" TRANSIENT VOLTAGE PROTECTIVE DEVICE ASSUMED SOURCE IMPEDANCE SOU 5Q PROTECTIVE LEVEL ACHIEVED Linear 8il 414V 1850V Nonlinear Varistor 330V 400V Similar calculations can be made, with similar conclusions, for an assumed error in open-circuit voltage at a fixed source impedance. In that case, the linear device is even more sen- sitive to an error in the assumption. The calculations are left for the interested reader to work out. The example calculated in the simplified comparison between protection with linear and nonlinear suppression devices shows that a source impedance change from an assumed 50Q to 5iJ can produce a change of about 414V to 1850V for the protective voltage of a typical linear suppres- sor. With a typical nonlinear suppressor, the corresponding change is only 330V to 400V. In other words, a variation of only 21% in the protective level achieved with a nonlinear suppressor occurs for a 10 to 1 error in the assumption made on the transient parameters, in contrast to a 447% variation in the protective level with a linear suppressor for the same error in assumption. Nonlinear voltage-clamping devices give the lowest clamping voltage, resulting in the best protection against transients. Crowbar Devices This category of suppressors, primarily gas tubes (also called "spark gaps") or carbon-block protectors, is widely used in the communication field where power-follow current is less of a problem than in power circuits. Another form of these suppressors is the hybrid circuit which uses solid-state or ionic devices where a control circuit causes turn-on of an active component. 2-4 Transient Suppression Devices and Principles In effect, a crowbar device short-circuits a high voltage to ground. This short will continue until the current is brought to a low level. A voltage clamping device will never reduce the line voltage below its steady-state value but the crowbar device often will. Because the voltage (arc or forward-drop) during the discharge is held very low, substantial currents can be carried by the suppressor without dissipating a con- siderable amount of energy within the suppressor. This capability is the major advantage of these suppressors. However, two limitations must be considered. Volt-Time Response - When the voltage rises across a spark gap, no significant conduction can take place until transition to the arc mode has occurred by avalanche break- down of the gas between the electrodes. The delay time, typically microseconds, leaves the load unprotected during the initial rise. Since the process is statistical in nature, there is a considerable variation in the sparkover voltage obtained in successive operations. For some devices, this sparkover voltage also can be substantially higher after a long period of rest than after a succession of discharges. From the physical nature of the process, it is difficult to produce consistent sparkover voltage for low voltage ratings. The difficulty is compounded by the effect of manufacturing tolerances on very small gap distances. One way to alleviate the difficulty is to fill the tube with a gas having a lower breakdown voltage than that of air. However, this substitution creates a reliability problem if the enclosure seal is lost and the gas is replaced by air. Some applications require providing a second gap in parallel with the first, with slightly higher sparkover voltage for backup against failure of the gas tube. Power-Follow - The second limitation is that a power cur- rent from the steady-state voltage source will follow the surge discharge (called lollow-current" or "power-follow"). In AC circuits, this power-follow current may or may not be cleared at a natural current zero; in DC circuits the clearing is even more uncertain. Therefore, if the crowbar device is not designed to provide self-clearing action within specified limits of surge energy and system voltage and power-follow current, additional means must be provided to open the power circuit. Voltage-Clamping Devices To perform the voltage limiting function, voltage-clamping devices at the beginning of the section depend on their nonlinear impedance in conjunction with the transient source impedance. Three types of devices have been used: reverse selenium rectifiers, avalanche (zener) diodes and varistors made of different materials, i.e., silicon carbide, zinc oxide, etc.! 1 ! Selenium Cells - Selenium transient suppressors apply the technology of selenium rectifiers in conjunction with a special process allowing reverse breakdown current at high-energy levels without damage to the polycrystalline structure. These cells are built by developing the rectifier elements on the surface of a metal plate substrate which gives them good thermal mass and energy dissipation per- formance. Some of these have self-healing characteristics which allows the device to survive energy discharges in excess of the rated values for a limited number of operations characteristics that are useful, if not "legal" in the unsure world of voltage transients. The selenium cells, however, do not have the clamping abil- ity of the more modern metal-oxide varistors or avalanche diodes. Consequently, their field of application has been considerably diminished. Zener Diodes - Silicon rectifier technology has improved the performance of regulator-type zener diodes in the direction of the design of surge-suppression type avalanche diodes. The major advantage of these diodes is their very effective clamping, which comes closest to an ideal constant voltage clamp. They are also available in low-voltage ratings. Since the diode maintains the avalanche voltage across a thin junction area during surge discharge, substantial heat is generated in a small volume. The major limitation of this type of device is its energy dissipation capability. Varistors - A varistor functions as a nonlinear variable impedance. The relationship between the current in the device, I, and the voltage across the terminals, V is typically described by a power law: I = kV". While more accurate and more complete equations can be derived to reflect the phys- ics of the device, [2 ' 3 ' this definition will suffice here. A more detailed discussion will be found in Section 3. The term a (alpha) in the equation represents the degree of nonlinearity of the conduction. A linear resistance has an a = 1 . The higher the value of a, the better the clamp, which explains why a is sometimes used as a figure of merit. Quite naturally, varistor manufacturers are constantly striving for higher alphas. Silicon Carbide Varistors - Until the introduction of metal- oxide varistors, the most common type of varistor was made from specially processed silicon carbide. This material was very successfully applied in high-power, high-voltage surge arresters. However, the relatively low a values of this mate- rial produce one of two results. Either the protective level is too high for a device capable of withstanding line voltage or, for a device producing an acceptable protective level, exces- sive standby current would be drawn at normal voltage if directly connected across the line. Therefore, a series gap is required to block the normal voltage. A detailed discussion of series gap/silicon carbide block combinations is beyond the scope of this manual, but many references and standards on the design, testing and applica- tion of surge arrestors are available. I 4 ' 5 l In lower voltage electronic circuits, silicon carbide varistors have not been widely used because of the need for using a series gap, which increases the total cost and reproduces some of the undesirable characteristics of gaps described earlier. However, this varistor has been used as a current-limiting resistor to assist some gaps in clearing power-follow current. Id) in o. go 2-5 Transient Suppression Devices and Principles Metal-Oxide Varistors - This family of transient voltage suppressors are made of sintered metal oxides, primarily zinc oxide with suitable additives. These varistors have a values considerably greater than those of silicon carbide varistors, typically in the range of an effective value of 15 to 30 measured over several decades of surge current. One type of varistor, the Harris Varistor, will be described in greater detail in Section 3. For the moment, the description will be limited to what is necessary for understanding the dis- cussion of suppression and application in this section. The high exponent values (a) of the metal-oxide varistors have opened completely new fields of applications by pro- viding a sufficiently low protective level and a low standby current. The opportunities for applications extend from low- power electronics to the largest utility-type surge arresters. Transient Suppressors Compared Because of diversity of characteristics and nonstandardized manufacturer specifications, transient suppressors are not easy to compare. A graph (Figure 3) shows the relative volt- ampere characteristics of the four common devices that are used in 120V AC circuits. A curve for a simple ohmic resistor is included for comparison. It can be seen that as the alpha factor increases, the curve's voltage-current slope becomes less steep and approaches an almost constant voltage. High alphas are desirable for clamping applications that require operation over a wide range of currents. It also is necessary to know the device energy-absorption and peak-current capabilities when comparisons are made. Table 2 includes other important parameters of commonly used suppressors. INSTANTANEOUS CURRENT (A) FIGURE 3. V-l CHARACTERISTIC OF FOUR TRANSIENT SUP- PRESSOR DEVICES Standby Power - The power consumed by the suppressor unit at normal line voltage is an important selection criterion. Peak standby current is one factor that determines the standby power of a suppressor. The standby power dissipa- tion depends also on the alpha characteristic of the device. As an example, a selenium suppressor in Table 2 can have a 12mA peak standby current and an alpha of 8 (Figure 3). Therefore, it has a standby power dissipation of about 0.5W on a 120V RMS line (170V peak). A zener-diode suppressor has standby power dissipation of less than a milliwatt. And a silicon-carbide varistor, in a 0.75" diameter disc, has standby power in the 200mW range. High standby power in the lower alpha devices is necessary to achieve a reasonable clamp- ing voltage at higher currents. S 0.1 I 1 1 1 1 1 1 96 98 100 102 104 106 108 110 PERCENT OF RATED VOLTAGE FIGURE 4. CHANGES IN STANDBY POWER ARE CONSIDER- ABLY GREATER WHEN THE SUPPRESSOR'S ALPHA IS HIGH The amount of standby power that a circuit can tolerate may be the deciding factor in the choice of a suppressor. Though high-alpha devices have low standby power at the nominal design voltage, a small line-voltage rise would cause a dra- matic increase in the standby power. Figure 4 shows that for a zener-diode suppressor, a 10% increase above rated volt- age increases the standby power dissipation above its rating by a factor of 30. But for a low-alpha device, such as silicon carbide, the standby power increases by only 1 .5 times. Typical volt-time curves of a gas discharge device are shown in Figure 5 indicating an initial high clamping voltage. The gas-discharge suppressor does not turn on unless the tran- sient pulse exceeds the impulse sparkover voltage. Two rep- resentative surge rates 1kV/us and 20kV/us are shown in Figure 5. When a surge voltage is applied, the device turns on at some point within the indicated limits. At 20kV/us, the discharge unit will sparkover between 600V and 2500V. At 1kV/us, it will sparkover between 390V and 1500V. In use for the protection of AC line surges, the gas discharge device may experience follow-current. As the voltage passes through zero at the end of every half cycle the arc will extin- guish, but if the electrodes are hot and the gas is ionized, it may reignite on the next cycle. Depending on the power source, this current may be sufficient to cause damage to the electrodes. The follow current can be reduced by placing a limiting resistor in series with the device, reducing its cur- rent, but at a penalty of increased clamping voltage. The gas discharge device is useful for high current surges but it is not effective in protecting low voltage, low imped- ance circuits. It is often advantageous to provide another 2-6 Transient Suppression Devices and Principles TABLE 2. CHARACTERISTICS AND FEATURES OF TRANSIENT VOLTAGE SUPPRESSOR TECHNOLOGY V-l CHARACTERISTICS DEVICE TYPE LEAK- AGE FOLLOW ON 1 CLAMPING VOLTAGE ENERGY CAPA- BILITY CAPACI- TANCE RE- SPONSE TIME COST V - CLAMPING VOLTAGE WORKING VOLTAGE TRANSIENT CURRENT ' Ideal Device Zero To Low No Low High Low Or High Fast Low V ♦ .' T~ VOLTAGE * 1 Zinc Oxide Varistor Low No ModerateT Low High Moderate To High Fast Low V MAX 1 LIMIT f 1 .WORKING 1 ' VOLTAGE ' ► 1 Zener Low No Low Low Low Fast High V PEAK VOLTAGE (IGNITION) k WORKING 'l Crowbar (Zener- SCR Combination) Low Yes (Latching Holding 1) Low Medium Low Fast Moderate V PEAK VOLTAGE (IGNITION) h WORKING n VOLTAGE Spark Gap Zero Yes High Ignition Voltage Low Clamp High Low Slow Low To High V PEAK VOLTAGE (IGNITION) . _ J WORKING Triggered Spark Gap Zero Yes Lower Ignition Voltage Low Clamp High Low Moderate High V , f VOLTAGE ' 1 Selenium Very High No Moderate To High Moderate To High High Fast High V WORKING " " VOLTAGE Silicon Carbide Varistor High No High High High Fast Relative Low 2-7 Transient Suppression Devices and Principles suppression device in a combination that allows the added suppressor to protect against the high initial impulse. Sev- eral hybrid combinations with a varistor or avalanche diode are possible. Care in design is required to direct the initial portion of the impulse to the solid state device and to divert the high current of the later portion of the pulse to the gas discharge element. Precautions must also be taken against voltages induced in adjacent wiring by the sharp current rise associated with the gap sparkover. 6000 5000 4000 3000 1000 800 600 500 400 300 300 200 10- 1 i J/ */ 9.5mm OD, 230V J GAS-DISCHARGE SUPPRESSOR 10"* 10 -7 10- 6 10" 5 10"* SHORT-TIME SURGE RESPONSE (S) FIGURE 5. IMPULSE BREAKOVER OF A GAS-DISCHARGE DEVICE DEPENDS UPON THE RATE OF VOLTAGE RISE AS WELL AS THE ABSOLUTE VOLTAGE LEVEL Comparison ofZener Diode and Harris Varistor Transient Suppressors Many circuit designers ask, "Which device is better, a zener or varistor?" Unfortunately, there is no simple answer. To make this point clear, different features will be covered to aid in realizing the proper choice among the two device types. Peak Pulse Power Transient suppressors have to be optimized to absorb large amounts of power or energy in a short time duration: nano- seconds, microseconds, or milliseconds in some rare instances. Electrical energy is transformed into heat and has to be dis- tributed instantaneously throughout the device. Transient thermal impedance is much more important than steady state thermal impedance, as it keeps peak junction tempera- ture to a minimum. In other words, heat should be instantly and evenly distributed throughout the device. The varistor meets these requirements: an extremely reli- able device with large overload capability. Zener diodes on the other hand, transform electrical energy into heat in the depletion region, an extremely small area, resulting in high peak temperature. From there the heat will flow through the silicon and solder joint to the copper. Thermal coefficient mismatch and large temperature differentials can result in an unreliable device for transient suppression. Figure 6 shows Peak Pulse Power vs Pulse width for the V8ZA2 and the P6KE 6.8, the same devices compared for leakage current. 10ms 20 PULSE TIME 100ms 1000ms FIGURE 6. PEAK PULSE POWER vs PULSE TIME At 1ms, the two devices are almost the same. At 2us the varistor is almost 10 times better, 7kW for the P6KE 6.8 Zener vs 60kW for the varistor V8ZA2. Clamping Voltage Clamping voltage is an important feature of a transient sup- pressor. Zener diode type devices have lower clamping volt- ages than varistors. Because all protective devices are connected in parallel with the device or system to be pro- tected, a lower clamping voltage will apply less stress to the device protected. CURRENT FIGURE 7. CHARACTERISTICS OF ZENER AND VARISTOR Speed of Response Response times of less than 1pS are claimed for zener diodes, but these claims are not supported by any data or measurements. For the varistor, measurements were made down to 500pS with a voltage rise time (dv/dt) of 1 million volts per microsecond. These measurements are described in Speed of Response and Rate Effects, Section 3 of this data book. Another consideration is the lead effect. Detailed infor- mation on the lead effect can be found further in this section and in Section 7. In summary, both devices are fast enough to respond to any practical requirements, including N-EMP type transients. Leakage Currents Leakage current and sharpness of the knee are two other areas of misconception about the varistor and zener diode devices. Figure 8 shows a P6KE 6.8 and a V8ZA2, both rec- ommended by their manufacturers for protection of inte- grated circuits having 5V supply voltages. 2-8 Transient Suppression Devices and Principles The zener diode leakage is about 100 times higher at 5V than the varistor, 200uA vs less than 2)jA. 1 I I I I mniiA pfr vfrtip.ai niv 1V PER HORI ZON1 AL D V. )KE 6 3ZA2 P .8 V / FIGURE 8. CHARACTERISTIC OF ZENER P6KE 6.8 (ON LEFT) vs HARRIS VARISTOR V8ZA2 (ON RIGHT) For a leakage current comparison, 25 zener diode devices were measured at 25°C. Only 1 device measured 30uA. The rest were 150uA and more. At elevated temperatures, the comparison is even more favorable to the varistor. The zener diode is specified at 1000uA at 5.5V. The leakage current of a zener can be reduced by specifying a higher voltage device which would have a lower leakage current, but the price is a higher clamping voltage and the advantage of the zener disappears. "Aging- Aging is actually a misnomer; it has been stated that a varis- tor's V-l characteristic changes every time energy is absorbed. That is not the case! 8 x 20liS WAVE V31CP20 but rather, viewed in perspective of the definition of a failed device. A "failed" device shows a ±10% change of the V-l characteristic at the 1mA point. Zener diodes, on the other hand, fail suddenly at predictable power and energy levels. See Figure 6. This, along with its superior peak pulse power capability, makes the varistor the device of choice in many applications. Failure Mode Varistors subjected to energy levels beyond specified ratings may be damaged. Varistors fail in the short circuit mode. Subjected to high enough energy, however, they may physi- cally rupture or explode, resulting in an open circuit condi- tion. These types of failures are quite rare for properly selected devices because of the large peak pulse capabili- ties inherent in varistors. Zeners, on the other hand, can fail either short or open. If the die is connected by a wire, it can act as a fuse, disconnect- ing the device and resulting in an Open circuit. Designers must analyze which failure mode, open or short, is preferred for their circuits. When a device fails during a transient, a short is preferred, as it will provide a current path bypassing and will continue to protect the sensitive components. On the other hand, if a device fails open during a transient, the remaining energy ends up in the sensitive components that were supposed to be protected. If the energy was already dissipated, the circuit will now operate without a suppressor and the next transient, or the next few transients, will finish the job. These are just some of the points to be considered when comparing and using transient suppressors. Another consideration is a hybrid approach, making use of the best features of both types of transient suppressors (See Figure 10). VARISTOR INPUT n § CO 0- FIGURE 9. 250A PULSE WITHSTAND CAPABILITIES As illustrated in Figure 9, the V-l characteristic initially changed on some of the devices, but returned to within a few percent of its original value after applying a second or third pulse. To be conservative, peak pulse limits have been established on data sheets. In many cases, these limits have been exceeded many fold without harm to the device. This does not mean that established limits should be exceeded, FIGURE 10. HYBRID PROTECTION USING VARISTORS, ZENERS, R AND L Capacitance Depending on the application, transient suppressor capacitance can be a very desirable or undesirable feature. Varistors in comparison to zener diodes have a higher capacitance. In DC circuits capacitance is desirable, the larger the better. Decoupling capacitors are used on IC 2-9 Transient Suppression Devices and Principles supply voltage pins and can in many cases be replaced by varistors, providing both the decoupling and transient voltage clamping functions. The same is true for filter connectors where the varistor can perform the dual functions of providing both filtering and transient suppression. There are circuits however, where capacitance is less desir- able, such as high frequency digital or some analog circuits. As a rule the source impedance of the signal and the frequency as well as the capacitance of the transient suppressor should be considered. The current through C P is a function of dv/dt and the distortion is a function of the signal's source impedance. Each case must be evaluated individually to determine the maximum allowable capacitance. The structural characteristics of metal-oxide varistors unavoidably result in an appreciable capacitance between the device terminals, depending on area, thickness and material processing. For the majority of power applications, this capacitance is not significant. In high-frequency applica- tions, however, the effect must be taken into consideration in the overall system design. Proof Tests To consider protective devices while a system is being designed and to follow with proof tests should be axiomatic, but historical evidence makes it apparent that this is not so. Thus, retrofit of transient suppressors is common practice. Actually, one can view this retrofit as part of the trade-off pro- cess, with iterative corrections in a calculated risk approach. It may be justifiable to attempt applying some device with minimal protection in the harsh outside world, and later, when found necessary, to take corrective action. Hence, ret- rofit should then be the result of informed choice, not an unforeseen need for correction. Even here, some form of proof testing will be required to ascertain that the retrofit will do the job.! 9 ) The nature of the transient environment comes under exam- ination when a retrofit must be applied. There is some fac- tual knowledge on the subject, discussed in Section 1, but there are also many tentative "generalizations" that require confirmation. Test standards and specifications, then, become useful guides to the extent that they are not applied or enforced blindly.! 8 ' Some test specifications emphasize voltage tests. This is natural because historically, electrical equipment had dielectric failures as the major consequence of overvoltages. One can, therefore, specify some voltage test wave that the equipment must withstand without breakdown. However, with the inclusion of a protective device within the equipment, a simple voltage test is no longer meaningful. What is needed is the two-step approach discussed below, where the voltage allowed by the protector is determined first, then the effects on the downstream components determined. Coordination is the key concept. One point to remember when specifying or performing a test is the difference between a voltage and a current test. In testing a device for voltage withstand capability, proper recognition must be given to the impedance of the device being tested and to whether or not it already contains a tran- sient suppressor. First, one specifies the test circuit which will exercise the suppressor: open circuit voltage, (amplitude and duration) and source impedance. This determines the clamp voltage that will be developed across the shunt-con- nected suppressor (Figure 11). Second, one designs the protected circuit for this clamp voltage allowing adequate margins. After the design, this two-step approach can also be applied for demonstrating that withstand capability has been achieved. FIGURE 11. TWO STEPS FOR EVALUATING PROTECTION REQUIREMENTS Section 7 provides detailed information on varistor testing, both for evaluating varistor characteristics and for conduct- ing realistic proof tests. Update On New Devices • Radial Varistors • High Energy Varistors • Square Varistors • Connector Pin Varistors • Surface Mount CH Series • Surface Mount Multilayer Series • RA Series Low Profile Varistors The "C" III Series FIGURE 12. 2-10 Transient Suppression Devices and Principles The "C" ill Series (Figure 12) is an expanded version of the LA series of metal-oxide varistors, and consists of AC line voltage rated MOVs with extremely high current and energy handling capabilities. This new "C" III series of MOVs were primarily designed for the transient voltage surge suppressor (TVSS) environment. They provide the increased level of protection now deemed to be necessary for the transients expected in this environment. This new expanded version of the Harris 14mm and 20mm LA series of metal oxide varistors is also available with 10mm lead spacing, in tape and reel and in a variety of dis- tinctive crimped and trimmed offerings. The HA Series FIGURE 13. The HA Series (Figure 13) is an innovation in varistor pack- aging technology. This new format gives a very high energy/ current handling capability in a cost effective package. They are designed to provide secondary surge protection in the outdoor and service entrance environment (distribution panels), in computers, and also in industrial applications for motor controls and power supplies used in the oil-drilling, mining, and transportation fields. The HA series of industrial varistors have similar package construction but differ in size, (32 and 40mm), ratings and characteristics. The design of the HA series of metal oxide varistors provide rigid terminals to ensure secure mounting. See HA Series data sheet in Section 4 for specifications. The NA Series FIGURE 14. The NA Series (Figure 14) are industrial high energy square varistors intended for special applications requiring unique contact or packaging considerations. The electrode finish of these devices is solderable and can also be used as pressure contacts for stacking applications. The NA series industrial square varistor is available as a 34mm device, with thicknesses ranging from 1.8mm minimum for the 130V device to 8.3mm maximum for the 750V device. The Connector Pin Varistor for Transient Voltage Protec- tion in Connectors The Connector Pin Varistor represents an entirely new approach to transient suppression, forming the active mate- rial into a shape which requires no leads or package. The idea was developed many years ago, but only recently have breakthroughs in the manufacturing process allowed cost effective production of such devices. PASSIVATION ELECTRODES^^A. PASSIVATION CENTER METALLIZED ELECTRODE OUTSIDE METALLIZED ELECTRODE FIGURE 15. TUBULAR VARISTOR (CONNECTOR PIN VARIS- TOR) CP AND CS SERIES When assembled into a standard connector, adding no space or appreciable weight, they allow effective space sav- ing transient suppression. Connector Pin Varistors (CPV's) are available in a wide range of voltage ratings with mechan- ical dimensions allowing them to be used with 22, 20, or 16 gauge connector pins. The electrical characteristics are similar to those of tradi- tional varistors and are described in detail on the pulse rat- ing curves of the CP and CS series data sheets. Although electrically similar, there are some important differ- ences in performance between CPV's and leaded varistors such as speed of response. Tests made on lead mounted devices, even with careful attention to minimize lead length, show that the voltage induced through lead inductance contributes substantially to the voltage appearing across the varistor terminals. These undesirable induced voltages are proportional to lead induc- tance and di/dt and can be positive or negative. di dt XL V c = CLAMPING VOLTAGE FIGURE 16. SHOWS THE ELECTRICAL EQUIVALENT OF A LEAD MOUNTED VARISTOR 2-11 Transient Suppression Devices and Principles V12ZA1 I ■ 2.5A, 300V to = 4nsl\CURRENT WAVE FIGURE 17. EXPONENTIAL PULSE APPLIED TO A RADIAL DEVICE (5V/DIV., 50ns/DIV.) Pursuing the inductive lead effect further; calculation of the induced voltage as a direct result of lead effect for different current rise times provides a better understanding of the di/dt value at which the lead effects become significant. Assuming a current pulse of 10A, 1 inch of lead wire (which translates into approximately 15nH) and rise times ranging from microseconds to femtoseconds, Table 3 is obtained. e-v c di e=-jr«L V8CP22 I PEAK ■ 2-SA, 300V FIGURE 18. EXPONENTIAL PULSE APPLIED TO A PIN-VARIS- TOR (5V/DIV., 50ns/DIV.) Figure 17 shows the positive and negative part of the induced voltage, resulting from a pulse with a rise time of 4ns to a peak current of 2.5A. When the above measurement is repeated with a leadless varistor, such as the Connector Pin Varistor, its unique coax- ial mounting allows it to become part of the transmission line. This completely eliminates inductive lead effect. TABLE 3. INDUCED VOLTAGE IN 1 INCH LEADS. PEAK CUR- RENT 10A, AT DIFFERENT CURRENT RISE TIME RISE TIME I L e 1X10- 6 1|is 10A 15nH 150 x10 3 1x10" 9 1ns 10A 15nH 150 1x10" 12 1ps 10A 15nH 150x10 +3 1x10" 18 Its 10A 15nH 150 x10* 6 Figure 19 illustrates the lead effect even more dramatically for fast rising pulses ranging in rise time from milliseconds to femtoseconds. MODEL 15,000,000V 10" 15 10" 10" 10-» 10" 7 10" s 10 3 FEMTO PICO NANO MICRO MILLI TIME IN SEC FIGURE 19. LEAD EFFECT OF 1 INCH CONNECTION L= 15nH A short lead length is important when fast rising pulses (below 10ns) must be suppressed. This and other factors led Harris to the development of new varistor form factors like the Pin Varistor. Figure 20 shows the clamping voltage of a Pin Varistor installed in a connector. The result of a 1000V pulse, 10A amplitude, 100ns duration with 5ns rise time results in a clamping voltage of 29V. The 29V includes the overshoot, dropping at the end of the pulse to 22V, resulting in an aver- age clamping voltage of 25V. For more detailed information on the Connector Pin Varistor see the application note in Section 12. 2-12 Transient Suppression Devices and Principles NANOSECONDS DATA BASE -0.094 V PEAK 29.086 V AREA 3.29800E-06 VS E.P.W. 1.13400E-07 S 40 80 120 160 200 FIGURE 20A. NANOSECONDS 12A 10 DATA 8 BASE 0.1767 A PEAK 9.65 A 6 AREA 9.12700E-07 VS E.P.W. 9.45800E-08 S 4 f — - 120 160 200 FIGURE 20B. FIGURE 20. CLAMPING VOLTAGE ON CONNECTOR EQUIPPED WITH V8CP22 PIN VARISTORS (COURTESY OF BENDIX CONNECTOR OPERATION OF ALLIED, AMPHENOL PRODUCTS) Surface Mount Varistors FIGURE 21. CH SERIES Electronics manufacturers are turning to surface-mount technology to lower costs, increase reliability, and reduce the size and weight of their products. As a consequence, sys- tems designers are looking for surface-mount solutions to the problem of transient voltage protection. The increased circuit densities now possible with surface- mount systems have also increased the susceptibility of these tightly-clustered semiconductors to damage or upset by voltage transients. Thus, surface-mount technology demands a reliable transient voltage protection technology, packaged compatibly with other forms of surface-mount semiconductors. Harris has introduced a series of surface-mount varistors for a wide range of applications. These varistors have signifi- cantly lower profiles than traditional radial leaded varistors (Figure 22), and are compatible with most surface-mounting assembly equipment. LA SERIES 7mm RADIAL VARISTOR CH SERIES 5mm x 8mm k\\\\\\\l SURFACE MOUNT DEVICE IT CH Features • Available in Voltage Ratings 14VDC to 369VDC • 5mm x 8mm Size • U.L. Approved • 125°C Maximum Operating Temperature Multilayer Surface Mount Suppressors The ML Series of surge suppressors utilize Harris Multilayer technology. This fabrication technique permits significant energy handling capability in a very small footprint. Industry standard sizes of "0805", "1206", and "1210" are offered with working voltages of 3.5V to 68VDC. The ML series is ideally suited for on-board protection of transistors and integrated circuits from transient surges, including ESD. Larger surface mount zener diodes may also be replaced by this series. Additionally, the "0805" size is offered in two capacitance/energy versions, providing more options for the circuit designer. A special multilayer version, characterized for automotive applications, is available as the AUML Series in standard "1210", "1812", and "2220" sizes. The AUML series is rated up to 25 Joules for "load dump" transients per SAE specifi- cation J1113. And, like the ML Series, operates without der- ating from -55°C to+125°C. FIGURE 23. The RA Series Low Profile Varistor The RA Series (Figure 23) is an innovation in varistor pack- aging which has a lower profile than traditional radial varis- tors. Its precise seating plane increases mechanical stability for secure circuit board mounting a feature that makes the design well suited to high-vibration applications. Other applications of the RA Series varistor include automo- tive, motor control, test equipment, computer, consumer electronics, telecommunications, and military markets. RA Series varistors can be operated at +125°C, the result of advances in materials technology. They are available in volt- age and energy ratings up to 275V (RMS), 140J. Available on tape and reel for auto-insertion, they feature in-line leads for easier automatic placement. See RA Series data sheet for specifications. 2-13 Concept in Station Arrester Design," IEEE Trans. PAS- 96, No. 2, March-April 1977, pp. 647-656. [2] Philipp, H.R. and L.M. Levinson, "Low Temperature Electrical Studies in Metal Oxide Varistors - A Clue to Conduction Mechanisms," Journal of Applied Physics, Vol. 48, April 1977, pp. 1621-1627. [3] Philipp, H.R. and L.M. Levinson, "Zinc Oxide for Tran- sient Suppression," IEEE Trans. PHP, December 1977. [4] "Surge Arresters for Alternating Current Power Circuits," ANSI Standard C62.1 , IEEE Standard 28. [5] "Lightning Arresters. Part I: Nonlinear Resistor Type Arresters for AC Systems," IEC Recommendation 99-1,1970. [6] Matsuoka, M., T. Masuyama and Y. lida, "Supplemen- tary Journal of Japanese Society of Applied Physics," Vol. 39, 1970, pp. 94-101. [7] Harnden, J.D., F.D. Martzloff, W.G. Morris and F.B. Golden, "Metal-Oxide Varistor: A New Way to Suppress Transients," Electronics, October 2, 1972. [8] Martzloff, F.D., "The Development of a Guide on Surge Voltages in Low - Voltage AC Power Circuits," Report 81CRD047, General Electric, Schenectady, New York, 1981. [9] Martzloff, F.D., "Varistor versus Environment: Winning the Rematch," Report 85CRD037, General Electric, Schenectady, New York, May 1985. 2-14 TVS HARRIS VARISTORS - BASIC PROPERTIES, TERMINOLOGY AND THEORY PAGE HARRIS VARISTORS - BASIC PROPERTIES, TERMINOLOGY AND THEORY 3-3 What Is A Harris Varistor? 3-3 Physical Properties 3-3 Varistor Construction 3-5 Electrical Characterization 3-6 Varistor Terminology 3-11 References 3-13 3-1 Harris Varistors - Basic Properties, Terminology and Theory What Is A Harris Varistor? Varistors are voltage dependent, nonlinear devices which have an electrical behavior similar to back-to-back zener diodes. The symmetrical, sharp breakdown characteristics shown in Figure 1 enable the varistor to provide excellent transient suppression performance. When exposed to high voltage transients the varistor impedance changes many orders of magnitude from a near open circuit to a highly con- ductive level, thus clamping the transient voltage to a safe level. The potentially destructive energy of the incoming transient pulse is absorbed by the varistor, thereby protect- ing vulnerable circuit components. "1 PERVERT DIVImA PER HORIZ DIV 50V gm PER DIV FIGURE 1. TYPICAL VARISTOR V-l CHARACTERISTIC The varistor is composed primarily of zinc oxide with small additions of bismuth, cobalt, manganese and other metal oxides. The structure of the body consists of a matrix of con- ductive zinc oxide grains separated by grain boundaries pro- viding P-N junction semiconductor characteristics. These boundaries are responsible for blocking conduction at low voltages and are the source of the nonlinear electrical con- duction at higher voltages. Since electrical conduction occurs, in effect, between zinc oxide grains distributed throughout the bulk of the device, the Harris Varistor is inherently more rugged than its single P-N junction counterparts, such as zener diodes. In the varistor, energy is absorbed uniformly throughout the body of the device with the resultant heating spread evenly through its volume. Electrical properties are controlled mainly by the physical dimensions of the varistor body which is sintered in various form factors such as discs, chips and tubes. The energy rating is determined by volume, voltage rating by thick- ness or current flow path length, and current capability by area measured normal to the direction of current flow. Harris Varistors are available with AC operating voltages from 2.5V to 60OOV. Higher voltages are limited only by packaging ability. Peak current handling exceeds 70.000A and energy capability extends beyond 10.000J for the larger units. Pack- age styles include the tiny multilayer surface mount suppres- sors, tubular devices for use in connectors, and progress in size up to the rugged industrial device line. Physical Properties Introduction An attractive property of the metal oxide varistor, fabricated from zinc oxide (ZnO), is that the electrical characteristics are related to the bulk of the device. Each ZnO grain of the ceramic acts as if it has a semiconductor junction at the grain boundary. A cross-section of the material is shown in Figure 2, which illustrates the ceramic microstructure. The ZnO grain boundaries can be clearly observed. Since the nonlinear electrical behavior occurs at the boundary of each semiconducting ZnO grain, the varistor can be considered a "multi-junction" device composed of many series and parallel connections of grain boundaries. Device behavior may be analyzed with respect to the details of the ceramic micro- structure. Mean grain size and grain size distribution play a major role in electrical behavior. |-« 100n »-J FIGURE 2. OPTICAL PHOTOMICROGRAPH OF A POLISHED AND ETCHED SECTION OF A VARISTOR Varistor Microstructure Varistors are fabricated by forming and sintering zinc oxide- based powders into ceramic parts. These parts are then electroded with either thick film silver or arc/flame sprayed metal. The bulk of the varistor between contacts is com- prised of ZnO grains of an average size "d" as shown in the schematic model of Figure 3. Resistivity of the ZnO is <0.3£2-cm. v> 5 UJ O — UJ °i 0. UJ 3-3 Harris Varistor Basic Properties, Terminology and Theory CURRENT TABLE 1. INTERGRANULAR lOUNDARY FIGURE 3. SCHEMATIC DEPICTION OF THE MICROSTRUC- TURE OF A METAL-OXIDE VARISTOR. GRAINS OF CONDUCTING ZnO (AVERAGE SIZE d) ARE SEPA- RATED BY INTERGRANULAR BOUNDARIES Designing a varistor for a given nominal varistor voltage, V N , is basically a matter of selecting the device thickness such that the appropriate number of grains, n, are in series between electrodes. In practice, the varistor material is char- acterized by a voltage gradient measured across its thickness by a specific volts/mm value. By controlling composition and manufacturing conditions the gradient remains fixed. Because there are practical limits to the range of thicknesses achiev- able, more than one voltage gradient value is desired. By altering the composition of the metal oxide additives it is pos- sible to change the grain size "d" and achieve the desired result. A fundamental property of the ZnO varistor is that the volt- age drop across a single interface "junction" between grains is nearly constant. Observations over a range of composi- tional variations and processing conditions show a fixed volt- age drop of about 2V-3V per grain boundary junction. Also, the voltage drop does not vary for grains of different sizes. It follows, then, that the varistor voltage will be determined by the thickness of the material and the size of the ZnO grains. The relationship can be stated very simply as follows: Varistor Voltage, V N (DC) Where, and, varistor thickness, where, (3V)n average number grain boundaries tween electrodes 1)d average grain size VARISTOR VOLTAGE AVERAGE GRAIN SIZE n GRADIENT DEVICE THICKNESS VOLTS MICRONS V/mm AT ImA mm 150V HMS 20 75 150 1.5 25V RMS 80 (Note) 12 39 1.0 NOTE: Low voltage formulation. Theory of Operation Because of the polycrystalline nature of metal-oxide semicon- ductor varistors, the physical operation of the device is more complex than that of conventional semiconductors. Intensive measurement has determined many of the device's electrical characteristics, and much effort continues to better define the varistor's operation. In this section we will discuss some theo- ries of operation, but from the user's viewpoint this is not nearly as important as understanding the basic electrical properties as they relate to device construction. The key to explaining metal-oxide varistor operation lies in understanding the electronic phenomena occurring near the grain boundaries, or junctions between the zinc oxide grains. While some of the early theory supposed that electronic tun- neling occurred through an insulating second phase layer at the grain boundaries, varistor operation is probably better described by a series-parallel arrangement of semiconduct- ing diodes. In this model, the grain boundaries contain defect states which trap free electrons from the n-type semi- conducting zinc oxide grains, thus forming a space charge depletion layer in the ZnO grains in the region adjacent to the grain boundaries.' 61 Evidence for depletion layers in the varistor is shown in Figure 4 where the inverse of the capacitance per boundary squared is plotted against the applied voltage per bound- ary.' 7 ' This is the same type of behavior observed for semi- conductor abrupt P-N junction diodes. The relationship is: 1 _ 2(V b + V) _2 qesN (10") 1 c 2 n 2 /c The varistor voltage, V N , is defined as the voltage across a varistor at the point on its V-l characteristic where the transition is complete from the low-level linear region to the highly nonlinear region. For standard measurement purposes, it is arbitrarily defined as the voltage at a current of 1 mA. Some typical values of dimensions for Harris varistors are given in Table 1 . 0.4 0.8 V A PER BOUNDARY FIGURE 4. CAPACITANCE-VOLTAGE BEHAVIOR OF VARISTOR RESEMBLES A SEMICONDUCTOR ABRUPT-JUNC- TION REVERSED BIASED DIODE Nd -2x 101 7/cm3 3-4 Harris Varistor Basic Properties, Terminology and Theory Where V b is the barrier voltage, V the applied voltage, q the electron charge, the semiconductor permittivity and N is the carrier concentration. From this relationship the ZnO car- rier concentration, N, was determined to be about 2 x I0 17 per cm 3 . 17 ' In addition, the width of the depletion layer was calculated to be about 1000 Angstrom units. Single junction studies also support the diode model.' 91 It is these depletion layers that block the free flow of carriers and are responsible for the low voltage insulating behavior in the leakage region as depicted in Figure 5. The leakage current is due to the free flow of carriers across the field lowered barrier, and is thermally activated, at least above about 25°C. FIGURE 5. ENERGY BAND DIAGRAM OF A ZnO-GRAIN- BOUNDARY-ZnO JUNCTION Figure 5 shows an energy band diagram for a ZnO-grain boundary-ZnO junction. The left-hand grain is forward biased, V L , and the right side is reverse biased to V R . The depletion layer widths are X L and X R , and the respective barrier heights are <|> L and <)> R . The zero biased barrier height is (|) . As the voltage bias is increased, $ L is decreased and 4> R is increased, leading to a lowering of the barrier and an increase in conduction. The barrier height c)> L of a low voltage varistor was measured as a function of applied voltage' 11 !, anc j j s presented in Figure 6. The rapid decrease in the barrier at high voltage represents the onset of nonlinear conduction. [12] Transport mechanisms in the nonlinear region are very com- plicated and are still the subject of active research. Most the- ories draw their inspiration from semiconductor transport theory and the reader is referred to the literature for more information.! 3 ' 5 ' 13 ' 14 ' 15 1 ^ 1.0 £ O 4 8 12 16 2 VOLTAGE (V) FIGURE 6. THERMAL BARRIER AS A FUNCTION OF APPLIED VOLTAGE Turning now to the high current upturn region in Figure 10, we see that the V-l behavior approaches an ohmic characteristic. The limiting resistance value depends upon the electrical con- ductivity of the body of the semiconducting ZnO grains, which have carrier concentrations in the range of 10 1 ' to 10 18 per cm 3 . This would put the ZnO resistivity below 0.3Qcm. Varistor Construction The process of fabricating a Harris Varistor is illustrated in the flow chart of Figure 7. The starting material may differ in the composition of the additive oxides, in order to cover the volt- age range of product. in £ lu o E £ °i cc cc Q. UJ ZnO ADDITIVE OXIDES (MAINLY BL 2 3 ) MIXING I POWDER PREPARATION FORM CERAMIC BODY MECHANICAL ASSEMBLY [encapsulate] FINAL PRODUCT TO * ELECTRICAL TEST PACKAGE AS/IF REQUIRED FIGURE 7. SCHEMATIC FLOW DIAGRAM OF HARRIS VARIS- TOR FABRICATION Harris Varistor Basic Properties, Terminology and Theory Device characteristics are determined at the pressing opera- tion. The powder is pressed into a form of predetermined thickness in order to obtain a desired value of nominal volt- age. To obtain the desired ratings of peak current and energy capability, the electrode area and mass of the device are varied. The range of diameters obtainable in disc prod- uct offerings is listed here: TABLE 2. BY-TYPE CERAMIC DIMENSIONS(Continued) Nominal Disc 3 5 7 10 14 20 32 40 52 62 Diameter - mm Of course, other shapes, such as rectangles, are also possi- ble by simply changing the press dies. Other ceramic fabri- cation techniques can be used to make different shapes. For example, rods or tubes are made by extruding and cutting to length. After forming, the green (i.e. unfired) parts are placed in a kiln and sintered at peak temperatures in excess of 1200°C. The bismuth oxide is molten above 825°C, assist- ing in the initial densification of the polycrystalline ceramic. At higher temperatures, grain growth occurs, forming a structure with controlled grain size. Electroding is accomplished, for radial and chip devices, by means of thick film silver fired onto the ceramic surface. Wire leads or strap terminals are then soldered in place. A conductive epoxy is used for connecting leads to the axial 3mm discs. For the larger industrial devices (40mm and 60mm diameter discs) the contact material is arc sprayed aluminum, with an overspray of copper if necessary to give a solderable surface. Many encapsulation techniques are used in the assembly of the various Harris Varistor packages. Most radials and some industrial devices (HA Series) are epoxy coated in a fluidised bed, whereas epoxy is "spun" onto the axial device. Radials are also available with phenolic coatings applied using a wet process. The PA series package consists of plastic molded around a 20mm disc subassembly. The RA, DA, and DB series devices are all similar in that they all are composed of discs or chips, with tabs or leads, encased in a molded plas- tic shell filled with epoxy. Different package styles allow vari- ation in energy ratings, as well as in mechanical mounting. Figures 8 and 9 illustrate several package forms. Figure 9 shows construction details of some packages. Dimensions of the ceramic, by package type, are given in Table 2. TABLE 2. BY-TYPE CERAMIC DIMENSIONS PACKAGE TYPE SERIES CERAMIC DIMENSIONS Direct Sur- face Mount CH, AUML, ML Series 5mm x 8mm Chip, 0805, 1206, 1210, 1812, 2220 Connector Pin CP, CS Series 22, 20, 16 ID Gauge Tube Axial Leaded MA Series 3mm Diameter Disc Radial Leaded ZA, LA, "CHI Series 5mm, 7mm, 10mm, 14mm, 20mm Diameter Discs PACKAGE TYPE SERIES CERAMIC DIMENSIONS Radial Leaded Low Profile RA Series 5mmx8mm,10mmx16mm, 14x22 Chips Power PA Series 20mm Diameter Disc Industrial Packages HA Series DA, DB Series BA, BB Series 32mm, 40mm Diameter Disc 40mm Diameter Disc 60mm Diameter Disc Industrial Discs CA, NA Series 32mm, 40, 60mm Diameter Discs 34mm Square Arrester AS Series 32mm, 42mm, 60mm Diameter Discs Electrical Characterization Varistor VI Characteristics Varistor electrical characteristics are conveniently displayed using log-log format in order to show the wide range of the V-l curve. The log format also is clearer than a linear representation which tends to exaggerate the nonlinearity in proportion to the current scale chosen. A typical V-l characteristic curve is shown in Figure 10. This plot shows a wider range of current than is normally provided on varistor data sheets in order to illustrate three distinct regions of electrical operation. LEAKAGE REGION NORMAL VARISTOR OPERATION UPTURN REGION — 200 m § 100 § 50 SLC iPE = 1 a o - 1 = kV if II ' tt ' II • (TYF >ICA . vi: ola: OA) 10-* 10" 2 10° CURRENT (A) 10 2 FIGURE 10. TYPICAL VARISTOR V-l CURVE PLOTTED ON LOG-LOG SCALE Equivalent Circuit Model An electrical model for the varistor can be represented by the simplified equivalent circuit of Figure 11 . 3-6 Harris Varistor Basic Properties, Terminology and Theory Harris Varistor Basic Properties, Terminology and Theory FIGURE 9D. PICTORIAL VIEW OF HIGH ENERGY PACKAGES, DA, DB, AND BA/BB SERIES 3-8 Harris Varistor Basic Properties, Terminology and Theory L (LEAD INDUCTANCE) (TYPICAL V130LA20A) The relation between the leakage current, I, and tempera- ture, T, is: -Vs/kT FIGURE 11. VARISTOR EQUIVALENT CIRCUIT MODEL Leakage Region of Operation At low current levels, the V-l Curve approaches a linear (ohmic) relationship and shows a significant temperature dependence. The varistor is in a high resistance mode (approaching 10 9 Q) and appears as an open circuit. The nonlinear resistance component, R x , can be ignored because R 0FF in parallel will predominate. Also, R 0N will be insignificant compared to Roff- FIGURE 12. EQUIVALENT CIRCUIT AT LOW CURRENTS For a given varistor device, capacitance remains approxi- mately constant over a wide range of voltage and frequency in the leakage region. The value of capacitance drops only slightly as voltage is applied to the varistor. As the voltage approaches the nominal varistor voltage, the capacitance abruptly decreases. Capacitance remains nearly constant with frequency change up to 100kHz. Similarly, the change with temperature is small, the 25°C value of capacitance being well within ±10% from -40°C to +125°C. The temperature effect of the V-l characteristic curve in the leakage region is shown in Figure 13. A distinct temperature dependence is noted. 100 80 ? o 5I K w UJ 30 SI >ECIM Eh V13( L/l 10A '25/5 M 75/1 I 125°C I 10 - * 10 -4 10 -7 10" 6 10" 5 10" 4 10 3 10" 2 VARISTOR CURRENT (A DC ) FIGURE 13. TEMPERATURE DEPENDENCE OF THE CHARAC- TERISTIC CURVE IN THE LEAKAGE REGION l = l e where: b k Vr constant Boltzmann's Constant 0.9eV The temperature variation, in effect, corresponds to a change in Roff- However, Roff remains at a high resis- tance value even at elevated temperatures. For example, it is still in the range of 10MQ to 100MQ at 125°C. Although R 0FF is a high resistance it varies with frequency. The relationship is approximately linear with inverse fre- quency. r off ~ { However, the parallel combination of Roff and C is predom- inantly capacitive at any frequency of interest. This is because the capacitive reactance also varies approximately linearly with 1/f. At higher currents, at and above the milliamp range, tempera- ture variation becomes minimal. The plot of the temperature coefficient (DV/DT) is given in Figure 14. It should be noted that the temperature coefficient is negative and decreases as current rises. In the clamping voltage range of the varistor (I > 1 A), the temperature dependency approaches zero. S -°-2 O LU -0.3 E a! -0.5 NORMAL LEAKAGE REGION OPERATION SAN — V13 1 PLE TYPE ^V22Z A3 f 10- 5 10- 4 10 z 10-' 10° CURRENT (A) Typical Temperature Coefficient of Voltage vs Current, 14mm Size, 55°Cto+125°C. FIGURE 14. RELATION OF TEMPERATURE COEFFICIENT DV/DT TO VARISTOR CURRENT Normal Varistor Region of Operation The varistor characteristic follows the equation I = kV™, where k is a constant and the exponent a defines the degree of nonlinearity. Alpha is a figure of merit and can be deter- mined from the slope of the V-l curve or calculated from the formula: log(l 2 /l,) log(V 2 /V,) log(V 1 2 /V,) ""'a^r 10 3-9 Harris Varistor Basic Properties, Terminology and Theory In this region the varistor is conducting and R x will predomi- nate over C, R n a nd r off • R x becomes many orders of magnitude less than R ff but remains larger than R ON . FIGURE 15. EQUIVALENT CIRCUIT AT VARISTOR CONDUC- TION During conduction the varistor voltage remains relatively constant for a change in current of several orders of magni- tude. In effect, the device resistance, R x , is changing in response to current. This can be observed by examining the static or dynamic resistance as a function of current. The static resistance is defined by: r - v x ~ J and the dynamic resistance by: Z„ = ^ = V/al = R„/a Plots of typical n Figure 16. values vs current, I, are given in 0.1 1 10 100 PEAK CURRENT (A) FIGURE 16A. R x STATIC VARISTOR RESISTANCE FIGURE 0.1 1.0 10 PEAK CURRENT (A) FIGURE 16B. Z x DYNAMIC VARISTOR RESISTANCE Upturn Region of Operation At high currents, approaching the maximum rating, the varis- tor approximates a short-circuit. The curve departs from the nonlinear relation and approaches the value of the material bulk resistance, about 1Q-10Q. The upturn takes place as R x approaches the value of Rqn- Resistor R 0N represents the bulk resistance of the zinc oxide grains. This resistance is linear (which appears as a steeper slope on the log plot) and occurs at currents 50A to 50.000A, depending on the varistor size. FIGURE 17. EQUIVALENT CIRCUIT AT VARISTOR UPTURN Speed of Response and Rate Effects The varistor action depends on a conduction mechanism sim- ilar to that of other semiconductor devices. For this reason, conduction occurs very rapidly, with no apparent time lag - even into the nanosecond range. Figure 18 shows a compos- ite photograph of two voltage traces with and without a varis- tor inserted in a very low inductance inpulse generator. The second trace (which is not synchronized with the first, but merely superimposed on the oscilloscope screen) shows that the voltage clamping effect of the varistor occurs in less than one nanosecond. In the conventional lead-mounted devices, the inductance of the leads would completely mask the fast action of the varis- tor; therefore, the test circuit for Figure 18 required insertion of a small piece of varistor material in a coaxial line to dem- onstrate the intrinsic varistor response. 1 ' 1 TRACE 1 LOAD VOLTAGE ~ WITHOUT VARISTOR 1 TR LO 4CE2 AD VO CL VA LTAGE IVMPED B\ 1ISTOR 1 500ps/DIV. FIGURE 18. RESPONSE OF A ZnO VARISTOR TO A FAST RISE TIME (500ps) PULSE Tests made on lead mounted devices, even with careful attention to minimizing lead length, show that the voltages induced in the loop formed by the leads contribute a sub- stantial part of the voltage appearing across the terminals of a varistor at high current and fast current rise. Fortunately, 3-10 Harris Varistor Basic Properties, Terminology and Theory the currents which can be delivered by a transient source are invariably slower in rise time than the observed voltage transients. The applications most frequently encountered for varistors involve current rise times longer than 0.5(is. Voltage rate-of-rise is not the best term to use when discussing the response of a varistor to a fast impulse (unlike spark gaps where a finite time is involved in switching from non-conducting to conducting state). The response time of the varistor to the transient current that a circuit can deliver is the appropriate characteristic to consider. The V-l characteristic of Figure 19A shows how the response of the varistor is affected by the current waveform. From such data, an "overshoot" effect can be defined as being the relative increase in the maximum voltage appearing across the varistor during a fast current rise, using the conventional 8/20us current wave as the reference. Figure 19B shows typical clamping voltage variation with rise time for various current levels. Varistor Terminology The following tabulation defines the terminology used in varistor specifications. Existing standards have been followed wherever possible. Definitions (IEEE Standard C62.33, 1982) A characteristic is an inherent and measurable property of a device. Such a property may be electrical, mechanical, or thermal, and can be expressed as a value for stated conditions. A rating is a value which establishes either a limiting capability or a limiting condition (either maximum or minimum) for operation of a device. It is determined for specified values of environment and operation. The ratings indicate a level of stress which may be applied to the device without causing degradation or failure. Varistor symbols are defined on the linear V-l graph illustrated in Figure 20. 100 200 400 600 1000 2000 PEAK CURRENT (A) FIGURE 19A. V-l CHARACTERISTICS FOR VARIOUS CURRENT RISE TIMES OA 0.6 0.8 1 2 PULSE RISE TIME (us) FIGURE 19B. OVERSHOOT DEFINED WITH REFERENCE TO THE BASIC 8/20ms CURRENT PULSE CO £ UJ O E £ DC CC CL lli NOTE: Refer to Section 7, Maximum Clamping Voltage FIGURE 19. RESPONSE OF LEAD-MOUNTED VARISTORS TO CURRENT WAVEFORM •■pq 1000 V N(DC) VOLTAGE (V) FIGURE 20. I-V GRAPH ILLUSTRATING SYMBOLS AND DEFINITIONS 3-11 Harris Varistor Basic Properties, Terminology and Theory TABLE 3. VARISTOR CHARACTERISTICS (IEEE STANDARD C62.33-1982 SUBSECTION 2.3 AND 2.4) TERMS AND DESCRIPTIONS SYMBOL Clamping Voltage. Peak voltage across the varistor measured under conditions of a specified peak V c pulse current and specified waveform. NOTE: Peak voltage and peak currents are not necessarily coincidental in time. Vc Rated Peak Single Pulse Transient Currents (Varistor). Maximum peak current which may be applied for a single 8/20(is impulse, with rated line voltage also applied, without causing device failure. '™ Lifetime Rated Pulse Currents (Varistor). Derated values of l TM for impulse durations exceeding that of an 8/20ns waveshape, and for multiple pulses which may be applied over device rated lifetime. Rated RMS Voltage (Varistor). Maximum continuous sinusoidal RMS voltage which may be applied. Vmiac) Rated DC Voltage (Varistor). Maximum continuous DC voltage which may be applied. V M(DC) DC Standby Current (Varistor). Varistor current measured at rated voltage, V M(DC) . Id For certain applications, some of the following terms may be useful. Nominal Varistor Voltage. Voltage across the varistor measured at a specified pulsed DC current, l N(DC j. of specific duration. Injdc) °* specific duration. Impc) ' s specified by the varistor manufacturer. V N(DC) Peak Nominal Varistor Voltage. Voltage across the varistor measured at a specified peak AC current, In(acv °' specific duration. Iniac) ' s specified by the varistor manufacturer. Vn(AC) Rated Recurrent Peak Voltage (Varistor). Maximum recurrent peak voltage which may be applied for a specified duty cycle and waveform. V PM Rated Single Pulse Transient Energy (Varistor). Energy which may be dissipated for a single impulse of maximum rated current at a specified waveshape, with rated RMS voltage or rated DC voltage also applied, without causing device fain ire W TM Rated Transient Average Power Dissipation (Varistor). Maximum average power which may be dissipated due to a group of pulses occurring within a specified isolated time period, without causing device failure. Pt(av)m Varistor Voltage. Voltage across the varistor measured at a given current, l x . V x Voltage Clamping Ratio (Varistor). A figure of merit measure of the varistor clamping effectiveness as defined by the symbols V a. 4-1 Varistor Products Introduction Harris Varistors represent the sate-of-the-art in metal-oxide varistor technology, offering high energy capabilities and excellent voltage clamping characteristics. Harris Varistors are voltage dependent, symmetrical clamping, metal-oxide semiconductor devices. Their characteristics enable them to protect circuits against high voltage spikes (when properly selected) to meet anticipated transients. When the protected equipment or circuit encounters high voltage spikes, the varistor impedance changes from a very high standby value to a very low conducting value, thus clamping the transient voltage to a protective level. The excess energy of the incoming high voltage pulse is absorbed by the Harris Varistor, protecting voltage sensitive components against damage. The protection afforded by the Harris Varistors not only guards expensive and voltage sensitive equipment from physical damage, but also improves functional reliability in components that can encounter temporary upset due to transient voltages of lower amplitudes. A Broad Range of Products to Fit Every Transient Voltage Suppression Need Wide Voltage/Energy Range Excellent Clamp Ratio Fast Response Time Low Standby Power ISO 9000 Approved IEC Conformance No Follow-On Current DESC (QPL) Parts Special Products for Special Applications • UL Recognized • Rad Hard • CSA Recognized • CECC Approved CH SERIES SURFACE-MOUNT VARISTORS I UL/CSA Recognized Higher Reliability Save on Board Real Estate Increases Circuit Density BB, BA, DA, DB, HA SERIES • High Energy • Isolated Capability • Low Inductance • Rigid Terminals • UL/CSA Recognized • Improved Creep and Strike • Low Profile • High Temperature Capability • In-Line Leads • Precise Seating Plane • UL/CSA Recognized AUML/ML SERIES Surface Mount Significant Size Reduction High Reliability ZA SERIES Radial Package Low Voltage Operation UL/CSA Recognized CECC Approved CS/CP SERIES CONNECTOR PIN VARISTORS Provides Protection in Connectors 22, 20 and 16 Pin Gauge Size Rad Hard • Compact Size Solderable MA SERIES Axial Package Wide Voltage Automatic Insertion HIGH-RELIABILITY SERIES 100% Prescreened 100% Process Conditioning Meets Military Specifications OESC (QPL) Parts Rad Hard CECC "C"III/LA SERIES • Radial Package • Line Voltage Operation • UL/CSA Recognized • CECC Approved f£<£ 2p 5 ° > Cl PA SERIES • Rigid Mountdown • NEMA Creep and Strike Distance • Quick Connect Terminal • UL/CSA Recognized NA, CA SERIES • Industrial Discs • Solderable Contacts • Edge Passivation AS SERIES Arrester Discs 4-3 Varistor Products Concepts of Transient Voltage Protection Varistor characteristics are measured at high current and energy levels of necessity with an impulse waveform. Shown below is the ANSI STD C62.1 waveshape, an exponentially decaying waveform representative of lightning surges, and the discharge of stored energy in reactive circuits. See Fig- ures 1 and 2. 100WDIV 10A/DIV 10H8/DIV 8/20ns TEST WAVE, l P -315V, V130LA10A FIGURE 1. I-*- VIRTUAL FRONT DURATION w_ 1.25 x RISE TIME FROM 10% TO 90% PEAK CURRENT(A) FIGURE 2. PEAK CURRENT TEST IMPULSE WAVE Sp.s FRONT DURATION/20ps IMPULSE DURATION, EXCEPT AS NOTED Based on industry practices, the 8/20us current wave (8us rise and 20ns to 50% decay of peak value) is used as a standard for current (l TM ) and clamp voltage (V c ) ratings shown in the specification tables and curves. Ratings for other waves of different decay times are shown specifically on the pulse life derating curves. For the energy rating (W TM ), a longer duration waveform of 1 0/1 000ns is used. This condition is more representative of the high energy surges usually experienced from inductive dis- charge of motors and transformers. Harris Varistors are rated for a maximum pulse energy surge that results in a varistor voltage V ND ( C j shift of less than ±(10% + 1 V) of initial value. To determine the energy absorbed in a varistor the following equation applies: E = KV c It where I is the peak current applied, V c is the clamp voltage which results, x is the pulse width and K is a constant. K val- ues are 1.0 for a rectangular wave, 1.4 for a 10/1000us wave and for a 8/20us wave. Note that the rated energy (W TM ) and the energy absorbed in a varistor may not be identical. A specimen with lower clamping voltage will absorb less energy. This effect tends to be greatest at rated peak current (l TM ) with an 8/20us wave. It is important to note, as demonstrated by the above equation, that poorer varistors must absorb higher energy levels than the better performance varistors with lower clamp voltages, yet they actually provide less overvoltage protection. For that reason, energy ratings based on an 8/20us pulse tend to overstate varistor capability. The 10/1000us waveform consequently gives a more realistic The measured response time of a varistor is influenced by lead configuration and length. In a typical application, the response time is shorter than the inductive lead effect. In a coaxial configuration, one could show response times of less than a few nanoseconds. See Figure 18, Section 3. TABLE 1. TERM DEFINITIONS TERM DEFINITION DC Voltage, V M(DC) Maximum allowable steady state DC applied voltage, DC standby current, l D 20|iA typical, 200mA maximum at T A = 25°C, except V18ZA to V36ZA 20mm size: l D = 200nA (typ), 3mA max and U24RA22 to V36RA22. RMS Voltage, V M(AC) Maximum allowable steady state sinusoidal volt- age (RMS) at 50HZ-60Hz. If a nonsinusoidal waveform is applied, the recurrent peak voltage should be limited to V2xV M(AC ). Energy, W TM Maximum allowable energy for a single impulse of 10/1 000ns current waveform. Energy rating based on a V N shift of less than ±10%. Peak Current, Maximum allowable peak current for a single im- pulse of 8/20|iS waveform with rated continuous voltage applied. See pulse lifetime rating curves for other conditions. Varistor Voltage, V N(DC) Varistor peak terminal voltage measured with a specified current applied. For DC conditions, 1mA is applied for a duration of 20ms to 1s. For AC con- ditions 1mA peak 60Hz wave is applied. Clamping Voltage, V c Maximum terminal voltage measured with an applied 8/20ns impulse of a given peak current. See V-l curves and table for product ratings of clamping voltage over the allowable range of peak impulse current. Capacitance Typical values measured at a test frequency of 1.0MHz. Maximum capacitance can be 100% higher than the typical value measured at 1 .0MHz. 4-4 Varistor Products PEAK CURRENT (A) 80- 500 150- 1000 1,200- 9000 25,000 - 40,000 ENERGY (J) 0.07- 1.7 270- 1,050 MAXIMUM STEADY-STATE APPLIED VOLTAGE VOLTS AC RMS 4 10 25 __1 L_l VOLTS DC 3.5 14 35 150 130 I I 200 175 I 264 250 275 I I I 4S0 660 750 _l I l_ 1,000 2,800 —I 1 6,000 L ^CP, CS SERIESN 330 369 I I I 615 850 970 1,200 3,500 _l I I I I 7,000 HA, DA/ DB SERIES 0\V\ DISC SIZES/ PACKAGES 22, 20, 16 GAUGE 0805 1812 1206 2220 <4 1210 ^ 5 x8mm 5x8,10x16, 14x22 (mm) 7, 10, 14, 20 (mm) 20mm ^J^b^j=> 32, 40 (mm) EC {2 °§ > Q. FIGURE 3. VARISTOR PRODUCT FAMILY SELECTION GUIDE TABLE 2. SERIES RA AUML, CH, CP, CS, ML LA, ZA MA (NOTE 1) PA DA, DB, HA BA, BB CA, NA AS Operating Ambient Temperature (w/out derating) -55 to +125°C -55 to +125°C -55 to +85°C -55 to +85°C -55 to +85°C -55 to +85°C -55 to +85°C -55 to +85°C -55 to +60°C Storage Temperature -55 to +150°C -55 to +150°C -55 to +125°C -55 to +125°C -55 to +125°C -55 to +125°C -55 to +125°C -55 to +125°C -55 to +80°C HiPot Encapsulation (Note 2) 2500 NA 2500 1000 NA 5000 5000 NA NA Voltage Temperature Coefficient (Vc at Specified Test Current) <.01%/°C <.01W°C <.01%/°C <.01%/°C <.01%/°C <01%/°C <.01%/°C <.01W°C <.01%/°C Insulation Resistance (M£l) >1000 NA >1000 >1000 NA >1000 >1000 NA NA NOTES: 1 . Base Plate Temperature. Solderability: Per MIL STD 202, Method 208C. 2. Dielectric withstand per MIL STD 202, Method 301, 2500 V DC , for 1 minute. 4-5 Varistor Products Varistor Safety Precautions Should the varistor be subjected to surge currents and energy levels substantially above maximum ratings, it may physically fail by package rupture or expulsion of material. It is recommended that protective fusing be used as described in Section 4. If not fused, the varistor should be located away from other components or be physically shielded from them. Harris Varistor encapsulant complies with flammability requirements of Underwriters Laboratories Standard UL1414 and has a flammability rating of 94V-0. AUML, CH, CP.CS, ML, RA SERIES 7 -xc — J BA/BB, CA, "C" III, DA/DB, HA, LA, MA, NA, PA, ZA SERIES J I II II 70 80 AMBIENT TEMPERATURE (°C) FIGURE 4. CURRENT POWER, ENERGY RATING vs TEMPERATURE LEAKAGE REGION NORMAL I OPERATION SAMPLE TYPE viani A10A V22Z A3 10 s 10" 4 10' 3 10' 2 10" 1 10° CURRENT (A) 10 1 10 2 10 3 FIGURE 5. TYPICAL TEMPERATURE COEFFICIENT OF VOLT- AGE vs CURRENT, 14mm SIZE, -55°C TO +125°C How to Select a Harris Varistor To select the correct Harris Varistor for a determine the following information: 1 . What is system RMS or DC voltage? A. Phase to Ground B. Phase to Phase lion, 2. How will the Harris Varistor be connected? A. Phase to Ground B. Phase to Phase 3. Calculate required varistor voltage at 10%-25% above system RMS or DC voltage. A - V PHASE TO GROUND x 1 - 1 - - B - V PHASE TO PHASE x 1 ■ 1 = — The maximum continuous RMS or DC varistor voltage should be equal to or greater than either 3A or 3B. This maximum continuous RMS or DC varistor voltage can be found in the rating and characteristic tables V M(AC) or V M(DC)- 4. Selecting the correct varistor voltage is reasonably straightforward, but selecting the proper energy rating is more difficult and normally presents a certain degree of uncertainty. Choosing the highest energy rating available is expedient, but usually not cost effective. As economic considerations enter the selection process, the worst case size of the transient, the frequency of occurrence, and the life expectancy of the equipment to be protected cannot be ignored. ANSI/IEEE C62.41-1980 addresses these consider- ations, and the reprint in Section 1 gives the background and the environment description of this standard. From ANSI/IEEE C62.41-1980 it becomes evident that the equipment or component to be protected is not as impor- tant as the location in the electrical system. ANSI/IEEE C62.41-1980 divides the electrical distribution system into 3 location categories. Figure 6 defines these loca- tion categories in detail. Table 3 shows the open circuit voltage and short circuit current of the transients which can be expected at loca- tion A and B. The Harris Varistor selected must first survive the worst case transient (see "Medium Exposure Amplitude" in Table 3) and, secondly, clamp the maximum open circuit voltages to levels which will not damage equipment or components in the system to be protected. 5. Select proper location category, A or B. 6. Determine worst case transient current and voltage from Table 3. 7. Knowing the maximum continuous RMS or DC varistor voltage (from 3), determine maximum clamping voltage from V-l curve for the device selected using the worst case transient current found in 6. 8. Does this clamping voltage provide the required protec- tion level? If not, repeat Step 7 using a higher energy-rat- ed device. If this process proves to be ineffective, consult your local Harris sales office for assistance. 9. In many cases the source of the transient is known. The transient energy can be calculated, and maximum clamp- ing voltage can be determined from the V-l characteristic since the maximum pulse current or source impedance is known. Examples of these calculations can be found in Section 4. 4-6 Varistor Products A. Outlets and Long Branch Circuits All outlets at more than 10m (30 feet) from Category B with wires #14-10 All outlets at more than 20m (60 feet) from Category C with wires #14-10 B. Major Feeders and Short Branch Circuits Distribution panel devices Bus and feeder systems in industrial plants Heavy appliance outlets with "short" connections to the service entrance Lighting systems in commercial buildings C. Outside and Service Entrance Service drop from pole to building entrance Run between meter and distribution panel Overhead line to detached buildings Underground lines to well pumps FIGURE 6. LOCATION CATEGORIES TABLE 3. SURGE VOLTAGES AND CURRENT DEEMED TO REPRESENT THE INDOOR ENVIRONMENT AND SUGGESTED FOR CONSIDERATION IN DESIGNING PROTECTIVE SYSTEMS IMPULSE ENERGY (JOULES) DEPOSITED IN A SUPPRESSOR (NOTE 3) WITH CLAMPING VOLTAGE OF LOCATION CATEGORY CENTER COMPARABLE TO IEC 664 CATEGORY WAVEFORM MEDIUM EXPOSURE AMPLITUDE TYPE OF SPECIMEN OR LOAD CIRCUIT 500V (120V SYSTEM) 1000V (240V SYSTEM) A. Long branch circuits and outlets II 0.5ns- 100kHz 6kV High Impedance (Note 1) 200A Low Impedance (Note 2) 0.8 1.6 B. Major feeders short branch circuits, and load center III 1.2/50ns 6kV High Impedance (Note 1 ) 8/20ns 3kA Low Impedance (Note 2) 40 80 0.5ns- 100kHz 6kV Low Impedance (Note 1) 500A High Impedance (Note 2) 2 4 NOTES: 1 . For high-impedance test specimens or load circuits, the voltage shown represents the surge voltage. In making simulation tests, use that value for the open-circuit voltage of the test generator. 2. For low-impedance test specimens or load circuits, the current shown represents the discharge current of the surge (not the short-circuit current of the power system). In making simulation tests, use that current for the short-circuit current of the test generator. 3. Other suppressors which have different clamping voltages would receive different energy levels. 4-7 Varistor Products How to Connect a Harris Varistor Transient suppressors can be exposed to high currents for short durations in the nanoseconds to millisecond time frame. Harris Varistors are connected in parallel to the load, and any voltage drop in the leads to the varistor will reduce its effectiveness. Best results are obtained by using short leads that are close together to reduce induced voltages and a low ohmic resistance to reduce I • R drops. Electrical Connections Single Phase LINE NEUTRAL This is the most complete protection one can select, but in many cases only Varistor 1 or Varistor 1 and 2 are selected. LINE GND SINGLE PHASE SINGLE PHASE 3 WIRE 120V/240V GND OR NEUTRAL ~7y 110V I 240V 120V + 120V _t_ T 240V 1 FIGURE 7. FIGURE 8. 3 Phase SUPPRESSOR CONNECTION 1-4 FIGURE 9A. 3 PHASE 220V/380V, UNGROUNDED SUPPRESSOR CONNECTION 1 -2 2- 3 3- 1 (380V) 1 FIGURE 9B. 3 PHASE 220V OR 380V, UNGROUNDED SUPPRESSOR CONNECTION 1- 2 2- 3 1-3 2MVj£"fc220V ■^r"220V" FIGURE 9C. 3 PHASE 220V, ONE PHASE GND LOWER VOLTAGE CONNECTION \ 1 -3 1 -2 {Si FIGURE 9D. 3 PHASE 220V SUPPRESSOR CONNECTION SUPPRESSOR CONNECTION If only 3 suppressor use 1-GND, 2-GND, 3-GND FIGURE 9E. 3PHASE120V/208V,4WIRE If only 3 suppressor use 1-GND, 2-GND, 3-GND FIGURE 9F. 3 PHASE 240V/415V FIGURE 9. For higher voltages use same connections, but select varistors for the appropriate voltage rating. 4-8 Varistor Products DC Applications DC applications require connection between plus and minus or plus and ground and minus and ground. For example, if a transient towards ground exists on all 3 phases (common mode transients) only transient suppres- sors connected phase to ground would absorb energy. Tran- sient suppressors connected phase to phase would not be effective. Y rV rV FIGURE 10A. INCORRECT FIGURE 10B. CORRECT FIGURE 10. COMMON MODE TRANSIENT AND CORRECT SOLUTION On the other hand if a differential mode of transient (phase to phase) exists then transient suppressors connected phase to phase would be the correct solution. DIFFERENTIAL MODE TRANSIENT / n. / / 44 FIGURE 11 A. INCORRECT FIGURE 11B. CORRECT FIGURE 11. DIFFERENTIAL MODE TRANSIENT AND CORRECT SOLUTION This is just a selection of some of the more important varia- tions in connecting transient suppressors. The logical approach is to connect the transient suppressor between the points of the potential difference created by the transient. The suppressor will then equalize or reduce these potentials to lower and harmless levels. 4-9 t March 1995 mgn energy ivietai-uxiae Arrester Blocks AS SERIES Features • Provided in Disc Form for Unique Packaging by Customer • Electrode Finish Enables Pressure Contact for Stacking Application • Available Disc Sizes: 32mm, 42mm and 60mm Diameter • No Follow Current • Large Surge Current Capability • Conforms to IEC 99-4 and ANSI/IEEE C62.11 Industry Standards Description AS series arresters are designed for protection from lightning and switching surges in high-power distribution equipment. Discs are designed to provide high-energy handling capabil- ity and long term stability in stressful applications. Applications • Lightning Protection of Electrical Distribution Trans- former and Systems • Arrester Assemblies of the Porcelain Polymeric, "Under-oil" and Metal Clad Variety Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Characteristics chart AS SERIES UNITS Rated Voltage AC Voltage Range 3.00 to 6.00 kV Steady State Applied Voltage: AC Voltage (MCOV) 2.55 to 5. 1 kV Transient Peak Pulse Current (l TM ) for 4/10 us Current Wave 65 to 100 kA Energy Rating for 2ms Current Wave 2.2 to 1 2 kJ Operating Ambient Temperature (T A ) 60 °C STORAGE AND HANDLING NOTES: 1 . Arrester discs should be stored in a moisture free environment at all times. 2. Use caution during handling to prevent chipping of edges. Copyright © Harris Corporation 1 995 4-11 File Number 2492.3 Specifications AS Series Device Ratings and Characteristics +25°c unless otherwise Specified PARAMETER MODEL NUMBER UNITS V302AS32 V402AS32 V502AS32 V602AS32 V302AS42 V402AS42 V502AS42 V402AS60 Rated Voltage (RMS) 3.0 4.0 5.0 6.0 3.0 4.0 5.0 4.0 kV Maximum Continuous Operating Voltage (MCOV) 2.55 3.40 4.25 5.1 2.55 3.40 4.25 3.40 kV Reference Current, l REF 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 mA Minimum Reference Voltage, V HEF 3.1 4.1 5.1 6.1 3.1 4.1 5.1 4.1 WrmS Nominal Discharge Current, l P (8/20>s) 5.0 5.0 5.0 5.0 10.0 10.0 10.0 10.0 kA Residual Voltage (max) at l P 9.8 13.1 16.3 19.6 10.0 13.3 16.7 12.5 kV Energy Rating at 60°C (2ms) 2.2 2.9 3.6 4.3 3.5 4.7 5.8 12.0 kj Peak Current, 4/1 Otis at 60°C (Note 2) 65.0 65.0 65.0 65.0 100.0 100.0 100.0 100.0 kA Maximum Steep Current Residual Voltage at 5kA (1/20us) 11.3 15.0 18.8 22.5 - - ■ ■ kV Maximum Steep Current Residual Voltage at 10kA (1/20ns) 11.5 15.3 19.2 14.4 kV Maximum Dissipation Power at MCOV 0.23 0.30 0.38 0.45 0.30 0.40 0.60 0.50 W Maximum Conduction Current at MCOV 75.0 75.0 75.0 75.0 110.0 110.0 110.0 140.0 MA DIMENSIONS (in millimeters) Diameter (0D) Min 32.3 32.3 32.3 32.3 40.9 40.9 40.9 60.0 mm Max 33.7 33.7 33.7 33.7 42.3 42.3 42.3 62.0 mm Height (H) Typical 21.0 28.0 36.0 42.0 21.0 28.0 36.0 34.0 mm NOTES: 1 . In addition to above standard types, custom ratings and dimensions can be provided. 2. Parts should be wrapped using a secondary insulating film or encased by polymeric housing. 4-12 Performance Curves AS Series 10 100 TIME (s) 1000 10000 FIGURE 1. TEMPORARY OVERVOLTAGE CAPABILITY (TOV) AS SERIES ARRESTERS 0.001 0.01 0.1 1 10 100 1000 10,000 ' PEAK IMPULSE CURRENT (A) FIGURE 2. V-l CHARACTERISTIC AS32 SIZE 0.1 1 10 100 1000 10,000 100,000 PEAK IMPULSE CURRENT (A) 0.1 1 10 100 1000 10,000 100,000 PEAK IMPULSE CURRENT (A) FIGURE 3. V-l CHARACTERISTIC AS42 SIZE FIGURE 4. V-l CHARACTERISTIC AS60 SIZE Dimensions PASSIVATION COLLAR ELECTRODE OF SPRAYED ALUMINIUM PARTICLES 4-13 SI SEMICONDUCTOR March 1995 Automotive AUML Series Multilayer Surface Mount Transient Surge Suppressors AUML SERIES Features • Load Dump Energy Rated per SAE Specification J 11 13 • Leadless Chip Form Surface Mount • "Zero" Lead Inductance • Variety of Energy Ratings Available • 125°C Continuous Operating Temperature • Low Profile, Compact Industry Standard Chip Size; (1210, 1812 and 2220 Sizes) • Inherently Bidirectional • No Plastic or Epoxy Packaging Assures Better than 94V-0 Flammabllity Rating Description The Automotive multilayer (AUML) series of transient surge suppressors was specifically designed to protect the sensitive electronic equipment of an automobile, from destructive transient voltages. The most common transient conditions result either from a large energy discharge or a steady state overvoltage. Almost all the electronic systems in the automobile, e.g. antilock brake systems, direct ignition systems, airbag control systems, wiper motors, etc., are susceptible to damage from voltage transients and thus require protection. The AUML transient suppressors have temperature independent protection characteristics and afford protection from -55°C to +125°C. Multilayer suppressors are designed to fail short when overstressed and, thus protect the associated equipment. The AUML sup- pressor is manufactured from semiconducting ceramics which offer rugged protection, excellent transient energy absorption and increased internal heat dissipation in an exceedingly small package. The devices are in chip form, eliminating lead inductance and assuring the fastest speed of response to transient surges. The AUML surge suppres- sors require significantly smaller space envelopes and land pads than traditional silicon TVS diodes or surface mount metal oxide varistors (MOVs), thus allowing designers to reduce size and weight while increasing system reliability. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Characteristics chart AUML SERIES UNITS Continuous: Steady State Applied Voltage: DC Voltage Range (V M(DC) ) 16 V Transient: Load Dump Energy, (W LD ) 3.0 to 25 J Jump Start Capability (5 minutes), (V JUMP ) 24.5 V Operating Ambient Temperature Range (T A ) -55 to +1 25 °C Storage Temperature Range (T STG ) -55 to +150 °C Temperature Coefficient (av) of Clamping Voltage (V c ) at Specified Test Current <0.01 V°C Copyright © Harris Corporation 1995 4-14 File Number 3387.2 Specifications AUML Series Device Ratings and Characteristics MODEL NUMBER MAXIMUM RATINGS (125°C) CHARACTERISTICS (25°C) MAXIMUM CONTINUOUS DC VOLTAGE JUMP START VOLTAGE (5 MIN) LOAD DUMP ENERGY (10 PULSES) NOMINAL VARISTOR VOLTAGE AT 10mA DC TEST CURRENT MAXIMUM STANDBY LEAKAGE (AT 13V DC) MAXIMUM CLAMPING VOLTAGE (V c ) AT TEST CURRENT (8/20 M s) V M(OC) V JUMP W L o Vn(DC) MIN V N(DC) MAX 'l Vc lp (V) (V) (J) (V) (V) (fA) (V) (A) V18AUMLA1210 16 24.5 3 23 32 50 40 1.5 V18AUMLA1812 16 24.5 6 23 32 100 40 5 V18AUMLA2220 16 24.5 25 23 32 200 40 40 NOTES: 1. Average power dissipation of transients not to exceed 0.1 5W, 0.3Wand 1Wfor model sizes 1210, 1812 and 2220 respectively. 2. Load dump energy rating (into the suppressor) of a voltage transient with a time constant of 1 1 5ms to 230ms. 3. Thermal shock capability per Mil-Std-750, Method 1 051 : -55°C to +1 25°C, 5 minutes at 25°C, 25 Cycles: 1 5 minutes at each extreme. 4. For application specific requirements, please contact Harris sales office. Power Dissipation Ratings Continuous power dissipation capability is not an applicable requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Characteristics table for the specific device. Furthermore, the operating values need to be derated at high temperatures as shown in Figure 1 . 100 90 80 70 60 50 40 30 20 10 -si* 50 60 70 80 90 100 110 120 130 140 150 = (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE 2 E Li. o £ m o 100 90 50 10 #7 ■ / T 2 ► TIME O, • VIRTUAL ORIGIN OF WAVE T = TIME FROM 10% TO 90% OF PEAK T, = VIRTUAL FRONT TIME = 1.25 x t T 2 = VIRTUAL TIME TO HALF VALUE (IMPULSE DURATION) EXAMPLE: FOR AN 8/20MS CURRENT WAVEFORM: 8l£S = T,= VIRTUAL FRONT TIME 20ms = T 2 = VIRTUAL TIME TO HALF VALUE FIGURE 2. PEAK PULSE CURRENT WAVEFORM EC « 5 ° < oc > o. 4-15 AUML Series Soldering Recommendations The principal techniques used for the soldering of components in surface mount technology are Infra Red (IR) Reflow, Vapour Phase Reflow and Wave Soldering. When wave soldering, the AUML suppressor is attached to the substrate by means of an adhesive. The assembly is then placed on a conveyor and run through the soldering process. With IR and Vapour Phase reflow the device is placed in a solder paste on the substrate. As the solder paste is heated it reflows, and solders the unit to the board. With the AUML suppressor, the recommended solder is a 62/36/2 (Sn/Pb/Ag) silver solder paste. While this configura- tion is best, a 60/40 (Sn/Pb) or a 63/37 (Sn/Pb) solder paste can also be used. In soldering applications, the AUML sup- pressor is held at elevated temperatures for a relatively long period of time, with the wave soldering operation the most strenuous of the processes. To avoid the possibility of gener- ating stresses due to thermal shock, a preheat stage in the soldering process is recommended, and the peak tempera- ture of the solder process should be rigidly controlled. When using a reflow process, care should be taken to ensure that the AUML chip is not subjected to a thermal gra- dient steeper than 4 degrees per second; the ideal gradient being 2 degrees per second. During the soldering process, preheating to within 100 degrees of the solders peak tem- perature is essential to minimize thermal shock. Examples of the soldering conditions for the AUML series of suppressors are given in the table below. Once the soldering process has been completed, it is still necessary to ensure that any further thermal shocks are avoided. One possible cause of thermal shock is hot printed circuit boards being removed from the solder process and subjected to cleaning solvents at room temperature. The boards must be allowed to cool to less than 50 degree Cel- sius before cleaning. SOLDERING OPERATION TIME (SECONDS) PEAK TEMPERATURE (°C) IR Reflow 5-10 220 Vapour Phase Reflow 5 - 10 222 Wave Solder 3-5 260 4-16 AUML Series Recommended Pad Outline c NOTE: Avoid metal runs in this area. SYMBOL CHIP SIZE 1210 1812 2220 IN MM IN MM IN MM A 0.219 5.51 0.272 6.91 0.315 8.00 B 0.147 3.73 0.172 4.36 0.240 6.19 C 0.073 1.85 0.073 1.85 0.073 1.85 Soldering Recommendations Material - 62/36/2 Sn/Pb/Ag or equivalent Temperature - 230°C, 5 seconds max Flux - Non activated Series Dimensions CHIP SIZE 1210 1812 2220 SYMBOL IN MM IN MM IN MM D MAX 0.070 1.80 0.07 1.8 0.118 3.00 E 0.02 ±0.01 0.50 ±0.25 0.02 ±0.01 0.5 ±0.25 0.03 ±0.01 0.75 ±0.25 L 0.125 ±0.012 3.20 ±0.30 0.18 ±0.014 4.5 ±0.35 0.225 ±0.016 5.7 ±0.4 W 0.10 ±0.012 2.54 ±0.30 0.125 ±0.012 3.2 ±0.30 0.197 ±0.016 5 ±0.4 Load Dump Energy Capability A Load dump transient occurs when the alternator load in the automobile is abruptly reduced. The worst case scenario of this transient occurs when the battery is disconnected while operating at full rated load. There are a number of dif- ferent load dump specifications in existence in the automo- tive industry, with the most common one being that recommended by the Society of Automotive Engineers, specification #SAE J1113. Because of the diversity of these load dump specifications Harris defines the load dump energy capability of the AUML suppressor range as that energy dissipated by the device itself, independent of the test circuit setup. The resultant load dump energy handling capability serves as an excellent figure of merit for the AUML suppressor. Standard load dump specifications require a device capabil- ity of 10 pulses at rated energy, across a temperature range of -40°C to + 125°C. This capability requirement is well within the ratings of all of the AUML series (Figure 4). V(10mA) 30 25 UJ 20 O | 15 o > 10 5 1 2220 • 25J -1812 = 6J = M 10 11 12 123*5678 * OF LOAD DUMPS FIGURE 4. AUML LOAD DUMP PULSING OVER A TEMPERATURE RANGE OF -55°C TO +125°C 4-17 AUML Series Further testing on the AUML series has concentrated on extending the number ot load dump pulses, at rated energy, which are applied to the devices. The reliability information thus generated gives an indication of the inherent capability of these devices. To date the 121 series of device has been subjected to over 2000 pulses at its rated energy of 3 joules; the 1812 series have been pulsed over 1000 times at 6 joules and 2220 series has been pulsed at its rated energy of 25 joules over 300 times, in all cases there has been little or no change in the device characteristics (Figure 5). V(10mA) 35 2220 = 25. 1812 = 6J 1210=3J 30 i <- 200 250 300 350 1,000 # OF LOAD DUMPS FIGURE 5. REPETITIVE LOAD DUMP PULSING AT RATED ENERGY 2,000 The very high energy absorption capability of the AUML suppressor is achieved by means of a new, highly controlled manufacturing process. This new technology ensures that a large volume of suppressor material, with an interdigitated layer construction, is available for energy absorption in an extremely small package. Unlike equivalent rated silicon TVS diodes, all of the AUML device package is available to act as an effective, uniform heat sink. Hence, the peak tem- peratures generated by the load dump transient are signifi- cantly lower and evenly dissipated throughout the complete device (Figure 6). This even energy dissipation ensures that there are lower peak temperatures generated at the P-N grain boundaries of the AUML suppressor. FIRED CERAMIC DIELECTRIC METAL ELECTRODES DEPLETION REGION ' DEPLETION REGION nnnn □□□□□□u, □□□□□□□J > GRAINS FIGURE 6. INTERDIGITATED CONSTRUCTION OF AUML SUPPRESSOR J 4-18 AUML Series There are a number of different size devices available in the AUML series, each one with a load dump energy rating, which is size dependent. Experience has shown that while the effects of a load dump transient is of real concern, its frequency of occurrence is much less than those of low energy inductive spikes. Such low energy inductive spikes may be generated as a result of motors switching on and off, from ESD occurrences, fuse blowing, etc. It is essential that the suppression technology selected also has the capability to suppress such transients. Testing on the V18AUMLA2220 has shown that after being subjected to a repetitive energy pulse of 2 joules, over 6000 times, no characteristic changes have occurred (Figure 7.) 10 I V18AU MLA222 1000 2000 3000 4000 5000 6000 7000 NUMBER OF PULSES FIGURE 7. REPETITIVE ENERGY TESTING OF THE V18AUMLA2220 AT AN ENERGY LEVEL OF 2 JOULES Temperature Effects In the leakage region of the AUML suppressor, the device characteristics approaches a linear (ohmic) relationship and shows a temperature dependent affect. In this region the suppressor is in a high resistance mode (approaching 10 9 ohms) and appears as a near open-circuit. Leakage currents at maximum rated voltage are in the microamp range. With clamping transients at higher currents (at and above the ten milliamp range), the AUML suppressor approaches a 1-1 Ofi characteristic. In this region the characteristics of the AUML are virtually temperature independent. Figure 8 shows the typical effect of temperature on the V-l characteristics of the AUML suppressor. 1(iA 10(iA 100(jA 1mA 10mA 100mA 1A 10A 100A 1000A CURRENT FIGURE 8. TYPICAL V-l CHARACTERISTICS OF THE V18AUMLA2220 at -40°C, +25°C, +85°C AND +125°C Speed of Response The clamping action of the AUML suppressor depends on a conduction mechanism similar to that of other semiconduc- tor devices (i.e. P-N Junctions). The apparent slow response time often associated with transient voltage suppressors (Zeners, MOVs) is often due to parasitic inductance in the package and leads of the device and is independent of the basic material (silicon, zinc oxide). Thus, the single most crit- ical element affecting the response time of any suppressor is its lead length and, hence, the inductance in the leads. The AUML suppressor is a pure surface mount device, with no leads or external packaging, and thus, it has virtually zero inductance. The actual response time of a AUML surge sup- pressor is in the 1 to 5 nanosecond range and this response time is more than sufficient for the transients which are likely to be encountered in an automotive environment. 4-19 AUML Series Tape and Reel Specifications • Conforms to EIA - 481, Revision A • Can be Supplied to IEC Publication 286 - 3 -Hk TAPE 8mm WIDE TAPE 12mm WIDE TAPE Chip Size 1210 1812 2220 Quantity Per 178mm Reel 2000 1000 1000 Quantity Per 330mm Reel 8000 4000 4000 K -.|^ ,J D °I, r I f-V/ 4 f£>| € — — - H /+n/ e 1 D, Pi Ao SYMBOL DESCRIPTION TAPE WIDTH 8mm 12mm Ao Width of Cavity Dependent on Chip Size to Minimize Rotation. Bo Length of Cavity Dependent on Chip Size to Minimize Rotation. Ko Depth of Cavity Dependent on Chip Size to Minimize Rotation. W Width of Tape 8 ±0.2 12 ±0.2 F Distance Between Drive Hole Centers and Cavity Centers 3.5 ±0.5 5.4 ±0.5 E Distance Between Drive Hole Centers and Tape Edge 1.75 ±0.1 Pi Distance Between Cavity Center 4 ±0.1 8 ±0.1 P 2 Axial Distance Between Drive Hole Centers and Cavity Centers 2±0.1 Po Axial Distance Between Drive Hole Centers 8 ±0.1 Do Drive Hole Diameter 1.55 ±0.05 □i Diameter of Cavity Piercing 1.05 ±0.05 1.55 ±0.05 '1 Embossed Tape Thickness 0.3 max 0.4 max t 2 Top Tape Thickness 0.1 max NOTE: Dimensions in millimeters. Standard Packaging Tape and reel is the standard packaging method of the AUML series. The standard 330 millimeter (13 inch) reel uti- lized contains 4000 pieces for the 2220 and 1812 chips, and 8000 pieces for the 1210 chip. To order add T23" to the standard part number, e.g. V18AUMLA2220T23. Special Packaging Option 1: 178 millimeter (7 inch) reels containing 1000 (2220, 1 81 2) or 2000 (121 0), pieces are available. To order add "H23" to the standard part number, e.g. V18AUMLA2220H23. Option 2: For small sample quantities (less than 100 pieces) the units are shipped bulk pack. To order add "A23" to the standard part number, e.g. V18AUMLA2220A23. IDENTIFYING OR 330MM 4-20 AUML Series Part Nomenclature The part numbering system of the AUML surge suppressor series gives the following information: e.g. Part Number: V18AUMLA2220T23 V = Harris Transient Voltage Suppressor 18 = Recognized Automotive Suppressor Rating AUML = Automotive Series A = Load Dump Energy Indicator 2220 (or 1812 or 1210) = Device Size T23 (or H23 or A23) = Quantity Designator Description of AUML Ratings and Characteristics Maximum Continuous OC Working Voltage (V M(DC) ) This is the maximum continuous DC voltage which may be applied, up to the maximum operating temperature (+125°C), to the ML suppressor. This voltage is used as the reference test point for leakage current and is always less than the breakdown voltage of the device. under load Load Dump Energy Rating This is the actual energy the part can dump conditions. Maximum Clamping Voltage (V c ) This is the peak voltage appearing across the suppressor when measured at conditions of specified pulse current and specified waveform (8/20us). It is important to note that the peak current and peak voltage may not necessarily be coin- cidental in time. Leakage Current (l L ) In the nonconducting mode, the device is at a very high impedance (approaching 10 9 Q) and appears as an almost open circuit in the system. The leakage current drawn at this level is very low (<50uA at ambient temperature) and, unlike the zener diode, the multilayer TVS has the added advan- tage that, when operated up to its maximum temperature, its leakage current will not increase above 500uA. Nominal Voltage (V N(DC) ) This is the voltage at which the AUML enters its conduction state and begins to suppress transients. In the automotive environment this voltage is defined at the 10 milliamp point and has a minimum (V N(DC) M , N ) and maximum (V N(DC) MAX ) voltage specified. 4-21 UU S E II March 1995 BA/BB Series CONDUCTOR Industrial High Energy Metal-Oxide Varistors BA Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 to Std. 1449 • High Energy Absorption Capability W TM BA Series 3200J BB Series 10.000J • Wide Operating Voltage Range V M(AC)RMS BA Series 130V to 880V BB Series 11 00V to 2800V • Rigid Terminals for Secure Wire Contact • Case Design Provides Complete Electrical Isolation of Disc SubAssembly • Large Diameter Disc 60mm Description BA and BB series transient surge suppressors are heavy- duty industrial metal-oxide varistors designed to provide surge protection for motor controls and power supplies used in oil-drilling, mining, and transportation equipment. Possible voltage surges in their AC power supplies could cause product failure and the subsequent faulty operation of these systems. These UL-recognized varistors have similar package construction but differ in size, ratings and electrical characteristics. Both the BA and BB series feature improved creep and strike capability to minimize breakdown along the package surface, a package design that provides complete electrical isolation of the disc subassembly, and rigid terminals to insure secure wire contacts. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Characteristics chart BA SERIES Continuous: Steady State Applied Voltage: AC Voltage Range ( V M(AC1RMS ) 1 30 to 880 DC Voltage Range (V M(DC) ) 1 75 to 1 1 50 Transient: Peak Pulse Current (l TM ) For 8/20ns Current Wave (See Figure 2) 50,000 to 70,000 Single Pulse Energy Range For 1 0/1 000ns Current Wave (W TM ) 450 to 3200 Operating Ambient Temperature Range (T A ) -55 to +85 Storage Temperature Range (T STG ) -55 to +125 Temperature Coefficient (otV) of Clamping Voltage (V c ) at Specified Test Current <0.01 Hi-Pot Encapsulation (Isolation Voltage Capability) 5000 (Dielectric must withstand indicated dc voltage for one minute per MIL-STD 202, Method 301) Insulation Resistance 1000 BB SERIES 11 00 to 2800 1400 to 3500 70,000 3800 to 10,000 -55 to +85 -55 to +125 <0.01 5000 1000 UNITS J °C °c %/°c V MQ Copyright © Harris Corporation 1995 4-22 File Number 2183.3 Specifications BA/BB Series Device Ratings and Characteristics Series BA and BB Varistors are listed under UL file #E75961 as a UL recognized component. MAXIMUM RATINGS (+85°C) CHARACTERISTICS (+25°C) CONTINUOUS TRANSIENT MAX CLAMPING TYPICAL V RMS Vdc ENERGY (2ms) PEAK CUR- RENT (8/20ns) VARISTOR VOLTAGE AT 1mA DC TEST CURRENT VOLT V c AT 200A CURRENT (8/20us) CAPACI- TANCE MODEL V M(AC) V M(DC) W TM Itm MIN Vn(dc) MAX Vc f = 1MHz NUMBER (V) (V) (J) (A) fVI (V) (pF) V131BA60 130 175 450 50000 1 84 200 228 340 20000 V151BA60 150 200 530 50000 212 240 268 400 16000 V251BA60 250 330 880 50000 354 390 429 620 10000 V271 BA60 275 369 950 50000 389 430 473 680 9000 V321 BA60 320 420 1100 50000 462 510 539 760 7500 V421 BA60 420 560 1500 70000 610 680 748 1060 6000 V481BA60 480 640 1600 70000 670 750 825 1160 5500 V511BA60 510 675 1800 70000 735 820 910 1300 5000 V571BA60 575 730 2100 70000 805 910 1000 1420 4500 V661BA60 660 850 2300 70000 940 1050 1160 1640 4000 V751BA60 750 970 2600 70000 1080 1200 1320 1880 3500 V88lt3A60 880 1150 3200 70000 1290 1500 1650 2340 2700 V112BB60 1100 1400 3800 70000 1620 1800 2060 2940 2200 V142BB60 1400 1750 5000 70000 2020 2200 2550 3600 1800 V172BB60 1700 2150 6000 70000 2500 2700 3030 4300 1500 V202BB60 2000 2500 7500 70000 2970 3300 3630 5200 1200 V242BB60 2400 3000 8600 70000 3510 3900 4290 6200 1000 V282BB60 2800 3500 10000 70000 4230 4700 5170 7400 800 NOTE: Average power dissipation of transients not to exceed ; 0C £ 5 ° > 0- Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Characteristics table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. 140 150 70 80 90 100 110 120 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE O, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8fis = T, = Virtual Front Time 20ps = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM 4-23 BA/BB Series 1 i (A DC (A u. 5 o a ui 1.0 0.8 0.6 0.4 0.1 0.08 0.06 0.04 TYPICAL TEMPERATURE COEFFICIENT OF POWER DISSIPATION = 2.2%/°C : MAX AT T A = +85°C z MAX AT T A = +25°C . — TYP AT T A = +25°C 80 90 100 PERCENTAGE OF MAXIMUM RATED V n >(%> FIGURE 3. STANDBY POWER DISSIPATION vs APPLIED V RMS AT VARIED TEMPERATURES z > 0.3 25 Ui cc Cfl u. 5 O DC m S o 1,000 HOURS, T A = +85°C 10 100 TIME AT RATED V RMS (HOURS) FIGURE 4. TYPICAL STABILITY OF STANDBY POWER DISSI- PATION AT RATED V RMS vs TIME Transient V-l Characteristics Curves 10° 10' 10' 10 J PEAK AMPERES (A) FIGURE 5. CLAMPING VOLTAGE FOR V131BA60 - V881 BA60 20,000 - MAX CLAMPING VOLTAGE DISC SIZE 60mm 1100 TO 2800V M(AC) RATING T» = -55°C TO +85°C 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 6. CLAMPING VOLTAGE FOR V1 1 2BB60 - V282BB60 Pulse Rating Curves IMPULSE DURATION (us) FIGURE 7. SURGE CURRENT RATING CURVES FOR V131BA60-V3210A60 IMPULSE DURATION (ps) FIGURE 8. SURGE CURRENT RATING CURVES FOR V421BA60-V282BB60 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±1 0% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-24 BA/BB Series Package Outline Dimensions BA SERIES IX D M) 40.0 11.575) M« INTERNATIONAL THREAD PAN HEAD SLOTTED 9 40.0(1 575) , M6 INTERNATIONAL THREAD PAN HEAD SLOTTED SCREW 7.0 [ 0,25) - 23.5 10.925) M.O {3.38) 7.0 1 : (0 21), «- 1 NOTES: 1. Typical Weight: BA BB 250g 600g Dimensions are in mm; inches in parentheses for reference only. 2B*- yL_i 100.0 (3.» 4) 10.5 (0.41) 10.5 (0.41 ) 44.5 (1 752) 401 2 (1.57510.06) H6 KTEANaTIONAL • 5 (3.74) 4-25 66 SEMICONDUCTOR June1995 C" /// Series Radial Lead Metal-Oxide Varistors "C" III Features • Recognized as "Transient Voltage Surge Suppressors" to UL 1449; File # E75961 • Recognized as "Transient Voltage Surge Suppressors" to CSA C22.2, No. 1; File #LR91 788 • High Energy Absorption Capability W TM 45J to 210 J (2ms) • High Peak Pulse Current Capability l TM 6000A to 9000A (8/20>s) • Wide Operating Voltage Range V M(AC)RMS 130V to 320V • Available in Tape and Reel for Automatic Insertion; Also Available with Crimped and/or Trimmed Lead Styles Description The expanded version of the LA series of metal-oxide varis- tors, designation "C" III series, consists of AC line voltage rated MOVs with extremely high current and energy han- dling capabilities. This new "C" III series of MOVs was pri- marily designed for the transient voltage surge suppressor (TVSS) environment. They provide the increased level of protection now deemed to be necessary for the transients expected in this environment. The occurrence of high volt- age transients in the AC power network can be detrimental to the associated line equipment. Such transient occur- rences may cause product failure and the subsequent faulty operation of the electrical systems. This special version of the Harris 14mm and 20mm LA series of metal oxide varis- tors is also available with 10mm lead spacing, tape and reel, and in a variety of crimped and trimmed lead forms. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart "C" III SERIES UNITS Continuous: Steady State AC Voltage Range (V M(AC)HMS ) 130 to 320 V Transients: Single-Pulse Peak Current (l TM ) 8/20p.s Wave (See Figure 2) 6000 to 9000 A Single-Pulse Energy Range (W TM ) 2ms Rectangular Wave 45 to 210 J Maximum Temporary Overvoltage of V M(AC) , (5 Minutes Duration) 130 (+25°C) % 120 (+125°C) % Operating Ambient Temperature Range (T A ) -55 to +85 °C Storage Temperature Range (T STG ) -55 to +125 °C Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Copyright © Harris Corporation 1995 4-26 File Number 3540.3 Specifications "C" III Series "C" III Series Ratings MAXIMUM RATINGS (+85°C) CONTINUOUS TRANSIENT MAXIMUM V RMS WITHSTANDING PEAK CURRENT (8/20us ) ENERGY (2ms) MODEL DEVICE V M(AC) W TM (J-L) l TM1 1 PULSE l™ 2 2 PULSES NUMBER MARKING (V) (J) (A) (A) V130LA10C 130L10C 130 45 6000 5000 V1 30LA20C 130L20C 130 90 9000 7000 V130LA20CX325 130LA20CX325 130 90 9000 7000 V140LA10C 140L10C 140 50 6000 5000 V140LA20C 140L20C 140 100 9000 7000 V140LA20CX340 140L20CX340 140 100 9000 7000 V150LA10C 150L10C 150 55 Rnnn DUUU 5000 V150LA20C 150L20C 150 110 9000 7000 V150LA20CX360 150L20CX360 150 110 9000 7000 V175LA10C 175L10C 175 60 6000 5000 V175LA20C 175L20C 175 120 9000 7000 V175LA20CX425 175L20CX425 175 120 9000 7000 V230LA20C 230L20C 230 80 6000 5000 V230LA40C 230L40C 230 160 9000 7000 V230LA40CX570 230L40X570 230 160 9000 7000 V250LA20C 250L20C 250 100 6000 5000 V250LA40C 250L40C 250 170 9000 7000 V250LA40CX620 250L40CX620 250 170 9000 7000 V275LA20C 275L20C 275 110 6000 5000 V275LA40C 275L40C 275 190 9000 7000 V275LA40CX680 275L40CX680 275 190 9000 7000 V300LA20C 300L20C 300 120 6000 5000 V300LA40C 300L40C 300 210 9000 7000 V300LA40CX745 300L40CX745 300 210 9000 7000 V320LA20C 320L20C 320 200 6000 5000 V320LA40C 320L40C 320 200 9000 7000 2p > D. "C" III Series Specifications SPECIFICATIONS (+25°C) MAXIMUM CLAMPING VARISTOR VOLTAGE AT VOLTAGE DUTY CYCLE SURGE MODEL SIZE 1mA DC TEST CURRENT (8/20)18) RATING DISC 3kA 750A MODEL DIAMETER V N MIN V N MAX Vc 'p (8/20us) (8/20US) NUMBER (mm) (V) (V) (V) (A) # PULSES # PULSES V130LA10C 14 184 228 340 50 10 80 V130LA20C 20 184 228 340 100 20 120 V130LA20CX325 20 184 220 325 100 20 120 V140LA10C 14 198 242 360 50 10 80 V140LA20C 20 198 242 360 100 20 120 V140LA20CX340 20 198 230 340 100 20 120 V150LA10C 14 212 268 395 50 10 80 V150LA20C 20 212 268 395 100 20 120 V150LA20CX360 20 212 243 360 100 20 120 V175LA10C 14 247 303 455 50 10 80 V175LA20C 20 247 303 455 100 20 120 V175LA20CX425 20 247 285 425 100 20 120 4-27 "C" III Series "C" III Series Specifications (Continued) SPECIFICATIONS (+25°C) MAXIMUM CLAMPING VARISTOR VOLTAGE AT VOLTAGE DUTY CYCLE SURGE MODEL SIZE 1mA DC TEST CURRENT (8/20u»> RATING DISC 3kA 750A MODEL DIAMETER V N MIN V N MAX Vc P (8/20us) (8/20us) KM IIIDCD (mm) (V) (V) (V) (A) # PULSES # PULSES V230LA20C 14 324 396 595 50 10 80 V230LA40C 20 324 396 595 100 20 120 V230LA40GX57U 20 324 384 570 100 20 120 V250LA20C 14 354 429 650 50 10 80 V250LA40C 20 354 429 650 100 20 120 V250LA40CX620 20 354 413 620 100 20 120 V275LA20C 14 389 473 710 50 10 80 V275LA40C 20 389 473 710 100 20 120 V275LA40CX680 20 389 453 680 100 20 120 V300LA20C 14 420 517 775 50 10 80 V300LA40C 20 420 517 775 100 20 120 V300LA40CX745 20 420 490 745 100 20 120 V320LA20C 14 462 565 850 50 10 80 V320LA40C 20 462 565 850 100 20 120 NOTE: Average power dissipation of transients not to exceed 0.6W and 1 W for model sizes 14mm and 20mm, respectively Power Dissipation Ratings The metal oxide varistor is designed to absorb voltage transients of relatively short durations, not continuous over voltage. Therefore, unless transients occur in rapid succession, a continuous power dissipation capability is not an applicable design requirement for a varistor. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. The operating values of a MOV need to be derated at high temperatures as shown in Figure 1. Because varistors only dissipate a relatively small amount of average power they are not suitable for repetitive applications that involve substantial amounts of average power dissipation. 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE 4-28 "C" III Series Transient V-l Characteristics Curves 2,000 — ■ 2 10 3 10* PEAK AMPERES (A) FIGURE 3. MAXIMUM CLAMPING VOLTAGE FOR V130LA10C TO V320LA20C 2,000 1,000 10'' 10° 10 1 10* PEAK AMPERES (A) FIGURE 4. MAXIMUM CLAMPING VOLTAGE FOR V130LA20C TO V320LA40C 3 1,000 9o 5 ° < DC > 0. 100 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 5. MAXIMUM CLAMPING VOLTAGE FOR V130LA20CX325 TO V300LACX745 Rating Curves 1,000 100 1,000 10,000 SURGE IMPULSE DURATION (us) FIGURE 6. REPETITIVE SURGE CAPABILITY FOR V130LA10C TO V320LA20C 100 1,000 10,000 SURGE IMPULSE DURATION (us) FIGURE 7. REPETITIVE SURGE CAPABILITY FOR V130LA20C TO V320LA40C 4-29 "C" III Series Tape and Reel Specification 1 L Tape and Reel Data • Conforms to ANSI and EIA Specifications • Can be supplied to IEC publication 286-2 • Radial devices on tape and reel are supplied with either crimped leads, straight leads, or under-crimped leads. Tape and Reel Ordering Information • Crimped leads are standard on LA types supplied in tape and reel and are denoted by the model letter "T". Also, in tape and reel, model letter "S" denotes straight leads and letter "U" denotes special under-crimped leads. Example: P, 1— i -J F L~^"^*D„ I— J — MODEL SIZE SYMBOL DESCRIPTION 14mm 20mm P Pitch of Component 25.4 ± 1.0 Po Feed Hole Pitch 12.7±0.2 Pi Feed Hole Center to Pitch 2.60 ±0.7 P 2 Hole Center to Component Center 6.35 ±1.0 F Lead to Lead Distance 7.50 ±0.8 h Component Alignment 2.00 Max W Tape Width 18.25 ±0.75 W Hold Down Tape Width 6.00 ± 0.3 12.0± 0.3 W, Hole Position 9.125 ±0.625 w 2 Hold Down Tape Position 0.5 Max H Height From Tape Center To Component Base 19.0 ± 1.0 Ho Seating Plane Height 16.0±0.5 Hi Component Height 40 Max 46.5 Max Do Feed Hole Diameter 4.0 ±0.2 t Total Tape Thickness 0.7 ±0.2 L Length of Clipped Lead 12.0 Max P Component Alignment 3° Max STANDARD MODEL CRIMPED LEADS STRAIGHT LEADS UNDER CRIMP LEADS V130LA20C V130LT20C V130LS20C V130LU20C Shipping Quantity DEVICE SIZE QU "T" REEL ANTITY PER RE "S" REEL EL "U" REEL 14mm 500 500 500 20mm 500 500 500 Package Outline Dimensions SYMBOL VARISTOR MODEL SIZE 14mm 20mm MIN MAX MIN MAX A 13.5 (0.531) 20 (0.787) 17.5 (0.689) 26.5 (1.043) 0D 13.5 (0.531) 17 (0.669) 17.5 (0.689) 23 (0.906) e 6.5 (0.256) 8.5 (0.335) 6.5 (0.256) 8.5 (0.335) e1 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) E 5.6 (0.220) 5.6 (0.220) 0b 0.76 (0.030) 0.86 (0.034) 0.76 (0.030) 0.86 (0.034) Dimensions are in millimeters (inches) NOTE: 10mm lead spacing also available. See additional lead style options. 4-30 "C" III Series Additional Lead Style Options Radial lead types can be supplied with combination pre- formed crimp and trimmed leads. This option is supplied to the dimensions shown below. SYMBOL VARISTOR MODEL SIZE 14mm 20mm MIN MAX MIN MAX A 24.5 (0.96) 31 (1.22) L TRIM 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) NOTE: Dimensions are in millimeters (inches) 'Seating plane interpretation per IEC-717 • To order this crimped and trimmed lead style, the standard radial type model number "LA" is changed to the model number "LC". This option is supplied in bulk only. Example: STANDARD MODEL ORDER AS V130LA20C V130LC20C • For 10 ± 1mm lead spacing on 20mm units only; append standard model numbers by adding "X10" suffix. Example: STANDARD MODEL ORDER AS V130LA20C V130LA20CX10 For other lead style variations to the above, please contact Harris Semiconductor Power Marketing The Origins of Surge Overvoltages There are a wide variety of transient overvoltage environments, each with radically different levels of exposure. Transients may be caused by lightning, which can inject very high currents into the electrical system, or by switching transients. Lightning strikes usually occur to the primary transmission lines with resulting coupling to the secondary line through mutual inductive or capacitive coupling. Even a lightning hit that misses the primary AC line can induce substantial voltage onto the primary conductors, triggering lightning arresters and thus creating transients. Switching transients, while of a lower magnitude than light- ning, occur more frequently and thus are of a greater threat to the AC system. Switching transients may result from fuse blowing, capacitor bank switching, fault clearing or grid switching. Field studies and laboratory investigation of residential and industrial low power AC voltage systems have shown that the amplitude of a transient is proportional to the rate of its occurrence, i.e. lower magnitude transients occur most often. Governing bodies, in particular IEC, UL, IEEE and ANSI have established guidelines on the transient environment one may expect to encounter in a low voltage AC power system. Table 1 reflects the surge voltages and currents deemed to represent the indoor environment. LOCATION CATEGORY TRANSIENT WAVEFORM/ MAGNITUDE A Long Branch Circuits and Outlets 0.5ms 100kHz 6kV 200A B Major Feeders and Short Branch Circuits 1.2/50(is 8/20ns 6kV 3kA 0.5(is 100kHz 6kV 500A 4-31 "C" III Series "C" III MOV Series The new "C" III series of Harris radial MOVs represent the third generation of improvements in device performance and characteristics. The technology effort involved in the devel- opment of this new series concentrated on extending the existing performance and capability of the Harris second generation of metal oxide varistors. The characteristics of greatest importance for a metal oxide varistor in an AC surge environment are the peak current, energy handling, repetitive surge and temporary over-volt- age capabilities. The focus of the design effort was on improving these characteristics and therefore offering the maximum protection presently available to the end user. The new "C" III series are designed to survive the harsh environments of the AC low-power indoor environment. Their much improved surge withstand capability is well in excess of the transients expected in the AC mains environ- ment. Further design rules for the development of the "C" III series included considerations of the expected steady state operating conditions and the repetitive surge environment. Investigation of the AC low-power indoor environment show that most transients occur where the power enters the build- ing and at major feeders and short branch circuits. Surges recorded at this service entrance, location Category B from C62.41-1992, may be both oscillatory and unidirectional in nature. The typical "lightning surge" has been established as a 1 .2/50us voltage wave and a 8/20ns current wave. A short circuit current of 3000A and open circuit voltage 6000V are the expected worst case transients at this location. TEST REFERENCE STANDARD TEST CONDITIONS TEST RESULTS Surge Current UL 1449 IEEE/ANSI C62.41 9000A (8/20|ls) 1 Pulse 0/165 IEC 1051 7000A (8/20(is) 2 Pulses 0/105 3000A (8/20(is) 20 Pulses 0/75 750A (8/20|is) 120 Pulses 0/65 Surge Energy UL 1449 IEEE/ANSI C62.41 IEC 1051 90J (2ms) 1 Pulse 0/125 Operating Life Mil-Std-202 Method 204D 125°C, 1000 Hours, Rated Bias Voltage 0/180 Temporary Overvoltage N/A 120% Maxi- mum Rated Varistor Voltage For 5 minutes 0/70 The further into the facility one goes, the lower the magni- tude of the transients encountered. ANSI/IEEE C62.41 dif- ferentiates between the service entrance and the interior of a facility. Per this specification, the internal location or long branch circuits and outlets are classified as Location Cate- gory A. The transients encountered here have oscillatory waveshapes with frequency ranges from 5kHz to 500kHz; with 100kHz deemed most common. Transients of the mag- nitude of 500A are expected in this location. Reliability Performance of "C" III Series The electrical ratings of the "C" III series of MOVs are con- servatively stated. Samples of these devices have been tested under additional stresses, over and above those called out in the datasheet. The results of this testing show an enhanced device performance. The series of stress tests to which the units were subjected are a combination of electrical, environmental and mechani- cal tests. A summary of the reliability tests performed on the "C" III series are described in Table 2 AC Bias Reliability The "C" III series of metal oxide varistors was designed for use on the AC line. The varistor is connected across the AC line and is biased with a constant amplitude sinusoidal volt- age. It should be noted that the definition of failure is a shift in the nominal varistor voltage (V N ) exceeding + 10%. Although this type of varistor is still functioning normally after this magnitude of shift, devices at the lower extremities of V N tolerance will begin to dissipate more power. Because of this possibility, an extensive series of statistically designed tests were performed to determine the reliability of the "C" III type of varistor under AC bias combined with high levels of temperature stress. To date, this test has generated over 50,000 device hours of operation at a temperature of +125°C, although only rated at +85°C. Changes in the nomi- nal varistor voltage, measured at 1 mA, of less than 2% have been recorded (Figure 8). Transient Surge Current/Energy Capability The transient surge rating serves as an excellent figure of merit for the "C" III suppressor. This inherent surge handling capability is one of the new "C" III suppressor's best fea- tures. The enhanced surge absorption capability results from improved process uniformity and enhanced construction. The homogeneity of the raw material powder and improved control over the sintering and assembly processes are con- tributing factors to this improvement. In the low power AC mains environment, industry governing bodies (UL, IEC, NEMA and IEEE) all suggest that the worst case surge occurrence will be 3kA. Such a transient event may occur up to five times over the equipment life time (approximately 10 years). While the occurrences of five 3 4-32 "C" III Series kiloamps transients is the required capability, the conserva- tively rated, repetitive surge current for the "C" III series is 20 pulses for the 20mm units and 10 pulses for the 14mm series. As a measure of the inherent device capability, samples of the 20mm V130LA20C devices were subjected to a worst case repetitive transient surges test. After 100 pulses, each of 3kA, there was negligible change in the device character- istics. Changes in the clamping voltage, measured at 100 amps, of less than 3% were recorded (Figure 9). Samples of the 14mm Series V175LA20C were subjected to repetitive surge occurrences of 750A. Again, there was negligible changes in any of the device characteristics after 250 pulses (Figure 10). In both cases the inherent device capability is far in excess of the expected worst case scenario. 150 V1 ■■■"1 30LA r 100 200 300 400 500 600 700 TIME (HOURS) 800 900 1000 1100 FIGURE 8. HIGH TEMPERATURE OPERATING LIFE 125°C FOR 1000 HOURS AT RATED BIAS Terms and Descriptions Rated AC Voltage (V M(AC)RHS ) This is the maximum continuous sinusoidal voltage which may be applied to the MOV. This voltage may be applied at any temperature up to the maximum operating temperature of +85°C. Maximum Non-Repetitive Surge Current (l TM ) This is the maximum peak current which may be applied for an 8/20us impulse, with rated line voltage also applied, with- out causing device failure. (See Figure 2) Maximum Non-Repetitive Surge Energy (W TM ) This is the maximum rated transient energy which may be dissipated for a single current pulse at a specified impulse and duration (2ms), with the rated V RMS applied, without causing device failure. Nominal Voltage (V N(DC) ) This is the voltage at which the device changes from the off state to the on state and enters its conduction mode of oper- ation. This voltage is characterized at the 1 mA point and has specified minimum and maximum voltage levels. Clamping Voltage (V c ) This is the peak voltage appearing across the MOV when measured at conditions of specified pulse current amplitude and specified waveform (8/20us) 5 lu 450 O 400 a 300 vi: 3kf ola: (8/2 oc ) M S) (FU I TED I FOR I I 20 SI I I RGE I 5) I 10 20 30 40 50 60 70 80 90 100 110 120 NUMBER OF SURGES FIGURE 9. TYPICAL REPETITIVE SURGE CURRENT CAPA- BILITY OF "C" III SERIES MOVs 0C £ 2o 5 2 > 0- g 600 H 550 300 (RATED FOR 80 SURGES) 1 I V175LA20C 750A (8/20ns) 50 300 100 150 200 2S NUMBER OF SURGES FIGURE 10. TYPICAL REPETITIVE SURGE CURRENT CAPA- BILITY OF "C" III SERIES MOVs 4-33 jsj harris CA Series W SEMICONDUCTOR V//l ■ f ^7 Industrial High Energy Metal-Oxide March 1995 Disc Varistors Feafures • Provided Unpackaged For Unique Packaging By Customer • Solderable Electrode Finish Also Provides Pressure Contacts for Stacking Applications • Available Disc Sizes 32mm, 40mm, and 60mm Diameter • Wide Operating Voltage Range V M(AC)RMS 130V to 2800V • Wide Peak Pulse Current Range l TM 20.000A to 70.000A • Very High Energy Capability W TM 200J to 10.000J Description three diameter sizes: 32, 40, and 60mm, with disc thick- nesses ranging from 1.8mm minimum to 32mm maximum. They offer a wide voltage range of from 130 to 2800 V M(AC)RMS. For information on mounting considerations refer to Applica- tions Brief AB-8820. Absolute Maximum Ratings For ratings of individual members of a series, see Device Re tings and Specifications chart CA SERIES UNITS Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 130 to 2800 V DC Voltage Range (V M(DC) ) i 175 to 3500 V Transient: Peak Pulse Current (l TM ) For 8/20ms Current Wave (See Figure 2) 20,000 to 70,000 A Single Pulse Energy Range 200 to 10,000 J -55 to +85 °C -55 to +125 °C Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Copyright © Harris Corporation 1 995 p|| e fg umDer 21 87.3 4-34 CA series transient surge suppressors are industrial high- energy disc varistors intended for special applications requir- ing unique contact or packaging considerations. The elec- trode finish of these devices is solderable and can also be used as pressure contacts for stacking applications. These CA series industrial disc varistors are available in Specifications CA Series Device Ratings and Specifications MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+2S°C) CONTINUOUS TRANSIENT MAX CLAMPING VOLT V c PEAK AT 200A TYPICAL ENERGY CURRENT VARISTOR VOLTAGE AT CURRENT CAPACI- V RMS Vdc (2ms) (8/20.LS) 1mA DC TEST CURRENT (8/20ps) TANCE MODEL SIZE Vm(AC) Vm(DC) w,„ "TM "TM MIN V N(DC) MAX Vc f = 1MHz NUMBER (mm) \* 1 IV* ijl K"! /Al (V) (V) (V) (V) (pF) V131CA32 32 130 175 200 20000 184 200 228 350 4700 V131CA40 40 270 30000 345 10000 V151CA32 32 150 200 220 20000 — rrr — 212 TTT 240 T-T 268 410 4000 V151CA40 40 300 30000 405 8000 32 250 330 330 20000 354 390 TT 429 680 2500 V251CA40 40 370 30000 650 5000 V251CA60 60 880 50000 620 1 0000 V971 CAV V £ / I V> rAO£- 32 275 369 360 20000 389 430 473 750 2200 V271 CA40 40 400 30000 730 4500 V271CA60 60 950 50000 680 9000 Vot I wnOt 32 320 420 390 20000 462 510 539 850 1900 V321CA40 40 460 30000 830 3800 V321CA60 60 1100 50000 760 7500 1 P A99 32 420 560 400 25000 610 680 748 1200 1500 V421CA40 40 600 40000 1130 3000 V421 CA60 60 1500 70000 1 060 6000 \MP1 f A?? V to 1 unot 32 480 640 450 25000 670 750 825 1300 1300 V481CA40 40 650 40000 1240 2700 V481CA60 60 1600 70000 1 160 5500 VO 1 1 Urtot 32 510 675 500 25000 735 820 910 1440 1200 VS1 1OA40 v *j i i vn*iy 40 700 40000 1350 2500 V51 1CA60 60 1 800 70000 1300 5000 ^71 C A^P 32 575 730 550 25000 one; QUO Q1 n y i u 1 000 1 600 1 100 V571CA40 40 770 40000 oonn V571CA60 60 2100 70000 1 420 **ouu V661CA32 32 660 850 600 25000 940 1050 1160 1820 1000 V661CA40 40 900 40000 1720 2000 V661CA60 60 2300 70000 1640 4000 V751CA32 32 750 970 700 25000 1080 1200 1320 2050 800 V751CA40 40 1050 40000 2000 1800 V751CA60 60 2600 70000 1880 3500 V881CA60 60 880 1150 3200 70000 1290 1500 1650 2340 2700 V112CA60 60 1100 1400 3200 70000 1620 1800 2060 2940 2200 V142CA60 60 1400 1750 5000 70000 2020 2200 2550 3600 1800 V172CA60 60 1700 2150 6000 70000 2500 2700 3030 4300 1500 V202CA60 60 2000 2500 7500 70000 2970 3300 3630 5200 1200 V242CA60 60 2400 3000 8600 70000 3510 3900 4290 6200 1000 V282CA60 60 2800 3500 10000 70000 4230 4700 5170 7400 800 NOTE: Average power dissipation of transients not exceed 1.5W, 2.0W and 2.5W for model 32mm, 40mm and 60mm, respectively. Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be derated at high temperatures as shown in Figure 1 . Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. 4-35 CA Series 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE O, m Virtual Origin of Wave T = Time From 1 0% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ps Current Waveform: 8us = T-i = Virtual Front Time 20ps = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves 10° 10 1 10 2 PEAK AMPERES FIGURE 3. CLAMPING VOLTAGE FOR V131CA32 - C751CA32 10' PEAK AMPERES FIGURE 4. CLAMPING VOLTAGE FOR V131CA40 - V751CA40 4-36 CA Series Pulse Rating Curves 100 1,000 IMPULSE DURATION ((is) FIGURE 7. SURGE CURRENT RATING CURVES FOR V131CA32-V321CA32 100 1,000 IMPULSE DURATION (us) FIGURE 8. SURGE CURRENT RATING CURVES FOR V421CA32-V751CA32 10,000 100 1,000 IMPULSE DURATION (us) FIGURE 9. SURGE CURRENT RATING CURVES FOR V131CA40-V321CA40 DISC SIZE 40mm V421CA40- V751CA40- 100 1,000 IMPULSE DURATION (us) FIGURE 10. SURGE CURRENT RATING CURVES FOR V421CA40-V7S1CA40 100 1,000 IMPULSE DURATION (us) FIGURE 11. SURGE CURRENT RATING CURVES FOR V251CA60-V321CA60 100 1,000 IMPULSE DURATION (us) FIGURE 12. SURGE CURRENT RATING CURVES FOR V421CA60- V282CA60 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±10% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but does not prevent the device from continuing to function, and to provide ample protection. 4-37 CA Series VrmS V M(AC) THICKNESS (32mm DISC) THICKNESS (40mm AND 60mm DISC) MILLIMETERS INCHES MILLIMETERS INCHES MIN MAX MIN MAX MIN MAX MIN MAX 130f 1.8 2.4 0.071 0.094 2.5 3.4 0.098 0.134 150t 2.1 2.8 0.083 0.1 10 2.8 3.8 0.110 0.150 250 1.6 2.2 0.063 0.087 2.0 2.7 0.079 0.106 275 1.8 2.5 0.071 0.098 2.2 3.0 0.087 0.118 320 2.1 2.9 0.083 0.114 2.6 3.5 0.102 0.138 420 2.9 3.9 0.114 0.154 3.5 4.7 0.138 0.185 480 3.1 4.3 0.122 0.169 3.8 5.2 0.150 0.205 510 3.5 4.7 0.138 0.185 4.2 5.7 0.165 0.224 575 3.8 5.1 0.150 0.201 4.6 6.3 0.181 0.248 660 4.4 6.0 0.173 0.236 5.3 7.2 0.209 0.283 750 5.1 6.9 0.240 0.327 6.1 8.3 0.240 0.327 880 ft 7.3 10.3 0.287 0.406 1100ft 9.2 13.0 0.362 0.512 1400ft 11.5 16.0 0.453 0.630 1700ft 14.0 19.0 0.551 0.748 2000ft 17.0 22.5 0.669 0.886 2400tt 20.0 27.0 0.787 1.063 2800ft 24.0 32.0 0.945 1.260 f Available in 60mm size only. ft Available in 32mm and 40mm only. NOTE: Parts available with soldered tabs, to customer specific requirements or standard design. 4-38 SEMICONDUCTOR CH Series March 1995 Surface Mount Metal-Oxide Varistors CH Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 toStd. 1449 • Recognized as "Protectors for Data Communication and Fire Alarm Circuits", UL File #E1 35010 to Std. 497B • Surface Mount Chip Intended for Hybrid-Circuit Applications • Voltage Ratings V M(AC)RMS 10V to 275V • Available in Tape and Reel for use with Automatic Pick and Place Equipment • Compatible with Most Surface-Mounting Assembly Equipment and Techniques Description CH series transient surge suppressors are small, very com- pact metal-oxide varistors. They are intended for use in hybrid circuit applications in commercial and industrial equipment utilizing direct surface-mounting techniques. These devices, which have significantly lower profiles than traditional radial-lead varistors, permit designers to reduce the size and weight and increase the reliability of their equip- ment designs. CH series varistors are available in a voltage range from 10V to 275V V M(AC)RMS , and energy ratings up to 23J. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Characteristics chart CH SERIES UNITS Continuous: Steady State Applied Voltage: V AC Voltage Range (V M(AC)RMS ) 1 to 275 V DC Voltage Range (V M(DC) ) 1 4 to 369 Transient: Peak Pulse Current (l TM ) For 8/20ns Current Wave (See Figure 2) 250 to 500 A Single Pulse Energy Range For 1 0/1 OOOps Current Wave (W TM ) 0.8 to 23 J Operating Ambient Temperature Range (T A ) -55 to +125 °C Storage Temperature Range (T STG ) -55 to +150 °C Temperature Coefficient (aV) of Clamping Voltage (V ) at Specified Test Current <0.01 %/°C 5 ° > 0_ Copyright © Harris Corporation 1995 4-39 File Number 2186.3 Specifications CH Series Device Ratings and Specifications V82 - V240 CH Varistors are listed under UL file #E75961 as a recognized component. Series CH Varistors are listed under UL file #E135010 as a recognized component. MODEL NUMBER MAXIMUM RATINGS (+125°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT MAX CLAMPING VOLT V c AT TEST CURRENT (8/20ns) TYPICAL CAPACI- TANCE V RMS Vdc ENERGY (10/1000^s) PEAK CURRENT (8/20ns) V M(AC) V M(DC) W TM Itm MIN V N(DC) MAX Vc lp f = 1MHz (V) (V) (J) (A) (V) (V) (V) (V) (A) (pF) V22CH8 14 18 10.0 (iNoie c.) 250 18.7 22.0 26.0 47 5 1600 V £ I \jx\0 1 7 22 1 .0 250 23.0 27.0 31.1 57 5 1 300 V OOvDO 20 26 1 .2 250 29.5 33.0 36.5 68 5 1100 uqqpun 25 31 1 .5 250 35.0 39.0 43.0 79 5 900 V47rHfl 30 38 1 .8 250 42.0 47.0 52.0 800 v ju n o 35 45 2.3 250 50.0 56.0 62.0 107 5 700 V 1 £.\J\jllO 75 102 6 500 108.0 120.0 132.0 200 10 300 v i jUv>no 95 127 8.0 500 135.0 150.0 165.0 250 10 250 V180CH8 115 153 10.0 500 162.0 180.0 198.0 295 10 200 V200CH8 130 175 11.0 500 184.0 200.0 228.0 340 10 180 V220CH8 140 180 12.0 500 198.0 220.0 242.0 360 10 160 V240CH8 150 200 13.0 500 212.0 240.0 268.0 395 10 150 V360CH8 230 300 20.0 500 324.0 360.0 396.0 595 10 100 V390CH8 250 330 21.0 500 354.0 390.0 429.0 650 10 90 V430CH8 275 369 23.0 500 389.0 430.0 473.0 710 10 80 NOTES: 1 . Power dissipation of transients not to exceed 0.25W. 2. Energy rating for impulse duration of 30ms minimum to one half of peak current value. 3. Also rated to withstand 24V for 5 minutes. Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Characteristics table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. CURVE I — ic— < 80 O 30 i £ 20 -55 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING 4-40 CH Series 0, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 « Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ys Current Waveform: 8us = T, = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V18CH8 - V68CH8 PEAK AMPERES (A) 5 ° 5 DC 10 3 10 4 FIGURE 4. CLAMPING VOLTAGE FOR V82CH8 - V430CH8 Pulse Rating Curves MODEL SIZE 5 x 8mm V82CH8 - V430CH8 100 1,000 IMPULSE DURATION (us) FIGURE 5. SURGE CURRENT RATING CURVES FOR V18CH8- V68CH8 10,000 FIGURE 6. 100 1,000 IMPULSE DURATION (us) SURGE CURRENT RATING CURVES FOR V82CH8-V430CH8 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±1 0% could result. This type of shift, which normally results in a decrease of V N(DC j, may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-41 CH Series Series Dimensions Recommended Pad Outline CONTACT AREA SYMBOL INCHES MILLIMETERS MIN MAX MIN MAX D 0.080 2.03 E 0.016 0.050 0.41 1.27 L 0.311 0.335 7.90 8.51 W 0.185 0.207 4.70 5.26 Ordering Information Standard Packaging: CH Series varistors are always shipped in tape and reel. The standard 13-inch reel utilized contains 4000 pieces. Special Packaging: Option 1 -7-inch reels containing 1000 pieces are available. To order 7-inch reels add a T suffix to the part number; e.g., V47CH8T. Option 2 -For small quantities (less than 100 pieces) the units are shipped bulk pack. To order, add a S suffix to the part number; e.g., V47CH8S. Tape and Reel Specifications • Conforms to EIA-481 , Revision A • Can be Supplied to IEG Publication 286-3 SYMBOL INCHES MILLIMETERS A 0.402 10.21 B 0.216 5.50 C 0.087 2.21 NOTE: Avoid metal runs in this area. Soldering recommendations: Material - 62/36/2 Sn/Pb/Ag or equivalent. Temperature - 230°C max., 5 sec. max. Flux - R.M.A. RADIUS DETAILS SYMBOL PARAMETER SIZE (mm) Bo Cavity Length 8.5 ± 0.1 Ao Cavity Width 5.5 ± 0.1 Ko Cavity Depth 2.0 Min. Ho Ref. Plane for A and B +0.10 0.3 -0.05 Rl, F*2' ^3 Tape Cavity Radii 0.5 Max. T Carrier Tape Thickness 1.0 Max. Ti Cover Tape Thickness 0.1 Max. E Sprocket Hole from Edge 1.75 + 0.1 - Po Sprocket Hole Pitch 4.0 ± 0.1 D Sprocket Hole Diameter +0.1 1.5 -0.0 P 2 Hole Centre to Component Centre 2.0 + 0.15 R 4 Min. Bending Radius 40.0 Min. °1 Ejection Hole Dia. 1.5 Min. K Overall Thickness 3.0 Min. P Pitch Of Component 8.0 + 0.1 F Sprocket Hole to Ejection Hole 7.5 + 0.1 W Carrier Tape Width 16.0 ± 0.3 4-42 fH HL SEN CONDUCTOR CP Series March 1995 Connector Pin Metal-Oxide Varistors 16 Gauge Features • Unique Coaxial Design and Mounting Arrangement • Designed to be Integrated Within Standard Connector Assemblies • Self Contained Tubular Construction • Adds Negligible Weight and Space When Assembled Into Standard Connectors • Wide Operating Voltage Range V M(AC)RMS 6V to 150V • Can be Used with 16, 20, or 22 Gauge Connector Pins Description The CP series of transient voltage surge suppressors are connector pin metal-oxide varistors that utilize a self con- tained tubular construction. These varistors are available in a wide range of voltage ratings from 6V to 150V V M(AC)RMS , and have dimensions allowing them to be used with 16, 20, or 22 gauge connector pins. The unique coaxial mounting arrangement of these tubular varistors allow them to become part of a transmission line; thus, inductive lead effects are eliminated. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart CP SERIES Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 6 to 150 DC Voltage Range (V M(DCl ) 8 to 150 Transient: Peak Pulse Current (l TM ) For 8/20us Current Wave (See Figure 2) 250 to 500 Single Pulse Energy Range For 1 0/1 000ns Current Wave (Wjm) 1 .5 to 5 Operating Ambient Temperature Range (T A ) -55 to +125 Storage Temperature Range (T STG ) -55 to +150 Temperature Coefficient (ocV) of Clamping Voltage (V c ) at Specified Test Current <0.01 UNITS J °C °C %/°C Copyright © Harris Corporation 1995 4-43 File Number 2188.3 Device Ratings and Specifications CP Series MODEL Ml IMDCD PART SIZE MAXIMUM RATINGS (+125°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT MAX. CLAMPING VOLTAGE V c AT TEST CURRENT CAPACI- TANCE AT f = 1MHz V DC ENERGY (10/ 1000fjs) PEAK CURRENT (8/20ms) V M(AC) V M(DC) W TM 'tm MIN ^N(DC) MAX v c >P MIN MAX (V) (V) (J) (A) (V) (V) (V) (V) (A) (PF) (pF) VoGr22 22 B 6.0 8.0 1.5 250 12.5 16.0 19.5 34.0 10 1600 2950 \l -i A PDOI V 14Ur^ 22B 10.0 14.0 1.5 250 18.5 22.0 25.5 42.0 10 1600 2950 V31 L/P22 22 B 25.0 31 .0 1.5 250 35.0 39.0 48.0 85.0 5 450 1950 VJoGr22 22B 30.0 38.0 1.5 250 42.0 47.0 58.0 100.0 5 450 1950 V130GP22 22A 130.0 130.0 2.4 300 184.0 200.0 228.0 375.0 5 150 350 V150CP22 22A 150.0 150.0 2.4 300 212.0 240.0 268.0 430.0 5 100 300 V31CP20 20 B 25.0 31.0 2.0 300 35.0 39.0 48.0 85.0 10 700 2200 20B 30.0 38.0 2.0 300 42.0 47.0 58.0 100.0 10 650 1950 V1 30CP20 20A 130.0 130.0 3.0 400 184.0 200.0 228.0 375.0 10 150 400 V150CP20 20A 150.0 150.0 3.0 400 212.0 240.0 268.0 430.0 10 100 350 V38CP16 16A 30.0 38.0 3.0 350 42.0 47.0 58.0 100.0 20 1000 2750 V130CP16 16A 130.0 130.0 5.0 500 184.0 200.0 228.0 375.0 20 250 700 V150CP16 16A 150.0 150.0 5.0 500 212.0 240.0 268.0 430.0 20 200 650 Average power dissipation of transients not to exceed 250mW, 300mW and 350mW for sizes 22AWG, 20AWG and 16AWG, respectively. MODEL NUMBER PART SIZE LEAKAGE CURRENT AT V T{DC) +25°C +125°C •l TYP 'l MAX II TYP II MAX V T(DC) (HA) (HA) (HA) (UA) (V) V8CP22 22B 0.5 5.0 5.0 50 8 V14CP22 22B 0.5 5.0 5.0 50 14 V31CP22 22B 0.5 5.0 5.0 50 28 V38CP22 22B 0.5 5.0 5.0 50 36 V130CP22 22A 0.5 5.0 25.0 100 130 V150CP22 22A 0.5 5.0 25.0 100 150 V31CP20 20B 0.5 5.0 5.0 50 28 V38CP20 20B 0.5 5.0 5.0 50 36 V130CP20 20A 0.5 5.0 25.0 100 130 V150CP20 20A 0.5 5.0 25.0 100 150 V38CP16 16A 0.5 5.0 5.0 50 36 V130CP16 16A 0.5 5.0 25.0 100 130 V150CP16 16A 0.5 5.0 25.0 100 150 Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissi- pation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so devel- oped must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Further- more, the operating values need to be derated at high tempera- tures as shown in Figure 1 . Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY, AND POWER DERATING CURVE w 100 < 90 o,- J\ J I J I H- + - ft I / h \ — T, — T 2 - TIME O, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8(is = T, = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM CP Series Transient V-l Characteristics Curves 300 200 > a o > 100 90 RATING Ti = -55 6 C T H 125° /38CP16 0- 3 10" 2 10' 1 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V38CP16 10 3 3,000 2,000 > to ti §1,000 * 900 < 800 S 700 S 600 | 500 < 400 E 300 200 10 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 16 GAUGE 130 TO 150V Mli ri RATING h 55°C T 5°C » I I I — V150CP16 — — * V130CP16 linn i 10" 1 10° 10 1 PEAK AMPERES (A) 10 2 10* FIGURE 4. CLAMPING VOLTAGE FOR V130CP16 - V150CP16 20 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 20 GAUGE 31 TO 38V„, D (-i RATING T, - -5 ;°c t i 125°C * - * 1 41 IK- \ I [ \ '31C :P20 10" 3 10" 2 10* 10" 1 10° 10 PEAK AMPERES (A) FIGURE S. CLAMPING VOLTAGE FOR V31CP20 - C38CP20 10 3 3,000 2,000 h > 1,000 * 900 < 800 a 700 S 600 | 500 400 300 200 10' MAXIMUM CLAMPING VOLTAGE MODEL SIZE 20 GAUGE 130 TO 150V„,.r> RATING 55°C TC ♦ T >5°< « 1 1 I ** r ' i ^ pi 1 ' V1&UUK20 MIC — — V130CP20 I llllllll 10" 2 10' 1 10° 10 1 10 2 10 3 PEAK AMPERES (A) FIGURE 6. CLAMPING VOLTAGE FOR V130CP20 - V150CP20 10" 1 10° 10 1 PEAK AMPERES (A) 3,000 2,000 1,000 900 800 700 600 500 400 200 10" 3 10- 2 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 22 GAUGE 1 30 TO 1 50V„,. r , RATING T 1 - -55°C Tl ) + 25 C i c V130CP22 I llllllll 10 2 10 3 FIGURE 7. CLAMPING VOLTAGE FOR V31CP22 - V38CP22 10" 1 10° 10 1 PEAK AMPERES (A) FIGURE 8. CLAMPING VOLTAGE FOR V130CP22 - V150CP22 4-45 CP Series Transient V-l Characteristics Curves (Continued) PEAK AMPERES (A) PEAK AMPERES (A) FIGURE 9. CLAMPING VOLTAGE FOR V14CP22 FIGURE 10. CLAMPING VOLTAGE FOR V8CP22 Pulse Rating Curves ' 20 100 1,000 10,000 ' 20 100 1,000 10,000 IMPULSE DURATION ((is) IMPULSE DURATION (us) FIGURE 11. SURGE CURRENT RATING CURVES FOR V38CP16 FIGURE 12. SURGE CURRENT RATING CURVES FOR V130CP16-V150CP16 4-46 CP Series Pulse Rating Curves (Continued) 1,000 IMPULSE DURATION (ps) FIGURE 15. SURGE CURRENT RATING CURVES FOR V8CP22 - V38CP22 10,000 FIGURE 16. SURGE CURRENT RATING CURVES FOR V130CP22- V150CP22 NOTE: If pulse ratings are exceeded, a shift of V N(D c) (at specified current) of more than ±1 0% could result. This type of shift, which nor- mally results in a decrease of V N(D c). may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. Package Outline Dimensions EXTERNAL ELECTRODE PASSIVATION INTERNAL ELECTRODE 11.0 (0.433) MAX 10.0 (0.394) MIN 1 DIMENSIONS PART SIZE INTERNAL DIAMETER (D,) EXTERNAL DIAMETER (D 2 ) PASSIVATION DIAMETER (D 3 ) MIN MAX MIN MAX MIN MAX 22A 0.86 (0.034) 1.02 (0.040) 1.73 (0.068) 1.88 (0.074) 1.83 (0.072) 1.98 (0.078) 22B 0.86 (0.034) 1.25 (0.049) 1.73 (0.068) 1.88 (0.074) 1.83 (0.072) 1.98 (0.078) 20A 1.09 (0.043) 1.25 (0.049) 2.08 (0.082) 2.39 (0.094) 2.18 (0.086) 2.54 (0.100) 20B 1.09 (0.043) 1.83 (0.072) 2.08 (0.082) 2.39 (0.094) 2.18 (0.086) 2.54 (0.100) 16A 2.27 (0.090) 2.41 (0.095) 3.40 (0.134) 3.56 (0.140) 3.50 (0.138) 3.56 (0.144) NOTE: Dimensions in millimeters and (inches) 4-47 SI SEMICONDUCTOR CS Series March 1995 Connector Pin Metal-Oxide Varistors CS SERIES Features • Unique Coaxial Design and Mounting Arrangement • Designed to be Integrated Within Standard Connector Assemblies • Wide Operating Voltage Range V M(DC) 8V to 38V • Self Contained Tubular Construction • Less Than Half the Length of Standard CP Series Description The CS series of transient voltage surge suppressors are connector pin metal-oxide varistors that utilize a self con- tained tubular construction. They are designed to provide transient surge protection in connector/filter applications in aerospace, automotive, computer and associated industries. These varistors are available in a wide range of voltage rat- ing from 8V DC to 38V DC . The CS series of connector suppressors are of similar pack- age construction to the Harris CP series, but differ in size, ratings and characteristics. They offer the advantage of small size and light weight; key benefits in connector assem- blies. The unique coaxial mounting arrangement of the CS series allows them to become an integral part of a transmis- sion line; thus, inductive lead effects are eliminated. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart CS SERIES UNITS Continuous: Steady State Applied Voltage: DC Voltage Range (V M(DC) ) 8 to 38 V Transient- Peak Pulse Current (I™) For 8/20(js Current Wave (See Figure 2) 80 to 1 00 A Single Pulse Energy Range (W TM ) For 10/1 000(is Current Wave 0.5 J Operating Ambient Temperature Range (T A ) -55 to +125 °C Storage Temperature Range (T STG ) -55 to +150 °C Temperature Coefficient (ccV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Copyright © Harris Corporation 1 995 File Number 2972.2 Specifications CS Series Device Ratings and Specifications MAXIMUM RATINGS (+125°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT ■ ■A Villi III MAXIMUM CLAMPING VOLTAGE V c AT 10A (8/20ns) CAPACITANCE AT f = 1MHz Vdc ENERGY (10/1 000ns) PEAK CURRENT (8/20(18) V N(DC) C MODEL NUMBER PART SIZE V M(DC) w TM ku MIN MAX Vc MIN MAX (V) (V) (A) (V) (V) (pF) V8CS22 22B 8 0.5 80 13.5 19.5 36 830 1550 V14CS22 22B 14 0.5 80 18.5 25.5 44 675 1250 VI BOo22 22B 18 0.5 80 22.5 27.9 47 600 1200 V22CS22 22B 22 0.5 100 27.5 34.5 57 540 1050 V26CS22 22B 26 0.5 100 29.5 36.5 68 510 960 V31CS22 22B 31 0.5 100 35.0 48.0 85 450 880 V38CS22 22B 38 0.5 100 42.0 58.0 100 350 770 NOTE: Average power dissipation of transients not to exceed 200mW LEAKAGE CURRENT AT V M(DC ) MODEL NUMBER +25°C +125°C l L TYP l L MAX l L TYP l L MAX (MA) (HA) V8CS22 0.5 5.0 5.0 50 V14CS22 0.5 5.0 5.0 50 V18CS22 0.5 5.0 5.0 50 V22CS22 0.5 5.0 5.0 50 V26CS22 0.5 5.0 5.0 50 V31CS22 0.5 5.0 5.0 50 V38CS22 0.5 5.0 5.0 50 4-49 CS Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts for average power 80 £ 30 ol^ -55 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE Package Outline Dimensions INTERNAL /ELECTRODE DIMENSIONS PART SIZE INTERNAL DIAMETER (D1) EXTERNAL DIAMETER (D2) PASSIVATION DIAMETER (D3) MIN MAX MIN MAX MIN MAX 22B 0.86 (0.034) 1.25 (0.049) 1.73 (0.068) 1.88 (0.074) 1.83 (0.072) 1.98 (0.078) NOTE: Dimensions in millimeters and (inches) (0.173 ±0.010) "CS" DIMENSION OUTLINE NOTE: 1 . The CS series of connector pin varistors may also be obtained in gauge sizes 16A, 20A, 20B. and 22A AWG, and with continuous operating voltages of up to 1 00 volts dc. For information on avail- ability of different voltages and sizes, please contact Harris Semiconductor Power Marketing. 4-50 23 SEMICONDUCTOR DA/DB Series March 1995 Industrial High Energy Metal-Oxide Varistors DB SERIES Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 to Std. 1449 • High Energy Absorption Capability W TM UpTo 1050J • Wide Operating Voltage Range V M(AC)RMS 130V to 750V • Rigid Terminals for Secure Wire Contact (DA Series) • Case Design Provides Complete Electrical Isolation of Disc Subassembly 40mm Description DA and DB series transient surge suppressors are heavy- duty industrial metal-oxide varistors designed to provide surge protection for motor controls and power supplies used in oil-drilling, mining, and transportation equipment. Possible voltage surges in their AC power supplies could cause product failure and the subsequent faulty operation of these systems. These UL-recognized varistors have identical ratings and specifications but differ in case construction to provide flexi- bility in equipment designs. DA series devices feature rigid terminals to insure secure wire contacts. Both the DA and DB series feature improved creep and strike distance capability to minimize breakdown along the package surface design that provides complete electrical isolation of the disc subassembly. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) DC Voltage Range (V M(DC) ) Transient: Peak Pulse Current (l TM ) For 8/20ms Current Wave (See Figure 2) Single Pulse Energy Range For 10/1000us Current Wave [W m ) Operating Ambient Temperature Range (T A ) Storage Temperature Range (T STG ) Temperature Coefficient (otV) of Clamping Voltage (V c ) at Specified Test Current Hi-Pot Encapsulation (Isolation Voltage Capability) (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) Insulation Resistance DA/DB SERIES 130 to 750 175 to 970 UNITS 30,00010 40,000 A 270 to 1050 -55 to +85 -55 to +125 <0.01 5000 1000 J °C °C %/°C V MQ DC Yl > 0. Copyright © Harris Corporation 1 995 4-51 File Number 2189.3 Specifications DA/DB Series Device Ratings and Specifications Series DA and DB Varistors are listed under UL file #E75961 as a UL recognized component. MODEL NUMBER MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT MAX CLAMPING VOLT V c AT 200A CURRENT (8/20|iS) TYPICAL CAPACI- TANCE V RMS Vdc ENERGY (2ms) PEAK CURRENT (8/2 0. 100 1,000 IMPULSE DURATION ( ( js) FIGURE 5. SURGE CURRENT RATING CURVES FOR V421 DA40, V421 DB40 - V751 DA40 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±10% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-53 DA/DB Series Package Outline Dimensions DA SERIES DB SERIES "A" DIMENSION: FILISTER HEAD SCREW - 51mm (2.01) PAN HEAD SCREW - 53mm (2.09) (0.170) L r -=L 15mm (0.59) mT+nni? M4 INTERNATIONAL (0.90 ± 0.04) THREAD 4.5mm (0.18) 46.8 (1.84) 60.3 (2.37) 44.45 ±0.75 (1.75 ±0.03) a t ALL DIMENSIONS ARE MAXIMUM EXCEPT WHERE NOTED 25.4 ± 0.75 (1.00 ±0.03) HOLES 0.21 THRU BORE 0.343 x 0.328 DP 1.6 (0.06)- 23 (0.90) 40.5_ "(1.6) 12.7 _ (0.50) 2 HOLES H- <>- -<> 6.35 (0.25) 41 (1.61) 12.7 " (0.50) 1- 6.35 (0.25) Dimensions in millimeters and (inches). 4-54 SI SEMICONDUCTOR HA Series March 1995 Industrial High Energy Metal-Oxide Varistors HA SERIES Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 to Std. 1449 • Recognised as "Transient Voltage Surge Suppressors", CSA File #LR91788 to Standard C22.2 No. 1-M1981 • Wide Operating Voltage Range V M(AC)RMS 130V to 750V • Two Model Sizes Available 32mm and 40mm • High Energy Absorption Capability W TM = 200J to 1050J • High Peak Pulse Current Capability I TM = 25.000A to 40.000A • Rigid Terminals for Secure Mounting • Available in Clipped Version for Through Hole Board Mounting - Designation "HC" Description HA series transient surge suppressors are industrial high The HA series of industrial varistors have similar package energy metal-oxide varistors. They are designed to provide construction but differ in size, (32mm and 40mm), ratings secondary surge protection in the outdoor and service and specifications. The design of the HA series of metal entrance environment (distribution panels), in computers, oxide varistors provide rigid terminals to insure secure and also in industrial applications for motor controls and mounting. Also available in a clipped version for through power supplies used in the oil-drilling, mining, and transpor- hole board placement - designation "HC". tation fields. Possible voltage transients in the ac power net- work could cause product failure and the subsequent faulty operation of these systems. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart HA SERIES UNITS Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 130 to 750 V DC Voltage Range (V M(DC) ) 175 to 970 V Transient: Peak Pulse Current (l TM ) For 8/20ns Current Wave (See Figure 2) 25,000 to 40,000 A Single Pulse Energy Range For 1 0/1 000ns Current Wave (W TM ) 200 to 1 050 J Operating Ambient Temperature Range (T A ) -55 to +85 °C Storage Temperature Range (T STG ) -55 to +125 °C Temperature Coefficient (ctV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Hi-Pot Encapsulation (Isolation Voltage Capability) 2500 V (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) Insulation Resistance 1000 M£J rr « < rr > Q. Copyright © Harris Corporation 1995 4-55 File Number 2973.3 Specifications HA Series Device Ratings and Specifications HA Series varistors are listed under CSA File #LR91788 as a recognized component. HA Series varistors are listed under U.L. File #E75961 as a recognized component. MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT MAXIMUM CLAMPING PEAK VARISTOR VOLTAGE VOLTAGE TYPICAL ENERGY CURRENT AT 1 mA DC TEST (V c ) AT 200A CAPACITANCE V RMS Vdc (2ms) (8/20jiS) CURRENT (8/2 0ns) AT f = 1MHz MODEL V M(AC) V M(DC) W TM •tm MIN VfJ(DC) MAX Vc C NUMBER (V) (V) ENERGY (A) (V) AM (V) (v) (V) (PF) V131HA32 130 175 200 25000 184 200 228 350 4700 V131HA40 130 175 270 30000 184 200 228 345 10000 V151HA32 150 200 220 25000 212 240 268 410 4000 V151HA40 150 200 300 30000 212 240 268 405 8000 V251HA32 250 330 330 25000 354 390 429 650 2500 V251HA40 330 370 40000 354 390 429 630 5000 V271HA32 275 369 360 25000 389 430 473 710 2200 V271HA40 275 369 400 40000 389 430 473 690 4500 V321HA32 320 420 390 25000 462 510 539 845 1 900 V321HA40 320 420 460 40000 462 510 539 825 3800 V421HA32 420 560 400 25000 610 680 748 1 1 20 1500 V421HA40 420 560 600 40000 610 680 748 1100 3000 V481HA32 480 640 450 25000 670 750 825 1290 1300 V481HA40 480 640 650 40000 670 750 825 1230 2700 V511HA32 510 675 500 25000 735 820 910 1355 1200 V511HA40 510 675 700 40000 735 820 910 1295 2500 V571HA32 575 730 550 25000 805 910 1000 1570 1100 V571HA40 575 730 770 40000 805 910 1000 1480 2200 V661HA32 660 850 600 25000 940 1050 1160 1820 1000 V661HA40 660 850 900 40000 940 1050 1160 1720 2000 V751HA32 750 970 700 25000 1080 1200 1320 2050 800 V751HA40 750 970 1050 40000 1080 1200 1320 2000 1800 NOTE: Average power dissipation of transients not to exceed 1 5W and 2.0W for model sizes 32mm and 40mm, respectively. Power Dissipation Ratings Continuous power dissipation capability is not an applicable requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure I. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts for average power dissipation. AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE 4-56 HA Series O, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20^is Current Waveform: 8(is »T»» Virtual Front Time 20(is = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT WAVEFORM Transient V-l Characteristics Curves 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V131HA32 - V751HA32 10° 10 1 10 2 10 3 PEAK AMPERES (A) FIGURE 4. CLAMPING VOLTAGE FOR V131HA40 - V751HA40 Pulse Rating Curves 50,000 100 1,000 IMPULSE DURATION (us) FIGURE 5. SURGE CURRENT RATING CURVES FOR V131HA32-V751HA32 100 1,000 IMPULSE DURATION ( M s) FIGURE 6. SURGE CURRENT RATING CURVES FOR V131HA40-V151HA40 10,000 4-57 HA Series Packaging Id hH TABLE t HA SERIES OUTUNE SPECIFICATIONS (Dimensions in Millimeters) D H I X 0A T T1 S MAX MAX MIN NOM MAX NOM NOM OFFSET HA32 35.5 52.00 3.0 25 4.20 9.30 10.4 Depends on Device Voltage (See Table 2) HA40 42.5 57.00 3.0 25 4.20 9.30 10.4 it hH TABLE 3. HC SERIES OUTLINE SPECIFICATIONS (Dimensions in Millimeters) D H B X T R Sc MAX MAX MIN NOM NOM MAX OFFSET HC32 35.5 52.00 5.0 25 9.30 1.0 Depends on Device Voltage (See Table 4) HC40 42.5 57.00 5.0 25 9.30 1.0 TABLE 2. HA SERIES MAXIMUM THICKNESS AND TERMINAL OFFSETS (Dimensions in Millimeters) TABLE 4. HC SERIES MAXIMUM THICKNESS ANDTERMINAL OFFSETS (Dimensions in Millimeters) THICKNESS "W" DIMENSION "S" (±1mm) THICKNESS "W" DIMENSION "S c " (±1mm) VOLTAGE HA32 HA40 HA32 HA40 VOLTAGE HC32 HC40 HC32 HC40 V131 - V321 9.00 9.00 3.90 3.90 V131 - V321 9.00 9.00 6.00 6.00 V421 - V511 11.00 11.00 2.60 2.60 V421 - V511 11.00 11.00 7.30 8.10 V571 - V751 13.00 13.00 1.00 1.00 V571 - V751 13.00 13.00 8.90 10.00 4-58 33 SEMICONDUCTOR LA Series June 1995 UL Recognized Radial Lead Metal-Oxide Varistors for Line Voltage Operation Features 7mm, 10mm, 14mm, 20mm LA SERIES • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 to Standard 1449 • Recognized as "Across-The-Line Components", UL File #E56529 to Standard 1414 • Recognized as "Protectors for Data Communication and Fire Alarm Circuits", UL File #E1 35010 to Standard 497B • Recognized as "Transient Voltage Surge Suppressors", CSA File #LR91788 to Standard C22.2 No. 1 - M1981 • High Energy Absorption Capability W TM Up to 360J • Wide Operating Voltage Range V M(AC)RMS 130V to 750V • Line-Voltage Operation - Can be Operated Directly Across 120V, 240V, etc., AC Power Lines • Available in Tape and Reel for Automatic Insertion Equipment Description LA series transient surge suppressors are radial-lead varis- tors that can be operated continuously across AC power lines. These UL recognized varistors "across-the-line" com- ponents, because of their radial lead construction, require very little mounting space. This feature is particularly impor- tant in compact, hard wired system designs. LA series varistors are available in four model sizes: 7mm, 10mm, 14mm and 20mm; and have a V M(AC)RMS voltage range from 130V to 1000V, and an energy absorption capability up to 360J. Some LA series model numbers are available with two clamping voltage selections, designated by a model number prefix of either A or B. The "A" selection is the standard model; the "B" selection provides a tighter clamping voltage. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications LA SERIES Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 1 30 to 1 000 DC Voltage Range (V M(DC) 175 to 1 200 Transients: Peak Pulse Current (l TM ) For 8/20ns Current Wave (See Figure 2) 1 200 to 6500 Single Pulse Energy Range For 10/1000(is Current Wave (W TM ) 11 to 360 Operating Ambient Temperature Range (T A ) -55 to +85 Storage Temperature Range (T STG ) -55 to +125 Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 Hi-Pot Encapsulation (Isolation Voltage Capability) 2500 (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) Insulation Resistance 1000 chart UNITS J °C °C %/°c V Copyright © Harris Corporation 1 995 4-59 File Number 2190.3 Specifications LA Series Device Ratings and Specifications Series LA Varistors are listed under UL file #E75961 and E56529 as a recognized component. Series LA Varistors are listed under CSA file #LR91788 as a recognized component. MAXIMUM RATING (85°C) SPECIFICATIONS (25°C) CONTINUOUS TRANSIENT VARISTOR MAXIMUM TYPICAL MODEL SIZE DISC V RMS Vdc ENERGY 10x1000(is PEAK CURRENT 8 X 20|JS VOLTAGE AT 1mA DC TEST CURRENT CLAMPING VOLTAGE 8 x 20(is CAPACI- TANCE f = 1MHz MODEL DEVICE V M(AC) V M(DC) Wtm !tm V NOM MIN V NOM MAX v c Irk c NUMBER Dl A. (mm) MARKING (V) ( V ) (J) (A) (V) (V) (A) ipn vnni ai 7 1301 130 1 75 1 200 184 255 390 10 1 80 V 1 JuLnt 7 1302 130 175 1 1 1200 184 228 340 10 180 V130LA5 10 1305 130 175 20 2500 184 228 340 25 450 V I JULM i UM 1 4 130L1 130 175 38 4500 184 228 340 50 1000 V i JULntUn 20 130L20 130 175 70 6500 184 228 340 100 1900 V I oULMtUD 20 130 175 70 6500 184 220 325 100 1900 "7 / 1 402 140 180 12 1200 198 242 360 10 160 V I <+ULM3 1 1405 140 180 22 2500 198 242 360 25 400 V140I A10A 14 140L10 140 180 42 4500 198 242 360 50 900 \/i/ini Aoni 140L20 140 180 75 6500 198 242 340 100 1750 \/icni Ai V l OULA 1 7 1 501 150 200 13 1200 212 284 430 10 150 \m cm ao V 1 OULAt 7 1 502 150 200 13 1200 212 268 395 10 150 10 1505 150 200 25 2500 212 268 395 25 360 \/1Cnl A1DA 1 4 1 50L1 150 200 45 4500 212 268 395 50 800 V ICULM^UM 20 1 50L20 150 200 80 6500 212 268 395 100 1600 20 150 200 80 6500 212 243 360 100 1 600 V175LA2 7 1752 175 225 15 1200 247 303 455 10 130 10 1 755 175 225 30 2500 247 303 455 25 350 \Z17RI A10A 14 175L10 175 225 55 4500 247 303 455 50 700 V175LA20A 20 175L20 175 225 90 6500 247 303 455 100 1400 V230LA4 7 2304 230 Qnn on 1 onn 324 396 595 10 100 V230LA10 10 230 L 230 300 35 2500 324 396 595 25 250 V230LA20A 14 230L20 230 300 70 4500 324 396 595 50 550 V230LA40A 20 230L40 230 300 122 4500 324 396 595 50 1100 V250LA2 7 2502 250 330 21 1200 354 473 730 10 90 V250LA4 7 2504 250 330 21 1200 354 429 650 10 90 V250LA10 10 250L 250 330 40 2500 354 429 650 25 220 V250LA20A 14 250L20 250 330 72 4500 354 429 650 50 500 V250LA40A 20 250L40 250 330 130 6500 354 429 650 100 1000 V250LA40B 20 250L40B 250 330 130 6500 354 413 620 100 1000 V275LA2 7 2752 275 369 23 1200 389 515 775 10 80 V275LA4 7 2754 275 369 23 1200 389 473 710 10 80 V275LA10 10 275L 275 369 45 2500 389 473 710 25 200 V275LA20A 14 275L20 275 369 75 4500 389 473 710 50 450 V275LA40A 20 275L40 275 369 140 6500 389 473 710 100 900 V275LA40B 20 275L40B 275 369 140 6500 389 453 680 100 900 4-60 Specifications LA Series Device Ratings and Specifications (Continued) Series LA Varistors are listed under UL file #E75961 and E56529 as a recognized component. Series LA Varistors are listed under CSA file #LR91788 as a recognized component. MAXIMUM RATING (85°C) CONTINUOUS TRANSIENT VARISTOR MAXIMUM TYPICAL PEAK VOLTAGE AT CLAMPING CAPACI- ENERGY CURRENT 1mA DC TEST VOLTAGE TANCE MODEL SIZE DISC V RMS Vdc 10 x IOOOjis 8 x 20us CURRENT 8 x 20us f = 1MHz MODEL DEVICE V M(AC) V M(DC) W tm 'tm V NOM MIN v NOM MAX Vc >PK C NUMBER DIA. (mm) MARKING (V) (V) (J) (A) (V) (V) (A) (pF) V300LA2 7 3002 300 405 25 1200 420 565 870 10 70 V300LA4 7 3004 300 405 25 1200 420 517 775 10 70 V300LA10 10 300L 300 405 46 2500 420 517 775 25 180 V300LA20A 14 300L20 300 405 77 4500 420 517 775 50 400 V300LA40A 20 300L40 300 405 165 6500 420 517 775 100 800 V320LA7 7 3207 320 420 25 1200 462 565 850 10 65 V320LA10 10 320L 320 420 48 2500 462 565 850 25 170 V320LA20A 14 320L20 320 420 80 4500 462 565 850 50 380 V320LA40B 20 320L40 320 420 150 6500 462 540 810 100 750 V385LA7 7 3857 385 505 27 1200 558 682 1025 10 60 V385LA10 10 385L 385 505 51 2500 558 682 1025 25 160 V385LA20A 14 385L20 385 505 85 4500 558 682 1025 50 360 V385LA40B 20 385L40 385 505 160 6500 558 682 1025 100 700 V420LA7 7 4207 420 560 30 1200 610 748 1120 10 55 V420LA10 10 420L 420 560 55 2500 610 748 1120 25 140 V420LA20A 14 420L20 420 560 90 4500 610 748 1120 50 300 V420LA40B 20 420L40 420 560 160 6500 610 720 1060 100 600 V460LA7 7 4607 460 615 37 1200 702 858 1130 10 55 V480LA7 7 4807 480 640 35 1200 670 825 1240 10 270 V480LA10 10 480 L 480 640 60 2500 670 825 1240 25 120 V480LA40A 14 480L40 480 640 105 4500 670 825 1240 50 270 V480LA80B 20 480L80 480 640 180 6500 670 790 1160 100 550 V510LA10 10 510L 510 675 63 2500 735 910 1350 25 100 V510LA40A 14 510L40 510 675 110 4500 735 910 1350 50 250 V510LA80B 20 510L80 510 675 190 6500 735 860 1280 100 500 VO/bLAlU 10 575L 575 730 65 2500 805 1000 1500 25 90 V575LA40A 14 575L40 575 730 120 4500 805 1000 1500 50 220 V575LA80B 20 575L80 575 730 220 6500 805 960 1410 100 450 V625LA10 10 625L 625 825 67 4500 940 1210 1820 25 80 V625LA40A 14 625L40 625 825 125 4500 940 1210 1820 50 210 V625LA80B 20 625L80 625 825 230 6500 940 1100 1650 100 425 V660LA10 10 660L 660 850 70 2500 940 1210 1820 50 70 V660LA50A 14 660L50 660 850 140 4500 940 1210 1820 50 200 V660LA100B 20 660L100 660 850 250 6500 940 1100 1650 100 400 V1000LA80A 14 1000L80 1000 1200 220 4500 1425 1800 2700 50 130 V1000LA160B 20 1000L160 1000 1200 360 6500 1425 1600 2420 100 250 SPECIFICATIONS (25°C) NOTE: Average power dissipation of transients not to exceed 0.25W, 0.4W, 0.6W or 1W for model sizes 7mm, 10mm, 14mm and 20mm, respectively. 4-61 LA Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE 111 100 0, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8)is = T, = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V130LA1 - V300LA2 10"* 10" 10' 10' PEAK AMPERES (A) FIGURE 4. CLAMPING VOLTAGE FOR V130LA2 - V300LA4 4-62 10- 3 10' 2 10" 1 10° 10' PEAK AMPERES (A) FIGURE 5. CLAMPING VOLTAGE FOR V320LA7 - V480LA7 10" 1 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 6. CLAMPING VOLTAGE FOR V130LA5 - V420LA10 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 10mm 300 TO 660V„( AC) RATING T. = -55°C TO +85°C 10"' 10" 10 PEAK AMPERES (A) 10 1 10° 10 1 10 2 PEAK AMPERES (A) s ° < 0C > Q. FIGURE 7. CLAMPING VOLTAGE FOR V300LA10 - V660LA10 FIGURE 8. CLAMPING VOLTAGE FOR V130LA1 OA - V320LA20A 4-63 LA Series Transient V-l Characteristics Curves (continued) 3,000 2,000 > <-, > 1,000 900 2 800 a 700 £ 600 E 500 X < 400 5 300 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 20mm 130 TO 275Vm( AC) RATING T. = -55°C TO +85°C W 3 10" 2 10" 1 10° 10 1 10 2 10 3 10 4 PEAK AMPERES (A) FIGURE 11. CLAMPING VOLTAGE FOR V130LA20B - V275LA40B MAXIMUM CLAMPING VOLTAGE MODEL SIZE 20mm 140 TO 230V U(AC) RATING T A = -55°CTO+85°C PEAK AMPERES (A) FIGURE 12. CLAMPING VOLTAGE FOR V140LA20A - V230LA40A Pulse Rating Curves 20 100 1,000 10,000 IMPULSE DURATION (us) FIGURE 14. SURGE CURRENT RATING CURVES FOR V1 30LA1 - V480LA7 20 100 1,000 10,000 IMPULSE DURATION (us) FIGURE 15. SURGE CURRENT RATING CURVES FOR V1 30LA5 - V660LA10 4-64 LA Series Pulse Rating Curves (continued) 5,000 100 1,000 IMPULSE DURATION (us) FIGURE 16. SURGE CURRENT RATING CURVES FOR V130LA10A - V320LA20A 10,000 MODEL SIZE 14mm V385LA20A • V1000LA80A fg?ffj» g5:g:^:gS;ggs;PIII 20 100 1,000 IMPULSE DURATION (us) FIGURE 17. SURGE CURRENT RATING CURVES I V385LA20A - V1000LA80A 00 1,000 IMPULSE DURATION ((is) FIGURE 18. SURGE CURRENT RATING CURVES FOR V130LA20A - V320LA40B MODEL SIZE 20mm V385LA40B - V1000LA160B rr w °§ 5 ° > a 100 1,000 IMPULSE DURATION (us) FIGURE 19. SURGE CURRENT RATING CURVES FOR V385LA40B - V1000LA160B 10,000 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than +1 0% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but does not prevent the device from continuing to function, and to provide ample protection. 4-65 LA Series Tape and Reel Specifications CRIMPED LEADS ■LT ^+D Conforms to ANSI and EIA specifications Can be supplied to IEC Publication 286-2 Radial devices on tape are supplied with crimped leads, straight leads, or under-crimped leads STRA.GHT LEADS _| Pi L_ | J F [_\^D UNDER-CRIMPED LEADS "LU" -p,U- I — P300V 500 500 500 20mm <300V 500 500 500 20mm S300V 500 500 500 Package Outline Dimensions --0D w 25.4 (1.00) MIN T SYMBOL VOLTAGE MODEL VARISTOR MODEL SIZE 7mm 10mm 14mm 20mm MIN MAX MIN MAX MIN MAX MIN MAX A V130LA- V320LA 7.5 (0.295) 12 (0.472) 10 (0.394) 16 (0.630) 13.5 (0.531) 20 (0.787) 17.5 (0.689) 26.5 (1.043) V420LA- V1000LA 10 (0.394) 17 (0.689) 13.5 (0.531) 20.5 (0.807) 17.5 (0.689) 28 (1.102) 0D All 7.5 (0.295) 9 (0.354) 10 (0.394) 12.5 (0.492) 13.5 (0.531) 17 (0.669) 17.5 (0.689) 23 (0.906) e (Notel) All 4 (0.157) 6 (0.236) 6.5 (0.256) 8.5 (0.335) 6.5 (0.256) 8.5 (0.335) 6.5 (0.256) (Notel) 8.5 (0.335) (Note 1 ) Si V130LA- V320LA 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) V420LA- V1000LA 2.5 (0.098) 5.5 (0.217) 2.5 (0.098) 5.5 (0.217) 2.5 (0.098) 5.5 (0.217) E V130LA- V320LA 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) V420LA- V660LA 7.3 (0.287) 7.3 (0.287) 7.3 (0.287) 7.3 (0.287) V1000LA 10.8 (0.425) 10.8 (0.425) 0b All (Note 2) 0.585 (0.023) 0.685 (0.027) 0.76 (0.030) 0.86 (0.034) 0.76 (0.030) 0.86 (0.034) 0.76 (0.030) (Note 1) 0.86 (0.034) (Note 1 ) NOTE: Dimensions in millimeters, inches in parentheses. 1 . 10mm ALSO AVAILABLE; See Additional Lead Style Options 2. 1000V parts only supplied with lead wire of diameter 1 .00 ± 0.05 (0.039 ± 0.002). 4-67 LA Series Additional Lead Style Options Radial lead types can be supplied with combination pre- formed crimp and trimmed leads. This option is supplied to the dimensions shown. "Seating plane interpretation per IEC-717 CRIMPED AND TRIMMED LEAD SYMBOL VARISTOR MODEL SIZE 7mm 10mm 14mm 20mm MIN MAX MIN MAX MIN MAX MIN MAX A 15 (0.591) 19.5 (0.768) 22.5 (0.886) 29.0 (1.142) Ltrim 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) NOTE: Dimensions in millimeters, inches in parentheses. To order this crimped and trimmed lead style, standard radial type model numbers are changed by replacing the model let- ter "A" with "C". Example: • For 10/±1mm lead spacing on 20mm diameter models only; append standard model numbers by adding "X10". Example: STANDARD CATALOG MODEL ORDER AS: V130LA2 V130LC2 STANDARD CATALOG MODEL ORDER AS: V130LA20A V130LA20AX10 For crimped leads without trimming and any variations to the above, contact Harris Semiconductor Power Market- ing. 4-68 SEMICONDUCTOR MA Series March 1995 Axial Lead Metal-Oxide Varistors Features • 3mm Diameter Disc Size • Wide Operating Voltage Range V M(AC)RMS 9V to 264V • Available in Tape and Reel Packaging for Use With Automatic Insertion Equipment MA SERIES Description MA series transient surge suppressors are axial-lead metal- oxide varistors for use in a wide variety of industrial and commercial electronic equipment. The construction of these 3mm diameter disc-type axial lead varistors make them par- ticularly useful in automatic insertion equipment. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 9 to 264 DC Voltage Range (V M(DC) ) 13 to 365 Transient: Peak Pulse Current (l TM ) For 8/20p.s Current Wave (See Figure 2) 40 to 1 00 Single Pulse Energy Range For 10/1 000ms Current Wave (W TM ) 0.06 to 1 .7 Operating Ambient Temperature Range (T A ) -55 to +85 Storage Temperature Range (T STG ) -55 to +125 Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 Hi-Pot Encapsulation (Isolation Voltage Capability) 1000 (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) Insulation Resistance 1000 UNITS J °C °c %/°c V 5 ° Copyright © Harris Corporation 1995 File Number 2191.3 Specifications MA Series Device Ratings and Specifications MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT MAX CLAMPING ENERGY PEAK VARISTOR VOLTAGE AT lifil T AT ■ VOLT AT lp 1 YrlUAL (10/ CURRENT 1mA DC TEST VALUE CURRENT CAPACI- DEVICE MARK- V RMS Vdc 1000ns) (8/20tis) CURRENT (8/20ns) TANCE MODEL V IUI(AC) V M(DC) W TM 'tm MIN V N(DC) MAX lp = 2. OA f = 1MHz NUMBER ING (V) (V) (J) (A) (V) (V) (V) (V) (PF) V18MA1A 18A 9 13 0.06 40 14 18 23 49 550 V18MA1B 18B 10 14 0.07 40 15 18 21 44 550 V18MA1S 18S 10 14 0.06 40 15 18 21 49 550 V22MA1A 22A 10 15 0.09 40 16 22 28 55 410 V22MA1 B 22B 14 18 0.10 40 19 22 26 51 410 V22MA1S 22S 14 18 0.09 40 1 Q 22 26 55 410 V27MA1A 27A 13 19 0.10 40 21 27 34 67 370 V27MA1B 27B 17 22 0.11 40 24 27 31 59 370 V27MA1S 27S 7 U. 1 u 40 24 27 31 67 370 V33MA1A 33A 18 23 0.13 40 26 33 40 73 300 V33MA1B 33B 20 26 0.15 40 29 5 33 36.5 67 300 V33MA1S 33S 20 26 0.14 40 29.5 33 36.5 73 300 V39MA2A 39A 22 28 0.16 40 31 39 47 86 250 V39MA2B 39B 25 31 0.18 40 35 39 43 79 250 V39MA2S 39S 25 31 0.17 40 35 39 43 86 250 V47MA2A 47A 27 34 0.19 40 37 47 57 99 210 V47MA2B 47B 30 38 0.21 40 42 47 52 90 210 V47MA2S 47S 30 38 0.19 40 42 47 52 99 210 V56MA2A 56A 32 40 0.23 40 44 56 68 117 180 V56MA2B 56B 35 45 0.25 40 50 56 62 108 180 V56MA2S 56S 35 45 0.23 40 50 56 62 117 180 V68MA3A 68A 38 48 0.26 40 OH 68 82 138 150 V68MA3B 68B 40 56 30 40 61 68 75 127 150 V68MA3S 68S 40 56 0.27 40 61 68 75 138 150 V82MA3A 82A 45 60 33 40 65 82 99 163 120 V82MA3B 82B 50 66 0.37 40 73 82 91 150 120 V82MA3S 82S 50 66 0.34 40 73 82 91 163 120 V100MA4A 100 57 72 0.40 40 80 100 120 200 100 V100MA4B 101 60 81 0.45 40 90 100 110 185 100 V1 00MA4S 102 60 81 0.42 40 90 100 110 200 100 V120MA1A 120 72 97 0.40 100 102 120 138 220 40 V1 20MA2B 121 75 101 0.50 100 108 120 132 205 40 V120MA2S 122 75 101 0.46 100 108 120 132 220 40 V150MA1A 150 88 121 0.50 100 127 150 173 255 32 V150MA2B 151 92 127 0.60 100 1 35 1 50 1 65 240 32 V180MA1A 180 105 144 0.60 100 153 180 207 310 27 V180MA3B 181 110 152 0.70 100 162 180 198 290 on V220MA2A 220 132 181 0.80 100 187 220 253 380 21 V220MA4B 221 138 191 0.90 100 198 220 242 360 21 V270MA2A 270 163 224 0.90 100 229 270 311 460 17 V270MA4B 271 171 235 1.00 100 243 270 297 440 17 V330MA2A 330 188 257 1.00 100 280 330 380 570 14 V330MA5B 331 200 274 1.10 100 297 330 363 540 14 V390MA3A 390 234 322 1.20 100 331 390 449 670 12 V390MA6B 391 242 334 1.30 100 351 390 429 640 12 V430MA3A 430 253 349 1.50 100 365 430 495 740 11 V430MA7B 431 264 365 1.70 100 387 430 473 700 11 NOTE: Average power dissipation of transients not to exceed 200mW. ■ 4-70 MA Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE O, = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8|iS = Ti = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value £ ° < oc > a. FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves 10" 1 10° 10 1 PEAK AMPERES (A) 10"' 10° PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V1 8MA1 A/S - V100M A4A/S FIGURE 4. CLAMPING VOLTAGE FOR V120MA1 A/S - V430MA3A 4-71 MA Series Pulse Rating Curves NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±1 0% could result. This type of shift, which normally results in a decrease of V N( p C ), may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-72 MA Series Package t r I ■* L » » G — ► * L »■ SYMBOL INCHES MILLIMETERS MIN MAX MIN MAX 0b 0.024 0.026 0.61 0.66 0D 0.135 0.177 3.43 4.5 G 0.098 0.177 3.43 4.5 H 0.118 0.236 3.0 6.0 L 1.130 1.220 28.70 31.0 Typical Weight = 25g Tape and Reel Specification 0.063 MAX" 0.135- 0.145 0.240 ± 0.040 H1 - H2 ± 0.040 -H1-*j U*— H2- _J 0.098- L_ ^1 0.177 L> 0.118- 0.236 -si 1 2.062 2.681 .0.063 MAX 0.02- 0.023 0.200 ±0.020 u 0.080 MAX • Conforms to EIA Standard RS-296E Ordering Information • This series is supplied either in bulk or tape and reel. To order in tape and reel the standard model numbers are changed by replacing the model leter "A" with T". Example: STD. CAT. MODEL ORDER AS V18MA1A V18MT1A Bulk Quantity Per Reel: 5,000 4-73 SEMICONDUCTOR January 1995 Multilayer Surface Mount Transient Surge Suppressors ML SERIES Features • Leadless Chip Form - "Zero" Lead Inductance • Multilayer Construction Technology • -55°C to +125°C Operating Temperature Range • Wide Operating Voltage Range V M(DC) = 3.5V to 68V • Broad Range of Energy Handling Capabilities • Low Profile, Compact Industry Standard Chip Sizes • Inherent Bidirectional Clamping • No Plastic or Epoxy Packaging Assures Better than 94V-0 Flammability Rating • Low Capacitance Models Available Applications • On-Board Transient Voltage Protection for ICs and Transistors • ESD Protection for Components Sensitive to IEC 801-2, MIL-STD-3015.7,etc. • Replace Larger Surface Mount Zener Diodes Description ML series transient surge suppressors are designed to protect sensitive electronic devices from destruction by high voltage transients. These suppressors are designed to fail short when overstressed and protect the associated equipment. The ML suppressor is manufactured from semiconducting ceramics which offer rugged protection, excellent transient energy absorption and increased internal heat dissipation. The devices are in chip form, eliminating lead inductance and assuring fast speed of response to transient surges. These transient suppression devices have significantly smaller footprints and lower profiles than traditional TVS diodes or radial MOV's (metal oxide varistors), thus allowing designers to reduce size and weight while increasing system reliability. Absolute Maximum Ratings For ratings of Individual members of a series, see device ratings and Characteristics chart. ML SERIES UNITS Continuous: Steady State Applied Voltage: DC Voltage Range (V M(DC) ) 3.5 to 68 V AC Voltage Range (V M(AC)RMS ) 2.5 to 50 V Transient: Non-Repetitive Surge Current, 8/20(is Waveform, (I™) 40 to 250 A Non-Repetitive Surge Energy, 1 0/1 OOOjis Waveform, (W TM ) 0.1 to 1 .2 J Operating Ambient Temperature Range (T A ) -55 to +1 25 °C Storage Temperature Range (T STG ) -55 to +150 °C Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Copyright © Harris Corporation 1995 File Number 2461.5 Specifications ML Series Device Ratings and Characteristics MAXIMUM RATINGS (+125°C) CHARACTERISTICS (+25°C) MAXIMUM CONTINUOUS WORKING VOLTAGE MAXIMUM NON- REPETITIVE SURGE CURRENT (8/2U[iS) MAXIMUM NON- REPETITIVE SURGE ENERGY (1U/1UUU(JS) MAXIMUM CLAMPINLi VOLTAGE AT 10A (OR AS NOTED) /own,, »\ NOMINAL VOLTAGE AT 1mA DC TEST CURRENT TYPICAL CAPACITANCE AT * — 1 MU-v MODEL NUMBER V M(DC) V M(AC) Itm W TM v c V N(D c) WIN V N(DC) MAX C (V) (V) (A) (J) (V) (V) (V) (PF) V3.5MLA0805 3.5 2.5 120 0.3 1 at 5A 3.7 5.5 2750 V3.5MLA0805L 3.5 2.5 40 0.1 10at2A 3.7 5.5 1200 V3.5MLA1206 3.5 2.5 100 0.3 14 5.0 7.0 6000 V5.5MLA0805 5.5 4.0 120 0.3 15.5 at 5A 7.1 9.3 2500 V5.5MLA0805L 5.5 4.0 40 0.1 15.5 at 2A 7.1 9.3 1100 V5.5MLA1206 5.5 4.0 150 0.4 15.5 7.1 8.7 4500 V14MLA0805 14 10 120 0.3 30 at 5A 15.9 20.3 1200 V14MLA0805L 14 10 40 0.1 30 at 2A 15.9 20.3 450 V14MLA1206 14 10 150 0.4 30 16.4 20 2100 V18MLA0805 18 14 120 0.3 40 at 5A 22.5 28.0 650 V18MLA0805L 18 14 40 0.1 40 at 2A 22.5 28.0 350 V18MLA1206 18 14 150 0.4 40 22 27 1700 V18MLA1210 18 14 250 0.8 40 22 27 1900 V26MLA1206 26 20 1 50 0.6 56 29.5 38.5 800 V t- Ulvll_r\ \ c.\\J 26 20 250 1.2 54 29.5 38.5 1000 V33MLA1206 33 26 180 0.8 72 38 45 500 V42MLA1206 42 30 180 0.8 86 46 56 450 V56MLA1206 56 40 180 1.0 110 61 76 350 V68MLA1206 68 50 180 1.0 130 76 90 150 NOTES: 1 . L suffix is a low capacitance and energy version. 2. Typical leakage at +25°C < 50|iA, maximum leakage 100nA. 3. Average power dissipation of transients for 0805, 1206 and 1210 sizes not to exceed 0.10W, 0.10W and 0.15W, respectively. 4. Devices specifically characterized for automotive applications also available. (See AUML Series). 4-75 ML Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Characteristics table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. -55 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE Maximum Transient V-l Characteristic Curves CURRENT CURRENT FIGURE 3. V3.5MLA0805/L MAXIMUM V-l CHARACTERISTICS FIGURE 4. V5.5MLA0805/L MAXIMUM V-l CHARACTERISTICS CURVES CURVES 4-76 ML Series Maximum Transient V-l Characteristic Curves (Continued) 10nA 100mA 1mA 10mA 100mA 1A 10A CURRENT FIGURE 5. V14MLA0805/L MAXIMUM V-l CHARACTERISTICS CURVES 10 M A lOO^A 1mA 10mA 100mA 1A CURRENT FIGURE 6. V18MLA0805/L MAXIMUM V-l CHARACTERISTICS CURVES i nun i iinm 1 1 Mm i miiih mint MAXIMUM CLAMPING VOLTAGE 1nA 10nA 100mA 1mA 10mA 100mA 1A 10A 100A CURRENT FIGURE 7. V3.5MLA1206 TO V14MLA1206 MAXIMUM V-l CHARACTERISTIC CURVES 1(iA 10nA 100nA 1mA 10mA 100mA 1A CURRENT 10A 100A FIGURE 8. V18MLA1206 TO V42MLA1206 MAXIMUM V-l CHARACTERISTIC CURVES i mm i ii w ii i i ih f MAXIMUM LEAKAGE V68MLA1206 i i nun i H i m V56MLA1206 10 1(iA 10|iA 100mA 1mA 10mA 100mA 1A 10A 100A CURRENT FIGURE 9. V56MLA1206 TO V68MLA1206 MAXIMUM V-l CHARACTERISTIC CURVE 1MA 10nA 100(iA 1mA 10mA 100mA 1A 10A 100A CURRENT FIGURE 10. V18MLA1210 TO V26MLA1210 MAXIMUM V-l CHARACTERISTIC CURVES 4-77 ML Series Device Characteristics At low current levels, the V-l curve of the multilayer transient voltage suppressor approaches a linear (ohmic) relationship and shows a temperature dependent affect (Figure 11). The suppressor is in a high resistance mode (approaching 10 9 fl) and appears as a near open circuit. This is equivalent to the leakage region in a traditional zener diode. Leakage currents at maximum rated voltage are in the microamp range and in most cases below 50uA. When clamping transients at higher currents, at and above the 10mA range, the multilayer suppressor approaches a 1i2 -10fi characteristic. Here, the multilayer becomes virtu- ally temperature independent (Figure 12). Speed of Response Traditional transient suppressors, e.g. metal oxide varistors and zener diode type devices, have finite lead inductance, device capacitance and resistance. Thus these suppressors have their response times limited (slowed) by parasitic lead impedances. These difficulties have been recognized by the IEEE committees on transient suppressors concluding that response time of a suppressor is influenced by lead configuration and length. Unlike the leaded packages offered for surface mounting (Gull-wing and J-bend) the multilayer suppressor is a true surface mount device. As the multilayer has no leads it therefore has virtually zero inductance and the major factor controlling response time is eliminated. o 8 g Sj U §2 * 25/50 * f 5 /10I 1 ) /125°C 1 1 10"" io-» 10' 7 10" 5 10" 5 10" 4 VARISTOR CURRENT (A DC ) 10- 3 10-* FIGURE 11. TYPICAL TEMPERATURE DEPENDENCE OF THE CHARACTERISTIC CURVE IN THE LEAKAGE REGION V 26MLI 1206 V 5.5ML/ ,1206 -60 -40 -20 20 40 60 80 1 00 1 20 140 TEMPERATURE (°C) FIGURE 12. CLAMPING VOLTAGE OVER TEMPERATURE (V c AT 10A) 4-78 ML Series Energy Absorption/Peak Current Capability This rating serves as a figure of merit for the ML suppressor. Energy is calculated by multiplying the clamping voltage, transient current and transient duration. An important advantage of the multilayer TVS interdigitated construction is its mass of transient suppressor material available to absorb energy. As a result, the peak temperature per energy absorbed is very low. The matrix of semiconducting grains combine to absorb and distribute transient energy (heat) (Figure 13). This dramatically reduces peak temperature, thermal stresses and enhances device reliability. FIRED CERAMIC DIELECTRIC As a measure of the device capability in energy handling and peak current, the V26MLA1206A23 part was tested with multiple pulses at its peak current rating (150A, 8/20 us). As this level of current is far in excess of anything the device is exposed to in an IC protection application it is taken as mea- sure of the ruggedness and inherent capability. At the end of the test, 10,000 pulses later, the device voltage characteris- tics are still well within specification (Figure 14). -METAL ELECTRODES DEPLETION REGION T □□□□□□[ DEPLETION ♦'□□□□□□ora — FIGURE 13. MULTILAYER TVs INTERNAL CONSTRUCTION PEAK CURRENT = 150 A 8/20ms DURATION, 30s BETWEEN PULSES V 26MLA1206 2000 4000 6000 8000 NUMBER OF PULSES FIGURE 14. REPETITIVE PULSE CAPABILITY 4-79 ML Series Soldering Recommendations The principal techniques used for the soldering of components in surface mount technology are Infra Red (IR) Reflow, Vapour Phase Reflow and Wave Soldering. When wave soldering, the ML suppressor is attached to the sub- strate by means of an adhesive. The assembly is then placed on a conveyor and run through the soldering process. With IR and Vapour Phase Reflow the device is placed in a solder paste on the substrate. As the solder paste is heated it reflows, and solders the unit to the board. With the ML suppressor, the recommended solder is a 627 36/2 (Sn/Pb/Ag) silver solder paste. While this configuration is best, a 60/40 (Sn/Pb) or a 63/37 (Sn/Pb) solder paste can also be used. In soldering applications, the ML suppressor is held at elevated temperatures for a relatively long period of time. With the wave soldering operation is the most strenuous of the processes. To avoid the possibility of generating stresses due to thermal shock, a preheat stage in the soldering process is recommended, and the peak tem- perature of the solder process should be rigidly controlled. When using a reflow process, care should be taken to ensure that the ML chip is not subjected to a thermal gradient steeper than 4 degrees per second; the ideal gradient being 2 degrees per second. During the soldering process, preheating to within 100 degrees of the solders peak temperature is essential to minimize thermal shock. Examples of the soldering conditions for the ML series of suppressors are given in the table below. Once the soldering process has been completed, it is still necessary to ensure that any further thermal shocks are avoided. One possible cause of thermal shock is hot printed circuit boards being removed from the solder process and subjected to cleaning solvents at room temperature. The boards must be allowed to cool to less than cleaning. Recommended Pad Outline SOLDERING OPERATION TIME (SECONDS) PEAK TEMPERATURE (°C) IR Reflow 5-10 220 Vapour Phase Reflow 5-10 222 Wave Solder 3-5 260 NOTE 1 : Avoid metal runs in this area. SYMBOL CHIP SIZE 1210 1206 0805 IN MM IN MM IN MM A 0.219 5.53 0.203 5.15 0.105 2.65 B 0.147 3.73 0.103 2.62 0.058 1.45 C 0.073 1.85 0.065 1.65 0.032 0.80 Soldering I Material - 62/36/2 Sn/Pb/Ag or equivalent Temperature - 230°C, 5 seconds max Flux - nonactivated Dimensional Outline SYM- BOL CHIP SIZE 1210 1206 0805 IN MM IN MM IN MM D Max. 0.113 2.87 0.071 1.80 0.043 1.1 E 0.02 ±0.01 0.50 ±0.25 0.02 ±0.01 0.50 ±0.25 0.01 to 0.029 0.25 to 0.75 L 0.125 ±0.012 3.20 ±0.30 0.125 ±0.012 3.20 ±0.03 0.079 ±0.008 2.01 ±0.2 W 0.10 ±0.012 2.54 ±0.30 0.06 ±0.011 1.60 ±0.28 0.049 ±0.008 1.25 ±0.2 4-80 Specifications ML Series Tape and Reel Specifications • Conforms to El A - 481, Revision A • Can be Supplied to IEC Publication 286 - 3 SYMBOL DESCRIPTION MILLIMETERS Ao Width of Cavity Dependent on Chip Size to Minimize Rotation. Bo Length of Cavity Dependent on Chip Size to Minimize Rotation. *o Depth of Cavity Dependent on Chip Size to Minimize Rotation. W Width of Tape 8 ±0.2 F Distance Between Drive Hole Centers and Cavity Centers 3.5 ± 0.5 E Distance Between Drive Hole Centers and Tape Edge 1 .75 ±0.1 Pi Distance Between Cavity Center 4 ±0.1 P 2 Axial Distance Between Drive Hole Centers and Cavity Centers 2 ±0.1 Po Axial Distance Between Drive Hole Centers 4 ±0.1 Do Drive Hole Diameter 1.55 ±0.05 D, Diameter of Cavity Piercing 1.05 ±0.05 <1 Embossed Tape Thickness 0.3 max ts Top Tape Thickness 0.1 max NOTE: Dimensions in millimeters. Ko HI I q:{2 > Q. Standard Packaging The ML Series of transient suppressors are always shipped in tape and reel. The standard 330 millimeter (13 inch) reel utilized contains 8000 pieces for the 1210 and 10000 pieces for the 1206 and 0805 chip. To order add "T23" to the stan- dard part number, e.g. V5.5MLA1206T23 or V68MLA1206T23. Special Packaging Option 1: 178 millimeter (7 inch) reels containing 2000 or 2500, depending on chip size, pieces are available. To order add "H23" to the standard part number, e.g. V5.5MLA1206H23 or V68MLA1206H23. Option 2: For small sample quantities (less than 100 pieces) the units are shipped bulk pack. To order add "A23" to the standard part number, e.g. V5.5MLA1206A23 or V68MLA1206A23. PLASTIC CARRIER TAPE EMBOSSMENT PRODUCT IDENTIFYING LABEL ML Series Terms and Descriptions Rated DC Voltage (V M(DC) ) This is the maximum continuous DC voltage which may be applied up to the maximum operating temperature of the device. The rated DC operating voltage (working voltage) is also used as the reference point for leakage current. This voltage is always less than the breakdown voltage of the device. Unlike the zener diode all multilayer TVS devices have a maximum leakage current of less than 100uA Rated AC Voltage (V M(AC)RMS ) This is the maximum continuous sinusoidal rms voltage which may be applied. This voltage may be applied at any temperature up to the maximum operating temperature of the device. Maximum Non-Repetitive Surge Current (l TM ) This is the maximum peak current which may be applied for an 8/20us impulse, with rated line voltage also applied, with- out causing device failure. The pulse can be applied to the device in either polarity with the same confidence factor. See Figure 2 for waveform description. Maximum Non-Repetitive Surge Energy (W TM ) This is the maximum rated transient energy which may be dissipated for a single current pulse at a specified impulse duration (10/1000us), with the rated DC or RMS voltage applied, without causing device failure. (IJat In the nonconducting mode, the device is at a very high impedance (approaching 10 9 £i) and appears as an almost open circuit in the system. The leakage current drawn at this level is very low (<50uA at ambient temperature) and, unlike the zener diode, the multilayer TVS has the added advan- tage that, when operated up to its maximum temperature, its leakage current will not increase above 500uA. Nominal Voltage (V N(DC) ) This is the voltage at which the device changes from the off state to the on state and enters its conduction mode of oper- ation. The voltage is usually characterized at the 1 mA point and has a specified minimum and maximum voltage listed. Clamping Voltage (V c ) This is the peak voltage appearing across the suppressor when measured at conditions of specified pulse current and specified waveform (8/20us). It is important to note that the peak current and peak voltage may not necessarily be coin- cidental in time. Capacitance (C) This is the capacitance of the device at a specified fre- quency (1MHz) and bias (1V P . P ). 4-82 33 h MICONDUCTOR NA Series March 1995 Industrial High Energy Metal-Oxide Square Varistors NA SERIES Features • Provided Unpackaged For Unique Packaging By Customer • Solderable Electrode Finish Also Provides Pressure Contacts for Stacking Applications • Wide Operating Voltage Range V M(AC)RMS 130V to 750V • Peak Pulse Current Capability l TM 40, 000 A • High Energy Capability W™ Description NA series transient surge suppressors are industrial high- energy square varistors intended for special applications requiring unique contact or packaging considerations. The electrode finish of these devices is solderable and can also be used as pressure contacts for stacking applications. These NA series industrial square varistor is available as a 34mm device, with thicknesses ranging from 1.8mm mini- mum for the 1 30V device to 8.3mm maximum for the 750V device. For information on mounting considerations refer to Application Note AN8820. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart NA SERIES Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 130 to 750 DC Voltage Range (V M(DC) ) 1 75 to 970 Transient: Peak Pulse Current (Ijm) For 8/20ps Current Wave (See Figure 2) 40,000 Single Pulse Energy Range For 1 0/1 000ms Current Wave (Wtm) 270 to 1 050 Operating Ambient Temperature Range (T A ) -55 to +85 Storage Temperature Range (T STG ) -55 to +125 Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 UNITS V V A J °C °C %/°C Copyright © Harris Corporation 1995 4-83 File Number 2825.3 Specifications NA Series Device Ratings and Specifications MODEL NUMBER SIZE MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1 mA DC TEST CURRENT MAXIMUM CLAMPING VOLTAGE (Vc) AT 200A (8/20us) TYPICAL CAPACI- TANCE "RMS Vnr ENERGY (2ms) PEAK CURRENT (8/20us) V M(AC) V M(DC) Itu 'TM MIN V N(DC) MAX V c f = 1MHz (mm) (V) (V) (V) (A) (V) (V) (V) (V) (pF) V131NA34 34 130 175 270 30,000 184 200 228 345 10,000 V151NA34 34 150 200 300 30.000 212 240 268 405 8,000 V251NA34 34 250 330 370 40,000 354 390 429 650 5,000 V271 NA34 34 275 369 400 40,000 389 430 473 730 4,500 V321NA34 34 320 420 460 40,000 462 510 539 830 3,800 V421NA34 34 420 560 600 40,000 610 680 748 1,130 3,000 V481NA34 34 480 640 650 40,000 670 750 825 1,240 2,700 V511NA34 34 510 675 700 40,000 735 820 910 1,350 2,500 V571NA34 34 575 730 770 40,000 805 910 1000 1,480 2,200 V661 NA34 34 660 850 900 40,000 940 1050 1160 1,720 2,000 V751NA34 34 750 970 1050 40,000 1080 1200 1320 2,000 1,800 Average power dissipation of transients not to exceed 2.0W. ■ Power Dissipation Ratings Continuous power dissipation capability is not an applicable requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. CURVE 4-84 -55 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING NA Series O, = Virtual Origin of Wave T - Time From 1 0% to 90% of Peak T, = Virtual Front Time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20us Current Waveform: 8ms = T, I 20ns = T 2 = Virtual Front Time Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curve g > M £ 1,0i 100 100 1,000 FIGURE 3. CLAMPING VOLTAGE FOR V131NA34 - V751NA34 10E-3 10E-2 10E-1 1 10 PEAK AMPERES (A) Pulse Rating Curves 100 1,01 IMPULSE DURATION ( M s) FIGURE 4. SURGE CURRENT RATING CURVES FOR V251NA34-V751NA34 10,000 100 1,000 IMPULSE DURATION (ps) FIGURE 5. SURGE CURRENT RATING CURVES FOR V131NA34, V151NA34 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than +10% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-85 NA Series Series Outline Dimensions R B.B5 ± 0.2 THICKNESS - SEE TABLE NA SERIES VARISTOR THICKNESS MODEL MILLIMETERS INCHES NUMBER MIN MAX MIN MAX V131NA34 1.40 2.30 0.055 0.090 V151NA34 1.70 2.80 0.067 0.011 V251NA34 2.00 2.70 0.079 0.106 V271NA34 2.20 3.00 0.087 0.118 V321NA34 2.60 3.50 0.102 0.138 V421NA34 3.50 4.70 0.138 0.185 V481NA34 3.80 5.20 0.150 0.205 V511NA34 4.20 5.70 0.165 0.225 V571NA34 4.60 6.30 0.181 0.248 V661NA34 5.30 7.20 0.209 0.284 V7S1NA34 6.10 8.30 0.240 0.327 NOTE: Parts available encapsulated with soldered tabs, to standard design or customer specific requirements. 4-86 SI SEMICONDUCTOR PA Series March 1995 Base Mount Metal-Oxide Varistors PA SERIES Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 toStd. 1449 • Recognized as "Transient Voltage Surge Suppressors", CSA File #LR91788 to Std. C22.2 No. 1-M1981 • Wide Operating Voltage Range V M(AC)RMS 130V to 660V • Creep and Strike Distance Capability Meets Rigid NEMA Standards • Base Mount Construction for Rigid Mounting Applications • Quick Connect Tab Terminal Description PA series transient surge suppressors are base mount metal-oxide varistors featuring rigid mountdown con- struction, and are useful in applications which are critical to vibration. These UL and CSA recognized varistors are available in a wide range of operating voltages, from 130V to 660V V M(AC)RMS- Tne base-mount package has a quick connect tab terminal that provides a fast secure lead mount. Meeting rigid NEMA standards, PA series varistors have a creep and strike distance capability that minimizes breakdown along the package surface. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart PA SERIES UNITS Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 130 to 660 V DC Voltage Range (V M(DC) ) 1 75 to 850 V Transient: Peak Pulse Current (l TM ) For 8/20(is Current Wave (See Figure 2) 6500 A Single Pulse Energy Range For 1 0/1 OOOtis Current Wave (W TM ) 70 to 250 J Operating Ambient Temperature Range (T A ) -55 to +85 °C Storage Temperature Range (T STG ) -55 to +125 °C Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Copyright © Harris Corporation 1995 4-87 File Number 2192.3 PA Series Device Ratings and Specifications Series PA Varistors are listed under UL file #E75961 and under CSA file #I_R91788, as a UL recognized component. MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT MAX CLAMPING V RMS Vdc ENERGY (10/ 1000ms) PEAK CURRENT (8/20iis) VARISTOR VOLTAGE AT 1mA DC TEST CURRENT VOLT V c AT TEST CURRENT (8/20us) TYPICAL CAPACI- TANCE MODEL V H(AC) V M(DC) w™ 'tm MIN Vn(dc) MAX Vc f = 1MHz NUMBER (V) (V) (J) (A) ( v ) (V) (V) (V) (pF) V130PA20A 130 175 70 6500 184 200 243 360 100 1900 V130PA20C 130 175 70 6500 184 200 220 325 100 1900 V150PA20A 150 200 80 6500 212 240 284 420 100 1600 V150PA20C 150 200 80 6500 212 240 243 360 100 1600 V250PA40A 250 330 130 6500 354 390 453 675 100 1000 V250PA40C 250 330 130 6500 354 390 413 620 100 1000 V275PA40A 275 369 140 6500 389 430 494 740 100 900 V275PA40C 275 369 140 6500 389 430 453 680 100 900 V320PA40A 320 420 160 6500 462 510 565 850 100 750 V320PA40C 320 420 160 6500 462 510 540 800 1 00 750 V420PA40A 420 560 170 6500 610 680 790 1160 100 600 V420PA40C 420 560 170 6500 610 680 690 1050 100 600 V480PA80A 480 640 180 6500 670 750 860 1280 100 550 V480PA80C 480 640 180 6500 670 750 790 1160 100 550 V510PA80A 510 675 190 6500 735 820 963 1410 100 500 V510PA80C 510 675 190 6500 735 820 860 1280 100 500 V575PA80A 575 730 220 6500 805 910 1050 1560 100 450 V575PA80C 575 730 220 6500 805 910 960 1410 100 450 V660PA100A 660 850 250 6500 940 1050 1210 1820 100 400 V660PA100C 660 850 250 6500 940 1050 1100 1650 100 400 NOTE: Average power dissipation of transients not to exceed 1 W. Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. -it- SB 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE PA Series O, = Virtual Origin of Wave T = Time From 1 0% to 90% of Peak T, = Virtual Front Time = 1.25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20us Current Waveform: 8us = T, = Virtual Front Time 20us = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves V320PA40A 6,000 5,000 4,000 3,000 10-' 10" 2 10 1 10° 10 1 10 2 1 3 1 4 PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V130PA20A - V660PA100A rr « > Q. 10° 10 1 10 2 PEAK AMPERES (A) FIGURE 4. CLAMPING VOLTAGE FOR V130PA20C - V660PA100C Pulse Rating Curves FIGURE 5. SURGE CURRENT RATING CURVES FOR FIGURE 6. SURGE CURRENT RATING CURVES FOR V130PA20A - V320PM0C V420PA40A - V660PA100C NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±10% could result. This type of shift, which normally results in a decrease of V N(CC ), may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide transient protection. 4-89 PA Series Package Outline Dimensions NOTES: 1 . Tab is designed to fit 1/4" quick-connect terminal. 2. Case temperature is measured at T c on top surface of base plate. 3. H, (1 30-1 50V RMS devices) H 2 (250-320V RMS devices) H 3 (420-660V BMS devices) 4. Electrical connection: top terminal and base plate. 5. Typical weight: 30g MILLIMETERS INCHES SYMBOL MIN NOM MAX MIN NOM MAX NOTES A 14.3 - - 0.570 - b 6.6 . - 0.260 1 b2 3.94 4.06 4.18 0.155 0.160 0.165 b3 3.05 3.17 3.29 0.120 0.125 0.130 B 0.510 C 6.6 . 0.260 D _ 66.3 2.610 0D1 _ 33.5 1.320 E 11.2 : 0.440 F 7 50 7.62 7.75 295 0.300 0.305 h 0.8 1.0 0.030 0.040 _ H, 25.6 1.010 3 H 2 28.3 1.120 3 H 3 32.8 1.290 3 J 8.1 0.320 0P 5.6 6.0 0.220 0.240 Q 50.6 50.8 51.0 1.990 2.000 2.010 S 18.4 19.2 20.0 0.72 0.75 0.78 T 1.0 0.040 0T 2.8 0.110 Tc 3.2 0.126 2 Suggested Hardware and Mounting #10-32 PAN HEAD SCREW #10 FLAT WASHER VARISTOR MOUNTING SURFACE LOCK WASHER #10-32 NUT THERMAL QUICK CONNECT (D THERMAL GREASE LAYER Typical Non-Isolated Mounting NOTES: 1. GE G623. Dow Corning, DC3, 4, 340, or 640 Thermal Grease recommended for best heat transfer. 2. 1 ,000V isolation kit containing the following parts can be ordered by part #A781 1055. tern #6-32 SCREW #6 FLAT WASHER PHENOLIC SHOULDER WASHER SPACER VARISTOR MICA INSULATOR MOUNTING SURFACE LOCK WASHER Typical Isolated Mounting 1. MICA insulation 173.170.005" thick 2. Phenolic shoulder washer 1. Spacer 2. #6-32/ 3 / 4 screw 2. #6-32 nut 2. #6 internal tooth lock washer 2. #6 flat washer 4-90 33 SEMICONDUCTOR March 1995 Low Profile Metal-Oxide Varistors RA SERIES Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E75961 to Std. 1449 • Recognized as "Transient Voltage Surge Suppressors", CSA File #LR91788 to Std. C22.2 No. 1-M1981 • Recognized as "Across-The-Line Components", UL File #E56529 to Standard 1414 • Recognized as "Protectors for Data communication and Fire Alarm Circuits", UL File #E1 35010 to Standard 497B • Low Profile Outline with Precise Seating Plane • Continuous Temperature Operation +125°C • Wide Operating Voltage Range V M(AC)RMS 275V • High Energy Absorption Capability W TM upto140J • 3 Model Sizes Available RA8, RA16, and RA22 • In-Line Leads for Ease in Automatic Placement Description RA series transient surge suppressors are low profile radial lead varistors that feature a precise seating plane to increase mechanical stability for secure circuit-board mount- ing. This feature makes these devices suitable for industrial applications critical to vibration. The RA series are available in voltage ratings up to 275V V M(AC)RMS' and energy levels up to 140J. Supplied in tape and reel for use with automatic insertion equipment, these varistors are also used in automotive, motor-control, tele- communication, and military applications. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart RA8 SERIES Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 4 to 275 DC Voltage Range (V M(DC ) 5.5 to 369 Transient: Peak Pulse Current (l TM ) For 8/20u.s Current Wave (See Figure 2) 1 00 to 1 200 Single Pulse Energy Range (Note 1 ) For 1 0/1 000|!S Current Wave (W TM ) 0.4 to 23 Operating Ambient Temperature Range 0a) -55 to +1 25 Storage Temperature Range (T STG ) -55 to +1 50 Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 Hi-Pot Encapsulation (Isolation Voltage Capability) 5000 (Dielectric must withstand indicated DC voltage for one minute per Mll-STO 202, Method 301) Insulation Resistance 1000 RA16 SERIES 10 to 275 14 to 369 1000 to 4500 3.5 to 75 -55 to +125 -55 to +150 <0.01 5000 1000 RA22 SERIES UNITS 4 to 275 18 to 369 2000 to 6500 70 to 160 -55 to +125 -55 to +150 <0.01 5000 1000 J °C °C %/°C V Mn Copyright © Harris Corporation 1 995 4-91 File Number 2193.3 Specifications RA Series Device Ratings and Specifications (Note 1) RA8 Series Series RA8 Varistors of 130V RMS or greater are listed under UL File No. E75961 as a recognized component. CSA approved File No. LR91788. MODEL NUMBER MAXIMUM RATINGS (+125°C) SPECIFICATIONS (+25°C) DEVICE MARK- ING CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT MAX CLAMPING VOLTAGE V c AT TEST CURRENT (8/20us) TYPICAL CAPACI- TANCE V RMS ENERGY (10/ PEAK CURRENT V V M(DC) W 1 'TM MIN V N(DC) MAX Vc lp f = 1MHz / n W) w (V) (V) (V) (V) (A) (dF) IK* 1 V8RA8 8R 4 5.5 0.4 1 50 6 8.2 11.2 22 5 3000 V12RA8 12R 6 8 0.6 1 50 9 12 16 34 5 2500 V18RA8 18R 10 14 0.8 250 14.4 18 21.6 42 5 2000 V22RA8 22 R 14 18 (Note 3) 10 (Note 2) 250 18.7 22 26 47 5 1 600 V27RA8 27R 17 22 1.0 250 23 27 31 .1 57 5 1300 V33RA8 33R 20 26 1.2 250 29.5 33 36.5 68 5 1100 V39RA8 39R 25 31 1.5 250 35 39 43 79 5 900 V47RA8 47R 30 38 1.8 250 42 47 52 92 5 800 V56RA8 56R 35 45 2.3 250 50 56 62 107 5 700 V68RA8 68R 40 56 3.0 250 61 68 75 1 27 5 600 V82RA8 82 R 50 66 4.0 1200 74 82 91 135 10 500 V100RA8 100R 60 81 5.0 1200 90 100 110 165 10 400 V120RA8 120R 75 102 6.0 1200 108 120 132 205 10 300 V150RA8 150R 95 127 8.0 1200 135 150 165 250 10 250 V180RA8 180R 115 153 10.0 1200 162 180 198 295 10 200 V200RA8 200 R 130 175 11.0 1200 184 200 228 340 10 180 V220RA8 220 R 140 180 12.0 1200 198 220 242 360 10 160 V240RA8 240 R 150 200 13.0 1200 212 240 268 395 10 150 V270RA8 270R 175 225 15.0 1200 247 270 303 455 10 130 V360RA8 360 R 230 300 20.0 1200 324 360 396 595 10 100 V390RA8 390 R 250 330 21.0 1200 354 390 429 650 10 90 V430RA8 430R 275 369 23.0 1200 389 430 473 710 10 80 NOTES: 1 . Average power dissipation of transients not to exceed 0.25W for RA8 Series. 2. Energy ratings for impulse duration of 30ms minimum to one half of peak current value. 3. Also rated to withstand 24V for 5 minutes. Specifications RA Series Device Ratings and Specifications (Note 1) (Continued) RA16 Series Series RA16 and RA22 Varistors of 130V RMS or greater are listed under UL File No. E75961 as a recognized component. CSA approved File No. LR91788. MODEL NUMBER MAXIMUM RATINGS (+125°C) SPECIFICATIONS (+25°C) DEVICE MARK- ING CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1mA DC TEST CURRENT MAX CLAMPING VOLTAGE V c AT TEST CURRENT (8/20ns) TYPICAL CAPACI- TANCE u V RMS "DC ENERGY (107 PEAK CURRENT V M(AC) V M(DC) III "TM MIN V N(DC) MAX Vc Ip f = 1MHz ( v ) ( V ) ( J ) (A) (V) (V) (V) (V) (A) (Pn 18R16 10 14 3.5 1000 14.4 18 21.6 39 10 1 1 000 V ttnn 1 U 22R16 14 1 8 (Note 3) 50 (Note 2) 1000 18.7 22 26 43 10 9000 V27RA16 27R16 17 22 5.0 1000 23 27 31.1 53 10 7000 V33RA16 33R16 20 26 6.0 1000 29.5 33 36.5 64 10 6000 V39RA16 39R16 25 31 7.2 1000 35 39 43 76 10 5000 V47RA16 47R16 30 38 8.8 1000 42 47 52 89 10 4500 V56RA16 56R16 35 45 10.0 1000 50 56 62 103 10 3900 V68RA16 68R16 40 56 13.0 1000 61 68 75 123 10 3300 V82RA16 82R16 50 66 15.0 4500 74 82 91 145 50 2500 V100RA16 100R16 60 81 20.0 4500 90 100 110 175 50 2000 V120RA16 120R16 75 102 22.0 4500 108 120 132 205 50 1700 V150RA16 150R16 95 127 30.0 4500 135 150 165 255 50 1400 V180RA16 180R16 115 153 35.0 4500 162 180 198 300 50 1100 V200RA16 200R16 130 175 38.0 4500 184 200 228 340 50 1000 V220RA16 220R16 140 180 42.0 4500 198 220 242 360 50 900 V240RA16 240R16 150 200 45.0 4500 212 240 268 395 50 800 V270RA16 270R16 175 225 55.0 4500 247 270 303 455 50 700 V360RA16 360R16 230 300 70.0 4500 324 360 396 595 50 550 V390RA16 390R16 250 330 72.0 4500 354 390 429 650 50 500 V430RA16 430R16 275 369 75.0 4500 389 430 473 710 50 450 RA22 Series V24RA22 24R22 14 18 (Note 3) 100.0 (Note 2) 2000 19.2 24 (Note 4) 26 43 20 18000 V36RA22 36R22 23 31 160.0 (Note 2) 2000 32 36 (Note 4) 40 63 20 12000 V200RA22 200R22 130 175 70.0 6500 184 200 228 340 100 1900 V240RA22 240R22 150 200 80.0 6500 212 240 268 395 100 1600 V270RA22 270R22 175 225 90.0 6500 247 270 303 455 100 1400 V390RA22 390R22 250 330 130.0 6500 354 390 429 650 100 1000 V430RA22 430 R22 275 369 140.0 6500 389 430 473 710 100 900 NOTES: 1 . Average power dissipation of transients not to exceed 0.60W for RA1 6 Series, or 1 .0W for RA22 Series. 2. Energy ratings for impulse duration of 30ms minimum to one half of peak current value. 3. Also rated to withstand 24V for 5 minutes. 4. 10mA DC Test Current. 4-93 RA Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power c 100 u 90 < 60 70 Ul 1 60 cc 50 £ 40 m O 30 £ 20 10 -55 50 60 70 60 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8(is = T, = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves 10' 1 10" 10 1 PEAK AMPERES (A) MAXIMUM CLAMPING VOLTAGE MODEL SIZE 5 x 8mm 82 TO 430V N(DC) RATING T. = -55°CTO+125°C .000 900 800 700 600 500 400 V360RA8 V270RA8 I I I 111 200 V180RA8 V150RA8 V120RA8 V100RA8 100 i — i 1 1 1 mi 300 , 10 3 10- 2 FIGURE 3. CLAMPING VOLTAGE FOR V8RA8 - V68RA8 10° 10 1 PEAK AMPERES (A) FIGURE 4. CLAMPING VOLTAGE FOR V82RA8 - V430RA8 4-94 RA Series Transient V-l Characteristics Curves (Continued) 10-' 10° 10 1 PEAK AMPERES (A) FIGURE 5. CLAMPING VOLTAGE FOR V18RA16 - V68RA16 10- 1 10° 10 1 10 2 10 3 10* PEAK AMPERES (A) FIGURE 6. CLAMPING VOLTAGE FOR V82RA16 - V430RA16 10* 10- 1 10° 10 1 10 2 1 3 1 4 PEAK AMPERES (A) FIGURE 7. CLAMPING VOLTAGE FOR V24RA22 - V36RA22 4,000 3,000 2,000 MAXIMUM CLAMPING VOLTAGE 200 TO 430V K(Dcl RATING T A = -55°CTO+125°C 5 ° 10"' 10° 10 1 10* 10 3 10 4 PEAK AMPERES (A) FIGURE 8. CLAMPING VOLTAGE FOR V200RA22 - V430RA22 Pulse Rating Curves 200 100 1,000 IMPULSE DURATION (us) FIGURE 9. SURGE CURRENT RATING CURVES FOR V8RA8 - V12RA8 100 1,000 IMPULSE DURATION (us) 10,000 FIGURE 1 0. SURGE CURRENT RATING CURVES FOR V1 8RA8 - V68RA8 4-95 RA Series Pulse Rating Curves (Continued) 20 100 1,000 10,000 IMPULSE DURATION ((is) FIGURE 1 1 . SURGE CURRENT RATING CURVES FOR V82RA8 - V430RA8 20 100 1,000 10,000 IMPULSE DURATION ((is) FIGURE 12. SURGE CURRENT RATING CURVES FOR V18RA16 -V68RA16 100 1,0 IMPULSE DURATION (us) 10,000 FIGURE 13. SURGE CURRENT RATING CURVES FOR V82RA16 -V430RA16 100 1,000 IMPULSE DURATION (us) FIGURE 14. SURGE CURRENT RATING CURVES FOR V24RA22 - V36RA22 100 1,000 10,000 IMPULSE DURATION ( M s) FIGURE 15. SURGE CURRENT RATING CURVES FOR V200RA22 - V430RA22 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±1 0% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-96 RA Series Pa, -DMAX- mensions — bYMbUL RA8 SERIES RA16 CCDICC bbnlbb RA22 SERIES A MAX 8.85 (0.348) 15.1 (0.594) 19.1 (0.752) D MAX 11.45 (0.450) 19.7 (0.776) 25.5 (1 .004) e 5 (0.197) 7.5 (0.295) 7.5 (0.295) E MAX 5.2 (0.205) 6.3 (0.248) 6.3 (0.248) n MAX 0.7 (0.027) 0.7 (0.027) 0.7 (0.027) 0b 0.635 (0.025) 0.81 (0.032) 0.81 (0.032) WEIGHT TYP 1 Gram 3.4 Grams 4.4 Grams X 2.2 (0.087) 2.2 (0.087) 4.4 (0.173) Y 3.1 ±0.5 (0.122 + 0.02) 6±1 (0.236 ±0.04) 8.9 ± 1 (0.35 ± 0.04) NOTES: 1. Dimensions in mm, dimensions in inches in parentheses. 2. Inches for reference only. S3 ! June 1995 EMICONDUCTOR Radial Lead Metal-Oxide Varistors for Low-to-Medium Voltage Operation S, 7,10,14,20mm ZA SERIES Features • Recognized as "Transient Voltage Surge Suppressors", UL File #E1 35010 to Std. 497B • Wide Operating Voltage Range V M(AC)RMS 4V to 460V • DC Voltage Ratings 5.5V to 615V • 5 Model Sizes Available 5, 7, 10, 14, and 20mm • Radial-Lead Package for Compact Hard-Wired Printed Circuit Board Designs • Available in Tape and Reel for Use With Automatic Insertion Equipment Description The ZA series of transient voltage surge suppressors are radial-lead varistors designed for use in the protection of low and medium-voltage circuits and systems. Typical applica- tions include motor control, telecom, automotive systems, solenoid, and power supply circuits to protect circuit board components and maintain data integrity. These devices are available in five model sizes: 5mm, 7mm, 10mm, 14mm and 20mm, and feature a wide V DC voltage range of 5.5V to 615V. Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart ZA SERIES UNITS Continuous: Steady State Applied Voltage: AC Voltage Range (V M(AC)RMS ) 4 to 460 V DC Voltage Range (V M(DC) ) 5.5 to 61 5 V Transient: Peak Pulse Current (l TM ) For 8/20ps Current Wave (See Figure 2) 50 to 6500 A Single Pulse Energy Range (Note 1) For 1 0/1 000ms Current Wave (Wjm) 0.1 to 52 J Operating Ambient Temperature Range (T A ) -55 to +85 °C Storage Temperature Range (Tstq) -55 to +125 °C Temperature Coefficient (aV) of Clamping Voltage (V c ) at Specified Test Current <0.01 %/°C Hi-Pot Encapsulation (Isolation Voltage Capability) 2500 V (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) . Insulation Resistance 1000 MC2 Copyright © Harris Corporation 1995 4-98 File Number 2184.3 Specifications ZA Series Device Ratings and Specifications (Note 1) ZA Series Varistors are listed under UL File No. E135010 as a UL recognized component. MAXIMUM RATING (85°C) SPECIFICATIONS (25°C) CONTINUOUS TRANSIENT MAXIMUM TYPICAL MODEL SIZE DISC Vrms Vdc ENERGY 10 x 1000ns PEAK CURRENT 8 X 20ns VARISTOR VOLT- AGE AT 1mA DC TEST CURRENT CLAMPING VOLTAGE a x 20ns CAPACI- TANCE f = 1MHz MODEL DEVICE V M(AC) V M(DC) W TM I™ V NOM MIN V NOM MAX V C IRK C NUMBER DIA. (mm) MARKING (V) (V) (J) (A) (V) (V) (A) (PF) V8ZA05 5 Z08 4 5.5 0.1 50 6 11 30 i 1400 V8ZA1 7 08Z1 4 5.5 0.4 100 6 11 22 2.5 3000 V8ZA2 10 08Z2 4 5.5 0.8 250 6 11 20 5 7500 V12ZA05 5 Z12 6 8 0.14 50 9 16 37 1 1200 V12ZA1 7 12Z1 6 8 0.6 100 9 16 34 2.5 2500 V12ZA2 10 12Z2 6 8 1.2 250 9 16 30 5 6000 V18ZA05 5 Z18 10 14 0.17 100 14.4 21.6 36 1 1000 V18ZA1 7 18Z1 10 14 0.8 250 14.4 21.6 36 2.5 2000 V18ZA2 10 18Z2 10 14 1 t; 1 .0 duu 14.4 21.6 36 5 5000 V18ZA3 14 18Z3 1 ft 14 3.5 1000 14.4 21.6 36 10 11000 V18ZA40 20 18Z40 iu 14 80 (Note 2) 2000 14.4 (Note 3) 21.6 37 20 22000 V22ZA05 5 Z22 14 18 0.2 100 18.7 26 43 1 800 V22ZA1 7 22Z1 14 18 0.9 250 18.7 26 43 2.5 1600 V22ZA2 10 22Z2 14 18 2 DUU 18.7 26 43 5 4000 V22ZA3 14 22Z3 14 18 4 1000 18.7 26 43 10 9000 V24ZA50 20 24Z50 14 t«t 1 8 (Note 4) 1 UU (NOte £.) 2000 19.2 (Note 3) 26 43 20 15000 V27ZA05 5 Z27 17 22 0.25 100 23 31.1 53 1 600 V27ZA1 7 27Z1 17 22 1 250 23 31.1 53 2.5 1300 V27ZA2 10 27Z2 17 22 2.5 500 23 31.1 53 5 3000 V27ZA4 14 27Z4 17 22 5 1000 23 31.1 53 10 7000 V27ZA60 20 27Z60 17 22 120 (Note 2) 2000 23 (Note 3) 31.1 50 20 13000 V33ZA05 5 Z33 20 26 3 100 29.5 38 65 1 500 V33ZA1 7 33Z1 20 26 1.2 250 29.5 36.5 65 2.5 1 100 V33ZA2 10 33Z2 20 26 3 500 29.5 36.5 65 5 2700 V33ZA5 14 33Z5 20 26 6 1000 29.5 36.5 65 10 6000 V33ZA70 20 33Z70 21 27 150 (Note 2) 2000 29.5 (Note 3) 36.5 58 20 13000 V36ZA80 20 36Z80 23 31 160 (Note 2) 2000 32 (Note 3) 40 63 20 12000 V39ZA05 5 Z39 25 31 0.3 100 35 46 79 1 500 V39ZA1 7 39Z1 25 31 1.2 250 35 43 79 2.5 1100 V39ZA3 10 39Z3 25 31 3 500 35 43 76 5 2700 V39ZA6 14 39Z6 25 31 6 1000 35 43 76 10 6000 V39ZA20 20 39Z20 25 31 20 2000 35 43 76 20 12000 4-99 Specifications ZA Series Device Ratings and Specifications (Note 1) (Continued) ZA Series Varistors are listed under UL File No. E1 35010 as a UL recognized component. MAXIMUM RATING (85°C) SPECIFICATIONS (25°C) CONTINUOUS TRANSIENT MAXIMUM TYPICAL MODEL SIZE DISC V RMS Vdc ENERGY 10 x 1000ns PEAK CURRENT 8 X 20us VARISTOR VOLT- AGE AT 1mA DC TEST CURRENT CLAMPING VOLTAGE 8 x 20us CAPACI- TANCE f = 1MHz MODEL DEVICE V M(AC) V M(DC) W TM Itm Vnom MIN V NOM MAX v c C NUMBER DIA. (mm) MARKING (V) (V) (J) (A) (V) (V) (A) (pF) V47ZA05 5 Z47 30 38 0.4 100 42 55 93 1 400 V47ZA1 7 47Z1 30 38 1.8 250 42 52 93 2.5 800 V47ZA3 10 47Z3 30 38 4.5 500 42 52 93 5 2000 V47ZA7 14 47Z7 30 38 8.8 1000 42 52 93 10 4500 V47ZA20 20 47Z20 30 38 23 2000 42 52 93 20 11000 V56ZA05 5 Z56 35 45 0.5 100 50 66 110 1 360 V56ZA2 7 56Z2 35 45 2.3 250 50 62 110 2.5 700 V56ZA3 10 56Z3 35 45 5.5 500 50 62 110 5 1800 V56ZA8 14 56Z8 35 45 10 1000 50 62 110 10 3900 V56ZA20 20 56Z20 35 45 30 2000 50 62 110 20 10000 V68ZA05 5 Z68 40 56 0.6 100 61 80 135 1 300 V68ZA2 7 68Z2 40 56 3 250 61 75 135 2.5 600 V68ZA3 10 68Z3 40 56 6.5 500 61 75 135 5 1500 V68ZA10 14 68Z10 40 56 13 1000 61 75 135 10 3300 V68ZA20 20 68Z20 40 56 33 2000 61 75 135 20 10000 V82ZA05 5 Z82 50 68 2 400 73 97 135 5 240 V82ZA2 7 82Z2 50 68 4 1200 73 91 135 10 500 V82ZA4 10 82Z4 50 68 8 ~y 2500 73 91 135 25 1100 V82ZA12 14 82Z12 50 68 15 4500 73 91 145 50 2500 V100ZA05 5 Z100 60 81 2.5 400 90 117 165 5 180 V100ZA3 7 100Z 60 81 5 1200 90 110 165 10 400 V1 00ZA4 10 100Z4 60 81 10 2500 90 110 165 25 900 V100ZA15 14 60 81 20 4500 90 110 175 50 2000 V120ZA05 5 Z120 75 02 3 400 108 138 205 5 140 V120ZA1 7 120Z 75 02 6 1200 108 132 205 10 300 V120ZA4 10 120Z4 75 02 12 2500 108 132 200 25 750 VI <;UZAb 14 120Z6 75 02 22 4500 108 132 210 50 1700 V120ZA20 20 120Z20 75 02 33 6500 108 132 210 100 1500 V150ZA05 5 Z150 92 127 4 400 135 173 250 5 120 V150ZA1 7 Z051 95 127 8 1200 135 165 250 10 250 V150ZA4 10 150Z4 95 127 15 2500 135 165 250 25 600 V150ZA8 14 150Z8 95 127 20 4500 135 165 250 50 1400 V150ZA20 20 150Z20 95 127 45 6500 135 165 250 100 1000 4-100 Specifications ZA Series Device Ratings and Specifications (Note 1) (Continued) ZA Series Varistors are listed under UL File No. E135010 as a UL recognized component. MAXIMUM RATING (85°C) SPECIFICATIONS (25°C) CONTINUOUS TRANSIENT MAXIMUM TYPICAL PEAK VARISTOR VOLT- CLAMPING CAPACI- ENERGY f* 1 innr.iT CUHHbN 1 AGE AT 1mA DC VOLTAGE TANCE MODEL SIZE DISC V RMS v DC 10 x 1000ns 8 x 20us TEST CURRENT 8 x 20us f = 1MHz MODEL DEVICE V M(AC) V M(DC) W TM I™ V NOM MIN Vnom MAX Vc ■PK C NUMBER DIA. (mm) MARKING (V) (V) (J) (A) (V) (V) (A) (pF) V180ZA05 5 Z180 110 153 5 400 162 207 295 5 100 V180ZA1 7 180Z 115 153 10 1200 162 198 300 10 200 V180ZA5 10 180Z5 115 153 18 2500 162 198 300 25 500 V180ZA10 14 180Z10 115 153 35 4500 162 198 300 50 1100 V1 80ZA20 20 180Z20 115 153 52 6500 162 198 300 100 2400 V205ZA05 5 Z205 130 170 5.5 400 184 226 340 5 100 V220ZA05 5 Z220 140 180 6 400 198 253 360 5 90 V240ZA05 c Z240 150 200 7 400 216 264 395 5 80 V270ZA05 5 Z270 175 225 7.5 400 243 311 455 5 70 V330ZA05 5 Z330 210 275 9 400 297 380 540 5 60 V360ZA05 5 Z360 230 300 9.5 400 324 396 595 5 55 V390ZA05 5 Z390 250 330 10 400 351 449 650 5 50 V430ZA05 5 Z430 275 369 11 400 387 495 710 5 45 V470ZA05 5 Z470 300 385 12 400 420 517 775 5 35 V620ZA05 5 Z620 385 505 13 400 558 682 1025 5 33 V680ZA05 5 Z680 420 560 14 400 610 748 1120 5 32 V715ZA05 5 Z715 440 585 15.5 400 643 787 1180 5 31 V750ZA05 5 Z750 460 615 17 400 675 825 1240 5 30 NOTES: 1 . Average power dissipation of transients not to exceed 0.2W, 0.25W, 0.4W, 0.6W or 1 W for model sizes 5mm, 7mm, 1 0mm, 1 4mm and 20mm, respectively. 2. Energy rating for impulse duration of 30ms minimum to one half of peak current. 3. 10mA DC test current. 4. Also rated to withstand 24V for 5 minutes. 5. Higher voltages available, contact Harris Semiconductor Power Marketing. 4-101 ZA Series Power Dissipation Ratings Continuous power dissipation capability is not an applicable design requirement for a suppressor, unless transients occur in rapid succession. Under this condition, the average power dissipation required is simply the energy (watt-seconds) per pulse times the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings and Specifications table for the specific device. Furthermore, the operating values need to be der- ated at high temperatures as shown in Figure 1. Because varistors can only dissipate a relatively small amount of average power they are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation. 100 |-$. 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 1. CURRENT, ENERGY AND POWER DERATING CURVE O, = Virtual Origin of Wave T = Time From 1 0% to 90% of Peak T, = Virtual Front time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8(is = Ti = Virtual Front Time 20ns = T 2 = Virtual Time to Half Value FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM Transient V-l Characteristics Curves 10" 1 10° 10 1 PEAK AMPERES (A) FIGURE 3. CLAMPING VOLTAGE FOR V8ZA05 - V68ZA05 I £ 500 100 0.0001 0.001 MAX CLAMPING VOLTAGE MODEL SIZE 5mm 100 1000 0.01 0.1 1 10 PEAK AMPERES (A) FIGURE 4. CLAMPING VOLTAGE FOR V82ZA05 - V330ZA05 4-102 ZA Series Transient V-l Characteristics Curves (continued) s o > < uj 1000 0.0001 0.001 0.01 0.1 1 10 100 1000 PEAK AMPERES (A) FIGURE 5. CLAMPING VOLTAGE FOR V360ZA05 - V750ZA05 V68ZA2 V56ZA2 V47ZA1 V39ZA1 - V33ZA1 V27ZA1 V22ZA1 V18ZA1 ■■-!:iMi^B»:;.,ii»r:iiii":^riii':,i'^'j»iiiiii ..«■■■•::...«»; ■r*0'.*' , -irjmuum ■■■■•::::5aa*!::.„«»:;iiii'2p*iiir:.ailllliil •■::;;!n*--::iiii'«:i'!::;;i*»:iiiiii^Hiiiiii ::•:::=;<::::«»•!!: mill 10" 3 10 2 10- 1 10° 10 1 10 2 10 3 PEAK AMPERES (A) FIGURE 6. CLAMPING VOLTAGE FOR V8ZA1 - V68ZA2 10" 2 10 -1 10° 10 1 10* 10" 10' PEAK AMPERES (A) FIGURE 7. CLAMPING VOLTAGE FOR V82ZA2 - V180ZA1 10-' 10° 10 1 PEAK AMPERES (A) FIGURE 8. CLAMPING VOLTAGE FOR V8ZA2 - V68ZA3 4,000 3,000 2,000 O 1,000 > 900 X 800 < 700 UJ 600 | 500 3 400 s 5 300 2 200 100 MAXIMUM CLAMPING VOLTAGE MODEL SIZE 10mm 82 TO 180V N(DC1 RATING T» = -55°C TO +85°C 10-3 10 -2 1() .1 10 10 1 1Q 2 10 3 PEAK AMPERES (A) FIGURE 9. CLAMPING VOLTAGE FOR V82ZA4 - V180ZA5 10" 1 10° 10 1 PEAK AMPERES (A) FIGURE 10. CLAMPING VOLTAGE FOR V18ZA3 • V68ZA10 4-103 ZA Series Iff 3 10" 2 Iff 1 10° 10 1 10 2 10 3 10 4 PEAK AMPERES (A) FIGURE 13. CLAMPING VOLTAGE FOR V39ZA20 - V180ZA20 Pulse Rating Curves FIGURE 14. SURGE CURRENT RATING CURVES FOR V8ZA05 FIGURE 15. SURGE CURRENT RATING CURVES FOR V12ZA05 - V68ZA05 4-104 ZA Series Pulse Rating Curves (continued) 1 1 1 Mill MODEL SIZE 7mm V8ZA1-V12ZA1 FIGURE 16. SURGE CURRENT RATING V750ZA05 100 1,000 IMPULSE DURATION ( M s) 17. SURGE CURRENT RAT V12ZA1 "^00 MODEL SIZE 7mm V82ZA2-V180ZA1 100 1,000 IMPULSE DURATION ( M s) FIGURE 1 8. SURGE CURRENT RATING CURVES FOR V1 8ZA1 V68ZA2 100 IMPULSE DURATION^) FIGURE 1 9. SURGE CURRENT RATING CURVES FOR V82ZA2 - V180ZA1 tC « Hi > Q. 4-105 100 1,000 IMPULSE DURATION ((is) FIGURE 22. SURGE CURRENT RATING CURVES FOR V82ZA4 - 100 1,000 IMPULSE DURATION (ps) 0,000 FIGURE 23. SURGE CURRENT RATING CURVES FOR V1 8ZA3 - 5,000 1 1 — i — n - MODEL SIZE 14mm V82ZA12-V180ZA10 100 1,000 10,000 IMPULSE DURATION ( M s) FIGURE 24. SURGE CURRENT RATING CURVES FOR V82ZA12 - V180ZA10 ! 1 1 — t I I I I MODEL SIZE 20mm V18ZA40 - V68ZA20 i 100 1,000 IMPULSE DURATION ( M s) FIGURE 25. SURGE CURRENT RATING CURRENT FOR V18ZA40-V68ZA20 10,000 MODEL SIZE 20mm V120ZA20-V180ZA20 100 1,000 10,000 IMPULSE DURATION ((is) FIGURE 26. SURGE CURRENT RATING CURVES FOR V120ZA20 - V180ZA20 NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than +1 0% could result. This type of shift, which normally results in a decrease of V N(DC) , may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection. 4-106 ZA Series Tape and Reel Specifications I SEATING PLANE ' t" Ah— Ul— Ah " u " m " ns 'p,L- | J f I— ^ — Pn— i CRIMPEO LEAOS *ZT" Tape and Reel Data • Conforms to ANSI and EIA specifications • Can be supplied to IEC Publication 286-2 • Radial devices on tape are supplied with crimped leads, straight leads, or under-crimped leads STRAIGHT LEADS "ZS" UNDER-CRIMPED LEADS ■ZU" — p, 1— | —\ f L— — p„— j SYMBOL PARAMETER MODEL SIZE 5mm 7mm 10mm 14mm 20mm P Pitch of Component 12.7 ± 1.0 12.7± 1.0 25.4 ±1.0 25.4 ±1.0 25.4 ± 1.0 Po Feed Hole Pitch 12.7 + 0.2 12.7 + 0.2 12.7 ±0.2 12.7 + 0.2 12.7 ±0.2 Pi Feed Hole Center to Pitch 3.85 ± 0.7 3.85 ±0.7 2.6 ±0.7 2.6 ±0.7 2.6 ±0.7 P 2 Hole Center to Component Center 6.35 ± 1.0 6.35 ± 1.0 6.35 ± 1.0 6.35 ± 1.0 6.35 ± 1.0 F Lead to Lead Distance 5.0 ±1.0 5.0 ±1.0 7.5 ±1.0 7.5 ±1.0 7.5 ±1.0 Ah Component Alignment 2.0 Max 2.0 Max 2.0 Max 2.0 Max 2.0 Max W Tape Width 18.0 + 1.0 18.0-0.5 18.0 + 1.0 18.0-0.5 18.0 + 1.0 18.0-0.5 18.0 + 1.0 18.0 - 0.5 18.0 + 1.0 18.0-0.5 W Hold Down Tape Width 6.0 ± 0.3 6.0 ±0.3 6.0 ±0.3 6.0 ±0.3 12.0 ±0.3 W, Hole Position 9.0 + 0.75 9.0 - 0.50 9.0 + 0.75 9.0 - 0.50 9.0 + 0.75 9.0 - 0.50 9.0 + 0.75 9.0 - 0.50 9.0 + 0.75 9.0 - 0.50 w 2 Hold Down Tape Position 0.5 Max 0.5 Max 0.5 Max 0.5 Max 0.5 Max H Height from Tape Center to Component Base 18.0 + 2.0 18.0 - 0.0 18.0 + 2.0 18.0-0.0 18.0 + 2.0 18.0-0.0 18.0 + 2.0 18.0-0.0 18.0 + 2.0 18.0-0.0 Ho Seating Plane Height 16.0 ±0.5 16.0 ±0.5 16.0 + 0.5 16.010.5 16.0 ±0.5 Hi Component Height 29.0 Max 29.0 Max 29.0 Max 29.0 Max 29.0 Max Do Feed Hole Diameter 4.0 ±0.2 4.0 ±0.2 4.0 ± 0.2 4.0 ±0.2 4.0 ±0.2 t Total Tape Thickness 0.7 + 0.2 0.7 + 0.2 0.7 ± 0.2 0.7 ± 0.2 0.7 ±0.2 L Length of Clipped Lead 1 1 .0 Max 11.0 Max 11.0 Max 11.0 Max 12.0 Max Ap Component Alignment 3° Max 3° Max 3° Max 3° Max 3° Max NOTE: Dimensions are in mm. 4-107 ZA Series Tape and Reel Ordering Information Crimped leads are standard on ZA types supplied in tape and reel and are denoted by the model letter T. Model let- ter "S" denotes straight leads and letter "U" denotes special under-crimped leads. Example: SHIPPING QUANTITY STANDARD MODEL CRIMPED LEADS STRAIGHT LEADS UNDER- CRIMPED LEADS V18ZA3 V18ZT3 V182S3 V18ZU3 SIZE RMS (MAX) VOLTAGE QUANTITY PER REEL "T" REEL "S" REEL "U" REEL 5mm All 1000 1000 1000 7mm All 1000 1000 1000 10mm All 1000 1000 1000 14mm <300V 500 500 500 14mm >300V 500 500 500 20mm <300V 500 500 500 20mm >300V 500 500 500 Package Outline Dimensions 0b -J *- T 25.4 (1.00) MIN SYM- BOL VOLTAGE MODEL VARISTOR MODEL SIZE 5mm 7mm 10mm 14mm 20mm MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX A All 6 (0.236) 10 (0.394) 7.5 (0.295) 12 (0.472) 10 (0.394) 16 (0.630) 13.5 (0.531) 20 (0.787) 17.5 (0.689) 26.5 (1.043) 0D All 6 (0.236) 7 (0.276) 7.5 (0.295) 9 (0.354) 10 (0.394) 12.5 (0.492) 13.5 (0.531) 17 (0.669) 17.5 (0.689) 23 (0.906) e (Note D All 4 (0.157) 6 (0.236) 4 (0.157) 6 (0.236) 6.5 (0.256) 8.5 (0.335) 6.5 (0.256) 8.5 (0.335) 6.5 (0.256) (Notel) 8.5 (0.335) (Notel) «1 V8ZA-V56ZA 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) V68ZA- V100ZA 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) 1.5 (0.059) 3.5 (0.138) NA (NA) NA (NA) V120ZA- V180ZA 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) 1 (0.039) 3 (0.118) 1 (0.038) 1 (0.118) NA (NA) NA (NA) V220ZA- V910ZA 1.5 (0.059) 3.5 (0.138) E V8ZA-V56ZA 5 (0.197) 5 (0.197) 5 (0.197) 5 (0.197) 5 (0.197) V68ZA- V100ZA 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) V120ZA- V180ZA 5 (0.197) 5 (0.197) 5 (0.197) 5 (0.197) 5 (0.197) V220ZA- V910ZA 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 5.6 (0.220) 0b All 0.585 (0.023) 0.685 (0.027) 0.585 (0.023) 0.685 (0.027) 0.76 (0.030) 0.86 (0.034) 0.76 (0.030) 0.86 (0.034) 0.76 (0.030) 0.86 (0.034) NOTE: Dimensions in millimeters, inches in parentheses. 1. 10mm ALSO AVAILABLE; See Additional Lead Style Options. V24ZA50 only supplied with lead spacing of 6.35mm ± 0.5mm (0.25 ± 0.197) 4-108 ZA Series Additional Lead Style Options Radial lead types can be supplied with combination pre- formed crimp and trimmed leads. This option is supplied to the dimensions shown. •seating PLANE | i "Seating plane interpretation per IEC-717 CRIMPED AND TRIMMED LEAD SYMBOL VARISTOR MODEL SIZE 5mm 7mm 10mm 14mm 20mm MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX A 13.0 (0.512) 15 (0.591) 19.5 (0.768) 22.5 (0.886) 29.0 (1.142) '-TRIM 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) 2.41 (0.095) 4.69 (0.185) NOTE: Dimensions in millimeters, inches in parentheses. • To order this crimped and trimmed lead style, standard radial type model numbers are changed by replacing the model letter "ZA" with "ZC. This option is supplied in bulk only. Example: STANDARD CATALOG MODEL ORDER AS: V18ZA3 V18ZC3 • For crimped leads without trimming and any variations to the above, contact Harris Semiconductor Power Marketing. For 10/±1mm lead spacing on 20mm diameter models only; append standard model numbers by adding "X10". Example: STANDARD CATALOG MODEL ORDER AS: V18ZA40 V18ZA40X10 CO > Q. 4-109 TVS HARRIS MOV QUALITY AND RELIABILITY HARRIS MOV QUALITY AND RELIABILITY 5-3 Quality Statement 5-3 Introduction 5-3 Harris Total Quality Management Principles 5-3 ISO 9000 5-3 The Role of the Quality Organization 5-4 The Improvement Process 5-4 Harris Standard Flows 5-5 Designing for Manufacturability 5-5 Controlling and Improving the Manufacturing Process SPC/DOX 5-5 Measurement 5-6 Field Return Product Analysis System 5-6 Accrediations 5-7 Training 5-7 Reliability 5-7 Reliability Fundamentals 5-10 AC Bias Reliability 5-11 DC Bias Reliability 5-13 DC Power Tests 5-13 Pulse Energy Capability 5-14 Mechanical Reliability 5-15 Environmental and Storage Reliability 5-17 Qualification Procedures 5-17 Radiation Hardness 5-19 Safety 5-19 References 5-20 St <5 5§ < uj 5-1 "Harris is committed to being a company of the highest quality in every aspect of its business activity" John T. Hartley Chairman, Harris Corporation Introduction Success in the metal oxide varistor (MOV) industry means more than simply meeting or exceeding the demands of today's market. It also includes anticipating and accepting the challenges of the future. It results from a process of con- tinuing improvement and evolution, with perfection as the constant goal. Harris Semiconductor's commitment to supply only top value varistors has made quality improvement a mandate for every person in our work force - from designer to manufacturing operator, from hourly employee to corporate executive. Price is no longer the only determinant in marketplace competition. Quality, reliability, and performance enjoy significantly increased importance as measures of value in MOVs. Quality in varistors cannot be added on or considered after the fact. It begins with the development of capable process technology and product design. It continues in manufacturing, through effective controls at each process or step. It culminates in the delivery of products which meet or exceed the expectations of the customer. Vision Total Quality, every minute of every day, for everyone who depends on our performance. Charter To be the preferred supplier of high performance semiconductors for analog, digital signal processing and power applications. Throughout the 80's the pace of change of what has been considered 'acceptable' quality has been breathtaking. It has been a transition from percentage defective, to under 100 ppm, undertaken only by those who are still in business. The forces of change have been those of customer expectation and natural selection. Harris varistors have followed a path of strong and steady continuous improvement which today results in world-class end-product quality and reliability. The Total Quality Management principles used to create the Quality System, within which Harris varistors are made, are based on five principles. Emanating from the top of the Corporation, they are evident throughout the Semiconductor Sector, and affect the conduct of business in a profound way. Principles Customer Focus Customer satisfaction is the paramount purpose of all company activities. Meeting the requirements and value expectations of our internal and external customers is the primary task of every employee. Continuous Improvement Our planning activities will recognize continuous improvement as a primary business objective. Our products and services, together with the processes and systems which produce them, will be world class. Employee Involvement We will provide an environment and related value system in which all Harris people are personally involved, individually and as team members, in establishing and achieving quality goals. Supplier Partnerships We will develop and maintain mutually beneficial partner- ships with suppliers who share our commitment to achieving increased levels of customer satisfaction through continuing improvements in quality, service, timeliness and cost. Highest Standards of Conduct, Ethics and Integrity We will conduct our business in strict compliance with applicable laws, rules and regulations; with honesty and integrity; and with a strong commitment to the highest standards of business ethics. ISO 9000 Preparing for ISO 9000 certification means that a company as a whole looks at its total system; operational waste is eliminated and quality procedures are firmly put in place from the grass roots level all the way to the board room. This certification focuses on the concept of stating what you do, documenting what you do and then doing what you say. Simply put, this means it is necessary to document the operation from when raw material is purchased right through to the finished product. This quality management system begins with the management responsibility, including the policy statement and explanation. It also requires that the authority and responsibility be clearly defined for all functions. ISO 9000 assures a system approach to quality control. It represents a basic look at the business that is a very good way to view manufacturing and operations (Figure 1). Obtaining ISO certification really stresses the quality concepts of supplier quality, supplier partnership, and manufacturing control. The pursuit of this international certification clearly focuses on process and as a result empowers all company employees through the documentation and understanding that is necessary in becoming certified. 5-3 Harris MOV Quality and Reliability MANAGEMENT RES POLICY/AUTHORITY TRAINING/AUDITS RAW MATERIALS PURCHASING VERIFICATION TESTING STATISTICS PACKAGING STORAGE DELIVERY X PRODUCT (SERVICES) DESIGN CONTROL INPUTS/OUTPUTS VERIFICATION NONCONFORMANCE CORRECTIONS PROCESS CONTROL DOCUMENT CONTROL - SYSTEMS - PROCEDURES - RECORDS FIGURE 1. ISO 9000 LOGIC The ISO 9000 series of standards are generic in nature. The United States has adopted the ISO series word for word as the ANSI/ASQC Q90 series. ISO 9000 and ISO 9004 are basically glossary documents. A company can really only be certified to ISO 9001 , ISO 9002 and ISO 9003. The Harris MOV facility has been a registered ISO 9001 company since 1989. ISO 9001 is a model for quality assurance in the design/development, production, installation and servicing. This certification requires the demonstration of a supplier's capability to design, produce, install and service a product. ISO 9001 certification requires verification by independent auditors four times a year to ensure compliance. The Role of the Quality Organization The emphasis on building quality into the design and manu- facturing processes of a product has resulted in a significant refocus of the role of the Quality organization. In addition to facilitating the development of SPC and DOX programs and working with manufacturing to establish control charts, Qual- ity professionals are involved in the measurement of equip- ment capability, standardization of inspection equipment and processes, analysis of inspection data and feedback to the manufacturing areas, coordination of efforts for process and product improvement, optimization of raw materials quality, and the development of quality improvement programs with vendors. At critical manufacturing operations, process and product quality is analyzed through random statistical sampling and product monitors. The Quality organization's role is changing from policing quality to leadership and coordination of quality programs or procedures through auditing, sampling, consulting, and managing Quality Improvement projects. To support specific market requirements, or to ensure conformance to military or customer specifications, the Quality organization still performs many of the conventional quality functions. But, true to the philosophy that quality is everyone's job, much of the traditional on-line measurement and control of quality characteristics is where it belongs - with the people who make the product. The Quality organization is there to provide leadership and assistance in the deployment of quality techniques, and to monitor progress. The Improvement Process Harris Semiconductor's quality methodology is evolving through the stages shown in Figure 2. In 1985 we embarked on a program to move beyond Stage I, and we are currently in the transition from Stage II to Stage III, as more and more of our people become involved in quality activities. The tradi- tional "quality" tasks of screening, inspection, and testing are being replaced by more effective and efficient methods, put- ting new tools into the hands of all employees. IMPACT ON PRODUCT QUALITY PROCESS OPTIMIZATION PRODUCT SCREENING CONTROL STAGE III STAGE IV PRODUCT OPTIMIZATION SOPHISTICATION OF QUALITY TECHNOLOGY FIGURE 2. STAGES OF STATISTICAL QUALITY TECHNOLOGY 5-4 Harris MOV Quality and Reliability Harris Standard Flows Harris Semiconductor offers a variety of standard product flows which cover the myriad of application environments our customers experience. All of these grades have one thing in common. They result from meticulous attention to quality, starting with design decisions made during product development and ending with the labeling of shipping con- tainers for delivery to our customers. Wherever feasible, and in accordance with good value engi- neering practice, the MOV user should specify device grades based on the standard Harris manufacturing flow. These are more than adequate for the overwhelming majority of applica- tions and may be utilized quite effectively if the user engineer bases designs on the standard data sheet, military drawing or slash sheet (as applicable) electrical limits. Some of the more important advantages gained by using standard as opposed to custom flows are as follows: • Lower cost than the same or an equivalent flow executed on a custom basis. This results from the higher efficiency achieved with a constant product flow and the elimination of such extra cost items as special fixturing, test pro- grams, additional handling and added documentation. • Faster delivery. The manufacturer often can supply many items from inventory and, in any case, can establish and maintain a better product flow when there is no need to restructure process and/or test procedures. • Increased confidence in the devices. A continuing flow of a given product permits the manufacturer to monitor trends which may bear on end-product performance or reliability and to implement corrective action, if necessary. Reduction of risk. Since each product is processed indepen- dent of specific customer orders, the manufacturer absorbs production variability within its scheduling framework without major impact on deliveries. In a custom flow, a lot failure late in the production cycle can result in significant delays in delivery due to the required recycling time. Despite the advantages of using standard flows, there are cases where a special or custom flow is mandatory to meet design or other requirements. In such cases, the Harris Mar- keting groups stand ready to discuss individual customer needs and, where indicated, to accommodate appropriate custom flows. Designing for Manufacturability Assuring quality and reliability in MOVs begins with good product and process design. This has always been a strength in Harris Semiconductor's quality approach. We have a very long lineage of high reliability, high performance products that have resulted from our commitment to design excellence. All Harris products are designed to meet the stringent quality and reliability requirements of the most demanding end equipment applications, from military and space to industrial and automotive. The application of new tools and methods has allowed us to continuously upgrade the design process. Each new design is evaluated throughout the development cycle to validate the capability of the new product to meet the end market performance, quality, and reliability objectives. The validation process has four major components: 1 . Design simulation/optimization 2. Layout verification 3. Product demonstration 4. Reliability assessment Controlling and Improving the Manufacturing Process SPC/DOX Statistical process control (SPC) is the basis for quality control and improvement at Harris Semiconductor. Harris manufacturing people use Shewhart control charts to determine the normal variabilities in processes, materials, and products. Critical process variables are measured and control limits are plotted on the control charts. Appropriate action is taken if the charts show that an operation is outside the process control limits or indicates a trend toward the limit. These same control charts are powerful tools for use in reducing variations in processing, materials, and products. SPC is important, but still considered only part of the solution. Processes which operate in statistical control are not always capable of meeting engineering requirements. The conventional way of dealing with this in the semiconductor industry has been to implement 100% screening or inspection steps to remove defects, but these techniques are insufficient to meet today's demands for the highest reliability and perfect quality performance. Harris still uses screening and inspection to "grade" products and to satisfy specific customer requirements. However, inspection and screening are limited in their ability to reduce product defects to the levels expected by today's buyers. In addition, screening and inspection have an associated expense, which raises product cost. Harris engineers are, instead, using Design of Experiments (DOX), a scientifically disciplined mechanism for evaluating and implementing improvements in product processes, materials, equipment, and facilities. These improvements are aimed at reducing the number of defects by studying the key variables controlling the process, and optimizing the procedures or design to yield the best result. This approach is a more time-consuming method of achieving quality perfection, but a better product results from the efforts, and the basic causes of product nonconformance can be eliminated. SPC, DOX, and design for manufacturability, coupled with our 100% test flows, combine in a product assurance program that delivers the quality and reliability performance demanded for today and for the future. 5-5 Measurement Harris facilities, engineering, manufacturing, and product assurance are supported by the Analytical Services Labora- tory. Organized into chemical or microbeam analysis meth- odology, staff and instrumentation from both labs cooperate in fully integrated approaches necessary to complete analyt- ical studies. The capabilities of each area are shown below. Spectroscopic Methods: Colorimetry, Optical Emission, Ultraviolet Visible, Fourier Transform-Infrared, Flame Atomic Absorption, Furnace Organic Carbon Analyzer, Mass Spectrometer. Chromatographic Methods: Gas Chromatography, Ion Chromatography. Thermal Methods: Differential Scanning Colorimetry, Ther- mogravimetric Analysis, Thermomechanical Analysis. Physical Methods: Profilometry, Microhardness, Rheometry. Chemical Methods: Volumetric, Gravimetric, Specific Ion Electrodes. Electron Microscope: Transmission Electron Microscopy, Scanning Electron Microscope. X-Ray Methods: Energy Dispersive X-Ftay Analysis (SEM), Wavelength Dispersive X-Ray Analysis (SEM), X-Ray Fluorescence Spectrometry, X-Ray Diffraction Spectrometry. Surface Analysis Methods: Scanning Auger Microprobe, Electron Spectroscope/Chemical Analysis, Secondary Ion Mass Spectrometry, Ion Scattering Spectrometry, Ion Micro- probe. The department also maintains ongoing working arrangements with commercial, university, and equipment manufacturers' technical service laboratories, and can obtain any materials analysis in cases where instrumental capabilities are not available in our own facility. Field Return Product Analysis System The purpose of this system is to enable Harris' Field Sales and Quality operations to properly route, track and respond to our customers' needs as they relate to product analysis. The Product Failure Analysis Solution Team (PFAST) con- sists of the group of people who must act together to provide timely, accurate and meaningful results to customers on units returned for analysis. This team includes the salesman or applications engineer who gets the parts from the cus- tomer, the PFAST controller who coordinates the response, the Product or Test Engineering people who obtain charac- terization and/or test data, the analysts who failure analyze the units, and the people who provide the ultimate corrective action. It is the coordinated effort of this team, through the system described in this document that will drive the Cus- tomer responsiveness and continuous improvement that will keep Harris on the forefront of the semiconductor business. The system and procedures define the processing of prod- uct being returned by the customer for analysis performed by Product Engineering, Reliability Failure Analysis and/or Quality Engineering. This system is designed for processing "sample" returns, not entire lot returns or lot replacements. The philosophy is that each site analyzes its own product. This applies the local expertise to the solutions and helps toward the goal of quick turn time. Goals: Quick, accurate response, uniform deliverable (con- sistent quality) from each site, traceability. The PFAST system is summarized in the following steps: 1 . Customer calls the sales rep about the unit(s) to return. 2. Fill out PFAST Action Request see the PFAST form in this section. This form is all that is required to process a Field Return of samples for failure analysis. This form contains essential information necessary to perform root cause analysis. (See Figure 5). FAILURE VERIFICATION EXTERNAL INSPECTION ELECTRICAL ANALYSIS j- 1 SELECT ANALYSIS PATH SPECIAL TESTS FAILURE MODE PREDICTIONS ] FIGURE 3. NON-DESTRUCTIVE DEENCAPSULATION PROCESS DATA [research! DATA 1^ ICIRCUrr I HISTORY p [ INTERNAL VISUAL INSPECTION INTERNAL ELECTRICAL PHYSICAL TESTS ■c ANALYSIS CHEMICAL I TESTS I I CROSS | SECTION r *~ J ANALYSIS I ^ REPORT | FIGURE 4. DESTRUCTIVE 5-6 Harris MOV Quality and Reliability The units must be packaged in a manner that prevents physical damage. Send the units and PFAST form to the appropriate PFAST controller. This location can be determined at the field sales office or rep using "look-up" tables in the PFAST document. > and route them to 5. Test results will be reviewed and compared to customer complaint and a decision will be made to route the failure to the appropriate analytical group. 6. The customer will be contacted with the ATE test results and interim findings on the analysis. This may relieve a line down situation or provide a rapid disposition of material. The customer contact is valuable in analytical process to insure root cause is found. 7. A report will be written and sent directly to the customer with copies to sales, representatives, responsible individ- uals with corrective actions and to the PFAST controller so that the records will capture the closure of the cycle. 8. Each report will contain a feedback form (stamped and preaddressed) so that the PFAST team can assess their performance based on the customers assessment of quality and cycle time. 9. The PFAST team objectives are to have a report in the customers hands in 28 days, or 1 4 days based on agree- ments. Interim results are given realtime. Failure Analysis Laboratory The Failure Analysis Laboratory's capabilities encompass the isolation and identification of all failure modes/failure mechanisms, preparing comprehensive technical reports, and assigning appropriate corrective actions. Failure analysis is a method of enhancing product reliability and determining corrective action. It is the final and crucial step used to isolate potential reliability problems that may have occurred during reliability stressing. Accurate analysis results are imperative to assess effective corrective actions. To ensure the integrity of the analysis, correlation of the fail- ure mechanism to the initial electrical failure is essential. A general failure analysis procedure has been established. The analysis procedure was designed on the premise that each step should provide information on the failure without destroying information to be obtained from subsequent steps. The exact steps for an analysis are determined as the situation dictates. (See Figures 3 and 4). Records are main- tained by laboratory personnel and contain data, the failure analyst's notes, and the formal Product Analysis Report. Accrediations The Harris quality system meets or exceeds a wide range of standards, which indicates, together with the knowledge that each standard involves surveillance audits, up to four times per year, that the quality system is complete, and its integrity is being maintained. CECCOOIOOThe European Standard harmonization agency, CENELEC Electronic Component Committee, awarded Harris their "Certificate of Approval of Manufacture". Rej'n #M010, in 1986. ISO 9000 The quality system meets all of the Part 1 requirements of ISO 9000 Part 1 (ISO 9001 ). MILQ9858A, Harris is a MIL-R-83530 QPL supplier and MIL-l-45208 conforms to these standards, as well as those referenced by them. Certain product certifications with UL, CSA, VDE, IEC, JEDEC, DESC and the CECC QPL system also exist. Training The basis of a successful transition from conventional qual- ity programs to more effective, total involvement is training. Extensive training of personnel involved in product manufac- turing began in 1984 at Harris, with a comprehensive devel- opment program in statistical methods. Using the resources of the private consultants, and internally developed pro- grams, training of engineers, supervisors, and operators/ technicians has been completed. Nearly 200 operators, 10 supervisors, and more than 25 engineers have been trained in SPC methods, providing them with tools to improve the overall level of uniformity of Harris products. 25 engineers have received training in DOX methods: learning to evaluate changes in process opera- tions, set up new processes, select or accept new equip- ment, evaluate materials, select vendors, compare two or more pieces of equipment, and compare two or more pro- cess techniques. Over the past four years, Harris has also deployed a comprehensive training program for hourly operators and supervisors in job requirements and functional skills. All hourly manufacturing employees participate (see Table 1 ). Reliability The Harris Varistor is a rugged, reliable voltage transient suppressor designed to improve the reliability of electronic systems. Proper system design with this varistor, as detailed in other parts of this manual, will clamp transient voltages to a level compatible with long-life of the electronic system. To assure Harris Varistor reliability, Harris performs extensive process and quality control monitoring. This is accomplished via a combination of 100%, periodic, and lot testing. Both parametric and reliability characteristics are controlled in this manner. 5-7 Harris MOV Quality and Reliability SEMICONDUCTOR Request # Customer Analysis # PFAST ACTION REQUEST _ Date: Originator Location/Phone No. Device Type/Part No. No. Samples Returned Customer Location Purchase Order No. Quantity Received The completeness and timely response of the evaluation is directly related to the completeness of the data provided. please provide all pertinent data. attach additional sheets if necessary. TYPE OF PROBLEM DETAILS OF REJECT (Where appropriate serialize units and specify for each) □ Incoming Inspection □ 100% Screen □ Sample Inspection No. Tested No. of Rejects Are results representative of previous lots? O YES □ NO □ Brief description of evaluation and results attached 2. □ In Process/Manufacturing Failure □ Board Checkout D System Checkout □ Failed on Turn-on O Failed after hours operation Was unit retested under incoming inspection conditions? □ YES □ NO □ Brief Description of how failure was isolated to component attached Field Failure Failed after hours operation Estimated failure rate % per 1000 hours End User Location Ambient Temperature C Min. C Max. C Test Conditions Relating to Failure D Tester Used (MFGR/MODEL) □ Test Temperature □ Test Time: □ Continuous Test □ One Shot (T = _sec) Description of any observed condition to which failure appears sensitive: 3. O 1. O 2. n DC Failures □ Opens O Shorts □ Leakage □ Stress D Power Drain D Input Level □ Output Level □ List of forcing conditions and measured results for each pin is attached □ power supply sequencing attached AC Failures List Failing Characteristics Rel. Humidity % □ End User failure correspondence attached ACTION REQUESTED BY CUSTOMER Specific Action Requested . Impact of Failed Units on Customer's Situation: 3. □ of Failing Location (if applicable) Attached: □ List of Power Supply and Driver Levels (Include pictures of waveforms). □ List of output levels and loading conditions □ Input and Output Timing Diagrams □ Description of Patterns Used (If not standard patterns, give very complete description including address sequence). PROM Programming Failures Address of Failures Customer Contacts with Specific Knowledge of Rejects Name Position Phone Programmer Used (MFG/Model/Rev. No.) □ Physical/Assembly Related Failures □ See Comments Below □ See Attached Additional Comments: FIGURE 5. PFAST ACTION REQUEST 5-8 Harris MOV Quality and Reliability TABLE 1. SUMMARY OF TRAINING PROGRAMS COURSE AUDIENCE LENGTH TOPICS COVERED SPC Manufacturing Operators 8 Hours Basic Philosophy, Statistical Calculations Graphing Techniques, Pareto Charts, Control Charts SPC Manufacturing Supervisors 21 Hours Basic Philosophy, Statistical Calculations Graphing Techniques, Pareto Charts, Control Charts, Testing for Inspector Agreement, Cause & Effect Diagrams, 1 & 2 Sample Methods SPC Engineers and Managers 48 Hours Basic Philosophy, Graphical Methods, Control Charts, Rational Subgrouping, Variance Components, 1 & 2 Sample Methods, Pareto Charts, Cause & Effect Diagrams DOX (Design of Experiments) Engineers and Managers 88 Hours Factorial Designs, Fractional Factorial Designs, Blocking Designs, Variance Components, Computer Usage, Normal Probability Plotting Continuous Improve- ment Methods Manufacturing Supervisors 12 Hours Basic Philosophy, Pareto Analysis, Imagineering, Run Charts, Cause & Effect Diagrams, Histograms, Ideas of Control Charts SPC-The Essentials Department- Level Work Groups 20 Hours Basic Philosophy, of Continuous Improvement, Imagineering Pareto Charts, Cause & Effect Diagrams, Flow Charts, Graphical Display, Control Charts, Ideas of Experiment In addition to the already widespread use of statistics, SPC and DOX the following tools are now being widely distributed throughout the whole workforce. • P.M. Preventative Maintenance • T.P.M. Total Productive Maintenance • F.M.E.A. Failure Mode Effect Analysis • A.C.T. P.T.M Applying Concurrent Teams to Product to Ma • A.F.E. Agreement for Excellence rk at • Process Characterization Skills • Project Management • Concurrent Engineering For example, Harris Varistors are classified into two catego- ries; a "line voltage" type (above 1 1 5V RMS ) and a "low volt- age" type (below 115V RMS ). Reliability evaluation has been conducted on both types under the conditions summarized in Table 2 TABLE 2. RELIABILITY EVALUATION TEST CONDITION STRESS Voltage AC Bias, DC Power Temperature 85°C, 125°C Energy Pulse Storage 125°C, 150°C Humidity 85°C, 85% RH Mechanical Solderability, Terminal Strength, Drop Shock, Vibration As improved products, processes, and test procedures evolve, the applicability of past data to reliability assessment changes. Thus, the data presented in this chapter represents a "snapshot in time" of data applicable to the Harris Varistors being manufactured now and for the anticipated future. The test data has been generated at very high stress levels, at or beyond maximum ratings, to confirm the product's ability to meet these ratings and to obtain the most information in the shortest time period. Results of AC voltage and DC power bias tests are used in the generation of models from which the expected life as a function of A general "High Reliability" series of Harris Varistors is also available. These are specially stress-screened devices for high reliability applications. 5-9 Harris MOV Quality and Reliability High Reliability Harris Varistors are the latest step in increased product performance, and are available for appli- cations requiring quality and reliability levels consistent with military test methods. Reliability Assessment and Enhancement At Harris Semiconductor, reliability is built into every product by emphasizing quality throughout manufacturing. This starts by ensuring the excellence of the design, layout, and manu- facturing process. The quality of the raw materials and work- manship is monitored using statistical process control (SPC) to preserve the reliability of the product. The primary and ulti- mate goal of these efforts is to provide full performance to the product specification throughout its useful life. Product reliabil- ity is maintained through the following sources: Qualifications, In-Line Reliability Monitors, Failure Analysis. Reliability Fundamentals Reliability, by its nature, is a mixture of engineering and probability statistics. This combination has derived a vocabulary of terms essential for describing the reliability of a device or system. Since reliability involves a measurement of time, it is necessary to accelerate the failures which may occur. This, then, introduces terms like "activation energy" and "acceleration factor," which are needed to relate results of stressing to normal operating conditions (see Table 3). Also, to assess product reliability requires failures. Therefore, only a statistical sample can be used to determine the model of the failure distribution for the entire population of product. TABLE 3. GLOSSARY OF TERMS TERMS/DEFINITIONS UNITS/DESCRIPTION FAILURE RATE (X) For Semiconductors, usually expressed in FITs. Represents useful life failure rate (which implies a constant failure rate). FITs are not applicable for infant mortality or wearout failure rate expressions. FIT (Failure In Time) 1 FIT - 1 failure in 10 9 device hours. Equivalent to 0.0001%/1000 hours FITs = . x m hours stress x AF m - Factor to establish Confidence Interval 10 9 - Establishes in terms of FITs AF - Acceleration Factor at temperature for a given failure mechanism MTTF (Mean Time To Failure) For semiconductors, MTTF is the average or mean life expectancy of a device. If an exponential distribution is assumed then the mean time to fail of the population will be when 63% of the parts have failed. Mean Time is measured usually in hours or years. 1 Year = 8760 hours When working with a constant failure rate the MTTF can be calcu- lated by taking the reciprocal of the failure rate. MTTF = IA (exponential model) Example: =10 FITs at +55°C The MTTF is: MTTF= l/X = 0.1 x 10 9 hours = 1 00M hours CONFIDENCE INTERVAL (CI) Establishes a Confidence Interval for failure rate predictions. Usu- ally the upper limit is most significant in expressing failure rates. Example: "10 FITs at a 95% C. L at 55°C" means only that you are 95% cer- tain the FITs <10 at +55°C use conditions. 5-10 Harris MOV Quality and Reliability Failure Rate Calculations Reliability data for products may be composed of several different failure mechanisms and requires careful combining of diverse failure rates into one comprehensive failure rate. Calculating the failure rate is further complicated because failure mechanisms are thermally accelerated at varying rates and thereby have differing accelerating factors. Additionally, this data is usually obtained on a variety of life tests at unique stress temperatures. The equation below accounts for these considerations and then inserts a statistical factor to obtain the confidence interval for the failure rate. X= It — ! i = 1 Mx10 i = 1 where k = Failure rate in FITs P = Number of distinct possible failure mechanisms k = Number of life tests being combined Xj = Number of failures for a given failure mechanism 1 = 1,2, p TDHj = Total device hours of test time for life test J, J = 1 , 2, . . . k AF,| = Acceleration factor for appropriate failure mechanism 1 = 1. 2. ...k where X 2 = Chi-square factor for 2r + 2 degrees of freedom r = Total number of failures (Sxi) a = Risk associated with the confidence limit In the failure rate calculation, Acceleration Factors (AFjj) are used to derate the failure rate from thermally accelerated Life Test conditions to a failure rate indicative of use temper- atures. Though no standards exist, a temperature of +55°C has been popular and allows some comparison of product failure rates. Acceleration Factors The Acceleration Factors (AF) are determined from the Arrhenius Equation. This equation is used to describe phys- iochemical reaction rates and is an appropriate model for expressing the thermal acceleration of semiconductor failure mechanisms. AF = EXP K U, 1 USE STRESS AF = Acceleration Factor E A = Thermal Activation Energy in eV K = Boltzmann's Constant (8.62x 10~ 5 eW°l<) Both T USE and T STRES s (in degrees Kelvin) include the inter- nal temperature rise of the device and therefore represent the junction temperature. With the use of the Arrhenius Equation, the thermal Activation Energy (E A ) term is a major influence on the result. This term is usually empirically derived and can vary widely. Activation Energy To determine the Activation Energy (E A ) of a mechanism you must run at least two (preferably more) tests at different stresses (temperature and/or voltage). The stresses will pro- vide the time to failure (T f ) for the populations which will allow the simultaneous solution for the Activation Energy by putting the experimental results into the following equations. ln(. (1 ,= C + R A ln(t f2 )= C + KT„ Then, by subtracting the two equations, the Activation Energy becomes the only variable, as shown. 1n(t M ) -1n(t |2 ) = E A /k(1/T1-1/T2) E A = K-((1n(t (1 )-1n(t |2 ))/(1/T1-1/T2)) The Activation Energy may be estimated by graphical analy- sis plots. Plotting In time and In temperature then provides a convenient nomogram that solves (estimates) the Activation Energy. All Harris Reliability Reports from qualifications and Group C1 (all high temperature operating life tests) will provide the data on all factors necessary to calculate and verify the reported failure rate (in FITs) using the methods outlined in this primer. AC Bias Reliability Many applications of Harris Varistors are as transient sup- pressors on an AC line. The varistor is connected across the AC line voltage and is biased with a constant amplitude sinu- soidal voltage. If the varistor current increases with time, the power dissipation will also increase, with the ultimate possi- bility of thermal runaway and varistor failure. Because of this possibility, an extensive series of statistically designed tests were performed to determine the reliability of this type of varistor under AC bias combined with high levels of temper- ature stress. This test series contained over one million device hours of operation at temperatures up to 1 50°C. The average duration of testing ranged from 7000 hours at low stress to 495 hours at high stress. The definition of failure is a shift in V N exceeding ±10%. Although this type of varistor is still functioning normally after this magnitude of shift, devices at the lower extreme of V N tolerance will begin to dissipate more power. As previously explained, this could ultimately lead to failure. This choice of failure definition, in 5-11 Harris MOV Quality and Reliability combination with the lower stresses found in applications, will provide life estimates adequate for most design require- ments. The results of these accelerated high level tests showed that the response of the Harris Varistor is an excellent fit to the Arrhenius model, i.e., the expected mean life is logarithmi- cally related to the inverse of the absolute temperature. This type of Arrhenius model response is shown in Figure 6 for the line voltage and the low voltage types of varistors. As shown in the illustrations this response can be described in the following general equation. A b = A.exp Where: A b = Mean Time to Failure Ea = Activation Energy (eV) K = Boltzmann's Constant (8.63 x 10-5 eV/K) T = Absolute Temperature (K) A = Constant This type of statistical model also allows a prediction of the mean life that can be expected at normal operating tempera- tures. The usual ambients are well below the temperature levels chosen for accelerated testing. For example, a V130LA10A operating at 130V AC in a 55°C environment has a mean life, from Figure 6A, of about 9,152,824 hours (1045 years). Note at the lower bias voltage an even longer mean life is expected. Although the V130LA and V68ZA type devices are specifically described, the results are represen- tative of other types of Harris Varistors. Additional evidence of the conservative ratings of the Harris Varistor is the absence of systematic or repeated field failures during over fifteen years of product use. 10 s _ 10 ; B E l 10< UJ £ 3 10 ! z | 10* 10= o— MAX VOLTAGE STRESS - — - vo o M LT/ E S' "RE ss • , - * * > DEVICE TYPE: V68ZA FAILURE CRITERIA: AV N > ±10% i i l l l l i i J i. . 100 50 180 160 140 120 100 90 80 70 60 50 40 30 25 AMBIENT TEMPERATURE (°C) FIGURE 6B. LOW VOLTAGE HARRIS VARISTOR FIGURE 6. ARRHENIUS MODELS OF VARISTOR MEAN LIFE VS TEMPERATURE It is noted that the mean life curves have a steep slope. This indicates a high activation energy. As operating temperature is decreased, the mean life increases rapidly. Also, as the voltage stress is lowered, life expectancy will also increase. The maximum stress curve represents the worst-case condi- tion of a device at its lowest voltage limit operated at the maximum allowable rating. In usual practice, the median of a population of devices will operate close to the 80% voltage stress curve. For some applications the circuit designer requires other sta- bility information to assess the effects of time on circuit performance. Figures 7, 8, and 9 illustrate the stability of additional Harris Varistor parameters when operated at max- imum rated voltage and 100°C for 10,000 hours (-1.15 years). The graphs indicate upper decile, median and lower decile response, furnishing useful design information on the stability of V N , standby power drain, and the nonlinear expo- nent (a). 10" .10' | 10 6 ■ !i V MAX VOLTAGE STRESS . - • 80% MAX VOLTAGE 51 R ESS ES TIM AT ✓ • s / ✓ •v - DEVICE TYPE: V130LA FAILURE CRITERIA: AV N > ±10% 1 ,0 40 1 20 100 90 80 70 60 50 40 3 02 5 100 > 50 ~ J AMBIENT TEMPERATURE (°C) SAM DEVI OPE ?LE S CETY 1ATIN ZE n = 43 PE: V130LA 3 LIFE: V = 1 ' 30V HMS ATT A = 100°C PERCENTILES 90TH 1 50TH X 10TH 4000 HOURS UNDER STRESS 10,000 FIGURE 6A. LINE VOLTAGE HARRIS VARISTOR FIGURE 7. VOLTAGE STABILITY 5-12 Harris MOV Quality and Reliability O 35 SAM DEV OPE cc ME PLE S CETY WIN ASUF ZE n = 43 PE: V130LA G LIFE: V = Fn at- mi 30V RHS ATT A = 100°C 1 .OmA PERCENTILES < 90TH 50TH 10TH 1000 2000 8000 10,000 HOURS UNDER STRESS FIGURE 8. NONLINEAR EXPONENT STABILITY SAMPLE SIZE n = 43 DEVICE TYPE: V130LA - OPERATING LIFE: V * 130V RMS ATT 4 = 100°C 4000 8000 10,000 HOURS UNDER STRESS FIGURE 9. LEAKAGE STABILITY DC Bias Reliability Harris Varistors are also applied across DC power lines where transient impulses may occur. This application more frequently uses the low voltage type of device. The varistor is designed to have high reliability when the DC bias voltage is below V N , where the current is of the order of microam- peres and little average power is dissipated. This operation is analogous to the AC bias condition. Varistors can operate reliably under power dissipation from intermittent transient pulses. Ratings are provided in the specifications for this type of service. Operation is not char- acterized for continuous power dissipation since transient applications generally do not require this capability. The stress under continuous power dissipation can be severe and its effects are shown below for design guidance. DC Bias Voltage Tests The application of a constant DC voltage within device rat- ings to the Harris Varistor results in a low stress. A high degree of stability is desired, as in the AC voltage case, as the danger of increasing power dissipation with time exists. Life tests of Harris Varistors on constant DC voltage bias at accelerated test conditions were conducted. Measurements indicate stability is at least comparable to the results of AC voltage tests. The data is illustrated in Figure 10. Failure criteria on this test is defined as a ±10% shift in V N . No units exceeded this failure limit during the 3000-hour accelerated test. It should be noted that the polarity of parameter readout is the same as the polarity of the stress. 75 > z > St Oi DC MPLE VICE1 :volt SIZE n = 3 "YPE: V68 AGE LIFE: IA V = 5SV DC ,T A = 125< C PERCENTILES 90TH ' 50TH 168 500 1000 2000 3000 HOURS UNDER STRESS FIGURE 10. ACCELERATED DC VOLTAGE LIFE DC Power Tests Application of a constant current to the varistor results in nearly a constant power condition. In practice, a constant power life test can be implemented easily, using a current limiting resistor and a voltage source about twice V N for sig- nificant power levels that are above the rating. The long-term response is characterized by a continuing increase in leak- age current, especially noticeable at low voltages. This is illustrated in Figure 11 . This test is at a high stress compared to the normal application levels. The change in leakage causes V N to fall gradually with time. This is illustrated by Figures 12 and 14 showing V N vs time. SAMPLE SIZE n = 20 DEVICE TYPE: V24ZA4 (SIMILAR TO V22ZA3) DC POWER LIFE: P„ = 0.6W AT T A = 55°C 150 500 1000 1500 HOURS UNDER STRESS FIGURE 11. ACCELERATED DC POWER LIFE, LEAKAGE CUR- RENT VARIATION FOR LOW VOLTAGE VARISTOR 5-13 Harris MOV Quality and Reliability The response to DC power life may be put into further per- spective with an analysis of a series of accelerated tempera- ture tests. These tests were run on low voltage products at stress temperatures of 55°C, 100°C, 125°C, and 145°C. The change in low voltage leakage current was selected as the most sensitive indicator of degradation and was plotted against time. The device end-of-life was defined at a leakage current limit of 100nA. The mean life results were found to be a good fit to the Arrhenius model as shown in Figure 13. The self-heating caused by device power dissipation was added to the ambient temperature of the test. This Arrhenius model can be used to predict mean life at normal operating temperatures by extrapolation. For example, at 55°C operat- ing ambient, a mean life of 2,400,000 hours (271 years) con- tinuous operation is projected. This is equivalent to a constant average failure rate of 0.42 Parts Per Million or 0.042% per 1,000 hours. With judicious derating to a modest power level, the varistor may be used at continuous power dissipation on a DC line. These applications are limited and highly specialized as the device is intended primarily for intermittent, transient service. I 24 PERCENTILES 1 — — 90TH 50TH 10TH SAMPLE DEVICE DCPOV\ SIZE n = 20 TYPE: V24ZA4 ER LIFE: P D = >.6WATT A = 55 °C 150 500 1000 1500 HOURS UNDER STRESS FIGURE 12A. LOW VOLTAGE VARISTOR SAMPLE SIZE n = 60 "DEVICE TYPE: V130LA DC POWER LIFE: P D = 0.5W AT T A = 100°C 500 1000 1500 HOURS UNDER STRESS FIGURE 12B. LINE VOLTAGE VARISTOR FIGURE 12. ACCELERATED DC POWER LIFE, V N ( DC ) VARIA- TION 180 160 140 120 100 90 80 70 60 50 40 30 25 AMBIENT TEMPERATURE (°C) FIGURE 13. RELIABILITY MODEL DC POWER LIFE Pulse Energy Capability The ability of the Harris Varistor to absorb large amounts of transient energy is the key to its utility. No other suppressor device combines equal performance with the same economic advantage. Pulse energy is absorbed throughout the bulk of the device. The effect of pulse stress is to shift the low current end of the V-l characteristic as illustrated in Figure 14. With sufficient stress (unipolar) the curve will become asymmetrical as shown in Figure 14A. Other forms of electrical or temperature stress affect the low current region as well. The general response to most stress is a shift of the low current V-l segment to the right. That is the main reason for the consistent use of the failure definition as a change in V N 190 180 (NOTE) J 1 I 1 1 1 No. of Alternating Pulses 2 + 24 2 + 24 50 1 Peak Current (A) 500 125 500 125 5 1200 Pulse Duration (us) 8x20 8 x 20 8x20 8x20 10x1000 8x20 Test Temperature (°C) 25 85 25 85 With 130V RMS Applied Yes Yes No Yes Catastrophic Failures vs Sample Size 0/3 0/3 0/10 0/10 FIGURE 15. VOLTAGE TYPE: V130LA2 (7mm) — 240 ~ 230 o 220 > 210 200 (NOTE) : 1 : 1 I ; I No. of Alternating Pulses 2 + 24 2 + 24 50 1 Peak Current (A) 3000 750 3000 750 25 4500 Pulse Duration ((is) 8x20 8x20 8x20 8x20 10 x 1000 8x20 Test Temperature (°C) 25 85 25 85 With 130V RMS Applied Yes Yes No No Catastrophic Failures vs Sample Size 0/3 0/3 0/10 0/10 FIGURE 16A. VOLTAGE TYPE: V130LA10A (14mm) — 225 215 O 205 > 195 185 (NOTE) I 1 1 1 I I I I No. of Alternating Pulses 2 + 24 2 + 24 50 1 Peak Current (A) 3000 750 3000 750 50 6500 Pulse Duration (us) 8x20 8x20 8x20 8x20 10 x 1000 8x20 Test Temperature (°C) 25 85 25 85 With 130V RMS Applied Yes Yes No No Catastrophic Failures vs Sample Size 0/3 0/3 0/10 0/10 FIGURE 16B. VOLTAGE TYPE: V130LA20A (20mm) NOTE: These test conditions simulate very closely those called for in the transient voltage suppression test and the duty cycle test of UL1449. 5-16 Harris MOV Quality and Reliability types. Also note that the plastic encapsulate complies with the flammability requirement of Underwriters Laboratories Standards UL492 and UL1410, superseded by UL1414. 0.01 0.1 1 10 20 3040 60 60 90 99 99.9 99.99 CUMULATIVE PERCENT FAILURE FIGURE 18A. LOW VOLTAGE VARISTOR (TYPE V68ZA) O 150 -20 _l_ -1o _1_ 2 z > 190 180 PERCENTILES 90TH 50TH 10TH SAMPL _ DEVICE E SIZE n = 45 TYPE: V130LA STORAGE LIFE: T A = 125°C I 168 500 1000 HOURS UNDER STRESS FIGURE 19B. LINE VOLTAGE VARISTORS FIGURE 19. ACCELERATED STORAGE LIFE The 1000-hour stability life during accelerated humidity testing is shown in Figure 20. Note that the low voltage varistor type has been subjected to two tests sequentially. The normal 40°C, 95% R.H., 1000-hour test was followed by the very severe 85°C, 95% R.H. test. Excellent stability is observed through this combined testing sequence. Qualification Procedures New products are reliably introduced to market by the proper use of design techniques and strict adherence to process layout ground rules. Each design is reviewed from its con- ception through early production to ensure compliance to minimum failure rate standards. New process/product qualifications have two major require- ments imposed. First is a check to verify the proper use of process methodology, design techniques, and ground rules. Second is a series of stress tests designed to accelerate fail- ure mechanisms and demonstrate its reliability. From the earliest stages of a new product's life, the design phase, through layout, and in every step of the manufactur- ing process, reliability is an integral part of every Harris Semiconductor product. This kind of attention to detail "from the ground up" is the reason why our customers can expect the highest quality for any application. 5-17 Harris MOV Quality and Reliability TABLE 4. MECHANICAL TEST RESULTS ON VARISTOR PACKAGES MILITARY TEST METHOD CONDITION TEST (FAILURES/SAMPLE) PACKAGE TYPE RADIAL LA/ZA INDUSTRIAL DA/DB LOW-PROFILE RADIAL RA CONNECTOR PIN CP Severability MIL-STD-750 Method 2026.2 230°C, 5s dip 95% wetting 0/60 0/20 0/60 0/20 Terminal Strength MIL-STD-750 Method 2036.3 3 bends, 90 deg. Arc 8oz. Weight 0/30 N/A 0/20 N/A Mechanical Shock MIL-STD-750 Method 2016.2 1500g's, 0.5ms 5 Pulses, XI, Yl, Z1 0/60 0/10 0/40 0/42 Vibration MIL-STD-750 Method 2056 20g's, 100Hz- 2000Hz X1, YI.ZI 0/50 0/10 0/50 0/40 Flammability MIL-STD-202 Method 111 A 15s Torching 10s to Flameout 0/80 0/50 0/60 N/A Constant Acceleration MIL-STD-750 Method 2006 Y2, 20,000g's Min. 0/60 N/A 0/60 0/40 TABLE 5. ELECTRICAL AND ENVIRONMENTAL TEST RESULTS ON VARISTOR PACKAGES MILITARY TEST METHOD CONDITION TEST (FAILURES/SAMPLE) PACKAGE TYPE RADIAL LA/ZA INDUSTRIAL DA/DB LOW-PROFILE RADIAL RA CONNECTOR PIN CP Operating Life N/A 125°C, 1000 hrs. Bias Voltage 0/200 0/50 0/150 0/100 High-Temperature Storage MIL-STD-750 Method 1032 150°C, 1000 hrs. 0/300 0/50 0/120 0/100 Thermal Shock MIL-STD-750 Method 1051 -55°Cto+125°C 5 Cycles 0/200 0/40 0/140 0/42 Humidity N/A 85°C; 85% R.H. 0/150 0/50 0/100 0/80 SAMPLE SIZE n = 30 DEVICE TYPE: V68ZA HUMIDITY LIFE: ' 40°C, 95% RH FOR 1000HRS. 90TH PERCENTILES HUMIDITY LIFE: 85°C, 95% RH FOR 168 500 1000" HOURS UNDER STRESS 220 210 _ 200 > z * 190 180 170 PERCENTILES 10TH SAMPLE SIZE n = 55 DEVICE TYPE: V130LA HUMIDITY LIFE: 40°C, 95% R.H. i 4- 1000 HOURS UNDER STRESS FIGURE 20A. LOW VOLTAGE VARISTORS FIGURE 20B. LINE VOLTAGE VARISTORS FIGURE 20. ACCELERATED HUMIDITY LIFE 5-18 Harris MOV Quality and Reliability Radiation Hardness For space applications, an extremely important property of a protection device is its response to imposed radiation effects. Electron Irradiation A Harris MOV and a silicon transient suppression diode were exposed to electron irradiation. The V-l Curves, before and after test, are shown in Figure 21. HARRIS MOV * * * rSILICON TRANSIE SUPPRE DIODE NT SSION t 1 1 PR 10 ! 1M I TEST RADS, /lev ELEC TRONS 10T 8 10T* 10T 4 CURRENT (A) 10T 2 FIGURE 21. RADIATION SENSITIVITY OF HARRIS V130LA1 AND SILICON TRANSIENT SUPPRESSION DIODE It is apparent that the Harris MOV was virtually unaffected, even at the extremely high dose of 10 8 rads, while the silicon transient suppression diode showed a dramatic increase in leakage current. Neutron Effects A second MOV-Zener comparison was made in response to neutron fluence. The selected devices were equal in area. Figure 22 shows the clamping voltage response of the MOV and the zenerto neutron irradiation to as high as 10 15 N/cm 2 . It is apparent that in contrast to the large change in the zener, the MOV is unaltered. At higher currents where the MOV's clamping voltage is again unchanged, the zener device clamping voltage increases by as much as 36%. 100 80 60 > 50 " 40 1.5K200 AT10 13 1.5K200 1.5K200 AT 10" AT10 15 mm i nun 1 1 nni 10» 10 r 10 6 10 s 10 4 10 3 (A) FIGURE 22. V-l CHARACTERISTIC RESPONSE TO NEUTRON IR- RADIATION FOR MOV AND ZENER DIODE DEVICES Counterclockwise rotation of the V-l characteristics is observed in silicon devices at high neutron irradiation levels; in other words, increasing leakage at low current levels and increasing clamping voltage at higher current levels. The solid and open circles for a given fluence represent the high and low breakdown currents for the sample of devices tested. Note that there is a marked decrease in current (or energy) handling capability with increased neutron fluence. Failure threshold of silicon semiconductor junctions is further reduced when high or rapidly increasing currents are applied. Junctions develop hot spots, which enlarge until a short occurs if current is not limited or quickly removed. The characteristic voltage current relationship of a PN-Junc- tion is shown in Figure 23. SATURATION CURRENT I FORWARD BREAKDOWN I BIAS VOLTAGE" l / REDUCTION IN T f FAILURE STRESSHOLD MM^. BY RADIAL T _ ^^^k SECONDARY ^ BREAKDOWN \ REVERSE FIGURE 23. V-l CHARACTERISTIC OF PN-JUNCTION At low reverse voltage, the device will conduct very little cur- rent (the saturation current). At higher reverse voltage V B0 (breakdown voltage), the current increases rapidly as the electrons are either pulled by the electric field (Zener effect) or knocked out by other electrons (avalanching). A further increase in voltage causes the device to exhibit a negative resistance characteristic leading to secondary breakdown. This manifests itself through the formation of hotspots, and irreversible damage occurs. This failure threshold decreases under neutron irradiation for zeners, but not for Zinc Oxide Varistors. Gamma Radiation Radiation damage studies were performed on type V130LA2 varistors. Emission spectra and V-l characteristics were col- lected before and after irradiation with 10 6 rads Co 60 gamma radiation. Both show no change, within experimental error, after irradiation. Safety The Harris Varistor may be used in systems where person- nel safety or equipment hazard is involved. All components, including this semiconductor device, have the potential of failing or degrading in ways which could impair the proper operation of such systems. Well-known circuit techniques 5-19 self-checking. Fault analysis of any systems where safety is in question is recommended. Potential device reaction to various environmental factors has been discussed through- out this section. These and any other environmental factors should be analyzed in all circuit designs. Should the varistor be subjected to surge currents and energy levels substantially above its maximum ratings, it may physically fail by package rupture or expulsion of mate- rial. It is recommended that protective fusing be used as described in Section 6. If not fused, the varistor should be located away from other components or be physically shielded from them. Harris Varistors have received listing under applicable Underwriters Laboratories standards UL-1449 (file E75961), UL-497B (file E135010), and UL-1414 (file E56529). tacted for a customized reliability program. It is stressed that most Harris Varistor parameter and reliabil- ity testing requires the use of voltages of a magnitude that is hazardous. When Harris Varistor testing is contemplated, provisions must be made to insure personnel safety. References [1] Erwin A. Herr, Alfred Poe and Albert Fox, "Reliability Evaluation and Prediction for Discrete Semiconduc- tors," EEE Transactions on Reliability, Volume R-29 No. 3, August, 1980, GE Pub. No. 300.1. [2] A.V. Fiegenbaum, Total Quality Control, New York; McGraw Hill, Third Edition, 1983. TVS DESIGNING WITH VARISTORS PAGE DESIGNING WITH VARISTORS 6-3 Selecting the Varistor 6-3 Failure Modes and Varistor Protection 6-6 Series and Parallel Operation of Varistors 6-10 Applications 6-11 Reference 6-21 X P w > 6-1 Designing With Varistors Selecting the Varistor The varistor must operate under steady-state and transient conditions. Device ratings allow a selection of the proper size device to insure reliable operation. The selection pro- cess requires a knowledge of the electrical environment. When the environment is not fully defined, some approxima- tions can be made. For most applications, selection is a five-step process: 1 . Determine the necessary steady-state voltage rating (working voltage) 2. Establish the transient energy absorbed by the varistor 3. Calculate the peak transient current through the varistor 4. Determine power dissipation requirements 5. Select a model to provide the required voltage-clamping characteristic Refer also to Section 4 "How to Select a Harris Varistor," and "How to Connect a Harris Varistor." Steady-State Voltage Rating Consider the maximum steady-state voltage applied to the varistor including any high line conditions (i.e., 110% or more of nominal voltage). Ratings are given for sinusoidal AC and constant DC. If a nonsinusoidal waveform is applied, the recurrent peak voltage should be limited to ^x V M(AC) . Specifications for the LA Series varistor are shown in Table 1 for 1 30V AC rated devices to illustrate the use of the ratings and characteristics table. Model Number - Indicates an AC voltage rating of 130V RMS for LA Series Vm(ac) " These models can be operated continuously with up to 130V RMS at 50Hz - 60Hz applied. They would be suit- able for 117V AC nominal line operation and would allow for a 110% high line condition. V M(DC) ■ Operation is allowable with up to 175V DC constant voltage applied continuously. V N(DC) ■ Min - Indicates the minimum varistor terminal volt- age that will be measured with 1mA D c applied. This is a characteristic of the device and is a useful parameter for design or for incoming inspection. V N(DC) " Max - Indicates the maximum limit of varistor termi- nal voltage measured at 1mA D c- The format for the model number designation is shown below. Note, the model series are grouped in two forms. One group is based on the AC voltage rating for applications pri- marily across the power line. The second group is based on the Vn(qq characteristic voltage. BA/BB, C-HI, CA, CP, CS, DA, DB, HA, LA, NA, PA SERIES Selection - Clamping Voltage (A or B) Relative Energy Indicator V 130 LA 20 A Product Series Max RMS Applied Voltage (Working Voltage) MOV Varistor FIGURE 1 A. TABLE 1. RATINGS AND SPECIFICATIONS EXAMPLE MODEL NUMBER MODEL SIZE DISC DIA. (mm) DEVICE MARK- ING MAXIMUM RATINGS (85°C) SPECIFICATIONS (25°C) CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1m A DC TEST CURRENT MAX CLAMP- ING VOLTAGE V c AT TEST CURRENT (8/20us) TYPICAL CAPACI- TANCE Vrms Vdc ENERGY (10/1000MS) PEAK CURRENT (8/20 M s) V M(AC) V M(DC) w TM h-H MIN V N(DC) MAX V C 'p f = 0.1-1 MHz (V) (V) (J) (A) (V) (V) (V) (V) (A) (pF) V130LA1 7 1301 130 175 11 1200 184 200 255 390 10 180 V130LA2 7 1302 130 175 11 1200 184 200 228 340 10 180 V130LA5 10 1305 130 175 20 2500 184 200 228 340 25 450 V130LA10A 14 130L10 130 175 38 4500 184 200 228 340 50 1000 V130LA20A 20 130L20 130 175 70 6500 184 200 228 340 100 1900 V130LA20B 20 130L20B 130 175 70 6500 184 200 220 325 100 1900 6-3 Designing With Varistors AUML, CH, MA, ML, RA, ZA SERIES V 220 MA 4 A Selection - Clamping Voltage (A or B) Relative Energy Indicator Product Series — V N (DC) Nominal Varistor Voltage MOV Varistor FIGURE 1B. FIGURE 1. MODEL NUMBER NOMENCLATURE Energy Transient energy ratings are given in the W TM column of the specifications in joules (watt-second). The rating is the maximum allowable energy for a single impulse of 10/1 000ns current waveform with continuous voltage applied. Energy ratings are based on a shift of V N of less than ±10% of initial value. When the transient is generated from the discharge of an inductance (i.e., motor, transformer) or a capacitor, the source energy can be calculated readily but, in most cases the transient is from a source external to the equipment and is of unknown magnitude. For this situation an approxima- tion technique can be used to estimate the energy of the transient absorbed by the varistor. The method requires find- ing the transient current and voltage applied to the varistor. To determine the energy absorbed the following equation applies: E = J T V c (t)l(t)At = KV c k where I is the peak current applied, Vq is the clamp voltage which results, t is the impulse duration and K is a constant. K values are given in Figure 2 for a variety of waveshapes frequently encountered. The K value and pulse width corre- spond to the current waveform only, assuming the varistor voltage waveform is almost constant during the current impulse. For complex waveforms, this approach also can be used by dividing the shape into segments that can be treated separately. WAVESHAPE EQUATION Kt I A" ., 'PK 0.637 — w 'pk (I) ■ ft K ► t W rVS. 0.5 i PK l pK sin (itt) e 0.86 - IPK S — 0.5 l PK , -t/1.44t 'PK 8 1.4 * T W lPK 1.0 ► t t Based upon alpha of 25 to 40 FIGURE 2. ENERGY FORM FACTOR CONSTANTS Consider the condition where the exponential waveform shown below is applied to a V130LA1 Harris Varistor. 50A 6-4 Designing With Varistors The waveform is divided into two parts that are treated sepa- rately using the factors of Figure 2: current waveform Sec- tion (1) to 5ns and (2) 5us to 50us. The maximum voltage across the V130LA1 at 100A is found to be 500V from the V-l characteristics of the specification sheet. Section(1)E = KV k = (0.5) (500) (100) (5) (10 -6 ) =0.13J Section (2) E = KV c lt = (1.4) (500) (100) (50-5) 10' 6 )= 3.15J 3.28J Total Peak Current The peak current rating can be checked against the transient current measured in the circuit. If the transient is generated by an inductor, the peak current will not be more than the inductor current at the time of switching. Another method for finding the transient current is to use a graphical analysis. When the transient voltage and source impedance is known, a Thevenin equivalent circuit can be modeled. Then, a load line can be drawn on the log - log, V-l characteristic as shown in Figure 4. The two curves intersect at the peak cur- rent value. z s Wv 6 v - FIGURE 4A. EQUIVALENT CIRCUIT Where the current waveshape is different from the exponen- tial waveform of Figure 21 of Section 3, the curves of Figure 5 can be used by converting the pulse duration on the basis of equivalent energy. This is easily done using the con- stants given in Figure 2. For example, suppose the actual current measured has a triangular waveform with a peak current of 10A, a peak voltage of 340V and an impulse dura- tion of 500us. VABISOR V-l CHARACTERISTIC 'V V -v oc /z s LOG VARISTOR CURRENT (A) FIGURE 4B. GRAPHICS/ANALYSIS TO DETERMINE PEAK I FIGURE 4. DETERMINING VARISTOR PEAK CURRENT FROM A VOLTAGE SOURCE TRANSIENT The rated single pulse current, l TM , is the maximum allowable for a single pulse of 8/20us exponential waveform (illustrated in Section 3, Figure 21). For longer duration pulses, l TM should be derated to the curves in the varistor specifications. Figure 5 shows the derating curves for 7mm size, LA series devices. This curve also provides a guide for derating current as required with repetitive pulsing. The designer must consider the total number of transient pulses expected during the life of the equipment and select the appropriate curve. 100 1,000 IMPULSE DURATION < M S) 10,000 FIGURE 5. PEAK CURRENT DERATING BASED ON PULSE WIDTH AND NUMBER OF APPLIED PULSES Then: E = (.5)(10)(340)(500)(10" 6 ) = 850mJ The equivalent exponential waveform of equal energy is then found from: ^TRIANGULAR = E EXP 850mJ = 1 .4 V c It exp The exponential waveform is taken to have equal V c and I values. Then, 850mJ T EXP = 1.4 (340) (10) = 179ns Or: *EXP = 1.4 Where: K* and %' are the values for the triangular waveform and t EX p is the impulse duration for the equivalent exponen- tial waveform. The pulse rise portion of the waveform can be ignored when the impulse duration is five times or more longer. The maxi- mum number of pulses for the above example would exceed 10 4 from the pulse derating curves shown in Figure 5. Power Dissipation Requirements Transients generate heat in a suppressor too quickly to be transferred during the pulse interval. Power dissipation capability is of concern for a suppressor if transients will be occurring in rapid succession. Under this condition, the power dissipation required is simply the energy (watt-sec- onds) per pulse times the number of pulses per second. The 6-5 Designing With Varistors power so developed must be within the specifications shown on the ratings tables. It is to be noted that varistors can only dissipate a relatively small amount of average power and are, therefore, not suitable for repetitive applications that involve substantial amounts of average power dissipation (likewise, varistors are not suitable as voltage regulation devices). Furthermore, the operating values need to be der- ated at temperatures above the absolute maximum limits as shown in Figure 6. AUML, CH, CP CS, ML, RA SERIES 7 BA/BB, CA, DA/DB. - HA, NA, MA, PA, ; LA, "C III 7 :a series ,,111111 -55 50 60 70 80 90 100 110 120 130 140 150 AMBIENT TEMPERATURE (°C) FIGURE 6. CURRENT, ENERGY, POWER RATING vs TEMPER- ATURE Voltage Clamping Selection Transient V-l characteristics are provided in the specifications for all models of varistors. Shown below in Figure 7 are curves for 130V AC rated models of the LA series. These curves indi- cate the peak terminal voltage measured with an applied 8/20us impulse current. For example, if the peak impulse cur- rent applied to a V130LA2 is 10A, that model will limit the tran- sient voltage to no higher than 340V. 10 1 10 2 10 3 PEAK AMPERES 8«0ns WAVESHAPE FIGURE 7. TRANSIENT V-l CHARACTERISTICS OF TYPICAL LA SERIES MODELS If the transient current is unknown, the graphical method of Figure 4 can be utilized. From a knowledge of the transient voltage and source impedance a load line is plotted on the V-l characteristic. The intersection of the load line with the varistor model curve gives the varistor transient current and the value of clamped peak transient voltage. The ability of the varistor to limit the transient voltage is sometimes expressed in terms of a clamp ratio. For exam- ple, consider a varistor applied to protect the power termi- nals of electrical equipment. If high line conditions will allow a rise to 130V AC , then 184V peak would be applied. The device selected would require a voltage rating of 130V ACRMS or higher. Assume selection of a V130LA2 model varistor. The V130LA2 will limit transient voltages to 340V at currents of 10A. The clamp ratio is calculated to be, Clamp Ratio i V c at 10A Peak Voltage Applied 340V 184V = 1.8 The clamp ratio can be found for other currents, of course, by reference to the V-l characteristic. In general, clamping ability will be better as the varistor physical size and energy level increases. This is illustrated in Figure 8 which com- pares the clamping performance of the different Harris Varis- tor families. It can be seen that the lowest clamping voltages are obtained from the 20mm (LA series) and 60mm (BA series) products. In addition, many varistor models are avail- able with two clamping selections, designated by an A, B, or C at the end of the model number. The A selection is the standard model, with B and C selections providing progres- sively tighter clamping voltage. For example, the V130LA20A voltage clamping limit is 340V at 100A, while the V130LA20B clamps at not more than 325V. Summary The five major considerations for varistor selection have been described. The final choice of model is a balance of these factors with device packaging and cost trade-offs. In some applications a priority requirement such as clamp volt- age or energy capability may be so important as to force the selection to a particular model. A summary of varistor prop- erties is provided in Figure 9 for a quick comparison of oper- ating ranges. Failure Modes and Varistor Protection Varistors are inherently rugged and are conservatively rated. Therefore, they exhibit a low failure rate. Nevertheless, the careful designer may wish to plan for potential failure modes and the resultant effects on circuitry being protected. Failure Modes Varistors initially fail in a short-circuit mode when subjected to surges beyond their peak current/energy ratings. They also short-circuit when operated at steady-state voltages well beyond their voltage ratings. This latter mode of stress may result in the eventual open-circuiting of the device due to melting of the lead solder joint. 6-6 Designing With Varistors 6-7 Designing With Varistors When the device fails in the shorted mode the current through the varistor becomes limited mainly by the source impedance. Consequently, a large amount of energy can be introduced, causing mechanical rupture of the package accompanied by expulsion of package material in both solid and gaseous forms. Steps may be taken to minimize this potential hazard by the following techniques: 1) fusing the varistor to limit high fault currents, and, 2) protecting the sur- rounding circuitry by physical shielding, or by locating the varistor away from other components. Fusing the Varistor Varistor fusing should be coordinated to select a fuse that limits current below the level where varistor package dam- age could occur. The location of the fuse may be in the distri- bution line to the circuit or it may be in series with the varistor as shown in Figure 10. Generally, fuse rather than breaker protection is preferred. Breaker tripping may be too slow to prevent excessive fault energy in some applications. I PROTECTED I v line rv i CIRCUIT I 1/1 l I r-r 1 1 i i * i — i L _ _ _ J FIGURE 10. FUSE PLACEMENT FOR VARISTOR PROTECTION In high power industrial circuits the line currents are gener- ally so high as to rule out the use of a line fuse for varistor protection. The fuse may not clear under a varistor fault con- dition and would allow varistor failure. In low power (5-20A) applications it may be feasible to use the line fuse, F L , only. Use of a line fuse, F L , rather than F v , does not present the problem of having the fuse arc voltage being applied across the circuit. Conversely, with F v alone, the fuse arc voltage adds to the varistor voltage, increasing the Vq, the transient clamp voltage. Since some fuses can have peak arc volt- ages in excess of twice peak working voltage, fuse clearing can have a significant effect on protection levels. Another factor in the choice of location is the consequence of system interruption. Fuse location F L will cause a shut- down of the circuit while location F v will not. While the circuit can continue to operate when F v clears, protection no longer is present. For this reason it is desirable to be able to moni- tor the condition of F v . Fusing Example (Light Industrial Application) A process control minicomputer is to be protected from tran- sients on a 115V nominal line. The minicomputer draws 7.5A from the line, which is guaranteed to be regulated to +10% of nominal line voltage. A V130LA20A varistor is chosen on the basis that the worst-case surge current would be a 10/1 000ns pulse of 100A peak amplitude. The rationale for this surge requirement is that the incoming plant distribution system is protected with lightning arrestors having a maximum arrestor voltage of 5kV. Assuming a typical 50n characteristic line impedance, the worst-case transient current through the varistor is 100A. The 1ms impulse duration is taken as a worst-case composite wave estimate. While lightning stroke discharges are typically less than 100us, they can recur in rapid fire order during a 1s duration. From the pulse rating curves of the LA series size 20mm models, it is seen that the V130LA20 single pulse withstand capability at 1ms impulse duration is slightly in excess of 100A. This is adequate for application in areas where lightning activity is medium to light. For heavy lightning activity areas, either a DA or DB series varistor might be desirable to allow a capability of withstanding over 70 transients. In making the choice between the LA series and higher energy series, the designer must decide on the likelihood of a worst-case lightning stroke and resultant fuse replacement should the varistor fail. Assuming a low lightning activity area, the V130LA20A series is a reasonable choice. To coordinate the fuse with the varistor, the single pulse surge rating curve is redrawn as l 2 t vs impulse duration as shown in Figure 11. The l 2 t of the composite 10/1000us impulse is found from:' 1 ' I 2 t= li 2 (10ns) +0.722 i 2 (i (051 -10 M s) When: t (0 5) > 200ms (time for impulse current to decay by 0.5) I 2 t . 0.722 I 2 t (0 5) Where: the first term represents the impulse l 2 t contributed by the 10us rise portion of the waveform and the second term is the l 2 t contributed by the exponential decay portion. Figure 11 shows a cross-hatched area which represents the locus of possible failure of the varistor. This area is equal to an I 2 value of from two to four times that derived from the data sheet peak current pulse life curves. The curve extend- ing beyond the cross-hatched area and parallel to it is where package rupture will take place. The criteria for fuse selection is given below. A) Fuse melts; i.e., opens, only if worst-case transient is exceeded and/or varistor fails. B) If varistor fails, fuse clearing limits l 2 t applied to varis- tor values below that required for package rupture. C) Fuse is rated at 130V RMS . D) Fuse provides current limiting for solid-state devices. Based on the above, a Carbone-Ferraz 12A RMS , 130V RMS , Class FA fuse is tentatively selected. The minimum melting l 2 t and maximum clearing l 2 t curves for the 12A fuse are shown superimposed on the varistor characteristics. This fuse is guaranteed to melt at an l 2 t of 40% above the estimated worst-case transient. Upon melting, clearing l 2 t and clearing time will depend upon available fault current from the 130V RMS line. Table 2 lists clearing times for the selected fuse versus available prospective circuit current. 6-8 Designing With Varistors TABLE 2. 12A FUSE - PROSPECTIVE CURRENT vs CLEARING TIME PROSPECTIVE CURRENT (Arms) CLEARING TIME (ms) 60 8.0 120 5.6 240 3.5 1200 1.3 3600 . i 0.57 As Figure 11 shows, a clearing time of less than 1.5ms is desirable. For fault currents in excess of 1 .2kA, the fuse will clear at less than 24A 2 s and 1 ,3ms. This will prevent varistor package rupturing. However, the distribution line may be "soft," i.e., have a high source impedance at the 60Hz power frequency that limits the fault current to values below 1 .2kA. Then, it is possible that the fuse would not protect the varis- tor package from rupturing, though it would serve to isolate the varistor in any case. Upon further examination of this example, it is clear that the varistor will be protected from package rupturing even if the transient pulse current is 50% greater than that of the assumed value, resulting in an l 2 t of 16A 2 S (Point 2 on Figure 11). Placement of the fuse for this example application could be in the line or in series with the varistor. If in series with the varistor, the line fuse should be a medium to slow speed, such as a "slow blow" type 15A fuse. That would assure a fault in the varistor would be isolated by the varistor fuse without interrupting the line fuse. PT.2 ^ I I 12A F J 5E PT. 1 • ASSUMED WORST CASE TRANSIENT l 2 t I I III I MAX. CLEARING l 2 t 12A FUSE MIN. MELTING l 2 t - PACKAGE RUPTURE - POSSIBLE PACKAGE RUPTURE - DEVICE FAILURE -POSSIBLE DEVICE FAILURE (SHORT CIRCUIT) 10ms 100us 1ms IMPULSE DURATION (s) SINGLE PULSE LIFETIME RATING, 10ms I 2 ! (VI30LA20) FIGURE 11. HARRIS VARISTOR - FUSE COORDINATION CHART Designing With Varistors It is desirable to indicate the status of the varistor fuse if one is used in addition to the line fuse. The circuit shown in Fig- ure 12 senses the presence of voltage across the varistor by use of a photocoupler. When the fuse interrupts the varistor circuit, the LED of the coupler becomes de-energized, and the coupler output signal can be used to annunciate an unprotected condition. Some fuse manufacturers provide indicating means upon fuse operation that may also be used to trip an alarm. FIGURE 12. VARISTOR FUSE STATUS SENSING CIRCUIT In selecting a fuse, the reader is advised to avoid data based on average values or data taken at operating conditions that are grossly different from the actual application. For exam- ple, DC data does not apply when the fuse will be used on an AC circuit. Also, test data taken in a resistive circuit with unity power factor does not hold for low power factor opera- tion. Series and Parallel Operation of Varistors In most cases the designer can select a varistor that meets the desired voltage ratings from standard catalog models. Occasionally the standard catalog models do not fit the requirements either due to voltage ratings or energy/current ratings. When this happens, two options are available: varis- tors can be arranged in series or parallel to make up the desired ratings, or the factory can be asked to produce a "special" to meet the unique application requirement. Series Operation of Varistors Varistors are applied in series for one of two reasons: to pro- vide voltage ratings in excess of those available, or to provide a voltage rating between the standard model voltages. As a side benefit, higher energy ratings can be achieved with series con- nected varistors over an equivalent single device. For instance, assume the application calls for a lead mounted varistor with an V RMS rating of 375V AC and having a l TM peak current capability of 6000A. The \j M requirement fixes the varistor size. Examin- ing the LA series voltage ratings near 375V AC , only 320V and 420V units are available. The 320V is too low and the 420V unit (V420LA40B) results in too high a clamp voltage (V c of 1060V at 100A). For a V130LA20B and a V250LA40B in series, the maximum rated voltage is now the sum of the voltages, or 380V. The clamping voltage, V c , is now the sum of the individ- ual varistor clamping voltages, or 945V at 1 00A. The peak cur- rent capability is still 6500A but the energy rating is now the sum of the individual energy ratings, or 200J. In summary, varistors can be connected in series providing they have identical peak current ratings (Ijm). i e -. same disc diameter. The composite V-l characteristic, energy rating, and maximum clamp voltages are all determined by sum- ming the respective characteristics and/or ratings of the indi- vidual varistors. Parallel Operation of Varistors Application requirements may necessitate higher peak cur- rents and energy dissipation than the high energy series of varistors can supply individually. When this occurs, the logi- cal alternative is to examine the possibility of paralleling varistors. Fortunately, all Harris Varistors have a property at high current levels that makes paralleling feasible. This property is the varistor's series-resistance that is prominent during the "up-turn region" of the V-l characteristic. This up- turn is due to the inherent linear resistance component of the varistor characteristic (see Section 3). It acts as a series bal- ancing, or ballasting, impedance to force a degree of sharing that is not possible at lower current levels. This is depicted in Figure 13. At a clamp voltage of 600V, the difference in cur- rent between a maximum specified sample unit and a hypo- thetical 20% lower bound sample would be more than 20 to 1. Thus, there is almost no current sharing and only a single varistor carries the current. Of course, at low current levels in the range of 10A -100A, this may well be acceptable. 0.5 1 5 10 SO 100 5001000 5000 10000 PEAK CURRENT (A) FIGURE 13. PARALLEL OPERATION OF VARISTORS BY GRAPHICAL TECHNIQUE At high current levels exceeding 1000A, the up-turn region is reached and current sharing improves markedly. For instance, at a clamp voltage of 900V, the respective varistor currents (Figure 13) are 2500A and 6000A, respectively. While far from ideal sharing, this illustration shows the feasi- bility of paralleling to achieve higher currents and energy than achievable with a single model varistor. Practically, varistors must be matched by means of high cur- rent pulse tests to make parallel operation feasible. Pulse testing should be in the range of over 1 kA, using an 8/20us, or similar pulse. Peak voltages must he read and recorded. High current characteristics could then be extrapolated in the range of 100A - 10.000A. This is done by using the mea- sured data points to plot curves parallel to the data sheet curves. With this technique current sharing can be consider- able improved from the near worst-case conditions of the hypothetical example given in Figure 13. 6-10 Designing With Varistors In summary, varistors can be paralleled, but good current sharing is only possible if the devices are matched over the total range of the voltage-current characteristic. In applica- tions requiring paralleling, Harris should be consulted. Some guidelines for series and parallel operation of varistors are given in Table 3. Applications Power Supply Protection Against Line Transient Damage PROBLEM It is desired to prevent failure of the power supply shown in Figure 14B to be used on residential 117V AC lines. A representative transient generator is to be used for test- ing, as shown in Figure 14A. If the transient is applied to the existing circuit, the rectifier will receive high negative voltages, transmitted through the filter capacitor. The LC network is there to prevent FSFI from being transmitted into the power line (as in a TV set), but also serves to reduce the transient voltage. An analysis shows that the transient will be reduced approximately by half, resulting in about 2.5kV instead of 5kV at the rectifier. This is still too high for any practical rectifier, so some sup- pression must be added. It is desirable to use the built-in impedance of the coil to drop the remaining voltage, so the suppressor would best be applied as shown. A selec- tion process for a Harris Varistor is as follows: SOLUTION Steady-State Voltage The 117V AC , 110% high line condition is 129V. The closest voltage rating available is 130V. Energy and Current The 100uH inductor will appear to be about 30£i to the transient. The 30£2 is derived from the inductive reactance at the transient generator source frequency of 10 5 n rad. Taking a first estimate of peak varistor current, 2500V/80O = 31 A. (This first estimate is high, since it assumes varistor clamping voltage is zero.) With a tentative selection of a 130V Harris Varistor, we find that a current of 31 A yields a voltage of from 325V to 380V, depending on the model size, as shown in Figure 15A and Figure 15B. 100nH FIGURE 14A. TRANSIENT GENERATOR FIGURE 14B. TYPICAL POWER SUPPLY CIRCUIT FIGURE 14. POWER SUPPLY PROTECTION TABLE 3. CHECKLIST FOR SERIES AND PARALLEL OPERATION OF VARISTORS SERIES PARALLEL Objective Higher Voltage Capability Higher Energy Capability Non-Standard Voltage Capability Higher Current Capability Higher Energy Capability Selection Required No Yes Models Applicable All, must have same l TM rating. All models Application Range All voltages and currents. All voltages - only high currents, i.e., >100A. Precautions I TM ratings must be equal. Must be identical voltage rated models. Must test and select units for similar V-l characteristics. Effect on Ratings Clamp voltages additive. Voltage ratings additive. Current ratings that of single device. Energy W™, ratings additive. Current ratings function of current sharing as determined graphically. Energy ratings as above in proportion to current sharing. Clamp voltages determined by composite V-l characteristic of matched units. Voltage ratings that of single unit. 6-11 With Varistors PEAK AMPERES 8/20(15 WAVESHAPE FIGURE 15B. FIGURE 15. V130LA VARISTOR V-l CHARACTERISTICS Revising the estimate, I = (2500V - 325V)/80fi = 27.2A. For model V130LA20A, 27.2A coincides closely with a 320V clamping level. There is no need to further refine the estimate of peak current if model 20A remains the final selection. To arrive at an energy figure, assume a sawtooth current waveform of 27A peak, dropping to zero in two time con- stants, or 20us. Energy is then roughly equal to (27A x 320V x 20us)/2, the area under the power waveform. The result is 0.086J, well within the capability of the varistor (70J). Peak current is also within the 6500A rating. 10|is 20(is FIGURE 16B. FIGURE 16. ENERGY APPROXIMATION Model Selection The actual varistor selection is a trade-off between the clamping voltage desired and the number of transient cur- rent pulses expected in the life of the equipment. A 70J rated varistor will clamp at 315V and be capable of han- dling over 10 6 such pulses. An 11J unit will clamp to approximately 385V and be capable of handling over 10 5 such pulses. Furthermore, the clamping voltage deter- mines the cost of the rectifier by determining the voltage rating required. A smaller, lower cost varistor may result in a more expensive higher voltage rectifier diode. SCR Motor Control PROBLEM The circuit shown in Figure 17 experiences failures of the rectifiers and SCR when the transformer primary is switched off. The manufacturer has tried 600V compo- nents with little improvement. FIGURE 17. SCR MOTOR CONTROL 6-12 Designing With Varistors SOLUTION Add a varistor to the transformer secondary to clamp the transformer inductive transient voltage spike. Select the lowest voltage Harris Varistor that is equal to or greater than the maximum high line secondary AC voltage. The V1 30LA types fulfills this requirement. Determine the peak suppressed transient voltage pro- duced by the transient energy source. This is based on the peak transient current to the suppressor, assuming the worst-case condition of zero load current. Zero load cur- rent is normally a valid assumption. Since the dynamic transient impedance of the Harris Varistor is generally quite low, the parallel higher impedance load path can be neglected. Since transient current is the result of stored energy in the core of the transformer, the transformer equivalent circuit shown in Figure 18 will be helpful for analysis. The stored inductive energy is: fVYY\ RIMAR L -VV\- MUTUAL INDUCTANCE VpRiMARY REPRESENTED IDEAL TRANSFORMER FIGURE 18. SIMPLIFIED EQUIVALENT CIRCUIT OF A TRANS- FORMER The designer needs to know the total energy stored and the peak current transformed in the secondary circuit due to the mutual inductance, L M . At no load, the magnetizing current, (l NL ), is essentially reactive and is equal to l M . This assumes that the primary copper resistance, leakage reactance and equivalent core resistive loss components are small compared to L M . This is a valid assumption for all but the smallest control transformers. Since l NL is assumed purely reactive, then: and 'm = 'nl l NL can be determined from nameplate data. Where nameplate is not available, Figure 19 and Figure 20 can guide the designer. Assuming a 3.5% value of magnetizing current from Fig- ure 20 for a 20kVA transformer with 480V AC primary, and 1 20V AC secondary: i - |Q035) 20kVA 'M- <00J5) 480V = 1.46A 50.. 60 Hz FIGURE 20. MAGNETIZING WITH HIGH SILICON LOOP CORE 10 10 2 10 3 10 4 TRANSFORMER RATING (kVA) ORMERS OR SQUARE 6-13 Designing With Varistors V130LA10A selection, 295V with the V130LA20B. This allows the use of 300V rated semiconductors. Safety mar- gins exist in the above approach as a result of the following assumptions: 1. All of the energy available in the mutual inductance is transferred to the varistor. Because of core hysteresis and secondary winding capacitance, only a fraction less than two-thirds is available. 2. The exciting current is not purely reactive. There is a 10% to 20% safety margin in the peak current assump- tion. After determining voltage and peak current, energy and power dissipation requirements must be checked. For the given example, the single pulse energy is well below the V130LA20B varistor rating of 70J at 85°C maximum ambient temperature. Average power dissipation requirements over idling power are not needed because of the non-repetitive nature of the expected transient. Should the transient be repet- itive, then the average power is calculated from the product of the repetition rate times the energy of the transient. If this value exceeds the V1 30LA20B capability of 1 .0W, power varistors of the HA, DA, or DB Series may be required. Should the ambient temperature exceed 85°C or the surface temperature exceed 85°C, the single pulse energy ratings and the average power ratings must be derated by the appropriate derating factors supplied on the data sheet. Contact Arcing Due to Inductive Load PROBLEM To extend the life of the relay contacts shown in Figure 21 and reduce radiated noise, it is desired to eliminate the contact arcing. ' RELAY 28V DC C c = STRAY CAPACITANCE L = RELAY COIL INDUCTANCE R c > RELAY COIL RESISTANCE FIGURE 21. RELAY CIRCUIT When relays or mechanical switches are used to control inductive loads, it is necessary to use the contacts at only about 50% of their resistive load current rating to reduce the wear caused by arcing of the contacts. The energy in the arcing is proportional to the inductance and to the square of the current. Each time the current in the inductive load is interrupted by the mechanical contacts, the voltage across the contacts builds up as -L di/dt. When the contacts arc, the voltage across the arc decreases and the current in the coil can increase somewhat. The extinguishing of the arc causes an additional voltage transient which can again cause the contacts to arc. It is not unusual for the restriking to occur several times with the total energy in the arc several times that which was originally stored in the inductive load. It is this repetitive arcing that is so destructive to the contacts. In the example, R c is 30Q and the relay contacts are con- ducting nearly 1A. The contacts will draw an arc upon opening with more than approximately 0.4A or 12V. The arc continues until current falls below 0.4A. SOLUTION To prevent initiation of the arc, it is necessary to reduce the current and voltage of the contacts below the arc threshold levels at the time of opening, and then keep them below breakdown threshold of the contacts as they open. Two obvious techniques come to mind to accomplish this: 1) use of a large capacitor across the contacts, and 2) a voltage clamp (such as a varistor). The clamp technique can be effective only when the minimum arc voltage exceeds the supply voltage. In this example a clamping device operating above the sup- ply voltage will not prevent arcing. This is shown in Figure 22. o 50 < VOLTAGE ARC ABOVE VOLTAGE CLAMP BELOW ARC VOLTAGE 25 50 75 100 BREAK TIME (us) FIGURE 22. VOLTAGE CLAMP USED AS ARC SUPPRESSOR The capacitor technique requires the capacitance to be sufficiently large to conduct the inductor current with a voltage rate-of-rise tracking the breakdown voltage rate- of-rise of the contacts as they mechanically move apart. This is shown in Figure 23(A). The limitations in using the capacitor approach are size and cost. This is particularly true for those cases involving large amounts of inductive stored energy. Furthermore, the use of a large capacitor alone creates large discharge currents upon contact reclosure during contact bouncing. As a result, the contact material may melt at the point of contact with subse- quent welding. To avoid this inrush current, it is customary to 6-14 Designing With Varistors add a series resistor to limit the capacitive discharge current. However, this additional component reduces the network effectiveness and adds additional cost to the solution. A third technique, while not as obvious as the previous two, is to use a combination approach. This technique shown in Figure 23B parallels a voltage clamp component with an R-C network. This allows the R-C network to prevent the low volt- age initial arcing and the clamp to prevent the arcing that would occur later in time as the capacitor voltage builds up. This approach is often more cost effective and reliable then using a large capacitor. 25 50 75 BREAK TIME ( M s) FIGURE 23A. R-C ARC SUPPRESSION V V SMALL C WITH R AND VOLTAGE CLAMP COMBINATION 25 50 75 100 BREAK TIME (us) FIGURE 23B. R-C AND CLAMP ARC SUPPRESSION FIGURE 23. RELAY ARC VOLTAGE SUPPRESSION TECH- NIQUES Also, with AC power relays the impedance of a single large R-C suppressor might be so low that it would allow too much current to flow when the contacts are open. The combination technique of a small R-C network in conjunction with a varistor is of advantage here, too. In this example a 0.22uF capacitor and 10£2 resistor will sup- press arcing completely, but by reducing the capacitance to 0.047uF, arcing will start at 70V. Thus, to use a varistor as a clamp in conjunction with the R-C network, it must suppress the voltage to below 70V at 1 A and be capable of operating at a steady-state maximum DC volt- age of 28V + 10%, or 30.8V (assumes a ±10% regulated 28V DC supply). The three candidates that come closest to meeting the above requirement are the MA series V39MA2B model and the ZA series V39ZA1 and V39ZA05 models, all of which have maximum steady-state DC voltage ratings of 31V. The V39MA2B and V39ZA05 V-l characteristics at 1A shows a maximum voltage of 73V, while the V39ZA1 characteristic at 1A shows a maximum voltage of 67V. Thus, the latter varistor is selected. Use of a 0.068uF capacitor in place of the 0.047uF previously chosen would allow use of the V39MA2B or V39ZA05. Placing only a Harris Varistor rated for 31 V DC across the contacts results in arcing up to the 66V level. By combin- ing the two, the capacitor size and voltage rating are reduced and suppression complete. Besides checking the varistor voltage and arcing elimination, the designer should review energy and peak current require- ments. Varistor energy is determined from a measurement of the coil inductance and the calculation E = 1/2 Li 2 . Peak cur- rent, of course, is under 1A. Power dissipation is negligible unless the coil is switched often (several times per minute). In those cases where multiple arcs occur, the varistor energy will be a multiple of the above 1/2 Li 2 value. The peak current is well within the rating of either the MA or ZA series of varistors, but the number of contact operations allowable for either varistor is a function of the impulse duration. This can be estimated by assuming a L/R c time constant at the 1 A or peak current value. Since the voltage across the varis- tor is 67V at 1 A, the varistor static resistance is 67a. The coil R c value is 28V/1 A, or 28Q. The coil inductance was found to be 20mH. Thus, the approximate time constant is: , ,„ 20mH „,„ From the pulse rating curves of the V39ZA1 model, the num- ber of allowable pulses exceeds 100 million. Noise Suppression PROBLEM Switching of a small timer motor at 1 20V, 60Hz, was causing serious malfunctions of an electronic device operating from the same power line. Attempts were made to observe the transient noise on the line with an oscilloscope as the first step in curing the problem. Observed waveforms were "hash," i.e., not readily identifiable. Noise is an electromechanical system is a commonly experi- enced result of interrupting current by mechanical contacts. When the switch contacts open, a hot cathode arc may occur if the current is high enough. On the other hand, low current will permit switch opening without an arc, but with ringing of circuit resonances. As a consequence, voltages can exceed the contact gap breakdown resulting in a replica of the old spark gap transmitter. It is the low current case that produces the most serious noise disturbances which can result in mal- functions or damage to electrical equipment. These pulses cause noise problems on adjacent lines, trigger SCR's and triacs, and damage semiconductors. In addition, they can disrupt microprocessor operation causing memory to be lost and vital instructions to be missed. 6-15 Designing With Varistors SOLUTION A test circuit (Figure 24) was set up with lumped elements replacing the measured circuit values. The motor impedance was simulated by R,, L,, and C,, and the AC line impedance by L 2 and C 2 . A DC source allowed repeatable observations over the full range of current that could flow through the switch in the normal AC operation. A diode detector was used to observe the RF voltage developed across a 2" length of wire (50nH of inductance). v cc -^Z= 5. H -C, 80pF 6.8H ■ 2" AWG #22 WIRE ■ 10V/cm 200us/cm UPPER V,: 200V/cm LOWER V BF : 20V/cm t: 0.2ms/cm FIGURE 26. VARISTOR PROTECTED CONTACTS Protection of Transistors Switching Inductive Loads PROBLEM The transistor in Figure 27 is to operate a solenoid. It may operate as frequently as once per second. The circuit (with- out any suppression) consistently damages the transistor. FIGURE 24. TEST CIRCUIT The supply is set at 25mA to represent the peak motor current in normal 120V AC operation. As switch Si was opened, the waveform in Figure 25 was recorded. Note the "showering arc" effect. The highest breakdown voltage recorded here is 1020V, and the highest RF detector out- put (shown in the lower trace) is 32V. I UPPER V,: 200V/cm LOWER V RF : 20V/cm t: 0.2ms/cm FIGURE 25. UNPROTECTED CONTACTS Obviously, some corrective action should be taken and the most effective one is that which prevents the repeated breakdown of the gap. Figure 26 shows the waveform of Vt (upper trace) and V RF (lower trace) for the same test conditions with a Harris Varistor, type V130LA10A, con- nected directly across the switch terminals. The varistor completely eliminates the relaxation oscillations by hold- ing the voltage below the gap breakdown voltage (about 300V) while dissipating the stored energy in the system. PERIOD OF HIGH SOA FIGURE 27A. BASIC SOLENOID CIRCUIT V c > COLLECTOR EMITTER VOLTAGE FIGURE 27B. SOLENOID CIRCUIT WITH VARISTOR PROTECTION FIGURE 27. TRANSISTOR SWITCHING OF AN INDUCTIVE LOAD The inductor drives the collector voltage up when the tran- sistor base is grounded (turning "off"). The inductor forces current to flow until the energy stored in its field is dissi- pated. This energy is dissipated in the reverse bias condi- tion of the transistor and is sufficient to cause breakdown (indicated by a sudden collapse of collector voltage during the pulse). Designing With Varistors SOLUTION This condition can be eliminated either by shunting the transistor with a suppressor or by turning it on with a varistor connected collector-to-base. The first method will considerably reduce the demands upon the safe operating area (SOA) of the transistor. If the voltage is kept below its breakdown level, all energy will be dissipated in the suppressor. The latter method will cause the transistor to once again dissipate the stored energy, but in the forward- bias state in which the transistor can safely dissipate limited amounts of energy. The choice is determined by economics and reliability. A suppressor connected collector-emitter (C-E) will be more expensive than one connected C-B, since it is required to absorb more energy, but will allow the use of a transistor with reduced SOA. If a collector-emitter varistor is used in the above example, it is required to withstand 28.6V DC worst-case (26 + 10% regu- lation). The stored energy is 1/2 Li 2 or 1/2 (0.20) (0.572) 2 = 0.0327J. The energy contributed by the power supply is roughly equal to this (coil voltage = supply voltage, since varis- tor clipping voltage = 2 x supply voltage). Ignoring coil resis- tance losses for a conservative estimate, varistor energy dissipation is 0.065J per pulse. The peak current will be 0.572A, the same as the coil current when the transistor is switched off. If the transistor operates once per second, the average power dissipation in the varistor will be 0.065W. This is less than the 0.20W rating of a small 31V DC varistor (V39ZA1). From the data sheet it can be seen that if the device temperature exceeds 85°C, derating is required. The nonrecurrent joule rating is 1 .5J, well in excess of the recurrent value. To determine the repetitive joule capabil- ity, the current pulse rating curves for the ZA series must be consulted. Two are shown in Figure 28. To use Figure 28, the impulse duration (to the 50% point) is estimated from the circuit time constants and is found to be 1240|is. From Figure 28A, for this example, the 7mm V39ZA1 would not be limited to a cumulative number of pulses. In cases where the peak current is greater and intersects with the recommended pulse life curves, the designer must determine the maximum number of operations expected over the life of the circuit and confirm that the pulse life curves are not exceeded. Figure 28B shows the curves for the larger, 14mm V39ZA6 device and, illustrates the resultant higher capability in terms of number of transients for a given peak pulse current and duration. Also, it may be necessary to extrapolate the pulse rating curves. This has been done in Figure 29 where the data from Figure 28B is transposed. At low currents the extrap- olation is a straight line. Finally, the V-l characteristics curves must be consulted to determine the varistor maximum clamping voltage in order to select the minimum transistor breakdown voltage. In this example, at 0.572A the V39ZA6 (if chosen) provides a maximum of 61V requiring that the transistor have about a 65V or 70V capability. 100 1,000 IMPULSE DURATION < M s) FIGURE 28A. ZA SERIES V18ZA1 TO V68ZA2 (MODEL SIZE 7mm) I o o IB s 100 1,000 10,00( IMPULSE DURATION (us) FIGURE 28B. ZA SERIES V18ZA3 TO V68ZA10 (MODEL SIZE 14mm) < i UJ I p SERIES V18ZA3 TO V68Z A10 ZA ■» " NOTE - PULS I RATINI 3 CURVE FOR 1,2 40ms PU LSE WID TH I I I I I I 10 3 10 4 10 5 10 6 10 7 10 8 10 9 10 1 NUMBER OF PULSES FIGURE 29. EXTRAPOLATED PULSE RATING CURVES 6-17 Designing With Varistors Motor Protection Frequently, the cause of motor failures can be traced to insu- lation breakdown of the motor windings. The source of the transients causing the breakdown may be from either inter- nal magnetic stored energy or from external sources. This section deals with the self-generated motor transients due to motor starting and circuit breaker operation. Externally gen- erated transients and their control are covered in Section 2. In the case of DC motors the equivalent circuit consists of a single branch. The magnetic stored energy can be easily calculated in the armature or field circuits using the name- plate motor constants. With AC induction motors the equiva- lent magnetic motor circuit is more complex and the circuit constants are not always given on the motor nameplate. To provide a guide for motor protection, Figures 30, 31, 32 were drawn from typical induction motor data. While the actual stored energy will vary according to motor frame size and construction techniques, these curves provide guidance when specific motor data is lacking. The data is conservative as it assumes maximum motor torque, a condition that is not the typical running condition. Stored energy decreases con- siderably as the motor loading is reduced. Experience with the suppression of magnetic energy stored in transformers indicates that Harris Varistors may be used at their maxi- mum energy ratings, even when multiple operations are required. This is because of the conservatism in the applica- tion requirements, as indicated above, and in the varistor rat- ings. Thus, no attempt is made to derate the varistor for multiple operation because of the random nature of the tran- sient energy experienced. 40 60 80 100 200 400 600 8001000 MOTOR (hp) NOTES: 1. Y connected 60Hz. 2. Energy at max torque slip speed. 3. See Figure 33 for varistor circuit placement. FIGURE 30. STORED ENERGY CURVES FOR TYPICAL WYE- CONNECTED INDUCTION MOTOR 60 80 100 200 400 600 800 1000 MOTOR (hp) NOTES: 1 . Delta connected at 60Hz. 2. Energy at maximum torque slip speed. 3. See Figure 33 for varistor circuit placement. FIGURE 31. STORED ENERGY CURVES FOR TYPICAL DELTA- CONNECTION INDUCTION MOTOR 40 60 80 100 200 400 600 8001000 MOTOR (hp) NOTES: 1 . 60Hz, see Figure 33 for varistor circuit placement. 2. Energy at start, i.e., SLIP = 1 . 3. Induction motor. 4. 2, and 4 pole motors. FIGURE 32. STORED ENERGY CURVES FOR A TYPICAL MOTOR WITH STALLED ROTOR As an aid in selecting the proper operating voltage for Harris Varistors, Table 4 gives guidelines for wye-connected and delta-connected motor circuits at different line-to-line applied voltages. Figure 33 provides guidance in proper placement of the varistor. Interruption of motor starting currents presents special prob- lems to the user as shown in Figure 32. Since the stored mag- netic energy values are approximately 10 times the running values, protection is difficult at the higher horsepower levels. Often the motor is started by use of a reduced voltage which 6-18 Designing With Varistors will substantially reduce the stored energy. A reduction in start- ing current of a factor of two results in a four-fold reduction in stored energy. If a reduced voltage starter is not used, then a decision must be made between protection for the run condition only, and the condition of locked rotor motor current. For most applications, the starting condition can be ignored in favor of selecting the varistorforthe worst-case run condition. PROBLEM To protect a two-pole, 75hp, 3$, 460V RMS line-to-line wye- connected motor from interruption of running transients. Specific Motor Data Is Not Available SOLUTION Consult Figure 30 along with Table 4. Standard varistors having the required voltage ratings are the 320V RM g rated models. This allows a 20% high-line voltage condition on the nominal 460V line-to-line voltage, or 266V line-neutral voltage. Figure 30 shows a two-pole 75hp, wye-connected induction motor, at the running condition, has 52J of stored magnetic energy per phase. Either a V320PA40 series or a V321HA32 series varistor will meet this requirement. The HA series Harris Varistor provides a greater margin of safety, although the PA series Harris Varistor fully meets the application requirements. Three varistors are required, connected directly across the motor terminals as shown in Figure 33. V VARISTOH- J^L-L FIGURE 33A. WYE CONNECTED 8 Power Supply Crowbar Occasionally it is possible for a power supply to generate excessively high voltage. An accidental removal of load can cause damage to the rest of the circuit. A simple safeguard is to crowbar or short circuit the supply with an SCR. To pro- vide the triggering to the SCR, a high-voltage detector is needed. High voltage avalanche diodes are effective but expensive. An axial leaded Harris Varistor provides an effec- tive, inexpensive substitute. PROBLEM In the circuit of Figure 34, the voltage, without protection, can exceed twice the normal 240V peaks, damaging com- ponents downstream. A simple arrangement to crowbar the supply is shown. "VAHISTOR ■ V L-L FIGURE 33B. DELTA CONNECTED FIGURE 33. VARISTOR - 3$ INDUCTION MOTOR CIRCUIT PLACEMENT C106D NORMAL VOLTAGE < 240V PEAK ABNORMAL VOLTAGE > 400V PEAK FIGURE 34. CROWBAR CIRCUIT The supply shown can provide 2A RMS of short-circuit cur- rent and has a 1A circuit breaker. A C106D SCR having a 4A RMS capability is chosen. Triggering will require at least 0.4V gate-to-cathode, and no more than 0.8V at 200uA at 25°C ambient. SOLUTION Check the MA series Harris Varistor specifications for a device capable of supporting 240V peak. The V270MA4B can handle V 2 (171V RMS ) = 242V. According to its specification of 270V ±10%, the V270MA4B will conduct 1 mA DC at no less than 243V. The gate-cathode resistor can be chosen to provide 0.4V (the minimum trigger voltage) at 1mA, and the SCR will not trigger below 243V. Therefore, R GK should be less than 400£i. The highest value 5% tolerance resistor falling below 400£i is a 360Q resistor, which is selected. Thus, R GK is 378Q maximum and 342£1 minimum. Minimum SCR trigger voltage of 0.4V requires a varistor of 0.4V/378S}, or 1.06mA for a minimum varistor voltage of =245V. The maximum voltage to trigger the circuit is dependent upon the maximum current the varistor is required to pass to trigger the SCR. For the C106 at 25°C, this is determined by calculating the maximum current required to provide 0.8V across a parallel resistor comprised of the 360fi R GK selected and the equivalent gate-cathode SCR resistor of 0.8V/200uA, since the C106 requires a maximum of 200uA trigger current. The SCR gate input resistance is 4kf2 and the minimum equivalent gate-cathode resistance is the parallel combination of 4kOand R GK (min). or 36052 -5%, 342£2. The parallel 6-19 Designing With Varistors combination is 315f2. Thus, Ivaristor tor maximum voltage-to-trigger the C106 is 0.8V/315Q, or 2.54mA. According to the specification sheet for the V270MA4B, the varistor will not exceed 330V with this current. The circuit will, therefore, trigger at between 245 and 330V peak, and a 400V rated C106 can be used. The reader is cautioned that SCR gate characteristics are sensitive to junction temperatures, and a value of 25°C for the SCR temperature was merely chosen as a convenient value for demonstrating design procedures. The maximum energy per pulse with this waveform is determined as approximately 1/2 x K x l PK x V PK x t (dura- tion of 1/2 wave pulse), or 0.52mJ for this example. Since the voltage does not drop to zero in this case, the SCR remains on, and the varistor sees only one pulse; thus, no steady-state power consideration exists. General Protection of Solid State Circuitry, Against Transients On 117V AC Lines PROBLEM Modern electronic equipment and home appliances con- tain solid state circuitry that is susceptible to malfunction or damage caused by transient voltage spikes. The equip- ment is used in residential, commercial, and industrial buildings. Some test standards have been adopted by var- ious agencies (see Sections 1 and 7), and further defini- tion of the environment is underway by the IEEE and other organizations. The transients which may occur on residential and com- mercial AC lines are of many waveshapes and of varying severity in terms of peak voltage, current, or energy. For suppressor application purposes, these may be reduced to three categories. First, the most frequent transient might be the one represented by a 30kHz or 100kHz ring wave. This test surge is defined by an oscillatory exponentially decaying voltage wave with a peak open circuit voltage of 6kV. This wave is considered representative of transients observed and reported by studies in Europe and North America. These transients can be caused by distant lightning strikes or distribution line switching. Due to the relatively high impedance and short duration of these transients, peak current and surge energy are lower than the second and third categories. The second category is that of surges produced by nearby lightning strokes. The severity of a lightning stroke is char- acterized in terms of its peak current. The probability of a TABLE 4. PREFERRED VARISTOR VOLTAGE RATINGS FOR DELTA- AND WYE-CONNECTED MOTORS RMS Line Voltage (Line-Line) 230 380 460 550 600 Delta Connected Applied V. Varistor Ratings 230 250/275 380 420/480 460 510/575 550 575/660 600 660 Y Connected Applied V. Varistor Ratings 133 150 220 250/275 266 320 318 420 346 420 TABLE 5. HARRIS VARISTOR SELECTION GUIDELINE FOR 117V AC APPLICATIONS APPLICATION TYPE DUTY CYCLE LOCATION EXAMPLE SUGGESTED MODEL Light Consumer Very Low A Mixer/Blender V130LA2orLA5 Consumer Low A Portable TV V130LA10A Consumer Medium A Console TV/PC V130LA20A Light Industrial Medium B Copier V130LA20A orBorC Industrial Medium B Small Computer V130PA20A orC, HA32 Industrial High B Large Computer V131DA40 or DB40 Industrial High B Elevator Control V151DA40 or DB40 6-20 Designing With Varistors direct stroke of a given severity can be determined. How- ever, since the lightning current divides in many paths, the peak current available at an AC outlet within a building is much less than the total current of the stroke. The stan- dard impulse used to represent lightning and to test surge protective devices is an 8/20|iS current waveshape as defined by ANSI Standard C68.2, and also described in ANSI/IEEE Standard C62.41-1991 and IEC 664-1 (1992). A third category of surges are those produced by the dis- charge of energy stored in inductive elements such as motors and transformers. A test current of 10/1 000ns waveshape is an accepted industry test impulse and can be considered representative of these surges. Although no hard-and-fast rules can be drawn as to the category and severity of surges which will occur, a helpful guideline can be given to suggest varistors suitable in typ- ical applications. The guideline of Table 5 recognizes considerations such as equipment cost, equipment duty cycle, effect equip- ment downtime, and balances the economics of equip- ment damage risk against surge protection cost. Reference [1] Kaufman, R., "The Magic of l 2 t," IEEE Trans. IGA-2, No. 5, Sept.-Oct. 1966. > w O O ii 6-21 TVS 7 VARISTOR TESTING PAGE VARISTOR TESTING 7-3 Introduction 7-3 Test Objectives 7-3 Measurement of Varistor Characteristics 7-4 Varistor Rating Assurance Tests 7-8 Mechanical and Environmental Testing of Varistors 7-9 Equipment for Varistor Electrical Testing 7-9 Test Waves and Standards 7-10 References 7-14 IP 7-1 Varistor Testing Introduction As with any device, metai-oxide varistors possess a number of parameters which can be identified and measured in sev- eral ways. However, to minimize testing effort, the test parameters should be reduced to the essential few. Also, tests should be conducted in a standard way to assure cor- relation of measured values between maker and user. The essential varistor parameters are defined in Section 3. This section will detail the tests of these varistor parameters, describe suitable test methods using simplified test circuits, and list some available test equipment. It should be noted that all tests are performed at 25°C, unless otherwise specified. Also, the test circuits and meth- ods given herein are intended as a general guide only, and may not be generally applicable to the test equipment avail- able to the user. Since the tests frequently entail high volt- ages and currents, the user must exercise appropriate safety precautions. Test Objectives Varistor testing that would be undertaken by a user will depend considerably on prior knowledge of both the device and the application. Factors are the relative severity of the application (both electrical and environmental), the number of devices to be used, and the possible adverse effect of device misapplication or malfunction. Further considerations are resources available to the user and the economics of alternate uses of those resources versus more extensive varistor testing. Equipment makers designing transient pro- tection into their products will have different objectives in varistor testing than a user simply adding a few varistors to existing equipment as a protective step. Finally, the user may have different test requirements depending on which point in the cycle of system design or component evaluation and procurement the testing is being done. Engineering Evaluation For the original equipment maker, the process of evaluating and procuring a new component begins with an initial evalu- ation of the component itself. Typically, the circuit or systems engineer will obtain a few samples of the candidate compo- nent for evaluation in the prototype equipment design. He may seek recommendations from his component engineer in selecting from devices available in the market. It is important to focus on the key characteristics and ratings to determine if the component can perform as expected. Typically, varistor voltage, clamping voltage, standby current, insulation resis- tance, and capacitance of the samples should be measured according to the methods given in Measurement of Varistor Characteristics section. Assuming that a varistor type has been selected according to the design application examples of Section 4, the engineer obviously will verify that the com- ponent performs as expected when placed in the bread- board circuit. Also, it should be verified that variation of these parameters within their specification values are con- sistent with the application requirements. The surge current, or energy, and waveshape available in the circuit together with its frequency of occurrence should be measured or computed. These characteristics of the expected transients should then be checked against the pulse lifetime and the power dissipation ratings of the selected varistor type. Where suitable equipment is available, the rating of the varistor may be verified by injections of transients into the varistor alone or into the prototype circuit. See Equipment for Varistor Electrical Testing and Test Waves and Standards in this section for a discussion of transient test equipment and test waves. Product Qualification In some user organizations, selection and evaluation of the varistor as a component may pass to a specialized group that evaluates component engineering and reliability. The final output of this evaluation will be a purchase specification detailing the mechanical and electrical requirements and rat- ings of the component, and possible approved sources for the part. A product qualification plan often will be used to detail the electrical and environmental tests to which a sam- ple of the candidate component may be subjected and which it must pass in order to be approved. Frequently the manu- facturer will be asked to supply supporting data for his in- house testing to supplement and minimize the qualification testing. The suggested electrical characteristics tests are (with appropriate conditions and limits): nominal varistor volt- age, V N ; maximum clamping voltage, Vq, DC standby cur- rent, l D (optional, especially for AC applications); insulation resistance; and capacitance. These characteristics will be measured frequently in the component/equipment cycle thereafter, and care should be exercised that they are nei- ther too many and complex nor too few to be meaningful to the application. Reliability requirements of operating condi- tions and expected life will sometimes be specified and usu- ally tested for early in the qualification phase of the component. These tests may be performed at special condi- tions of environment or temperature to stress the component as proof of its intended use or design capability. A test to insure surge current withstand capability may be included in the qualification plan. This test must be carefully performed and specified (by using either 8/20us or 10/1 000ns wave- shapes) in line with the recommendations of Section 3 and consistent with the pulse lifetime rating chart of the varistor selected. Other qualification tests may be used to ensure mechanical integrity, humidity resistance, solderability, and terminal/lead strength. These tests should be of a standard nature wherever possible to assure reproducibility. Incoming Inspection Once the component has been qualified, the equipment maker will wish to verify that shipments received consist of correct parts at the expected quality level. Shipments will be sample-tested to assure correct markings, appearance, finish, and major or critical electrical parameters. It is especially desirable to prevent material with incorrect voltage characteristics from entering assembly operations so as to minimize troubleshooting and rework. For incoming inspection of Harris Varistors, it is recommended that sample testing include nominal varistor voltage, V N , tested against 7-3 Varistor Testing the minimum and maximum voltages specified on the purchase drawing/specification. Components below specification limits may lead to premature degradation or circuit failure. If above specification, they may not deliver the required protection from transients and may possibly allow other failures. Other electrical sampling tests frequently performed can include insulation resistance and capacitance. Tests such as maximum clamping voltage, V c , and DC standby current, l , are usually checked only on a periodic audit basis. Field Maintenance Field maintenance testing is done to verify that the varistor is still providing the intended protection function or, in the case of sensitive circuit applications, that the varistor has not degraded. Since the usual change of Harris Varistor characteristics when overstressed is toward lower resistance, it is very unlikely that the protection function will deteriorate unless the electrode system is damaged. The varistor should be physically examined for loose leads, charred or broken areas in the encapsulant, solder dribbles on the leads, or other evidence of overheating damage. If physically acceptable, the varistor may be tested electrically. The nominal varistor voltage should be tested against the minimum limits for the model using the method described in the Nominal Varistor Voltage V N section. If the varistor is open, short, or more than 10% outside either limit, it should be discarded. The DC standby current also should be measured. If more than twice the specification, the varistor is significantly degraded and should be discarded. If the varistor is physically sound and shows no evidence of degradation in these electrical tests, it is fully functional. Measurement of Varistor Characteristics^ Nominal Varistor Voltage V N This is measured at a DC test current, l N of 1mA for product models. A simplified circuit for instrumenting this test, shown in Figure 1, is suitable for varistors up through a rating of 300V RM s- Above the 300V RMS rating, a higher supply voltage will be needed. Resistor R1 has a dual purpose. In conjunction with the variable voltage supply, E1, it forms a quasi-current source providing up to 6mA when switch S1 is closed. Also, R1 is used as a current sensor to measure current flowing through the varistor-under-test. To use the circuit, the operator places switch S2 in position I and S3 into position V N . A test device is then inserted into the socket and S1 is closed. E1 is then adjusted to obtain a reading of 100V ±5V on the digital voltmeter. Approximately 1mA of current will be flowing in R1. When switch S2 is placed in position V, the varistor voltage will be indicated on the voltmeter. The values of R1 and E1 supply voltage can be scaled appropriately for other voltage-current test points. If the varistor voltage test is implemented on automatic test equipment, a "soak" time of 20ms minimum should be allowed after application of test current before voltage mea- surement. This is necessary to allow varistor voltage to set- tle toward a steady-state value. Figure 2 illustrates the time response of a specimen varistor with a constant 1 .0mA cur- rent applied. As can be seen, the varistor voltage initially may rise to a value up to 6% greater than final. With a 20ms or greater soak time, the measured value will differ by less than 2% from the steady-state value. FIGURE 1. SIMPLIFIED CIRCUIT FOR VARISTOR VOLTAGE AND DC STANDBY CURRENT TESTS V(T) 5V/DIV FIGURE 2. VOLTAGE-TIME V(T) CHARACTERISTICS OF A HARRIS VARISTOR (V130LA10A) OPERATING AT A CONSTANT DC CURRENT OF 1 .0mA For varistor models that are commonly used on 60Hz power lines, the V N limits may be specified for a 1.0mA peak AC current applied. If an AC test is preferred by the user, a schematic approach similar to that shown in Figure 1 is used, except an AC Variac™ is substituted for the DC power supply, and an oscilloscope is substituted for the voltmeter. This circuit is equivalent to that of a typical curve tracer instrument. To avoid unnecessary concern over minor measurement anomalies, three behavioral phenomena of metal-oxide varistors should be noted. First, it is normal for the peak varistor voltage measured with AC current to be about 2% to 5% higher than the DC value, as illustrated by Figure 3. This "AC-DC difference" is to be expected, since the one-quarter cycle period of a 60Hz wave is much less than the 20ms minimum settling time required for DC readout. Second, it is normal for the varistor voltage to increase slightly when first subjected to electrical current, as shown in Figure 4. This might be considered a "break-in" stabilization of the varistor characteristics. During normal measurement the voltage shift typically is less than 1%. This voltage shift is of little consequence for most measurement purposes but might be noticeable when viewing a DVM as in the test method of Figure 1. The visual DVM observation should be made shortly after power is applied, with measurement to not more than three significant figures. 7-4 Varistor Testing DC / AC 60t Iz 130V o us RATE PRODUCT MEDIUM VOLTAGE —11— MATE RIAL V(T) 5V/DIV I, CURRENT (A) FIGURE 3. AC AND DC CHARACTERISTIC CURVES ■■■■■«■■■ ■ifliRKinnfiifnininini nuiiiiiiiiiiiuiiiiiiiiiuiiu 1NNMHKMMUI ■■■ mmm mmm mmm ■■■■ T, 50ms/DIV FIGURE 4. (V130LA10A) VARISTOR VOLTAGE FOR THE INITIAL CYCLES OF 60Hz OPERATION AT A PEAK CURRENT OF 1.0mA MM 1 ■in 10A/DIV in mm 100V/DIV if ifi^' m ■■■ mm* ■ HI m ■■■ ■ mm ■ ■:=■ ■3ME3 Hill ■■■■ mmm ■Hi BBSS! ■■■■■ ■■■■■ 11111 *■■■■ ■■■£= ■■■SI 10 M s/DIV FIGURE 5A. 8/20ns, WAVE l P = 50A, V P = 315V FIGURE SB. 10/1000ns, WAVE l P = 50A, V c = 315V FIGURE 5. TYPICAL CLAMPING VOLTAGE TEST WAVEFORMS (HARRIS VARISTOR TYPE V130LA10A) Third, it is normal for the varistor voltage-current characteristic to become slightly asymmetrical in polarity under application of DC electrical stress over time. The varistor voltage will increase in the same direction as the polarity of stress, while it will be constant or will decrease in the opposite polarity. This effect will be most noticeable for a varistor that has been subjected to unipolar pulse stresses or accelerated DC life tests. Therefore, to obtain consistent results during unipolar pulse or operating life tests, it is essential to provide a polarity identification for the test specimens. However, for initial readout purposes, this effect usually is insignificant. Maximum Clamping Voltage, V c As discussed in Section 3, the clamping voltage of a varistor is best defined in terms of the current impulse impressed on the varistor, rather than in terms of applied voltage. Two typical current impulses that may be used to define the varistor clamping voltage are the 8/20us and the 10/1000us pulses. Figure 5 shows typical varistor test waveforms for these two impulses. The clamping voltage of a given model varistor at a defined current is related by a factor of the varistor voltage. There- fore, a test of the nominal varistor voltage against specifica- tions may be sufficient to provide reasonable assurance that the maximum clamping voltage specification is also satis- fied. When it is necessary to perform the V c test, special surge generators are required. For shorter impulses than 8/20us, precautions must be observed to avoid an errone- ous "overshoot" in the measurement of the clamping volt- age. The Equipment for Varistor Electrical Testing section gives general information on surge generators; a brief description of the "overshoot" effect follows. The Harris Varistor specification sheets show the VI charac- teristic of the devices on the basis of maximum voltage appearing across the device during a current pulse of 8/20us. If current impulses of equal magnitude but faster rise are applied to the varistor, higher voltages will appear across the device. These higher voltages, described as "overshoot," are partially the result of an intrinsic increase in the varistor voltage, but mostly of the inductive effect of the unavoidable lead length. Therefore, as some applications may require 7-5 Varistor Testing current impulses of shorter rise time than the conventional 8ns, careful attention is required to recognize the contribu- tion of the voltage associated with lead inductance.' 11 The varistor voltage, because of its nonlinearity, increases only slightly as the current amplitude of the impulse increases. The voltage from the lead inductance is strictly linear and therefore becomes large as high current ampli- tudes with steep fronts are applied. For that reason, it is impractical to specify clamping voltages achieved by lead- mounted devices with current impulses having rise times shorter than 0.5us, unless circuit geometry is very accurately controlled and described. To illustrate the effect of lead length on the "overshoot," two measurement arrangements were used. As shown in Figures 6A and 6B, respectively, 0.5cm 2 and 22cm 2 of area were enclosed by the leads of the varistor and of the voltage probe. The corresponding voltage measurements are shown in the oscillograms of Figures 6C and 6D. With a slow current front of 8us, there is little difference in the voltages occurring with a small or large loop area, even with a peak current of 2.7kA. With the steep front of 0.5ns, the peak voltage recorded with the large loop is nearly twice the voltage of the small loop. (Note on Figure 6D that at the current peak, L di/dt = 0, and the two voltage readings are equal; before the peak, L di/dt is positive, and after, it is negative.) Hence, when making measurements as well as when designing a circuit for a protection scheme, it is essential to be alert to the effects of lead length (or more accurately of loop area) for connecting the varistors. This is especially important when the currents are in excess of a few amperes with rise times of less than 1us. With reasonable care in maintaining short leads, as shown in Figure 6A, it is possible to describe the "overshoot" effect as an increase in clamping voltage relative to the value observed with a 8/20(js impulse. Figure 7 shows a family of curves indicating the effect between 8us and 0.5us rise times, at current peaks ranging from 20A to 2000A. Any increase in the lead length, or area enclosed by the leads, would produce an increase in the voltage appearing across the varistor terminals - that is, the voltage applied to the protected load. VOLTAGE PROBE OUTPUT LEAD FROM TRANSIENT GENERATOR AREA = 0.5cm 2 FIGURE 6A. MINIMAL LOOP AREA VARISTOR FIGURE 6B. EXCESSIVE LOOP AREA TYPICAL "OVERSHOOT" OF LEAD-MOUNTED VARISTOR WITH STEEP CURRENT IMPULSES A = 22«m 2 _ 530 V l2.7kA FIGURE 6C. CURRENT RISE OF 8(iS FIGURE 6D. CURRENT RISE OF 0.5iiS FIGURE 6. EFFECT OF LEAD LENGTH ON "OVERSHOOT" 7-6 Varistor Testing DC Standby Current, l D This current is measured with a voltage equal to the rated continuous DC voltage, V M(DC) , applied across the varistor. The circuit of Figure 1 is applicable where current sensing resistor R2 has a value of 1000Q. The test method is to set the voltage supply, E1, to the specified value with switch S1 closed and S2 in the V position. Then S2 is placed in posi- tion I and S3 in position, l D . S1 is then opened, the test device is inserted in the test socket, and S1 is closed. The DVM reading must be converted into current. For example, if a maximum standby current of 200uA is specified, the maxi- mum acceptable DVM reading would be 0.200V. The measurement of DC standby current can be sensitive to the device behavioral phenomena of "break-in" stabilization and polarization of the VI characteristics, as described in the Nominal Varistor Voltage V N section. If the device under test has prior unipolar electrical history, polarity indicators should be observed and test values interpreted accordingly. The value of DC standby current also can be sensitive to ambient temperature. This is unlike varistor characteristics measured at currents of 1mA or greater, which are relatively insensitive to ambient temperatures. With V M(DC) around 85% of V N , Figure 8 shows the typical DC standby current of a model V1 30LA1 OA varistor in the order of 1 0uA or 20uA at room temperature. Ip increases to about 80nA at 85°C, the maximum operating temperature without derating. Capacitance Since the bulk region of a Harris Varistor acts as a dielectric, the device has a capacitance that depends directly on its area and varies inversely with its thickness. Therefore, the capacitance of a Harris Varistor is a function of its voltage and energy rat- ings. The voltage rating is determined by device thickness, and the energy rating is directly proportional to volume. Harris Varistor capacitance can be measured through use of a conventional capacitance bridge and is found to vary with frequency, as shown in Figure 9. Typically, capacitance mea- surements are made at 1MHz. Dissipation factor also is fre- quency-dependent, as shown in Figure 10. When measured with a DC bias, the capacitance and dissi- pation factor show little change until the bias approaches or exceeds the V N value. Furthermore, the capacitance change caused by an applied voltage (either DC or AC) may persist when the voltage is removed, with the capacitance gradually 40 60 80100 200 400 PEAK CURRENT (A) 600 8001000 2000 FIGURE 7. TYPICAL "OVERSHOOT" OF LEAD-MOUNTED VARISTOR WITH STEEP CURRENT IMPULSES 100 6 80 h- 2 60 O 3- it SO H « — CM Lli (- 30 S3 10" 9 '*. k I r u /o 1 \l S SPEC M EN:V1 30 .aio; i 10" 8 10" 7 10" 6 10"* 10" 4 10' 3 10" 2 VARISTOR CURRENT (A DC ) FIGURE 8. TYPICAL TEMPERATURE DEPENDENCE OF DC STANDBY CURRENT VARISTOR TYPE V130LA10A 1400 10 3 10 4 10 s 10 6 FREQUENCY (Hz) FIGURE 9. CAPACITANCE VARIATION WITH FREQUENCY 10 7 10 3 10 4 10 5 10 6 FREQUENCY (Hz) FIGURE 10. DISSIPATION FACTOR VARIATION WITH FREQUENCY 10* 7-7 Varistor Testing returning to the prebias value. Because of this phenomenon, it is important that the electrical history of a Harris Varistor be known when measuring capacitance. Miscellaneous Characteristics A number of characteristic measurements can be derived from the basic measurements already described, including the nonlinear exponent (alpha), static resistance, dynamic impedance, and voltage clamping ratio. These characteris- tics are derived characteristics in the sense that they are found by computation per the defining equations given in Sec- tion 3. The data, however, may be obtained by measurement methods similar to those already given for nominal varistor voltage and maximum clamping voltage. These miscella- neous characteristics may be useful in some cases to enable comparison of Harris Varistors with other types of non-linear devices, such as those based on silicon carbide, selenium rectifier or zener diode technologies. Varistor Rating Assurance Tests Continuous Rated RMS and DC Voltage [V^ac) and V M(DC )] These are established on the basis of operating life tests conducted at the maximum rated voltage for the product model. These tests usually are conducted at the maximum rated ambient operating temperature, or higher, so as to accelerate device aging. Some test results are given in Sec- tion 8. Unless otherwise specified, end-of-lifetime is defined as a degradation failure equivalent to a V N shift in excess of ±10% of the initial value. At this point the device is still con- tinuing to function. However, the varistor will no longer meet the original specifications. A typical operating life test circuit is shown in Figure 1 1 . If the varistor is intended principally for a DC voltage application, then the AC power source should be changed to DC. It is desirable to fuse the varistors individually so testing is not interrupted on other devices if a fuse should blow. The volt- age sources should be regulated to an accuracy of ±2% and the test chamber temperature should be regulated to within ±3°C. The chamber should contain an air circulation fan to assure a uniform temperature throughout its interior. The varistors should receive an initial readout of characteristics at room ambient temperature i.e., 25 ±3°C. They should then be removed from the chamber for subsequent readout at 168,500, and 1000 hours. A minimum of 20 minutes should be allowed before readout to ensure that the devices have cooled off to the room ambient temperature. FIGURE 11. SIMPLIFIED OPERATING LIFE TEST CIRCUIT Transient Peak Current, Energy, Pulse Rating, and Power Dissipation Ratings Special surge generator equipment is required for testing. Data on commercially available equipment is given in Table 3, and an example test circuit is described in the Equipment for Varistor Electrical Testing section. Since high energy must be stored at high voltages to perform these tests, especially on larger sizes of Harris Varistors, the equipment is necessarily expensive and must be operated using adequate safety precautions. The peak current rating, l TM of Harris Varistors is based on an 8/20us test impulse waveshape. The specifications include a maximum single value in the ratings table. A pulse rating graph defines the peak current rating for longer impulse duration as well, such as for a 10/1000us wave. A family of curves defines the rated number of impulses with a given impulse duration and peak current. Energy rating, W TM , is defined for a 10/1000us current impulse test wave. This waveshape has been chosen as being the best standard wave for tests where impulse energy, rather than peak current, is of application concern. A direct determination of energy requires that the user inte- grate over time the product of instantaneous voltage and current. Such integration is cumbersome to perform, and the integration feature is not generally available in surge genera- tion equipment. However, peak voltage and current are readily measured with available equipment. Therefore, the energy rating can be tested indirectly by applying the rated peak impulse cur- rent of a 10/1000us waveshape to the test specimen. Then, the energy dissipated in the varistor can be estimated from the known pulse waveshape. For a 10/1000us waveshape the approximate energy is given by the expression E = 1.4V C It. See Section 4 for a discussion of energy dissi- pation for various waveshapes. For example, a model V130LA10A varistor has a single pulse rating for a 10/1000us impulse waveshape of about 75A peak, and a maximum clamping voltage at 75A of about 360V. Thus, the computation of estimated energy dissipation is 38J. The transient power dissipation rating, P-r^M' ' s defined as the maximum average power of test impulses occurring at a specified periodic rate. It is computed as the estimated energy dissipation divided by the test pulse period. Therefore, varistors can be tested against this rating by applying two or more impulses at rated current with a specified period between pulses. For example, a model V1 30LA1 OA varistor has a pulse rating of two 1 0/1 OOOus test impulses with a peak current of about 65A. The estimated energy dissipation per pulse computed as per the preceding example is about 30J. If a period of 50s is allowed after the first test pulse, the estimated average power dissipation can be computed as about 0.6W, which is the specification rating. It should be noted that Harris Varistors are not rated for continuous operation with high-level transients applied. The transient power dissipation rating is based on a finite number of pulses, and the pulse rating of the varistor must be observed. See Figure 12. 7-8 Varistor Testing 1 1 10C mV : : 1 : 1n IS -h-h- +H+ +H+ 1ms/DIV 10/1000ns WAVEFORM FIGURE 12. SURGE TEST WAVEFORMS Table 1 outlines a suggested program of testing to verify varistor transient and pulse ratings with a minimum of expensive, time-consuming testing. New specimens should be used for each test level and failure judged according to the specification criteria. TABLE 1. TESTING OF TRANSIENT CURRENT, ENERGY, PULSE RATING, AND POWER DISSIPATION RATINGS TEST PARAMETER NO. PULSES AT RATED CURRENT (ALTERNATING POLARITY) TEST WAVE- SHAPE (MS) MINIMUM PULSE PERIOD (s) Maximum Peak Current 1 (same polarity as readout) 8/20 NA Pulse/Energy Rating, Power Dissipation 2 10/1000 50 Pulse Rating 10 8/20 25 Pulse Rating 100 8/20 12 Continuous Power Dissipation Since Harris Varistors are used primarily for transient sup- pression purposes, their power dissipation rating has been defined and tested under transient impulse conditions. If the devices are to be applied as threshold sensors or coarse voltage regulators in low power circuits, then a dissipation test under continuous power is more appropriate. This con- tinuous power test will aid the user in determining if the device is suitable for his specific application. A circuit for continuous power dissipation testing is shown in Figure 13. The DC power supply voltage should be set to a value of approximately twice the nominal varistor voltage of the product model under test. In that case, nearly constant power dissipation is maintained in the varistor. Since the cir- cuit transfers nearly equal power to the series resistor and varistor-under-test, the series resistor value is simply chosen to achieve the test design value of power dissipation. In Figure 13 a nearly constant power dissipation of about 0.6W is obtained. FIGURE 13. CONSTANT POWER LIFE TEST CIRCUIT Mechanical and Environmental Testing of Varistors Introduction Many tests have been devised to check the reliability of electronic components when subjected to mechanical and environmental stresses. Although individual equipment makers may specify their own tests on component purchase documents, these tests are often based on an equivalent MIL-STD specification. Therefore, it is convenient to summarize these tests in MIL-STD terms. Since the ratings of Harris Varistors may vary with product series and model, the test conditions and limits should be as specified on the applicable detail specification. Harris Varistors are available in a high reliability series. This series incorporated most standard mechanical and environ- mental tests, including 100% pre-screening and 100% pro- cess conditioning. Details are provided in Section 13. UL Recognition Tests The standards of Underwriters Laboratories, Inc. (UL) under which applicable Harris Varistors have been tested and rec- ognized are: • UL-1449 Transient Voltage Surge Suppressors, File E75961 • UL-1414 Across the Line Components, File E56529 • UL-497B Protectors for Data Communications, File E35010 The tests were designed by UL and included discharge (withstand of charged capacitor dump), expulsion (of com- plete materials), life, extended life, and flammability (UL94V0) tests. Equipment for Varistor Electrical Testing Introduction Most tests of Harris Varistors can be performed with rela- tively simple circuits and inexpensive equipment on the labo- ratory bench. However, large users with versatile automatic test systems available may find it more economical to pro- gram these systems for the low-current varistor tests. As noted previously, medium or high-current impulse testing will require specialized test equipment. Table 2 is a partial listing of available test equipment and systems that can be used for varistor testing. It is intended as a guide only to illustrate the generic type of equipment offered commercially. 7-9 Varistor Testing Impulse Generators A convenient method of generating current or voltage surges consists of slowly storing energy in a capacitor network and abruptly discharging it into the test varistor. Possible energy storage elements that can be used for this purpose include lines (lumped or distributed) and simple capacitors, depend- ing on the waveshape desired for the test. Figure 14 shows a simplified schematic for the basic elements of an impulse generator. OSCILLOSCOPE FIGURE 14. SIMPLIFIED CIRCUIT OF SURGE IMPULSE GENERATOR The circuit is representative of the type used to generate exponentially decaying waves. The voltage supply, E1, is used to charge the energy storage capacitor, C, to the specified open-circuit voltage when switch S1 is closed. When switch S2 (an ignition or a triggered gap) is closed, the capacitor, C, discharges through the waveshaping elements of the circuit into the suppressor device under test. With capacitances in the order of 1u.F to 10uF and charging voltages of 10kV to 20kV, the typical 8/20u.s or 10/1 000ns impulses can be obtained by suitable adjustment to the waveshaping components L, R1, and R2, according to conventional surge generator design. I 2 - 3 ' 4 - 5 ' Measurement Instrumentation Transient measurements include two aspects of varistor application: (1) detection of transients to determine the need for protection, and (2) laboratory measurements to evaluate varistor performance. Transient detection can be limited to recording the occurrence of transient overvoltages in a par- ticular system or involve comprehensive measurements of all the parameters which can be identified. Simple detection can be performed with peak-indicating or peak-recording instruments, either commercial or custom-made. Table 3 gives a partial listing of such instruments. Laboratory instruments and field detection with comprehen- sive instrumentation can involve substantial investment, pri- marily associated with oscilloscopes, cameras, and calibrated sensors. A detailed discussion of these systems is beyond the scope of this manual; rather, the major oscilloscope manufac- turers should be consulted, as well as the available literature. Test Waves and Standards The varistor test procedures described in this section have been established to ensure conformity with applicable standards,' 6 ' as well as to reflect the electromagnetic environment of actual circuits' 7 ' which need transient protection. Section 1 presented an overview of the transient environment; some additional background is presented in this section concerning generally accepted assumptions about this environment. Test Waves A number of test waves have been proposed, to be applied to various electronic "black boxes," in order to demonstrate capability of survival or unimpeded performance in the envi- ronment. Table 4 is a partial listing of these test waves pre- sented to illustrate the variety of proposals rather than to be an exhaustive listing. TABLE 2. AVAILABLE EQUIPMENT FOR VARISTOR TESTING t TYPE AND MANUFACTURER MODEL FEATURES Storage Curve Tracer Tektronix, Inc. P.O. Box 500 Beaverton, OR 97077 503-627-71 1 1 577/177 (Also can use 576) AC and DC tests up to 1600V peak, with safety interlock, storage display mode. Auto Capacitance Bridge Genrad Inc. 300 Baker Ave. Concord, MA 01742 617-369-4400 1687 1 MHz test frequency, 3 measurements/sec, 0.01 % accu- racy, digital display, programmable control, IEEE testing. Varistor Test System Mastech, Inc. 478 E. Brighton Ave. Syracuse, NY 13210 315-478-3133 222F, 342 0V-2000V, up to 10mA DC , 100mA pulse, digital readout, front panel programming. 0kV-100kV at 10A. Front panel programming. IEEE Standard 4888. Semiconductor Test Systems Teradyne, Inc. 183 Essex St. Boston, MA 02111 617-482-2700 T57 or Z27 0V-1200V, up to 10mA, computer operated, line printer output, multiple test stations, data analysis software, tape cartridge. 7-10 Varistor Testing TABLE 2. AVAILABLE EQUIPMENT FOR VARISTOR TESTING t (Continued) Type AMn MAN1 IFACTI IRFR MODEL FEATURES Pulse Generator Cober Electronics, Inc. 102 Hamilton Ave. Stamford, CT 06904 Velonex 560 Robert Ave. Santa Clara, CA 95050 408-727-7370 605P 360,587,510.515 2.2kV, 20kW peak power, pulses 0.3ps - 10ms, variable PRF or can amplify external input. 2.5kV, 10A, pulses, up to 300(is wide, variable PRF, vari- able rise-fall available, plug-ins for higher peak I. Surge Generator Systems KeyTek Instrument Corp. 260 Fordham Rd. Wilmington, MA 617-272-5170 System 1000, including Models 424, 71 1 and 587 6kV, up to 10kA, further expandable, selectable wave- shapes (8/20, 10/1000, etc.), measures and displays peak V-l across test device. Peak biased differential high voltage probe. IEEE testing. Joslyn Corp P.O. Box 817 Santa Barbara Research Park 6868 Cortona Drive Goleta, CA 93116 805-968-3551 4020-01 4010-01 • 5 pin telephone module tester • Tests Gas Tube and Solid State modules • Battery operation • Test set for surge protection devices • Tests breakdown at 1 mA and clamping voltage • Tests MOVs, Zener, etc. t Inclusion of any manufacturer in this listing does not constitute an endorsement nor does exclusion imply any judgment upon same. TABLE 3. AVAILABLE EQUIPMENT FOR VARISTOR TESTING f TYPE AND MANUFACTURER MODEL FEATURES Storage Oscilloscopes Tektronix P.O. Box 500 Beaverton, OR 97077 503-627-7111 466, 7834 100MHz, 3000div/ps speed, portable Multimode storage, 400MHz, 5500div/us Peak Recording Instruments Micro-Instrument P.O. Box 1565 2250 Micro Place Escondido, CA 92025 619-746-2010 Bermar P.O. Box 12844 Research Triangle Park North Carolina 27709 919-489-4316 Dranetz Technologies 1000 New Durham Rd. Edison, NJ 08818 201-287-3680 Industrionics 54 Holliston St. Medway, MA 02053 617-533-6736 Trott Electronics Inc. 9020 Wehrle Dr. Clarence, NY 14031 716-634-8500 Memory Voltmeter Model 5203 Memory Voltmeter MVM-108 Model 606, 626 Zap Trap TR745A 20MHz, records, displays voltage levels up to 2kV Displays peak voltage, >0.5us pulses up to 8kV Prints out peak voltages, >0.5us duration pulse Measures peak voltages, >2\is duratior. Detects 0.3ns pulses, up to 3000V + Inclusion of any manufacturer in this listing does not constitute an endorsement nor does exclusion imply any judgment upon same. Dl 7-11 Varistor Testing TABLE 4. PARTIAL LISTING OF EXISTING OR PROPOSED TEST WAVES ORIGIN DESCRIPTION TYPICAL APPLICATION WAVESHAPES AMPLITUDE ANSI, IEC • 1 .2/50us • 8/20(j s Specified voltage Specified current Power apparatus IEEE Std. 472 Guide for Surge Withstand Capability (SWC) • 1.25MH repetitive at 60Hz • 6us decay to 50% • 1 50Q source impedance 2.5kV Peak Low-voltage AC circuits and control lines in substation equipment. ANSI/IEEE Std. C62.41-1991 Recommended Practices on Surge Voltage in Low Voltage AC Power Circuits • 0.5ns- 100kHz • 1 .2/50ps voltage • 8/20us current Dependent on location Low-voltage AC circuits and signal lines. Ground Fault Interrupters • 0.5ns rise • 100kHz ring • 2nd peak > 60% first • 50Q source impedance 3kV and 6kV High impedance circuit of ground fault interrupters. ANSI/IEEE C62.31-1982 Test Specifications for Gas Tube Surge Protective Devices Three requirements: • 10/1000|as current • 8/20us current • Linear voltage ramp of 100, 500, 5000, 10.000V/us until sparkover 50 to 500A 5 to 20kA Telephone protectors roc Docket i yb^o • Metallic - 10/560ns - 100A short-circuit current • Longitudinal - 10/1 60ns - 200A short-circuit current 800V PEAK 1500V PEAK Communications equipment FCC Section 68.302 Title 47, Telecommunications • 2/1 Ops - 1000A short-circuit capability 2500V PEAK Line-powered communication equip- ment Rural Electrification Administration Spec. PE-60 • 10/1000U.S voltage • 1 0OV/us rise 30" of Protector level Telephone electronics Nuclear Electromagnetic Pulse (NEMP) • Rectangular pulse 3ns to 10|is • Damped sinewave 10 1 Hz to 10 3 Hz 0.1 A to 1000A 1.0A to 100A Evaluation of components NASA Space Shuttle • Damped sinewave 125kHz • Unidirectional - 2/100us - 300/600us E 0C " 50V Isc - 10A E c - 50V Isc " 10A E c " °-5V l S c " 5A Space shuttle electronics MIL-STD-704 • Envelope specified, max. duration 50ps 600V PEAK Military aircraft power ANSI/IEEE Std. C62.33-1982 Test Specification for Varistor Surge Protective Devices • 8/20U.S current • 10/1 000ns current From manufacturer's specifications Suppressors for low voltage AC circuits, electronic equipment IEEE Std. P465.4/FD Test Specifications for Avalanche Junction Semiconductor Surge Protective Devices • 8/20U.S current • 10/1 000ns current From manufacturer's specifications Suppressors for electronic equipment UL1449 Transient Voltage Surge Suppressors • 1 .2/50U.S voltage • 8.20us current 6kV 125A to 3kA depen- dent on location Suppressors for low voltage AC circuits 7-12 Varistor Testing A proposal also has been made to promote a transient con- trol level concept 17 ' whereby a few selected test waves could be chosen by common agreement between users and man- ufacturers. The intent being that standard test waves would establish certain performance criteria for electronic circuits, without resorting to a multiplicity of test waves, each attempting to simulate a particular environment. Source Impedance The effective impedance of the circuit which introduces the transient is an extremely important parameter in designing a protective scheme. Impedance determines the energy and current-handling requirements of the protective device. Historically, the approach to transient withstand capability was to apply a voltage wave to a device and to ascertain that no breakdown occurred. Typically, the device offered high impedance to the impulse, so that no significant current would flow (unless breakdown occurred), and the source impedance was unimportant. But if a transient suppressor is applied, especially a suppressor of the energy-absorbing type, the transient energy is then shared by the suppressor and the rest of the circuit, which can be described as the "source". As in the case of waveshapes, various proposals have been made for standardizing source impedances. The following list summarizes the various proposals intended for AC power lines: 1 . The Surge Withstand Capability (SWC) standard speci- fied a 1500 source. 2. The Ground Fault (UL-GFCI) standard is 50£J source. 181 3. The Transient Control Level (TCL) proposals of Martzloff et al' 7 ' include a 50£i resistor in parallel with a 50|iH inductor. 4. The installation category concept of ANSI/IEEE Standard C62.41-1980 implies a range of impedances from 1Q to 50S2 as the location goes from outside to inside. 5. The FCC regulation for line-connected telecommunication equipment implies a 2.5£2 source impedance. 191 However, the requirement of the FCC is aimed at ensuring a permanent "burning" of a dielectric puncture and does not necessarily imply that the actual source impedance in the real circuits is 2.5H. 6. Reported measurements' 101 indicate the preponderance of the inductance in branch circuits. Typical values are uH per meter of conductors. 7. There is no agreement among the above proposals on a specific source impedance. Examining the numbers clos- er, one can observe that there is a variance between 2.5£2 to about 50Q. Going back to ANSI/IEEE Standard C62.41 -1 980 by using the OCV (open circuit voltage) and SCI (short circuit current) for the different location catego- ries, one can calculate a source impedance. Any practical power circuit will always have some finite impedance due to the resistance and inductance of the power line and distribution transformer. Figure 15 shows representations of the surge source impedance implied in the environment description of ANSI/IEEE C62.41-1980. Category A Ring Wave 6kV/200A = 30Q Category B Ring Wave 6kW500A= 12U Category B Impulse 6kV/3kA = SQ Category C Impulse 10kV/10kA = 1fi NOTE: IEEE categories A, B and C are defined in Section 9. FIGURE 15. SOURCE IMPEDANCE AT DIFFERENT LOCATION CATEGORIES IN LOW VOLTAGE AC SYSTEMS (UP TO 1000V) The impedance of industrial or commercial systems gener- ally supplied by underground entrances, or a separate sub- station of relatively large kVA rating, tends to be low, and the injection of any lightning transients occurs at a remote point. This results in lower transient peaks than those that can be expected in residential circuits, but the energy involved may be, in fact, greater. Therefore, transient suppressors intended for industrial use should have greater energy-han- dling capability than the suppressors recommended for line- cord-powered appliances. Clearly, the industry standards have not been able to agree on a single value of the source impedance, for several reasons. When a transient suppressor is being selected for a particular application, there is a need for engineering judgment based on a knowledge of the function, and the capability of the device. 7-13 Varistor Testing References [1] Fisher, F.A., "Overshoot - A Lead Effect in Varistor Char- acteristics," Report 78CRD, General Electric, Schenac- tady, N.Y., 1978. [2] Heller, B. and A. Veverka, "Surge Phenomena in Electri- cal Machine", ILIFFE Books Ltd., London, 1968. [3] Greenwood, Allen, "Electrical Transients in Power Sys- tems", Wiley Interscience, New York, 1971 . [4] Craggs, J.D. and J.M. Meek, "High Voltage Laboratory Techniques", Buttersworth Scientific Publications, Lon- don, 1954. [5] Martzloff, F.D., "Transient Control Level Test Genera- tors", Report 77CRD241, General Electric, Schenectady, N.Y., 1977. [6] "Test Specifications for Varistor Surge-Protective Devices", ANSI/IEEE Std. C62.33, 1982. [7] Martzloff, F.D., and F.A. Fisher, "Transient Control Level Philosophy and Implementation - The Reasoning Behind the Philosophy," 77CH1224-5EMC, "Proceed- ings of the 2nd Symposium on EMC", Montreux, June 1977. [8] "Standard for Safety: Ground Fault Circuit Interrupters," UL943, Underwriters Laboratories, May 12,1976. [9] "Longitudinal Voltage Surge Test #3," Code of Federal Regulations, Section 68.302(e), Title 47, Telecommuni- cations. [10] F.D. Martzloff, "The Propagation and Attenuation of Surge Voltages and Surge Currents in Low-Voltage AC Circuits," IEEE Transactions on Power Apparatus and Systems, PAS-102, pp. 1163-1170, May 1983. 7-14 TVS SURGECTOR PRODUCTS PAGE SURGECTOR PRODUCT SELECTION GUIDE 8-2 SURGECTOR DATA SHEETS SGT03U13, SGT06U13, Unidirectional Transient Surge Suppressors (SURGECTOR™) 8-3 SGT23U13 SGT10S10, SGT27S10 Gate Controlled Unidirectional Transient Surge Suppressors 8-6 SGT21B13.SGT21B13A, Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-10 SGT22B1 3, SGT22B13A, SGT23B13.SGT23B13A, SGT27B13.SGT27B13A, SGT27B13B SGT27B27.SGT27B27A, Bidirectional Transient Surge Suppressors (SURGECTOR™) 8-14 SGT27B27B SGT27S23 Gate Controlled Unidirectional Transient Surge Suppressor (SURGECTOR™) 8-18 5 {2 go w - 8-1 Surgector Product Selection Guide PART NUMBER FUNCTION V Z MIN (V) V B0 MAX (100V/ps) •tsm (1 x 2ns) 'tsm (10x 1000ns) Ih (mA) PACKAGE STYLE SGT10S10 (Note 1) VAR Clamp 100 Note 1 300 100 > 100 A SGT27S10 (Notel) VAR Clamp 270 Note 1 300 100 > 100 A SGT27S23 (Note 1) VAR Clamp 270 Note 1 300 100 >230 A SGT03U13 Uni-Directional 30 <50 300 100 > 130 B SGT06U13 Uni-Dlrectional 60 <85 300 100 > 130 B SGT23U13 Uni-Directional 230 <275 300 100 > 130 B SGT21B13 Bi-Directional 210 270 300 100 >130 B SGT21B13A Bi-Directional 210 290 300 100 >130 B SGT22B13 Bi-Directional 220 280 300 100 >130 B SGT22B13A Bi-Directional 220 290 300 100 >130 B SGT23B13 Bi-Directional 230 290 300 100 >130 B SGT23B13A Bi-Directional 230 315 300 100 >130 B SGT27B13 Bi-Directional 270 345 300 100 >130 B SGT27B13A Bi-Directional 270 360 300 100 >130 B SGT27B13B Bi-Directional 270 375 300 100 >130 B SGT27B27 Bi-Directional 270 345 600 200 >270 B SGT27B27A Bi-Directional 270 360 600 200 >270 B SGT27B27B Bi-Directional 270 375 600 200 >270 B NOTES: 1 . Dependent on trigger circuit. 2. All surgectors supplied in modified JEDEC TO-202 Package Package Style A = 3 lead version Package Style B = 2 lead version 3. All devices UL recognized to 497B - File Number E135010. |SGT|03|U |i3l L_ Holding current in milliamps divided by 10 Type of SURGECTOR: U = Unidirectional B = Bidirectional S = SCR _ Off-State Voltage Rating divided by 10 ' — SURGECTOR Nomenclature, Packages, and Shipping The SURGECTOR type numbers are easy to interpret. The first three characters - the letter "SGT" - stand for SURGECTOR. Next comes two digits, which represent the maximum off-state voltage divided by 10. Following the voltage is a letter indicating either SCR (S), Unidirectional (U), or Bidirectional (B). The next two digits indicate holding current in milliamps divided by 10. All versions of the SURGECTOR are housed in a modified TO-202 versatab plastic package. This is a single-in-line package, meaning that all leads come out of the same end and are parallel to one another. The advantage of single-in-line packaging is that it makes the SURGECTOR easy to insert into a circuit board or socket by automated methods. SURGECTOR devices are shipped to the customer either in bulk or on plastic "sticks" designed for automated machinery handling. The sticks are rectangular tubes that hold 50 SURGECTOR devices each. Surgector Packages MODIFIED TO-202 PACKAGE STYLE PACKAGE A PACKAGE B 8-2 SEMICONDUCTOR March 1995 SGT03U13, SGT06U13, SGT23U13 Unidirectional Transient Surge Suppressors (SURGECTOR™) ANODE CATHODE MODIFIED TO-202 Features • Clamping Voltages: 33V, 60V, or 230V • Peak Transient Surge Current: 300A • Minimum Holding Current: 130mA • Subnanosecond Clamping Action • Low On-State Voltage • UL Recognized File #E135010 to STD 497B Applications • Telecommunications Equipment • Data and Communication Links • Computer Modems • Alarm Systems Description These SURGECTOR devices are designed to protect tele- communication equipment, data links, alarm systems, power supplies and other sensitive electrical circuits from damage by switching transients, lightning strikes, load changes, com- mutation spikes and line crosses. These SURGECTOR devices are monolithic compound structures consisting of a thyristor whose gate region con- tains a special diffused section which acts as a zener diode. This zener diode section permits anode voltage turn-on of the structure. Initial clamping by the zener diode section and fast turn-on by the thyristor, provide excellent voltage limiting even on very fast rise time transients. The thyristor also fea- tures very high holding current allowing the SURGECTOR to recover to its high impedance off state after a transient. The SURGECTOR device's normal off-state condition in the for- ward blocking mode is a high impedance, low leakage state that prevents loading of the line. Absolute Maximum Ratings t c = +25°c Continuous Off State Voltage: Vrm Transient Peak Surge Current: I t sm 1u.s x 2ns (Note 1) 8ns x 20ns 1 0ns x 560ns 10ns x 1000ns One Half Cycle 50Hz to 60Hz (Note 2) One Second 50Hz to 60Hz, Halfwave Operating Temperature (T A ) Storage Temperature Range (T STG ) NOTES: 1 . Unit designed not to fail open below: 450A 2. One every 30s maximum. T03U13 SGT06U13 SGT23U13 UNITS 30 58 225 V 1 1 1 V 300 300 300 A 200 200 200 A 125 125 125 A 100 100 100 A 60 60 60 A 30 30 30 A -40°C to +85°C °C -40°Cto+150°C °C Equivalent Schematic Symbols Z SURGECTOR™ is a trademark of Harris Semiconductor. CAUTION: These devices are sensitive to Copyright © Harris Corporation 1 995 Users should follow proper I.e. Handling Procedures. 8-3 File Number 1692.1 Specifications SGT03U13, SGT06U13, SGT23U13 Electrical Specifications At Case Temperature, T c = +25°C, Unless Otherwise Specified PARAMETER SYMBOL TEST CONDITIONS SGT10S10 UNITS MIN TYP MAX Off-State Current Maximum Rated V DM T - j.9£; P 1 a — ^ T A = +85°C - - 50 10 n A ma Reverse Current 'rm Vrm=1V T A = +25°C - - 1 10 mA mA Clamping Voltage SGT03U13 SGT06U13 SGT23U13 Vz 1^ = 1 UU|iA 33 60 230 V V V Breakover Voltage SGT03U13 SGT06U13 SGT23U13 v B o dv/dt=100V/us 50 85 275 V V V Holding Current Ih 130 mA On-State Voltage v T l T = 1 0A 2 V Main Terminal Capacitance Co 90 pF Performance Curves 275 250 225 200 175 150 125 100 75 50 25 . SGT23U13 SC T06 J13 n I — r— i I FIGURE 1. TYPICAL VOLT-AMPERE CHARACTERISTICS -40 -30 -20 -10 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE ("C) FIGURE 2. TYPICAL CLAMPING VOLTAGE vs TEMPERATURE 1.5 f 1.4 £ 1.3 ui E § 1.2 o O 1.1 5 x Q 0.9 ui N ^ 0.8 1 O 0.7 z 0.6 1 1 1 1 1 ■ r v -40 -30 -20 -10 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (°C) FIGURE 3. TYPICAL HOLDING CURRENT vs TEMPERATURE 275 250 > 225 UJ (3 200 175 o > a: 150 UI > O 125 < UI 100 75 50 25 10 100 1,000 RATE OF RISE OF VOLTAGE (V/us) FIGURE 4. TYPICAL V B0 vs dv/dt 10,000 8-4 SGT03U13, SGT06U13, SGT23U13 Terms and Symbols V DM (Maximum Off-State Voltage) - Maximum off-state volt- age (DC or peak) which may be applied continuously. V RM (Maximum Reverse Voltage) - Maximum reverse- block- ing voltage (DC or peak) which may be applied. Ijsm (Maximum Peak Surge Current) - Maximum nonrepeti- tive current which may be allowed to flow for the time state. T A (Ambient Operating Temperature) - Ambient temperature range permitted during operation in a circuit. T STG (Storage Temperature) - Temperature range permitted during storage. I DM (Off-State Current) - Maximum value of off-state current that results from the application of the maximum off-state voltage (V DM ). I RM (Reverse Current) - Maximum value of reverse current that results from the application of the maximum reverse voltage (V RM ). V z (Clamping Voltage) - off-state voltage at a specified cur- rent. V B0 (Breakdown Voltage) - voltage at which the device switches from the off-state to the on-state. I H (Holding Current) - Minimum on-state current that will hold the device in the on-state after it has been latched on. V T (On-State Voltage) - Voltage across the main terminals for a specified on-state current. C (Main Terminal Capacitance) - Capacitance between the main terminals at a specified off-state voltage. Packaging ACTIVE ELEMENT - TO-202 Modified 2 LEAD JEDEC STYLE TO-202 SHORT TAB PLASTIC PACKAGE SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.130 0.150 3.31 3.81 b 0.024 0.028 0.61 0.71 2, 3 bi 0.045 0.055 1.15 1.39 1. 2, 3 b 2 0.270 0.280 6.86 7.11 c 0.018 0.022 0.46 0.55 1. 2, 3 D 0.320 0.340 8.13 8.63 E 0.340 0.360 8.64 9.14 e ( 0.200 BSC 5.08 BSC 4 H, 0.080 0.100 2.04 2.54 Ji 0.039 0.049 1.00 1.24 5 L 0.410 0.440 10.42 11.17 t-1 0.080 0.100 2.04 2.54 1 NOTES: 1. Lead dimension and finish uncontrolled in L,. 2. Lead dimension (without solder). 3. Add typically 0.002 inches (0.05mm) for solder coating. 4. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 5. Position of lead to be measured 0. 1 00 inches (2.54mm) from bottom of dimension D. 6. Controlling dimension: Inch. 7. Revision 3 dated 10-94. 8-5 33 SEMICONDUCTOR SGT10S10, SGT27S10 March 1995 Gate Controlled Unidirectional Transient Surge Suppressors Features • Blocking Voltage 100V and 270V Applications • Telecommunications Equipment CATHODE _ ANODE ANODE Peak Transient Surge Current • Data and Voice Lines 300A MODIFIED TO-202 • Minimum Holding Current 100mA • Subnanosecond Clamping Action • Low On-State Voltage • UL Recognized File # E1 35010 to STD 497B • Computer Modems • Alarm Systems Description SURGECTOR transient surge protectors are designed to protect telecommunication equipment, data links, alarm sys- tems, power supplies, and other sensitive electrical circuits from damage that could be caused by switching transients, lightning strikes, load changes, commutation spikes, and line crosses. These devices are fast turn-on, high holding current thyris- tors. When coupled with a user supplied voltage level detec- tor, they provide excellent voltage limiting even on very fast rise time transients. The high holding current allows this SURGECTOR to return to its high impedance off state after a transient. The SURGECTOR device's normal off-state condition in the forward blocking mode is a high impedance, low leakage state that prevents loading of the line. Absolute Maximum Ratings t c = +25°c Continuous Off State Voltage: Vdm Vrm Transient Peak Surge Current: I TSM 1(is x 2u.s (Note 1) 8|iS x 20ns 10|isx560ms 10us x 1000us One Half Cycle, 1 every 30s 50Hz to 60Hz One Second. Halfwave 50Hz to 60Hz Operating Temperature (T A ) Storage Temperature Range (T STG ) NOTE: 1 . Unit designed not to fail open below 450A. SGT10S10 SGT27S10 UNITS 100 270 V 1 1 V 300 300 A 200 200 A 125 125 A 100 100 A 60 60 A 30 30 A -40°C to +85°C °C -40°Cto+150°C °C Equivalent Schematic Symbols + ? A r z z SURGECTOR is a trademark ol Harris Semiconductor. CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.e. Handling Procedures. Copyright © Harris Corporation 1 995 fl fi File Number 1691. Specifications SGT10S10, SGT27S10 Electrical Specifications At Case Temperature. T c = +25°C, Unless Otherwise Specified TCCT 1 to 1 CONDITIONS SGT10S10 SGT27S10 PARAMETER SYMBOL MIN TYP MAX MIN TYP MAX UNITS Off-State Current 'dm V DM = 100V T^ 4 +25°C T A = +85°C _ 50 10 - - nA HA 'dm Vdm = 270V T A = +25°C T A - +85°C - - - - - 100 50 nA uA Off-State Current !rm Vrm = 1V T A = +25°C T A = +85°C _ 1 10 - - 1 10 mA mA Breakover Voltage Vbo dv/dt= 100V/HS (Note 1) 100 285 V Holding Current M 100 100 mA On-State Voltage v T l T = 10A 2 2 V Gate-Trigger Current Igt 150 150 mA Main Terminal Capacitance Co v DM = ov V DM = 50Vat1MHz 90 50 PF PF NOTE: 1. External zener diode from anode to gate: 60V (SGT10S10); 270V (SGT27S10). Performance Curves I r. v 80 FIGURE 1. TYPICAL VOL' ; Vdm CHARACTERISTICS _ 1.4 < E i u m I 1.2 a o U ' ■ 1 o 3 S 0.9 a E 0.7 E i ... 1 1 1 V- - 30V -40 -30 -20 -10 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (°C) FIGURE 2. NORMALIZED GATE-TRIGGER CURRENT vs TEMPERATURE 8-7 SGT10S10, SGT27S10 Performance Curves (Continued) < 1.4 E 6 1.3 jS I £ 1.2 3 O 1.0 0.9 0.8 s O 0.7 0.6 Q § 1 1 1 1 2A -40 -30 -20 -10 10 20 30 40 SO 60 70 80 90 AMBIENT TEMPERATURE (°C) 3. NORMALIZED HOLDING CURRENT vs TEMPERATURE EXTERNAL ZENER DIODE FROM ANODE TO GATE 60V(SGT10S10); 270V (SGT27S10) 100 1,000 RATE OF RISE OF VOLTAGE (V/|iS) FIGURE 4. NORMALIZED V B0 vs dv/dt Terms and Symbols V DM (Maximum Off-State Voltage) - Maximum off-state volt- age (DC or peak) which may be applied continuously. V RM (Maximum Reverse Voltage) - Maximum reverse-block- ing voltage (DC or peak) which may be applied. Ijsm (Maximum Peak Surge Current) - Maximum nonrepeti- tive current which may be allowed to flow for the time state. T A (Ambient Operating Temperature) - Ambient temperature range permitted during operation in a circuit. T STG (Storage Temperature) - Temperature range permitted during storage. I dm (Off-State Current) - Maximum value of off-state current that results from the application of the maximum off-state voltage (V DM ). I RM (Reverse Current) - Maximum value of reverse current that results from the application of the maximum reverse voltage (V RM ). I H (Holding Current) - Minimum on-state current that will hold the device in the on-state after it has been latched on. V T (On-State Voltage) - Voltage across the main terminals for a specified on-state current. Iqx (Gate-Trigger Current) - Minimum gate current which will cause the device to switch from the off-state to the on-state. C Q (Main Terminal Capacitance) - Capacitance between the main terminals at a specified off-state voltage. 8-8 SGT10S10, SGT27S10 Packaging ACTIVE ELEMENT b 2 ^7 TO-202 Modified 3 LEAD JEDEC STYLE TO-202 SHORT TAB PLASTIC PACKAGE J SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.130 0.150 3.31 3.81 b 0.024 0.028 0.61 0.71 2, 3 bi 0.045 0.055 1.15 1.39 1, 2, 3 b 2 0.270 0.280 6.86 7.11 c 0.018 0.022 0.46 0.55 1 , 2, 3 D 0.320 0.340 8.13 8.63 E 0.340 0.360 8.64 9.14 e 0.100 TYP 2.54 TYP 4 ei 0.200 BSC 5.08 BSC 4 H, 0.080 0.100 2.04 2.54 J, 0.039 0.049 1.00 1.24 5 L 0.410 0.440 10.42 11.17 Li 0.080 0.100 2.04 2.54 1 NOTES: 1. Lead dimension and finish uncontrolled in L,. 2. Lead dimension (without solder). 3. Add typically 0.002 inches (0.05mm) for solder coating. 4. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 5. Position of lead to be measured 0.1 00 inches (2.54mm) from bottom of dimension D. 6. Controlling dimension: Inch. 7. Revision 3 dated 10-94. SI SEMICONDUCTOR March 1995 SGT21B13, SGT21B13A, SGT22B13, SGT22B13A, SGT23B13, SGT23B13A, SGT27B13, SGT27B13A, SGT27B13B Bidirectional Transient Surge Suppressors (SURGECTOR™) MODIFIED TO-202 Features • Clamping Voltage 210V, 220V, 230V and 270V • Peak Transient Surge Current . . 300A • Minimum Holding Current . . . 130mA • Continuous Protection • Low On-State Voltage • UL Recognized File #E1 35010 to STD 497B Applications • Data and Communication Links • Computer Modems • Alarm Systems Description These SURGECTOR devices are designed to protect telecom- munication equipment, data links, alarm systems, power sup- plies and other sensitive electrical circuits from damage by switching transients, lightning strikes, load changes, commuta- tion spikes and line crosses. Bidirectional SURGECTOR devices are constructed using two monolithic compound chips each consisting of a thyristor whose gate region contains a special diffused section which acts as a zener diode. This chips are connected in anti parallel, providing bidirectional protection. This zener diode section permits anode voltage turn on of the structure. Initial clamping by the zener diode section, and fast turn on by the thyristor, provide excellent voltage limiting even on very fast rise time transients. The thyristor also features very high holding current, which allows the SURGECTOR to recover to its high impedance off state after a transient. All these devices are supplied in a 2 lead, modified TO-202 VERSATAB package. Absolute Maximum Ratings T c = +2S°c Continuous Off State Voltage: Vdm Vrm Transient Peak Surge Current I TSM 1(is x 2ms (Note 1) 8ns x 20ms 10ms x 560ms 10ms x 1000ms One Half Cycle 50Hz to 60Hz (Note 2) One Second 50Hz to 60Hz, Halfwave Operating Temperature (T A ) Storage Temperature Range (T STG ) NOTES: 1 . Unit designed not to fail open below: 450A. 2. One every 30s maximum. Equivalent Schematic Symbols MT2 SGT27B13 SGT21B13 SGT22B13 SGT23B13 SGT27B13A SGT21 B13A SGT22B13A SGT23B13A SGT27B13B UNITS 185 190 200 235 V 185 190 200 235 V 300 300 300 300 A 200 200 200 200 A 125 125 125 125 A 100 100 100 100 A 60 60 60 60 A 30 30 30 30 A -40°C to +85°C -40°C to +85°C °C -40°C to +150°C -40°Cto+150°C °C . MT2 MT1 MT2 zz SURGECTOR™ is a trademark ol Harris Semiconductor CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.C. Handling Procedures. Copyright © Harris Corporation 1 995 „ 1 _ File Number 1895.3 Specifications SGT2XB13, SGT2XB13A, SGT27B13B Electrical Specifications At Case Temperature, T c = +25°C, Unless Otherwise Specified PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Oft-State Current 'dm. Irm Maximum Rated V DM , V RM T A = +25°C T A = +85°C - - - - 200 100 nA M A Clamping Voltage Vz l z < 200mA SGT21B13 210 - 250 V SGT21B13A 210 270 V SGT22B13 220 260 V SGT22B13A 220 - 270 V SGT23B13 230 - 270 V SGT23B13A 230 - 295 V SGT27B13 270 - 325 V SGT27B13A 270 340 V SGT27B13B 270 - 355 V Breakover Voltage v B0 dv/dt = 100V/HS SGT21B13 - - 270 V SGT21B13A 290 V SGT22B13 - - 280 V SGT22B13A 290 V SGT23B13 290 V SGT23B13A 315 V SGT27B13 345 V SGT27B13A 360 V SGT27B13B 375 V Holding Current k 130 mA On-State Voltage Vt l T = 10A 2 V Main Terminal Capacitance Co Vdm = V rm = 50V, Frequency = 1MHz 50 PF Terms and Symbols Vqm (Maximum Off-State Voltage) - Maximum off-state volt- age (DC or peak) which may be applied continuously. V RM (Maximum Reverse Voltage) - Maximum reverse-block- ing voltage (DC or peak) which may be applied. Vsm (Maximum Peak Surge Current) - Maximum nonrepeti- tive current which may be allowed to flow for the time state. T A (Ambient Operating Temperature) - Ambient temperature range permitted during operation in a circuit. T STG (Storage Temperature) - Temperature range permitted during storage. I DM (Off-State Current) - Maximum value of off-state current that results from the application of the maximum off-state voltage (V DM ). Ir m (Reverse Current) - Maximum value of reverse current that results from the application of the maximum reverse voltage (V RM ). V 2 (Clamping Voltage) - off-state voltage at a specified cur- rent. V b (Breakdown Voltage) - voltage at which the device switches from the off-state to the on-state. I H (Holding Current) - Minimum on-state current that will hold the device in the on-state after it has been latched on. V T (On-State Voltage) - Voltage across the main terminals for a specified on-state current. C (Main Terminal Capacitance) - Capacitance between the main terminals at a specified off-state voltage. 8-11 SGT2XB13, SGT2XB13A, SGT27B13B Performance Curves 'DM FIGURE 1. TYPICAL VOLT-AMPERE CHARACTERISTICS FOR ALL TYPES 80 100 120 140 160 180 200 VOLTAGE (V) FIGURE 2. TYPICAL CAPACITANCE vs VOLTAGE FOR ALL TYPES -40 -30 -20 -10 10 20 30 40 50 60 70 AMBIENT TEMPERATURE (°C) FIGURE 3. NORMALIZED ZENER VOLTAGE vs TEMPERATURE FOR ALL TYPES 80 90 § * 1.00 < 0.50 100 1,000 RATE OF RISE OF VOLTAGE (V/ M s) 10,000 FIGURE 4. NORMALIZED V BO vs dv/dt FOR ALL TYPES -40 -30 -20 -10 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (°C) FIGURE 5. NORMALIZED HOLDING CURRENT vs TEMPERATURE FOR ALL TYPES 8-12 SGT2XB13, SGT2XB13A, SGT27B13B Packaging TO-202 Modified 2 LEAD JEDEC STYLE TO-202 SHORT TAB PLASTIC PACKAGE SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX 0.130 3.31 3.81 0.024 0.028 0.61 0.71 2 3 b, 0.045 0.055 1.15 1.39 1 , 2, 3 b 2 0.270 0.280 6.86 7.11 c 0.018 0.022 0.46 0.55 1.2,3 D 0.320 0.340 8.13 8.63 E 0.340 0.360 8.64 9.14 »1 0.200 BSC 5.08 BSC 4 H, 0.080 0.100 2.04 2.54 J, 0.039 0.049 1.00 1.24 5 L 0.410 0.440 10.42 11.17 L, 0.080 0.100 2.04 2.54 1 NOTES: 1. Lead dimension and finish uncontrolled in L,. 2. Lead dimension (without solder). 3. Add typically 0.002 inches (0.05mm) for s 4. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 5. Position of lead to be measured 0.1 00 inches (2.54mm) from bottom of dimension D. 6. Controlling dimension: Inch. 7. Revision 3 dated 10-94. 8-13 m HARRIS SGT27B27, OD SGT27B27A, SGT27B27B March 1995 Bidirectional Transient Surge Suppressors (SURGECTOR™) MT2 MODIFIED TO-202 Features Applications • Clamping Voltage 230V or 270V • Data and Communication Links • Peak Transient Surge Current. . .600A • Computer Modems • Minimum Holding Current . . . 270mA • Alarm Systems • Continuous Protection • Low On-State Voltage • UL Recognized File #E135010 to STD 497B Description These SURGECTOR devices are designed to protect telecom- munication equipment, data links, alarm systems, power sup- plies and other sensitive electrical circuits from damage by switching transients, lightning strikes, load changes, commuta- tion spikes and line crosses. Bidirectional SURGECTOR devices are constructed using two monolithic compound chips each consisting of a thyristor whose gate region contains a special diffused section which acts as a zener diode. This chips are connected in anti parallel, providing bidirectional protection. This zener diode section permits anode voltage turn on of the structure. Initial clamping by the zener diode section, and fast turn on by the thyristor, provide excellent voltage limiting even on very fast rise time transients. The thyristor also features very high holding current, which allows the SURGECTOR to recover to its high impedance off state after a transient. All these devices are supplied in a 2 lead, modified TO-202 VERSATAB package. Absolute Maximum Ratings t c = +25°c Continuous Off State Voltage: Vdm Vrm Transient Peak Surge Current I TSM 1ns x 2ns (Note 1) 8ns x 20ns 10ns x 560ns ions x 1000ns One Half Cycle 50Hz to 60Hz (Note 2) One Second 50Hz to 60Hz, Halfwave Operating Temperature (T A ) Storage Temperature Range (T STG ) NOTES: 1. Unit designed not to fail open below: 900A. 2. One every 30s maximum. Equivalent Schematic Symbols | MT2 SGT27B27, SGT27B27A SGT27B27B UNITS 235 V 235 V 600 A 400 A 250 A 200 A 60 A 30 A -40°C to +85°C °C -40°Cto+150°C °C MT1 SURGECTOR™ is a trademark of Harris Semiconductor MT2 ZZ CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.C. Handling Procedures. Copyright © Harris Corporation 1 995 „ 1 . File Number 3603.1 Specifications SGT27B27, SGT27B27A, SGT27B27B Electrical Specifications At Case Temperature, T c = +25°C, Unless Otherwise Specified TEST LIMITS PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Off-State Current 'dm. 'rm Maximum Rated V DM , V RM T A = +25°C T A = +85°C 200 100 nA M A Clamping Voltage SGT27B27 SGT27B27A SGT27B27B v z l z < 200mA 270 270 270 325 340 355 V V V Breakover Voltage SGT27B27 SGT27B27A SGT27B27B Vbo dv/dt= 100V/ns 345 360 375 V V V Holding Current !« 270 mA On-State Voltage Vt l T = 10A 2 V Main Terminal Capacitance Co Vdm = V rm = 50V, Frequency = 1 MHz 80 — : — pF Terms and Symbols V DM (Maximum Off-State Voltage) - Maximum off-state volt- age (DC or peak) which may be applied continuously. V RM (Maximum Reverse Voltage) - Maximum reverse-block- ing voltage (DC or peak) which may be applied. 'tsm (Maximum Peak Surge Current) - Maximum nonrepeti- tive current which may be allowed to flow for the time state. T A (Ambient Operating Temperature) - Ambient temperature range permitted during operation in a circuit. t stg (Storage Temperature) - Temperature range permitted during storage. I DM (Off-State Current) - Maximum value of off-state current that results from the application of the maximum off-state voltage (V DM ). I RM (Reverse Current) - Maximum value of reverse current that results from the application of the maximum reverse voltage (V RM ). V z (Clamping Voltage) - off-state voltage at a specified cur- rent. V OB (Breakdown Voltage) - voltage at which the device switches from the off-state to the on-state. I H (Holding Current) - Minimum on-state current that will hold the device in the on-state after it has been latched on. V T (On-State Voltage) - Voltage across the main terminals for a specified on-state current. C Q (Main Terminal Capacitance) - Capacitance between the main terminals at a specified off-state voltage. 8-15 SGT27B27, SGT27B27A, SGT27B27B Performance Curves a ; v T DM FIGURE 1 . TYPICAL VOLT-AMPERE CHARACTERISTICS FOR ALL TYPES 80 100 120 140 160 180 200 VOLTAGE (V) FIGURE 2. TYPICAL CAPACITANCE vs VOLTAGE FOR ALL TYPES 1.50 -40 -30 -20 -10 10 20 30 40 50 60 70 AMBIENT TEMPERATURE (°C) FIGURE 3. NORMALIZED ZENER VOLTAGE vs TEMPERATURE FOR ALL TYPES 3 «■* 100 1,000 RATE OF RISE OF VOLTAGE (V/ns) FIGURE 4. NORMALIZED V B0 vs dv/dt FOR / 8-16 SGT27B27, SGT27B27A, SGT27B27B Packaging ACTIVE ELEMENT i ~7 1 r— e, ■ TO-202 Modified 2 LEAD JEDEC STYLE TO-202 SHORT TAB PLASTIC PACKAGE INCHES MILLIMETERS SYMBOL MIN MAX MIN MAX NOTES 1 A 0.130 0.150 3.31 3.81 b 0.024 0.028 0.61 0.71 2,3 bi 0.045 0.055 1.15 1.39 1,2,3 b 2 0.270 0.280 6.86 7.11 c 0.018 0.022 0.46 0.55 1,2,3 D 0.320 0.340 8.13 8.63 E 0.340 0.360 8.64 9.14 *1 0.200 BSC 5.08 BSC 4 H, 0.080 0.100 2.04 2.54 Jl 0.039 0.049 1.00 1.24 5 L 0.410 0.440 10.42 11.17 0.080 0.100 2.04 2.54 1 NOTES: 1 . Lead dimension and finish uncontrolled in L, . 2. Lead dimension (without solder). 3. Add typically 0.002 inches (0.05mm) for solder coating. 4. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 5. Position of lead to be measured 0.1 00 inches (2.54mm) from bottom of dimension D. 6. Controlling dimension: Inch. 7. Revision 3 dated 10-94. 33 SEMICONDUCTOR March 1995 Gate Controlled Unidirectional Transient Surge Suppressor (SURGECTOR™) Features • Blocking Voltage 270V • Peak Transient Surge Current 300A • Minimum Holding Current 230mA • Subnanosecond Clamping Action • Low On-State Voltage • UL Recognize File # E135010 to STD 497B Applications • Telecommunications Equipment • Data and Voice Lines • Computer Modems • Alarm Systems MODIFIED TO-202 Description SURGECTOR transient surge protectors are designed to protect telecommunication equipment, data links, alarm sys- tems, power supplies, and other sensitive electrical circuits from damage that could be caused by switching transients, lightning strikes, load changes, commutation spikes, and line crosses. These devices are fast turn-on, high holding current thyris- tors. When coupled with a user supplied voltage level detec- tor, they provide excellent voltage limiting even on very fast rise time transients. The high holding current allows this SURGECTOR to return to its high-impedance off state after a transient. The SURGECTOR device's normal off state condition in the forward blocking mode is a high impedance, low leakage state that prevents loading of the line. The SGT27S23 is supplied in a 3 lead, modified, TO-202 package. Absolute Maximum Ratings t c = +25°c Continuous Off State Voltage: V DM Vrm Transient Peak Surge Current: Itsm 1u.s x 2us (Note 1) 8|isx20|is 10|is x 560u.s 10ns X 1 000(i s One Half Cycle 50Hz to 60Hz (Note 2) One Second 50Hz to 60Hz, Halfwave Operating Temperature (T A ) . SGT27S23 UNITS 270 V 1 V 300 A 200 A 125 A 100 A 60 A 30 A -40°C to +85°C °C -40°Cto+150°C °C NOTES: 1 . Unit designed not to fail open below: 450A. 2. One every 30s maximum. Equivalent Schematic Symbols ♦? A z SURGECTOR™ is a trademark of Harris Semiconductor CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.e. Handling Procedures. Copyright © Ham's Corporation 1995 File Number 2762.1 8-18 Specifications SGT27S23 Electrical Specifications At Case Temperature, T c = +25°C, Unless Otherwise Specified PARAMETERS SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Off-State Current 'dm V DM = 270V at T c = +85°C - - 100 50 nA uA Irm at T c = +85°C 1 10 mA mA Holding Current Ih 230 mA On-State Voltage Vt l T =10A 2 V Gate Trigger Current Igt 175 mA Main Terminal Capacitance Co V D M = 0V, Freq = 1MHz V DM = 50V 90 50 PF PF Performance Curves II" 'dm Ih -J —> v z Vdm FIGURE 1. TYPICAL VOLT-AMPERE CHARACTERISTICS 2.0 1 1.8 £ UJ 1.6 E o 1.4 13 Z 1.2 Q -J O X 1.0 a UJ LIZ 0.8 < E o 0.6 2 0.4 -40 -20 20 40 60 AMBIENT TEMPERATURE (°C) FIGURE 2. NORMALIZED GATE TRIGGER CURRENT vs TEMPERATURE -40 -20 20 40 60 80 AMBIENT TEMPERATURE (°C) FIGURE 3. NORMALIZED HOLDING CURRENT vs TEMPERATURE 8-19 SGT27S23 Terms and Symbols y DM (Maximum Off-State Voltage) - Maximum off-state volt- age (DC or peak) which may be applied continuously. V RM (Maximum Reverse Voltage) - Maximum reverse- block- ing voltage (DC or peak) which may be applied. 'tsm (Maximum Peak Surge Current) - Maximum nonrepeti- tive current which may be allowed to flow for the time state. T A (Ambient Operating Temperature) - Ambient temperature range permitted during operation in a circuit. T STG (Storage Temperature) - Temperature range permitted during storage. I dm (Off-State Current) - Maximum value of off-state current that results from the application of the maximum off-state voltage (V DM ). IpM (Reverse Current) - Maximum value of reverse current that results from the application of the maximum reverse voltage (V RM ). I H (Holding Current) - Minimum on-state current that will hold the device in the on-state after it has been latched on. V T (On-State Voltage) - Voltage across the main terminals for a specified on-state current. I GT (Gate-Trigger Current) - Minimum gate current which will cause the device to switch from the off-state to the on-state. C (Main Terminal Capacitance) - Capacitance between the main terminals at a specified off-state voltage. Plastic Packages ACTIVE ELEMENT b 2 - T OTTH 45° I I TO-202 Modified 3 LEAD JEDEC STYLE TO-202 SHORT TAB PLASTIC PACKAGE SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.130 0.150 3.31 3.81 b 0.024 0.028 0.61 0.71 2, 3 b, 0.045 0.055 1.15 1.39 1, 2, 3 b 2 0.270 0.280 6.86 7.11 c 0.018 0.022 0.46 0.55 1,2,3 D 0.320 0.340 8.13 8.63 E 0.340 0.360 8.64 9.14 e 0.100 TYP 2.54 TYP 4 ei 0.200 BSC 5.08 BSC 4 H, 0.080 0.100 2.04 2.54 J, 0.039 0.049 1.00 1.24 5 L 0.410 0.440 10.42 11.17 Li 0.080 0.100 2.04 2.54 1 NOTES: 1. Lead dimension and finish uncontrolled in L,. 2. Lead dimension (without solder). 3. Add typically 0.002 inches (0.05mm) for solder coating. 4. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 5. Position of lead to be measured 0. 1 00 inches (2.E of dimension D. 6. Controlling dimension: Inch. 7. Revision 3 dated 10-94. from bottom - 8-20 TVS INTEGRATED PROTECTION CIRCUITS PAGE PROTECTION CIRCUITS SELECTION GUIDE 9-2 INTEGRATED PROTECTION CIRCUITS DATA SHEETS SP710 Protected Power Switch with Transient Suppression 9-3 SP720 Electronic Protection Array for ESD and Over-Voltage Protection 9-6 SP721 Electronic Protection Array for ESD and Over-Voltage Protection 9-11 HIP1090 Protected High Side Power Switch with Transient Suppression 9-16 Protection Circuits Selection Guide PART iiu ivi l_> i_ n DESCRIPTION ucflumr I lull v. v cc TURN-ON VOLTAGE PROTECTION THRESHOLD TEMPERATURE RANGE SP710 Protected Power Switch with Transient Suppression 4VtO 16V 16V to 18.5V -40°Cto+105°C HIP1090 Protected High Side Power Switch with Transient Suppression 4Vto16V (Expandable) 16V to 19V -40°Cto+105°C SP720 Electronic Protection Array for ESD and Overvoltage Protection, 14 Inputs 4.5V to 30V +V BE Above V cc or -V BE Below GND -40°Cto+105°C SP721 Electronic Protection Array for ESD and Overvoltage Protection, 6 Inputs 4.5V to 30V +V BE Above V cc or -V BE Below GND -40°Cto+105°C 9-2 SEMICONDUCTOR SP710 March 1995 Protected Power Switch with Transient Suppression Description The SP710 is a Power Integrated Circuit designed to suppress potentially damaging over-voltage transients up to ±90V in amplitude. The device is designed to be operated in a pass-thru mode which allows the current to flow through the IC with minimal voltage drop. The protected load circuit is connected to the output of the SP710. As such, the protected power switch IC is designed to operate as a transient suppressor which is capable of driving resistive, inductive or lamp loads with minimum risk of damage under stress conditions of over-voltage or over current. The SP710 is supplied in a 3 lead TO-220AB package. Ordering Information Features • ±90V Transient Suppression • 4V to 1 6V Operating Voltage • 0.8A Current Load Capability • Over-Voltage Shutdown Protected • Short-Circuit Current Limiting • Over-Temperature Protected Thermal Limiting at150°C(Tj) • -40°C to +125°C Operating Temperature Range Applications • Electronic Circuit Breaker • Transient Suppressor • Over-Voltage Monitor PART NUMBER TEMPERATURE RANGE PACKAGE SP710AS -40°Cto+125°C 3 Lead Plastic SIP Pinout SP710(SIP) TOP VIEW NOTE: HEAT SINK TAB INTERNALLY o Functional Block Diagram »IN io- (Vcc OR Vbatt) THERMAL LIMIT -Wv CURRENT LIMIT Wr v OVER- VOLTAGE SHUTDOWN BASE CURRENT AMPLIFIER V CE SAT DETECTOR VoUT — O 3 (TO LOAD) 2 6 V C0MM0N CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.e. Handling Procedures. Copyrighl © Harris Corporation 1995 Q „ File Number 2789.7 Specifications SP710 Absolute Maximum Rati rigs Thermal Information I Input Voltage, V, N 24V Thermal Resistance 8 JA 9 JC Load Current, l 0UT 800mA Plastic SIP 50°C/W 4°C/W Transient Max Voltage, V, N (15ms) ±90V Junction Temperature 150°C Ambient Operating Temperature -40°C to +125°C NOTE: P D = (V, N - V ) (l Q ) + (V, N ) Ocommon) Storage Temperature -40°C to +1 50°C Tj = T A + (P D ) (Thermal Resistance) Lead Temperature (During Soldering) 265°C 1/16in. ± 1/32in. (1.59mm ± 0.79mm) from case for 10s maximum CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation ol the device at these or any other conditions above those indicated in the operational sections ot this specification is not implied. Electrical Specifications T A = -40°C to +125°C, V, N = 4V to 16V, Unless Otherwise Specified PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Input Operating Voltage V|N 4 16 V Shutdown Voltage V SHSD 16 18.5 V Shutdown Temperature 150 °c Transient Pulse 'out V, N = ±90V for 15ms Pin 3 = 14V, Pin 2 = GND -20 +20 mA Short Circuit Current 1 2 A V SAT (Input-to-Output) V|N = 4 V, l 0UT = 175mA 0.25 V V| N = 9V, I ut = 500mA 0.65 V V, N = 16V, I ut = 800mA 1.05 V Common Current 'com V| N = 16V, l 0UT = 100mA 25 mA V| N = 16V. I 0UT = 800mA 50 mA Typical Application THERMAL -VvV CURRENT LIMIT OVER- VOLTAGE SHUTDOWN BASE CURRENT AMPLIFIER v 0UT V CE SAT DETECTOR V COMMON (GND) DASH PANEL LOAD 111 3 0.47 M fT TO OTHER LIGHTS AND INSTRUMENTS V[_OAD = V BATT - V SAT ( V SAT TYP. <1V AT 800mA) 9-4 SP710 Packaging Lead No. 1 - Gate Lead No. 2 - Collector Lead No. 3 - Emitter Mounting Flange - Collector TO-220AB 3 LEAD JEDEC TO-220AB PLASTIC PACKAGE INCHES MILLIMETERS NOTES SYMBOL MIN MAX MIN MAX A 0.170 0.180 4.32 4.57 Ai 0.048 0.052 1.22 1.32 b 0.030 0.034 0.77 0.86 3.4 &1 0.045 0.055 1.15 1.39 2,3 c 0.014 0.019 0.36 0.48 2, 3,4 D 0.590 0.610 14.99 15.49 D, 0.160 4.06 E 0.395 0.410 10.04 10.41 Et 0.030 0.76 e 0.100 TYP 2.54 TYP 5 B1 0.200 BSC 5.08 BSC 5 H, 0.235 0.255 5.97 6.47 Ji 0.100 0.110 2.54 2.79 6 L 0.530 0.550 13.47 13.97 Li 0.130 0.150 3.31 3.81 2 0P 0.149 0.153 3.79 3.88 Q 0.102 0.112 2.60 2.84 - NOTES: 1 . These dimensions are within allowable dimensions of Rev. J of JEDEC TO-220AB outline dated 3-24-87. 2. Lead dimension and finish uncontrolled in Lp 3. Lead dimension (without solder). 4. Add typically 0.002 inches (0.05mm) for solder coating. 5. Position of lead to be measured 0.250 inches (6.35mm) from bot- tom of dimension D. 6. Position of lead to be measured 0.1 00 inches (2.54mm) from bot- tom of dimension D. 7. Controlling dimension: Inch. 8. Revision 1 dated 1-93. SI SEMICONDUCTOR SP720 March 1995 Electronic Protection Array for ESD and Over-Voltage Protection Features • ±2A Peak Current Capability • Single-Ended Voltage Range to +35V • Differential Voltage Range to +17.5V • Designed to Provide Over-Voltage Protection • Fast Switching 6ns Risetime • Low Input Leakages of 1 nA at +25°C Typical • Low Input Capacitance of 3pF Typical • An Array of 14 SCR/Diode Pairs • Proven Interface for ESD • Operating Temperature Range -40°C to +105°C Applications • Microprocessor/Logic Input Protection • Data Bus Protection • Analog Device I • Voltage Clamp Description The SP720 is an array of SCR/Diode bipolar structures for ESD and over-voltage protection to sensitive input circuits. The SP720 has 2 protection SCR/Diode device structures per input. A total of 14 available inputs can be used to protect up to 14 external signal or bus lines. Over-voltage protection is from the IN (pins 1-7 and 9-15) to V+ or V-. The SCR structures are designed for fast triggering at a threshold of one +V BE diode threshold above V+ (Pin 16) or a -V BE diode threshold below V- (Pin 8). From an IN input, a clamp to V+ is activated if a transient pulse causes the input to be increased to a voltage level greater than one V BE above V+. A similar clamp to V- is activated if a negative pulse, one V BE less than V-, is applied to an IN input. Refer to Application Note AN9304 for further Ordering Information PART NUMBER TEMPERATURE PACKAGE SP720AP -40°Cto+105°C 16 Lead Plastic DIP SP720AB -40°C to +105°C 16 Lead Plastic SOIC(N) SP720ABT -40°Cto+105°C 16 Lead Plastic SOIC Tape and Reel Pinout SP720 (PDIP, SOIC) TOP VIEW IN fT if] v+ IN (T jH IN IN [I iJJ IN IN fT n] in IN [? i3] IN IN f? jTJ IN IN [7 joj IN v-n JJ IN Functional Block Diagram CAUTION: These devices are sensitive to el> Copyright © Harris Corporation 1995 should follow proper I.e. Handling Procedures. File Number 2791.6 Specifications SP720 Absolute Maximum Ratings Continuous Supply Voltage, (V+) Input Peak Current, l IN Transient Ratings - See Note (V-) +35V ±2A ', Figure 1, Table 1 " Thermal Information Thermal Resistance 8 JA 16 Lead PDIP Package 90°C/W 16 Lead SOIC Package 170°C/W Maximum Package Power Dissipation at +105°C Plastic DIP Package 500mW Plastic SOIC Package 270mW Storage Temperature Range -65°C to +150°C Junction Temperature +150°C Lead Temperature (Soldering 10s) +265°C CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections ot this specification is not implied. Electrical Specifications T A = -40°C to +105°C; V iN = 0.5V CC Unless Otherwise Specified PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Operating Voltage Range, VSUPPLY = (-v cc INPUT DRIVERS OR SIGNAL SOURCES T" SP720 » IN 9-15 LINEAR OR DIGITAL IC INTERFACE TO +V CC 1 SP720 INPUT PROTECTION CIRCUIT (1 OF 14 ON CHIP) FIGURE 4. TYPICAL APPLICATION OF THE SP720 AS AN INPUT CLAMP FOR OVER-VOLTAGE, GREATER THAN 1 V BE ABOVE V+ OR LESS THAN -1 V BE BELOW V- 9-8 E16.3 (JEDEC MS-001-BB ISSUE D) 16 LEAD DUAL-IN-LINE PLASTIC PACKAGE NOTES: 1 . Controlling Dimensions: INCH. In case of conflict between English and Metric dimensions, the inch dimensions control. 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Symbols are defined in the "MO Series Symbol List" in Section 2.2 of Publication No. 95. 4. Dimensions A, A1 and L are measured with the package seated in JEDEC seating plane gauge GS-3. 5. D, D1, and E1 dimensions do not include mold flash or protru- sions. Mold flash or protrusions shall not exceed 0.010 inch (0.25mm). 6. E and [e^] are mea sured with the leads constrained to be per- pendicular to datum | -C- 1 . 7. e B and e c are measured at the lead tips with the leads uncon- strained. e c must be zero or greater. 8. B1 maximum dimensions do not include dambar protrusions. Dambar protrusions shall not exceed 0.010 inch (0.25mm). 9. N is the maximum number of terminal positions. 10. Comer leads (1, N, N/2 and N/2 + 1) for E8.3, E16.3. E18.3, E28.3, E42.6 will have a B1 dimension of 0.030 - 0.045 inch (0.76 - 1.14mm). SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.210 5.33 4 A1 0.015 0.39 4 A2 0.115 0.195 2.93 4.95 - B 0.014 0.022 0.356 0.558 B1 0.045 0.070 1.15 1.77 8, 10 C 0.008 0.014 0.204 0.355 . D 0.735 0.775 18.66 19.68 5 D1 0.005 0.13 5 E 0.300 0.325 7.62 8.25 6 E1 0.240 0.280 6.10 7.11 5 e 0.100 BSC 2.54 BSC - e A 0.300 BSC 7.62 BSC 6 e B 0.430 10.92 7 L 0.115 0.150 2.93 3.81 4 N 16 16 9 Rev. 12/93 9-9 NOTES: 1. Symbols are defined in the "MO Series Symbol List" in Section 2.2 of Publication Number 95. 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Dimension "D" does not include mold flash, protrusions or gate burrs. Mold flash, protrusion and gate burrs shall not exceed 0.1 5mm (0.006 inch) per side. 4. Dimension "E" does not include interlead flash or protrusions. In- terlead flash and protrusions shall not exceed 0.25mm (0.010 inch) per side. 5. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 6. "L" is the length of terminal for soldering to a substrate. 7. "N" is the number of terminal positions. 8. Terminal numbers are shown for reference only. 9. The lead width "B", as measured 0.36mm (0.014 inch) or greater above the seating plane, shall not exceed a maximum value of 0.61mm (0.024 inch) 10. Controlling dimension: MILLIMETER. Converted inch dimen- sions are not necessarily exact. v _. . ...^t,,^ „~ v,; 16 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.0532 0.0688 1.35 1.75 A1 0.0040 0.0098 0.10 0.25 - B 0.013 0.020 0.33 0.51 9 C 0.0075 0.0098 0.19 0.25 D 0.3859 0.3937 9.80 10.00 3 E 0.1497 0.1574 3.80 4.00 4 e 0.050 BSC 1.27 BSC - H 0.2284 0.2440 5.80 6.20 h 0.0099 0.0196 0.25 0.50 5 L 0.016 0.050 0.40 1.27 6 N 16 16 7 a 0° 8° 0° 8° Rev. 12/93 9-10 33 SEMICONDUCTOR SP721 March 1995 Electronic Protection Array for ESD and Over-Voltage Protection Features • ±2A Peak Current Capability • Single-Ended Voltage Range to +35V • Differential Voltage Range to±17.5V • Designed to Provide Over-Voltage Protection • Fast Switching 6ns Risetime • Low Input Leakages of 1 n A at +25°C Typical • Low Input Capacitance of 3pF Typical • An Array of 6 SCR/Diode Pairs • Proven Interface for ESD • Operating Temperature Range -40°Cto+105°C Applications • Microprocessor/Logic Input Protection • Data Bus Protection • Analog Device Input Protection • Voltage Clamp Description The SP721 is an array of SCR/Diode biploar structures for ESD and over-voltage protection to sensitive input circuits. The SP721 has 2 protection SCR/Diode device structures per input. There are a total of 6 available inputs that can be used to protect up to 6 external signal or bus lines. Over- voltage protection is from the IN (Pins 1 - 3 and Pins 5 - 7) to V+ or V-. The SCR structures are designed for fast triggering at a threshold of one +V BE diode threshold above V+ (Pin 8) or a -V BE diode threshold below V- (Pin 4). From an IN input, a clamp to V+ is activated if a transient pulse causes the input to be increased to a voltage level greater than one V BE above V+. A similar clamp to V- is activated if a negative pulse, one V BE less than V-, is applied to an IN input. Further information is available in Application Note AN9304 applies to both the SP720 and SP721 . Ordering Information PART NUMBER TEMPERATURE RANGE PACKAGE SP721AP -40°Cto+105°C 8 Lead Plastic DIP SP721AB -40°Cto+105°C 8 Lead Plastic SOIC (N) SP721ABT -40°Cto+105°C 8 Lead Plastic SOIC Tape and Reel Pinout SP721 (PDIP, SOIC) TOP VIEW IN (T JJ v+ IN (T 7] IN IN [7 7] IN v-f7 JJlN Functional Block Diagram CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.e. Handling Procedures. Copyright © Harris Corporation 1 995 „ . . File Number 3590.2 Specifications SP721 Absolute Maximum Ratir tings Continuous Supply Voltage, (V+) - (V-) Input Peak Current, l IN ESD Transient Ratings - See Note 2, Figure 1 , Table 1 +35V . ±2A 130°C/W Thermal Resistance 8 Lead DIP Package 8 Lead SOIC Package 1 70°C/W Maximum Package Power Dissipation 8 Lead Plastic DIP Package, Up to +105°C 350mW 8 Lead Plastic SOIC Package, Up to +105°C 270mW Storage Temperature Range -65°C to +150°C Junction Temperature +150°C Lead Temperature (Soldering 1 0s) +265°C CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Electrical Specifications T A = -40°C to +105°C, V, N - 0.5V CC Unless Otherwise Specified PARAMETERS SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Operating Voltage Range, Vsupply = l(V+) • (V-)] V SUPPLY 4.5 to 30 V Forward Voltage Drop IN to V- IN to V+ V FWDL V FWDH |, N = 1A (Peak Pulse) 2 2 V Input Leakage Current ■in ■20 5 +20 nA Quiescent Supply Current 'quiescent 50 200 nA Equivalent SCR ON Threshold Note 3 1.1 V Equivalent SCR ON Resistance v fwd/Ifwd: Note 3 1 Q Input Capacitance Pin 3 PF Input Switching Speed •on 6 ns NOTES: 1 . In automotive and battery operated systems, the power supply lines should be externally protected for load dump and reverse battery. When the V+ and V- Pins are connected to the same supply voltage source as the device or control line under protection, a current limiting resistor should be connected in series between the external supply and the SP721 supply pins to limit reverse battery current to within the rated maximum limits. Bypass capacitors of typically 0.01 (iF or larger from the V+ and V- Pins to ground are recommended. 2. For ESD testing of the SP721 to MIL-STD 883, Method 301 5.7, Human Body Model (HBM), the results are typically betterthan 6kV (Con- dition 1) (Figure 1, Table 1). Transient and ESD capability is highly dependent on the application. For conditions that are defined as an in-circuit method of ESD testing where the V+ and V- Pins have a return path to ground, the ESD capability is typically greater than 1 5kV from 100pF through 1.5k£2 (Condition 2) or 9kV from 200pF through 1 ,5kQ (Condition 3). For ESD testing of the SP721 to EIAJ IC121 Machine Model (MM), the results are typically better than 1kV (Condition 4). 3. Refer to the Figure 3 graph for definitions of equivalent "SCR ON Threshold" and "SCR ON Resistance". These characteristics are given here for thumb-rule information to determine peak current and dissipation under EOS conditions. -Wr TABLE 1. ESD TEST CONDITIO!* H.V. SUPPLY ±Vn IN DUT R, - 10M£i FIGURE 1. ELECTROSTATIC DISCHARGE TEST MIL-STD-883D, METHOD 3015.7 TEST ±v D Rd Co Condition 1 6kV 1.5kn 100pF (HBM) Condition 2 15kV 1.5W1 100pF (Mod. HBM) Condition 3 9kV 1.5kQ 200pF (Mod. HBM) Condition 4 1kV 0k£2 200pF (MM) 9-12 SP721 a 40 S T A = +2S SINGLE °C PULSE / f S00 1000 FORWARD SCR VOLTAGE DROP (mV) T A = +25°C SINGLE PULSE EQUIV. SAT. ON THRESHOLD - 1.1V FORWARD SCR VOLTAGE DROP (V) FIGURE 2. LOW CURRENT SCR FORWARD VOLTAGE DROP CURVE FIGURE 3. HIGH CURRENT SCR FORWARD VOLTAGE DROP CURVE ♦Vcc 4 INPUT DRIVERS OR SIGNAL SOURCES IN5-7 linear or digital ic [ interface! TO W cc a z ill o «i i- s ^ UJ o £ Q. SP721 INPUT PROTECTION CIRCUIT (1 OF 14 ON CHIP) (PINOUT CONFIGURATION SHOWN FOR S PIN PACKAGES) FIGURE 4. TYPICAL APPLICATION OF THE SP721 AS AN INPUT CLAMP FOR OVER-VOLTAGE, GREATER THAN 1 V BE ABOVE V+ OR LESS THAN -1 V BE BELOW V- 9-13 SP721 Dual-ln-Line Plastic Packages (PDIP) E1 E8.3 (JEDEC MS-001-BA ISSUE D) 8 LEAD DUAL-IN-LINE PLASTIC PACKAGE BASE | -I! 1 j SEATING PLANE $| 0.010 (0.25)(g)|c| A|B® NOTES: 1. Controlling Dimensions: INCH. In case of conflict between English and Metric dimensions, the inch dimensions control. 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Symbols are defined in the "MO Series Symbol List" in Section 2.2 of Publication No. 95. 4. Dimensions A, A1 and L are measured with the package seated in JEDEC seating plane gauge GS-3. 5. D, D1 , and E1 dimensions do not include mold flash or protru- sions. Mold flash or protrusions shall not exceed 0.010 inch (0.25mm). 6. E and | e A | are mea sured with the leads constrained to be per- pendicular to datum | -C- 1 . 7. e B and e c are measured at the lead tips with the leads uncon- strained. e c must be zero or greater. 8. B1 maximum dimensions do not include dambar protrusions. Dambar protrusions shall not exceed 0.010 inch (0.25mm). 9. N is the maximum number of terminal positions. 10. Corner leads (1, N, N/2 and N/2 + 1) for E8.3, E16.3, E18.3, E28.3, E42.6 will have a B1 dimension of 0.030 - 0.045 inch (0.76- 1.14mm). SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.210 5.33 4 A1 0.015 0.39 4 A2 0.115 0.195 2.93 4.95 - B 0.014 0.022 0.356 0.558 - B1 0.045 0.070 1.15 1.77 8. 10 C 0.008 0.014 0.204 0.355 - D 0.355 0.400 9.01 10.16 5 D1 0.005 5 E 0.300 0.325 7.62 8.25 6 E1 0.240 0.280 6.10 7.11 5 e 0.100 BSC 2.54 BSC eA 0.300 BSC 7.62 BSC 6 e B 0.430 10.92 7 L 0.115 0.150 2.93 3.81 4 N 8 8 9 9-14 INDEX / AREA I \ t h| B ill m y y y 0.25(0.010) ( M8.15 (JEDEC MS-012-AA ISSUE C) 8 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE ESDI--] □ la- j Qj] NOTES: 1 . Symbols are defined in the "MO Series Symbol Lisf in Section 2.2 of Publication Number 95. 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Dimension "D" does not include mold flash, protrusions or gate burrs. Mold flash, protrusion and gate burrs shall not exceed 0.1 5mm (0.006 inch) per side. 4. Dimension "E" does not include interlead flash or protrusions. In- terlead flash and protrusions shall not exceed 0.25mm (0.010 inch) per side. 5. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 6. "L" is the length of terminal for soldering to a substrate. 7. "N" is the number of terminal positions. 8. Terminal numbers are shown for reference only. 9. The lead width "B", as measured 0.36mm (0.01 4 inch) or greater above the seating plane, shall not exceed a maximum value of 0.61mm (0.024 inch). 10. Controlling dimension: MILLIMETER. Converted inch dimen- sions are not necessarily exact. SYMBOL INCHES MILLIMETERS NOTES MIN MAX MIN MAX A 0.0532 0.0688 1.35 1.75 - A1 0.0040 0.0098 0.10 0.25 - B 0.013 0.020 0.33 0.51 9 C 0.0075 0.0098 0.19 0.25 D 0.1890 0.1968 4.80 3 E 0.1497 0.1574 3.80 4.00 4 e 0.050 BSC 1.27 BSC - H 0.2284 0.2440 5.80 6.20 - h 0.0099 0.0196 0.25 0.50 5 L 0.016 0.050 0.40 1.27 6 N 8 8 7 a 0° 8° 0° 8° Rev. 12/93 UJ O ■I 9-15 SEMICONDUCTOR March 1995 Protected High Side Power Switch with Transient Suppression Features • ±90V Transient Suppression • 4V to 16V Operating Voltage • 1 A Current Load Capability • Low Input-Output Voltage Drop With Controlled Saturation Detector for - Fast Low Current Turn-OFF - Reduced No-Load Idle Current • Over-Voltage Shutdown Protection • Short Circuit Current Limiting • Over-Temperature Limiting Protected • Thermal Limiting at Tj = +150°C • -40°C to +125°C Operating Temperature Range Applications • Electronic Circuit Breaker • Transient Suppressor • Over-Voltage Monitor • High Side Driver Switch for - Relays - Solenoids - Heaters - Motors - Lamps Ordering Information PART NUMBER TEMPERATURE RANGE PACKAGE HIP1090AS -40°Cto+125°C TO-220AB SIP Description The HIP1090 is a Protected Power Interface Switch designed to suppress potentially damaging over-voltage transients with peak voltage source inputs ranging up to ±90V in amplitude. It is designed to be operated in a 'hard- wired' pass-thru mode or as a high side power switch which controls the current flow through a PNP pass transistor of the IC. In either mode The HIP1090 has a low saturated forward voltage drop. The protected load circuit is connected to the output of the IC. As such, the HIP1090 operates as a transient suppressor where the PNP drive transistor is switched off when V| N is greater than the Over- Voltage Shut- down range of 16V to 19V. Shutdown also occurs when V !N is less than the forward turn-on threshold of approximately 2.5V, including the negative voltage range. The merits of transient suppression depend on the required integrity of the applications load elements. Instrument panel signal warning lights for critical functions such as over- temperature or low fluid levels can be protected by the HIP1090 against high level transient voltages and double battery conditions that may potentially cause bulb burnouts. The HIP1090 may be used to protect the power supplies of small signal or logic circuits with voltages ranging from 4V to 16V, effectively blocking higher peak voltages. The HIP1090 has internal current limiting protection in the range of 1 A to 2A for short circuit to ground conditions and thermal shutdown protection when the junction temperature is greater than 150°C. It is capable of driving resistive, inductive or lamp loads (such as lamps No. 168 or 194) with minimum risk of damage under harsh environmental stress conditions. The HIP1090 is supplied in a 3 lead TO-220AB package. Pinout HIP1090(SIP) TOP VIEW NOTE: HEAT SINK TAB INTERNALLY CONNECTED TO PIN 2 ? 2 > Sis Functional Block Diagram (V CC OR Vbatt) THERMAL LIMIT -Wv CURRENT LIMIT OVER- VOLTAGE SHUTDOWN BASE CURRENT AMPLIFIER V CE SAT DETECTOR -°v 0UT (TO LOAD) 2 4 V CON (CONTROL OR GND) CAUTION: These devices are sensitive lo electrostatic discharge. Users should follow proper I C. Handling Procedures. Copyright © Harris Corporation 1 995 g ^ g File Number 3398.3 Specifications HIP 1090 Absolute Maximum Ratings Input (Supply) Voltage, V, N (Control Pin Reference) ±24V Transient Max Voltage, V !N (15ms) ±90V Load Current, l 0UT Short Circuit Protected Thermal Information Thermal Resistance e JA e JC Plastic SIP Package 50°C/W 4°C/W Maximum Power Dissipation, (Note 4) AtT A = +105°C, Infinite Heat Sink 11.25W Junction Temperature +150°C Ambient Temperature Range -40°C to +125°C Storage Temperature Range -40°C to +150°C Lead Temperature (Soldering During) +265°C 1/1 6 ± 1/32 inch (1.59 ± 0.79mm) from case for 10s maximum CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Electrical Specifications T A = -40°C to +125°C; V, N = 4V to 16V; V C0N = GND or 0V, Unless Otherwise Specified PARAMETERS SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Input (Supply) Voltage Operating Range V,N (Note 1); Also, See Figure 4 for Expanding V, N Range 4 16 V Input Voltage Threshold for Forward Turn-On to Load Vthd Load = 1kn 2.5 V Input Voltage for Output Shutdown V SHSD (Note 2) 16 19 V Output Shutdown Leakage V| N = 19V and 24V; Load = 1k£2 100 MA Output Cutoff Leakage 'LEAK2 V IN = 16V; Control Open; Load = 1kQ - 1 HA Thermal Shutdown Temperature T SD 1 50 op Maximum Output Transient Pulse Current l 0UT (Tran) V, N = ±90V for 15ms, V 0UT = 14V -20 +20 mA Maximum Control Transient Pulse Current l CON (Tran) V| N = ±90 V for 15ms, V 0UT = 14V -50 +50 mA Short Circuit Current Isc 1 2 A Input-to-Output Voltage Drop V|N = 4V, l OU T = 175mA 0.25 V V| N = 9V, l 0UT = 500mA 0.65 V Vin = 16V . Iout = 800mA 1.05 V V IN = 16V, l 0U T=1A 0.8 V Control Current 'con V, N = 16V, l OUT = 100mA 25 mA V, N = 16V, l 0UT = 800mA 50 mA V IN = 16V.I 0UT =1A 50 mA Turn ON (Rise Time); "Pass-Thru" Mode •on Switch V, N OV(GND) to 5.5V; Mea- sure V 0UT (to 90%); Load = 1k£2 (Note 3) 20 MS Turn OFF (Fall Time); "Pass-Thru" Mode •off Switch V, N 5.5V to OV(GND); Mea- sure V 0UT (to 90%); Load = 1kfi (Note 3) 20 US Turn ON (Rise Time); High Pass Switch Mode •on See Figure 3 and Figure 4 (Note 3) 15 US Turn OFF (Fall Time); High Pass Switch Mode 'off See Figure 3 and Figure 4 (Note 3) 15 ps NOTES: 1 . The Input Operating Voltage is not limited by the threshold of Shutdown. The V| N voltage may range to +24V while the normal functional switching range is typically +2.5V to +17.5V (reference to V C0N ). 2. The Output Drive is switched-off when the Input voltage(Supply pin), referenced to the Control pin exceeds the threshold shutdown VSHSD or the input voltage is less than the forward turn-on threshold (Including negative voltages within the transient peak ratings). 3. T 0N and T OFF times include Prop Delay and Rise/Fall time. 4. The worst case thermal resistance,e JC for the SIP TO-220 is 4°C/W. The calculation for dissipation and junction temperature rise due to dissipation is: Pd = (V,N -V 0UT ) + (V, n )(Icon ) T J = t ambient + ( p D> (9jc) 'or an infinite Heat Sink. Derating from 150°C is based on the reciprocal of thermal resistance, 9jc+9hs- For example: Where 8 JC = 4°C/W and given 8 HS = 6°AA/ as the thermal resistance of an external Heat Sink, the junction-to-air thermal resistance, e JA = 10°CAfV. Therefore, for the maximum allowed dissipation, derate 0.1 W/°C for each degree from T AMB to the maximum rated junction temperature of 1 50°C. If T AMB = 1 00°C, the maximum P D is (150 - 100) x 0.1W7°C = 5W. HIP 1090 Applications The HIP1090 may be used as a "hard-wired pass-thru" device to protect the load from source voltage transients or may be used as an active high side power interface switch with up to 1A of Load current capability. An ON state condition of (V, N - 4V) < V C0N < (V, N - 16V) is the normal range required to activate the high pass switch, allowing the supply source to conduct through the PNP to the load. When the control terminal, V CON is open, the high pass switch is open (no conduction). Figure 2 shows an HIP1090 application example with a switch in the V CO n terminal. In comparison to the hard wired circuit of Figure 1 where pin 2 is fixed at ground, pin 2 in the circuit of Figure 2 is switched from open to ground to turn-ON the high pass switch. Used in this mode, the HIP1090 is both an effective transient suppressor and a high pass switch. The switch in the V C0N terminal may be active or passive and conducts typically less than 50mA of current. The HIP1090 used in the con- trolled switching mode retains all of the protected features of the device. In either circuit the output capacitor may be increased in size to hold charge longer during transient interruptions at the input. The charge duration for larger capacitors or for lamp loads is tolerated because of the internal short circuit current limiting protection. Sustained short circuits may cause the junction temperature to reach the thermal shutdown temperature (150°C). INPUT 1 SWITCH \ Vbatt THERMAL LIMIT -Wr CURRENT LIMIT OVER- VOLTAGE SHUTDOWN 1 F BASE CURRENT AMPLIFIER V CE SAT DETECTOR DASH PANEL LOAD TO OTHER LIGHTS AND INSTRUMENTS V CON (CONTROL OR GND) FIGURE 1. TYPICAL APPLICATION OF THE HIP1090 AS A TRANSIENT SUPPRESSOR IN A "PASS-THRU" MODE INPUT 1 Vbatt ►» THERMAL LIMIT -Wr CURRENT LIMIT OVER- VOLTAGE SHUTDOWN BASE CURRENT AMPLIFIER NOTE: v loao = Vbatt ■ v sat VsAT Tvp <0.8Vat1A V CE SAT DETECTOR "CON (CONTROL) OFF x * ON SWITCH ' "1 0.47mF TO 1000uF r i FIGURE 2. TYPICAL APPLICATIONS OF THE HIP1090 AS A TRANSIENT SUPPRESSOR IN A HIGH PASS SWITCH MODE 9-18 HIP1090 Figure 3 shows the pulsed output switching characteristics of the HIP1090 as a high side driver. A small delay step is noted on the rising edge due to the hold-off of a V CE SAT detector circuit. The V^gSAT circuit senses the saturation level of the PNP pass transistor and controls the drive as a ratio of load current. As the load current is reduced, the drive current to the output transistor is reduced. Under low current operation, the saturation level is controlled and the turn-OFF switching time is much faster. The control switching element is shown as a 2N5320 NPN transistor but may be any open collector or MOS gate. A pull-up resistor of 2kii is used for a slight improvement in the turnoff fall time but is not an essential requirement. The V CO n terminal may be controlled with a mechanical switch or may be controlled from any driver output that can sink the worst case condition of pin 2 current, l CON when the output load current is increased to 1 A (typically 50mA). The circuit of Figure 4 shows how the HIP1090 transient suppression voltage shutdown threshold may be increased by using a zener diode from the V C0N terminal to the collec- tor terminal of the transistor switch. The preferred method is to use a zener diode for a fixed level shift. While a resistor in place of the zener diode having the same voltage drop will work well, the parametric variation of the l CON current will cause variations of the Over-Voltage Shutdown Threshold. In this circuit, a 10V zener provides a typical over-voltage threshold shift to -27V. The threshold for over-voltage shut- down is referenced to the (V, N - V CON ) voltage difference. +24V (SUPPLY INPUT) Ska OPTIONAL +16V (SUPPLY INPUT) OPTIONAL HIP1090 jit —^(OUTPUT) ON <^W^-K j V CON -=- (OUTPUT) MQ o Wv <" v CON (CONTROL PIN) 2N5320 OR EQUIVALENT 2NS320 OR EQUIVALENT OFF FIGURE 3. TYPICAL ON-OFF SWITCHING CHARACTERISTIC OF THE HIP1090 USING AN NPN TRANSISTOR TO SWITCH THE V CON INPUT TERMINAL FIGURE 4. A TYPICAL APPLICATION CIRCUIT THAT USES A ZENER TO THE V CON TRANSISTOR SWITCH TO RAISE THE OVER-VOLTAGE SHUTDOWN THRESHOLD Also, it is important to note that high peak current values may be reached when driving nonlinear and inductive loads. The peak output current of the HIP1090 is self limiting in the 1A to 2A range to protect against short circuit conditions. Sustained high peak current may increase the junction tem- perature to 1 50°C and cause thermal shutdown. When this happens, the output current will fall off briefly before recover- ing, unless the over-temperature condition is sustained. Internally, both input and output over-voltage conditions are sensed to protect the circuit, making the high levels of tran- sient voltage ratings possible. Sustained voltage ratings of ±24VDC with transient ratings to ±90V allow a wide variety of applications in high stress environments. Except for the V CE SAT detector circuit, the HIP1090 is a higher current version of the CA3273 high side driver, which turns-on without the delayed step on the leading edge of the output pulse; switching with a typical T n time of ~0.5us. The CA3273 has a higher transient suppression threshold. 60 ! *> f 40 i C 30 ■ O 20 E g 1 10 ._ 7 _... T A = +25°C n V LOAD CON = C ND S 10 15 20 V, N SUPPLY VOLTAGE (V) FIGURE 5. CONTROL (QUIESCENT) CURRENT CHARACTER- ISTIC WITH LOAD 1 T T A = +25°C V :on = G' ID '1 5 10 15 V, N SUPPLY VOLTAGE (V) FIGURE 6. CONTROL (QUIESCENT) CURRENT CHARACTER- ISTIC WITH NO LOAD J 0.5 1.0 LOAD CURRENT (A) FIGURE 7. SATURATION (V, N - V 0UT ) CHARACTERISTIC 9-20 HIP 1090 Packaging TERM. 4 Lead No. 1 • Gate Lead No. 2 - Collector Lead No. 3 - Emitter Mounting Flange - Collector TO-220AB 3 LEAD JEDEC TO-220AB PLASTIC PACKAGE INCHES MILLIMETERS SYMBOL MIN MAX MIN MAX NOTES A 0.170 0.180 4.32 4.57 A, 0.048 0.052 1.22 1.32 b 0.030 0.034 0.77 0.86 3,4 b, 0.045 0.055 1.15 1.39 2,3 c 0.014 0.019 0.36 0.48 2, 3.4 D 0.590 0.610 14.99 15.49 - D, 0.160 4.06 E 0.395 0.410 10.04 10.41 - E, 0.030 0.76 e 0.100 TYP 2.54 TYP 5 e i 0.200 BSC 5.08 BSC 5 Hi 0.235 0.255 5.97 6.47 Jl 0.100 0.110 2.54 2.79 6 L 0.530 0.550 13.47 13.97 Li 0.130 0.150 3.31 3.81 2 0P 0.149 0.153 3.79 3.88 Q 0.102 0.112 2.60 2.84 NOTES: 1 . These dimensions are within allowable dimensions of Rev. J of JEDEC TO-220AB outline dated 3-24-87. 2. Lead dimension and finish uncontrolled in L, . 3. Lead dimension (without solder). 4. Add typically 0.002 inches (0.05mm) for solder coating. 5. Position of lead to be measured 0.250 inches (6.35mm) from bot- tom of dimension D. 6. Position of lead to be measured 0.1 00 inches (2.54mm) from bot- tom of dimension D. 7. Controlling dimension: Inch. 8. Revision 1 dated 1-93. Q Z UJ O z Q: 9-21 TVS SUPPRESSION - TELECOMMUNICATIONS SYSTEMS PAGE SUPPRESSION - TELECOMMUNICATIONS SYSTEMS 10-3 Introduction 10-3 System Transients 10-3 Lightning - Induced Transients 10-3 Calculations of Cable Transients 10-4 Power System-Induced Transients 10-5 Protectors - Voltage Transient Suppressors 10-5 Power Line Transients 10-7 , Relay Contact Protection 10-7 Surgector ™ Transient Surge Suppressor 10-7 Surgector Operation 10-8 Surgector Types 10-8 Performance Characteristics 10-9 Nomenclature, Packages, and Shipping 10-10 Applications 10-11 S 10-13 8 UJ CO _ i 2 u hi li a. to S CO 10-1 Suppression - Telecommunications Systems Introduction Modern telecommunication systems are fast, efficient, and complex. Many improvements have been made in central office equipment and subscriber equipment which involves the use of solid state circuitry. Unfortunately, solid state devices are much more susceptible to malfunction or failure due to transient voltages and noise than are older devices, such as relays, coils, step-switches, and vacuum tubes. To complicate matters further, increased usage of telecommuni- cation lines for data and video transmissions has produced a further intolerance for transient voltages. Although telecommunications systems have always employed transient protection devices such as the carbon gap, the gas tube, and the heat coil, these are not always adequate to protect solid state circuitry. Harris offers two dis- tinct technologies to deal with the varied requirements of telecommunications transient protection. The MOV, Metal Oxide Varistor, is a Zinc oxide ceramic based technology, and the SURGECTOR, a solid state silicon based process, which integrates a zener diode and the SCR technology on a single chip. The requirements of the telecommunications industry are varied and unique. Both technologies have advantages and limitations dependent on the specific application. The trade- offs are discussed in the Applications s System Transients A telecommunication system is made up of subscriber stations linked together through the cable plant and a central office switching network. Included in the system are repeater amplifiers, multiplexers, and other electronic circuits. Supplying the electrical energy to run the system is a main power source. The cable plant and the power supply provide a path by which damaging transients enter the system, to be transmitted to vulnerable electronic circuitry. The cable plant consists of con- ductors in shielded cables, which are suspended on poles (shared with power lines) or buried in the earth. A single cable is made up of many conductors, arranged in twisted pairs (tip and ring). Some sections of open-wire transmission lines are still used, but most of these are remote from central offices, and transient protectors are usually provided where the open wire enters the shielded cables. All of these cables (even the ones underground) are capable of picking up transient energy from lightning and conducting them to the central office or subscriber equipment. The power used by a telecommunication system is usually obtained from commercial power lines. These lines, like the telephone cables, are either suspended on poles or buried. Transient energy is frequently picked up by power lines and transmitted to the central office by direct conduction or by induction into the telephone cable plant. The increased use of off-line power supplies in telephone equipment makes power line transients even more hazardous to the electronic circuitry. Lightning - Induced Transients Lightning is the most common source of over voltage in communication systems. Because of the exposure to light- ning strokes, a knowledge of the effects of lightning is impor- tant when designing a transient protective system. Lightning currents may enter the conductive shield of a sus- pended cable by direct or indirect stroke, or it may enter a cable buried in the ground by ground currents, as shown in Figure 1 . In the case of a suspended cable, the lightning current that enters the cable is seeking a ground and will travel in both directions along the cable. Some of the current will leave the shield at each grounded pole along its path. Studies have shown that all of the lightning current has left the cable shield after passing 10 poles grounded in high conductivity soils or 20 poles grounded in high resistivity soil. 7/777 W 7777777 ^^ J V SHIELD -*- FIGURE 1. LIGHTNING CURRENT IN BURIED CABLE Y///// //// / / // ///A SHIELD ► I V / /////// / /// / //// INSULATING JACKET SHIELD VOLTAGE DISTANCE FIGURE 2. CONDITION FOR PUNCTURE OF CABLE JACKET Stroke currents leave a buried cable in a similar way but with a different mechanism. Since the cable shield has a finite electrical resistance, the current passing through it will pro- duce a potential gradient along its length. This voltage will produce a potential difference between the cable and the soil, as shown in Figure 2. At some point (Point A) the shield-to-earth potential will exceed the dielectric strength of the jacket, causing it to puncture. Some of the lightning current then flows through the puncture into the soil, thus equalizing the potential at that point. The remaining current continues along the shield until another puncture occurs, providing another path to ground. Suppression - Telecommunications Systems Lightning currents are usually not harmful to the shield itself, but they do induce surge voltages on the conductors of the cable which are often harmful to central office equipment. The surge voltage that appears at the ends of the cable depends upon the distance to the disturbance, the type of cable, the shield material, and its thickness and insulation, as well as the amplitude and waveshape of the lightning current in the shield. Since the current-derived potential along the cable shield is capacitively coupled to the cabled conductors, the waveshape of the surge voltage on the conductors will closely resemble the waveshape of the lightning current. Quantitative information on lightning has been accumulated from many sources,' 2 ' with research centers in the United States, Western Europe and South Africa. One of the most comprehensive surveys of available data has been compiled by Cianos and Pierce,' 3 ' describing the amplitude, rate-of- rise, duration, etc., in statistical terms. Using these statistics, one can make numerical calculations of induced voltages in various electrical circuits, such as the cable plant of a communication system. The parameters of interest are the voltages developed as a function of intensity and duration of the lightning impulse. The examples discussed later in this Sec- tion are based on this source of information. Calculations of Cable Transients The voltage surge induced into the conductors of a cable will propagate as a traveling wave in both directions along the cable from the region of induction. The cable acts as a trans- mission line. The surge current and voltage are related to each other by Ohm's law where the ratio of voltage to cur- rent is the surge impedance (Z ) of the cable. Z can also be expressed in terms of the inductance (L) and capacitance (C) per unit length of the cable by the equation, Z = VL7C(Q) 20 o| | | I 25 50 75 100 TIME (us) FIGURE 3. SEVERE LIGHTNING CURRENT WAVEFORM (2/50ms) < 355 284 213 142 71 10 20 30 40 50 TIME (ms) FIGURE 4. AVAILABLE CURRENT 2.75 MILES FROM 100kA LIGHTNING STROKE The velocity of the surge, as it propagates along the conduc- tors, is also a function of L and C, and can be expressed as: Velocity = ^1/(LC) (meters/sec) The series resistance of the shield and conductors, as well as losses due to corona and arcing, determine the energy lost as the disturbance propagates along the cable. Tests conducted on telephone cables' 4 ' have measured surge impedances of 80ft between any of the conductors and the shield. Shield resistances between 5ft and 6ft per mile were found to be typical. These values and the applied lightning current waveform of Figure 3 were used to compute the worst case transient which would appear at cable termi- nals in a central office. The computation assumes the light- ning current is introduced into a suspended cable shield at a point 2.75 miles from the central office. An average cable span between poles of 165 feet, with a ground connection on every fourth pole, was assumed. It was also assumed that the cable will support the voltage without arcing over. 10 20 30 40 50 TIME ( M s) FIGURE 5. OPEN CIRCUIT VOLTAGE 2.75 MILES FROM 100kA LIGHTNING STROKE The resulting short-circuit current available at the central office is shown in Figure 4. 10-4 Suppression - Telecommunications Systems The open-circuit voltage at the cable end is shown in Figure 5. This analysis shows that if a severe, 100kA lightning flash strikes a cable at a point 2.75 miles from a central office, a voltage transient reaching a peak of nearly 1 8kV may appear at the cable end, with about 355A of current available. Since the cable can be considered to be a linear system, the voltages and currents will bear a linear relation to the lightning stroke amplitude. A tabulation of the open-circuit voltage and available current which would result from stroke currents of various magnitudes is given in Table 5. Included in the table is the probability of occurrence, as given by Cianos and Pierce.' ' It should be realized that voltages in excess of 10kV probably would not be sustained since the cable insulation will break down. The transient voltage at the central office in any case would be excessive, so that protectors would be required. The pro- tector would conduct up to 21 3A surge current for most (85%) of the strokes that occur and only up to twice that cur- rent on rare occasions. The values shown in Table 1 are based on the assumption of a single conductor cable with the stroke point 2.75 miles from the central station. For closer strokes the peak short- circuit current at the cable end will increase as shown in Table 2. These calculations were made assuming a break- down at the stroke point, which gives the worst case result. TABLE 1. LIGHTNING TRANSIENTS AT CABLE END 2.75 MILES FROM STROKE POINT PEAK CURRENT PROBABILITY OF OCCURRENCE TERMINAL OPEN CIRCUIT VOLTAGE TERMINAL SHORT- CIRCUIT CURRENT OA) (%) (PEAK V) (PEAK A) 175 1 32,200 621 100 5 18,400 355 60 15 11,040 213 20 50 3,680 71 Since telephone cables actually have many pairs of wires rather than a single conductor, the peak currents in each wire will be lower. It is assumed that the stroke voltage will be induced equally in all wires if they are equally loaded. Then, the currents in all wires will be equal if all protectors are identical. To predict the individual wire currents, it is assumed that the wire currents are proportional to sheath current and the ratio of resistances, and are reduced a con- stant amount by cable inductance. Worst case calculated values for the shortest distances are shown in Table 2. An example of the current which a protective device must handle can now be estimated. Assume a cable of six pairs (the smallest available) is struck by lightning, inducing a stroke current of 100kA into the shield, at a distance of 0.25 mile from the protector. The transient current will be divided up among the twelve suppressors at the cable ends. Each protective device must handle up to 852A of peak current in order to clamp the voltage to a protected level. TABLE 2. PEAK LIGHTNING-INDUCED CURRENTS IN VARIOUS LENGTHS OF TELEPHONE CABLE (100kA LIGHTNING STROKE) DISTANCE TO STROKE (MILES) PEAK CURRENTS (A) AT STROKE POINT AT CENTRAL OFFICE SINGLE CONDUCTOR 6 PAIR CABLE 12 PAIR CABLE 2.75 630 355 1.50 630 637 1.00 734 799 0.50 1110 1120 712 453 0.25 1480 1480 852 463 Power System-Induced Transients Since telephone cables very often share a pole and ground wire with the commercial AC utility power system, the high currents that accompany power system faults can induce over-voltages in the telephone cables. These induced over- voltages will be at the power system frequency and can have long duration (compared to the lightning-induced tran- sients) from a few milliseconds to several cycles of power frequency. Three types of over-voltage can occur in conjunc- tion with power system faults: Power Contact - (Sometimes called "power cross"). The power lines fall and make contact with the telephone cable. Power Induction - The electromagnetic coupling between the power system experiencing a heavy fault and the tele- phone cable produces an over-voltage in the cable. Ground Potential Rise - The heavy ground currents of power system faults flow in the common ground connections and cause substantial differences in potential. There is little definitive data available on the severity of these over-voltages. However, proposals have been made by telephone protection engineers to define the power con- tact as the most severe condition. The proposed require- ment calls for the suppressor to withstand 10A RMS for a duration of power contact ranging from 10 to 60 cycles of the power system frequency. Protectors - Voltage Transient Suppressors Primary Protection The oldest and most commonly used primary protector for a telephone system is the carbon block spark gap. The device is made up of two carbon block electrodes separated by a small air gap of between 0.003 and 0.004 inch. One electrode is con- nected to the telephone cable conductor and the other to the system ground. When an over-voltage transient appears, the gap breaks down diverting the transient and dissipating the energy in the arc and the source impedance of the transient. Suppression - Telecommunications Systems The carbon gap is a low-cost protector but suffers from a rela- tively short life and exhibits sparkover voltage variations. Nominal 3-mil carbon gaps statistically sparkover as low as 300V and as high as 1000V. This is a serious problem. Telephone conductors occur in pairs in a cable so that tran- sient voltages induced into the conductors will be common to both tip and ring conductors, as shown in Figure 6. This longi- tudinal voltage produces no current through the load termina- tion. Normally, there is zero difference in the potential between conductors. If protector, PR, should breakdown at 400V, while PR 2 requires 700V to break down, then only PR, would breakdown on transient of 600V causing a transient current flow through the load. Even if PR 2 does break down but responds later in time than PR, a transient current will flow. TIP RESISTOR OR FUSE OPTIONAL -CD -GO- INDUCED LONGITUDINAL VOLTAGE IN CONDUCTOR PAIR -Wv FIGURE 6. UNBALANCED LINE PROTECTION Another common suppressor in telephone systems is the gas tube protector. It consists of two metallic gaps spaced by a distance of 0.010 to 0.015 inch. The electrodes are enclosed in a sealed glass envelope containing a combination of gases at a low pressure. Such gaps offer higher current-carrying capability and longer life than do carbon block devices. How- ever, the possibility of seal leakage and the consequent loss of protection has limited the use of these devices. Dual-gap gas tubes, also called three-electrode gas tubes, have been introduced to alleviate the problem of unbalanced breakdown as described in the preceding paragraph. Harris Varistors have properties that make them excellent candidates for telephone system protectors. These charac- teristics include tight tolerance, high reliability, high energy capability, and good clamping characteristics. The V130LA20A Harris Varistor, for instance, is capable of han- dling a peak transient current of 6500A (8/20|js pulse) and dissipating up to 703 of energy. The 6500A current surge would result in the voltage across the varistor being clamped at a maximum of 600V. A 1000A pulse would be clamped to less than 420V, yet ring voltage peaks of 1 80V would not be affected by this varistor. W 9 RING o Wv 4 -Wv FIGURE 7. VARISTOR CONNECTION BETWEEN TIP AND RING Varistors are often used in telecommunication circuits between tip, ring and ground requiring 1, 2 or sometimes 3 separate varistors. See Figure 7. The voltage rating of the varistor is determined by the volt- age applied between tip and ring. Most telecommunication systems have 52.5V DC with a superimposed ring voltage between 40V to 150V RMS (210V peak), which results in a minimum voltage rating for the varistor of 52.5V + 210V = 262.5V. The proper device would have a minimum DC-volt- age rating of greater than 262.5V. For example, a V230LA20A, two V130LA10A devices in series, or two V130LA20A devices in series would be appropriate. Secondary Protection Modern solid state communications circuitry can be dam- aged even if the primary protection is working normally. It is often advisable to provide a secondary protection system to further reduce the voltage transient. As shown in Figure 8, the secondary protection removes the over-voltage spike which is passed by the primary protector. 10-6 Suppression - Telecommunications Systems RESPONSE TIME OF PRIMARY PROTECTION J PRIMARY ( 9 ) PROTECTOR V=i/' HARRIS VARISTOR SECONDARY PROTECTOR i FIGURE 8. SECONDARY PROTECTION In most installations the length of conductor between the pri- mary protector and the telephone circuit boards is greater than 25 feet. The impedance (Z L2 ) presented by this length of wire to most lightning-induced transient voltages will insure that the primary protector will operate first and the secondary protector will not be exposed to the full surge. In the rare cases where a power cross occurs, the varistor may fail, but it will still perform its assigned task of protecting the circuit board. Because its failure mode is a short circuit it will blow the system fuses. Usually the probability of a power cross if so low that the replacement of a damaged varistor is an accept- able alternative to repairing a damaged circuit board. The SURGECTOR can also be a desirable transient protector for secondary protection. Its "crowbar" action and fast response time can shunt the transient to ground effectively and prevent damage to the system. The characteristics and forms of SURGECTORS are discussed in this section, "Surgector™ Transient Surge Supressor", and Section 8. Power Line Transients For transients introduced into a telecommunications system through the powerlines, the Harris Varistor is a very effective suppressor. Properly selected, the varistor will not effect the normal operation of the line but will clamp heavy transient surges to an acceptable voltage level. Refer to Sections 2, 4, and 6 for information on the selection of a varistor suppressor. Relay Contact Protection Even the most modern telephone equipment requires the use of relays and other electromechanical switching devices These devices are required to switch currents into inductive loads causing contact arcing, pitting, and noise generation. The Harris Varistor is a useful suppressor for increasing con- tact life, improving reliability, and reducing noise. Sections 1 and 6 contain selection information for contact protection applications by means of varistors. Surgector™ Transient Surge Suppressor The Harris SURGECTOR is a new type of surge-suppressor, developed to protect sophisticated electronic circuits from rapid, high-voltage power surges that conventional surge suppressors cannot handle. The need for a new type of surge suppressor stems from the increasing sophistication of today's electronics. In the telecommunications industry, for example, the trend is toward increasing use of medium- scale integrated (MSI) and very large-scale integrated (VLSI) circuits. These circuits are used in equipment that transmits, processes, codes, switches, stores data, and has multifunction capability, but is intolerant of voltage overloads. In addition, a strong shunt device, such as the SURGEC- TOR, is used to open a series device, such as a fuse, to pre- vent excessive current overloads of premise wiring and equipment as required by safety agencies (e.g., Underwrit- ers Laboratories). The SURGECTOR is a monolithic device. It consists of an SCR-type thyristor whose gate region contains a special dif- fused section that acts as a zener (avalanche) diode. The zener portion of the SURGECTOR provides continuous pro- tection of the circuit. Because it combines the continuous voltage protection of the zener with the thyristor's ability to handle high current, the SURGECTOR provides instantaneous protection against fast-rising, high-voltage pulses, pulses that are too rapid or too powerful for conventional devices (such as gas tubes, air-gap carbon blocks, or stand-alone, zeners) to block. As a result, the SURGECTOR can provide the much-needed sec- ondary surge protection for telecommunications circuitry, data links, and other sensitive electronic circuits that are especially susceptible to damage from transient voltage. Surge Characteristics • Large voltage and energy variations • Wide variations in surge durations • Possible rapid repetition and mixed polarity of surges • dv/dt of up to 1 0,000 V/us SURGECTOR Characteristics • High input impedance until breakdown (i.e. low leakage) • Repeatable breakdown/threshold voltage • High surge current handling capability • Withstand and respond to rapidly reoccurring surges • Last recovery to high impedance state (turn-off) • Dual polarity protection • No degradation of essential characteristics with use CATHODE ANODE P ZENER p ■ FIGURE 9. SURGECTOR VERTICAL STRUCTURE 10-7 - SURGECTORs Provide Transient Protection for: Central Office Equipment Supervisory Equipment Switchgear Equipment Data Transmission Handsets EPABX, PABX, PBX Repeaters Line Concentrator Receivers Headsets Modem PCM Surgector Operation The SURGECTOR allows normal operation of the circuit as long as the voltage does not exceed a certain maximum value (VDM). Current SURGECTOR devices are rated at 30V, 60V, 100V, 230V, and 270V. When a transient pulse hits the line, voltage begins to rise - often as an extremely rapid rate. Lightning, for example, can cause a voltage rise in excess of 1000V per microsecond. As soon as the voltage reaches the avalanche breakdown voltage, the zener instantly clamps the voltage. The voltage can rise above its normal value for the circuit, but only by a small amount; the SURGECTOR ensures that the protected circuit never sees a voltage greater than 110 percent of the zener avalanche operating voltage. A normal stand alone zener diode maintains a constant volt- age for the duration of the pulse and can quickly burn out from this energy overload. But in the SURGECTOR, current flows from the zener region into the thyristor gate, switching on the thyristor in nanoseconds. The thyristor drops to low voltage, creating a low impedance in the circuit, and shunts the excess energy from the circuit to the ground. In effect, the thyristor draws energy away from the zener, allowing it to survive the transient. Because of this, the SURGECTOR can handle about ten times more current than a stand alone zener. While the transient is on the line, the SURGECTOR remains in the ON state, and the voltage across the circuit is low. Its precise value depends on the type of pulse and the type of SURGECTOR being used. Eventually, the pulse passes, and the current begins to drop. When it reaches a certain minimum value, known as the "holding current," the SURGECTOR automatically shuts off, and normal circuit operation resumes, with the zener section of the SURGEC- TOR again providing continuous protection. DM 4/ tit t — — — T VBO v v M FIGURE 10. TYPICAL VOLT-AMPERE CHARACTERISTICS 200 1.5K V/ M s INDUSTRY STANDARD / LIGHTNING STROKE - / / / * 150A / ^-^DEVICE CURRENT DUE TO LIGHTNING SURGE 250 200 £ S 150 * 100 50 0.25 0.5 0.75 1 1.25 SECONDS (n) 1.5 1.75 2 FIGURE 11. INDUSTRY STANDARD LIGHTNING STROKE Surgector Types Harris SURGECTOR devices include SCR types, unidirec- tional and bidirectional. The SCR SURGECTOR is unidirec- tional but provides three terminals instead of two. The third terminal gives the user direct access to the 5CR gate region, so that the SURGECTOR types are available; the SGT10S10 (100V, 100mA), the SGT27S10 (270V, 100mA), and the SGT27S23 (270V, 230mA). With the external gate control circuitry, any voltage between 5V and 100V or 5V and 270V respectively can trigger the device. This class has high holding current (100 to 270mA) to allow rapid transition to the OFF state. The unidirectional SURGECTOR is available in voltages of 30V, 60V, and 230V (types SGT03U13, 2CT06U13, and 2GT23U13 respectively), the holding current is 130mA. The bidirectional SURGECTOR is capable of handling both positive and negative surges. It has two terminals, and only one SURGECTOR per line is required. Four versions are available at the present time; 230V and 270V, 1 30mA, surge capability of 10 x 1000|is at 100A, and two larger devices rated at 230V and 270V respectively with 270mA holding cur- rents and 200A surge capability at a pulse of 1 x 1 0OOus. 10-8 Suppression - Telecommunications Systems Performance Characteristics SURGECTOR devices have ratings for transient peak surge current of 300 to 600A for a 1 x 2us pulse and appropriately scaled currents at 8 x 20, 10 x 560, and 10 x 1000us. These rated surges can be applied to the SURGECTOR devices repeatedly without degradation. The overshoot ratio of the SURGECTOR is the ratio of the highest voltage encountered by the protected circuit (during a 100V/us pulse) over the zener voltage of the SURGECTOR. The SURGECTOR has the lowest overshoot ratio of any surge-suppression technol- ogy on the market today, which means it suppresses tran- sient voltage more effectively than gas tubes, metal oxide semiconductor devices, or carbon blocks. Many surge-suppression devices are characterized by the speed at which they switch on. A gas discharge tube, in which gas must ionize before the device can function, takes microseconds to become operational. But this specification is meaningless for the SURGECTOR, because the SURGECTOR provides instantaneous and continuous pro- tection. The zener section of the SURGECTOR always clamps voltage when the value reaches a certain minimum zener voltage for which the device is rated. The SURGECTOR type SGT23U13, which is rated at 230V, clamps the transient voltage the instant it reaches the zener voltage. Within nanoseconds, the thyristor switches on and drops the voltage to just a few volts. (The voltage will remain at this low value until the surge passes and the current drops below the holding current.) As stated, the SURGECTOR can handle peak currents up to 600A, depending on the type of pulse. But, like any solid- state device, the SURGECTOR will eventually fail if pushed beyond its specifications. However, the SURGECTOR is designed not to fail to an open condition on a 1 x 2 pulse below 450A (900A for the 5GT27B27). This becomes espe- cially important in new telecom equipment designs which are required to meet UL-1459 requirements. A typical design for secondary protection would use a pair of fuses and SURGECTOR devices to open the line on excessive cur- rents such as a power line cross. This is an important feature, especially in telecommunication applications. If a device fails to an open condition, the circuit remains unprotected until the device is replaced, and open failures on the line are not easily detected. A short, on the other hand, provides continuous protection against surges (although if prevents operation of the circuit) and is easy to Aside from failure due to operating beyond the device's specifications, the SURGECTOR has no inherent wearout mechanism. Performance is consistent and does not degrade with repeated use or time. There is no inherent limit on the SURGECTOR device's operating life. We predict the SURGECTOR will have a life comparable to Harris Power transistors, lasting 20 years or more. By comparison, gas tubes and carbon blocks have wearout mechanisms and trigger voltage changes. 1300 2.0 10.0 1000 TIME ( M s) FIGURE 12. SURGECTOR DEVICES CLIP VOLTAGE SURGES AND SHUNT ENERGY TO GROUND l T (INITIAL) = 2A 250 | 1 1 1 1 1 1 1 , 1 , 1 1 , 100 I 1 1 1 1 1 1 1 1 1 1 1 1 1 -40 -30 -20 -10 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (°C) FIGURE 13. TYPICAL HOLDING CURRENT vs TEMPERATURE SURGECTOR devices are usually used in conjunction with primary protection devices, and therefore should rarely see currents exceeding their rated capacities. When operated within their specifications, SURGECTOR devices automati- cally switch to their off-state once the pulse passes and the current drops below the holding current. The holding current of the SURGECTOR must he greater than the normally available short-circuit current in the circuit to insure that the SURGECTOR will return to the off-state when the transient has passed and allow normal circuit operation to resume. SURGECTOR devices are designed with high holding cur- rents, ranging from 100 to 270mA, depending on the type. These ratings are sufficient to allow proper operation in most telecommunications circuits. The SURGECTOR device's normal off condition is a state of high impedance, which prevents loading of the line. Leak- age is extremely low; the SURGECTOR passes less than 100nA. The capacitance of SURGECTOR devices is also low, presenting about 100pF for a bidirectional device in nor- mal telecommunication circuits. This is low enough to allow high-speed data communications. 1 0-9 Suppression - Telecommunications Systems Nomenclature, Packages, and Shipping The SURGECTOR type numbers are easy to interpret. The first three characters - the letter "SGT" - stand for SURGECTOR. Next comes two digits, which represent the maximum off-state voltage divided by 10. Following the voltage is a letter indicating either SCR (S), Unidirectional (U), or Bidirectional (B). The next two digits indicate holding current in milliamps divided by 10. All versions of the SURGECTOR are housed in a modified TO-202 versatab plastic package. This is a single-in-line package, meaning that all leads come out of the same end and are parallel to one another. The advantage of single-in-line packaging is that it makes the SURGECTOR easy to insert into a circuit board or socket by automated methods. Surgector Packages MODIFIED TO-202 PACKAGE STYLE PACKAGE A PACKAGE B SURGECTOR devices are shipped to the customer either in bulk or on plastic "sticks" designed for automated machinery handling. The sticks are rectangular tubes that hold 50 SURGECTOR devices each. PART NUMBER FUNCTION V z MIN (V) V B0 MAX (100V/I1S) !tsm (1 x 2 M s) 'tsm (10 x 1000ns) ■h (mA) PACKAGE STYLE SGT10S10 (Note 1) VAR Clamp 100 Note 1 300 100 > 100 A SGT27S10 (Note 1) VAR Clamp 270 Note 1 300 100 > 100 A SGT27S23 (Note 1 ) VAR Clamp 270 Note 1 300 100 > 230 A SGT03U13 Unidirectional 30 < 50 300 100 > 130 B SGT06U13 Unidirectional 60 <85 300 100 > 130 B SGT23U13 Unidirectional 230 <275 300 100 > 130 B SGT21B13 Bidirectional 210 270 300 100 >130 B SGT21B13A Bidirectional 210 290 300 100 >130 B SGT22B13 Bidirectional 220 280 300 100 >130 B SGT22B13A Bidirectional 220 290 300 100 >130 B SGT23B13 Bidirectional 230 290 300 100 >130 B SGT23B13A Bidirectional 230 315 300 100 >130 B SGT27B13 Bidirectional 270 345 300 100 >130 B SGT27B13A Bidirectional 270 360 300 100 >130 B SGT27B13B Bidirectional 270 375 300 100 >130 B SGT27B27 Bidirectional 270 345 600 200 >270 B SGT27B27A Bidirectional 270 360 600 200 >270 B SGT27B27B Bidirectional 270 375 600 200 >270 B NOTES: 1 . Dependent on trigger circuit. 2. All surgectors supplied in modified JEDEC TO-202 Package. Package Style A = 3 lead version Package Style B = 2 lead version 3. All devices UL recognized to 497B - File Number E1 35010. Holding current in milliamps divided by 10 Type of SURGECTOR: U = Unidirectional B = Bidirectional S = SCR _ Off-State Voltage Rating divided by 10 I— SURGECTOR 10-10 Suppression - Telecommunications Systems FIGURE 15. FULL BALANCED PROTECTION EMPLOYING THREE UNIDIRECTIONAL SURGECTOR DEVICES AND THREE DIODES Applications Telecommunications equipment has to operate in extreme transient/surge environments. Transients may originate from power mains, switching sources, lightning and electrostatic discharges. Isolation, grounding, and shielding among others, are methods used to control transients but while these tech- niques may be used in various telecom applications they are not totally effective. The Harris line of SURGECTOR devices protects circuits from damage better than Transorb® zeners, gas-discharge tubes, spark-gaps and any other means of protection. SURGECTOR devices offer continuous protection with unique ability to clamp at specific voltages (30V, 60V, 100V, 230V or 270V) which then trigger the SCR on and bypass the energy away from the circuit. The Harris SURGECTOR may be used in many applications to provide transient energy protection at subscriber stations and central offices where other suppres- sion devices do not provide adequate protection for newer more sensitive circuit components. The SURGECTOR com- bines the protection of crowbar-acting devices and fast volt- age-clamping devices. They combine the clamping voltage temperature coefficient and low clamping-voltage ratio of a zener diode with the high current surge capability of a spark gap (gas-discharge tube) device. Bidirectional devices pro- vide this protection in either polarity as in the case of the gas- discharge tube. In order to protect equipment properly, the cir- cuit connected to the input lines must limit the energy deliv- ered through fault conditions on the phone lines. This energy must then be compared to the minimum safety standards of UL and the FCC to see if a proper design has been achieved for the range of expected transients and overvoltages. Note that UL requires AC testing, therefore "U" and "S" types are typically used with shunt or bridge rectifiers. For example the UL-1459 standard requires several overvoltages and currents to be imposed on telephone equipment - such that power lines coming in contact with telephone lines will not cause fires in the equipment or in the house wiring. One test involves a 1 .5s application of 600V at 40A. This voltage would certainly turn on a SURGECTOR, protecting the equipment for overvoltage. The resulting 40A current flow must then be interrupted or limited to a safe value. Using Ohm's Law, E = IR, it can be estimated that 15Q will limit 600V to 40A of current. This amounts to about 200 feet of 26 gauge telephone wire. Of course, additional resistance can be added to the telecom equipment to provide even more protection than the 600V, 40A requirement. In order to interrupt the current, a fuse may be employed that will open before either the wiring or the SURGECTOR is damaged. A fast acting 1A fuse will readily open the circuit within the time-current curve specified by UL-1459. (All other fuse parameters should be checked with the fuse manufac- turer before finalizing a design.) As a result of either lightning transients or the SURGECTOR turning on, a transient voltage of L times di/dt will appear in the system. Transformer and ringer inductance should be examined for its contribution to the overvoltage condition. In addition, the circuit wiring going to the SURGECTOR should be arranged so that this effect is minimized. TELEPHONE LINE PAIR FIGURE 16. TWO BIDIRECTIONALSURGECTOR DEVICES ARE PLACED BETWEEN THE TIP AND RING LINES JUST AFTER THESE LINES ENTER THE TELEPHONE TO PROTECT DELICATE TELECOMMUNICATIONS GND /1777~ -48V LINE INTEGRATED SLIC FIGURE 17. FULL BALANCED PROTECTION USING THREE TERMINAL SURGECTOR DEVICES Transorb® is a registered trademark of General Semiconductor Industries, Inc. 10-11 Suppression - Telecommunications Systems TABLE 3. TYPICAL TRANSIENT SURGE SUPPRESSOR APPLICATIONS SUPPRESSION DATA 1 IMPQ TELECOM /ppiMARV^ ^MIWIMM T } TELECOM ^FrnwnAPV SCUUHUJln T AC pnWFR 1 IMPQ rUVVCn LIINCo DC POWER AND MU 1 UmUl IVC Surgeclor X X X X MOV X X X X X Avalanche Diode X X X Gas Tube X TABLE 4. COMPARISON OF SURGE SUPPRESSION DEVICES TRANSIENT SURGE SUPPRESSION DEVICES MAJOR ADVANTAGES/USES MAJOR LIMITATIONS Surgector + Ideal for Datacom and Telecom + Leakage • <50nA + Shunt Capacitance - <50pF + Subnanosecond Response + Lifetime Unlimited at 200A, 8 x 20jis Pulse Shape + Failure Mode - Short Circuit - Cannot be Used in DC Circuits where Available Current Exceeds Holding Current - Surge Current Capability -200A at 8 x 20ns Pulse Shape - Limited AC Line Protection Capability Metal-Oxide Varistor (MOV) + Ideal for AC Power Lines; Suitable for Low- Voltage Logic Protection + Subnanosecond Response + Units Available up to 70.000A Surge + Lifetime at 1000A, 8 x 20|js Pulse Shape - 1000 Surges + Failure Mode - Short Circuit - Shunt Capacitance - >500pF - Leakage - Approximately 10(iA - Clamp Voltage Goes Up with Current Avalanche Diode + Ideal for Low-voltage Logic Protection + Subnanosecond Response + Lifetime at 50A, 8 x 20ns Pulse Shape - Unlimited + Shunt Capacitance - 50pF + Failure Mode - Short Circuit - Low-Surge Capability - 50A at 8 x 20ns Pulse Shape - Leakage - Approximately 1 0jiA - Clamp Voltage Goes Up with Current Gas Tube + Wide use in Telecom for Primary Protection + High Surge Capability - >20,000A + Leakage - Subpicoamps + Shunt Capacitance - <1 pF + Lifetime at 500A, 8 x 20ns Pulse Width - 200 Surges - Response time - <5\is - Failure Mode - Open Circuit - Follow-On Current Because of "Crowbar" - Trigger Voltage Changes with Time - Limited Life Whereas most telecom applications use either 230V or 270V SURGECTOR devices to accommodate the 100V ring signal plus battery voltage, there are also low voltage SURGECTOR applications for data cables, alarm systems, and control cables. These signals can be +12V, 24V AC, or 48V DC . For these applications the low voltage 30V and 60V unidirectional and variable voltage SCR type SURGECTOR types are suitable. Typical applications are shown in Figures 15 through 20. By using a few extra components these economical general purpose circuits become quite reliable. In some cases these circuits can be simplified to obtain a lower parts count. 10-12 Suppression - Telecommunications Systems LINES IN GND LINES OUT One Surgector recommended per each 4 lines. FIGURE 18. DATA LINE PROTECTOR I I i iu — Lvv» T H RING SGT10S10 FIGURE 20A. USING THE SCR TYPE SURGECTOR WITH -48V SGT10S10 FIGURE 20B. USING THE SCR TYPE SURGECTOR WITH References [1] Bennison, E., P. Forland and A.J. Ghazi, "Lightning Surges in Open-Wire, Coaxial and Paired Cables" IEEE International Conference on Communications, June 1972. [2] Golde, R.ll., "Lightning Currents and Related Parameters," Lightning, Vol. 1 , Physics of Lightning, Chapter 9, ed. R.H. Golde, Academic Press, 1977. [3] Cianos, N. and E.T. Pierce, "A Ground Lightning Environment for Engineering Usage," Report No. 1 , Stanford Research Institute, August 1972. [4] Boyce, C.F., "Protection of Telecommunication Systems," Lightning, Vol. 2, Lightning Protection, Chapter 25, ed. R.ll. Golde, Academic Press, 1977. [5] "Connection of Terminal Equipment to the Telephone Network," Federal Communications Commission Rules and Regulations, part 68, October 1982. FIGURE 19. TELECOM PROTECTOR 10-13 TVS SUPPRESSION - AUTOMOTIVE TRANSIENTS SUPPRESSION - AUTOMOTIVE TRANSIENTS Transient Environment Varistor Applications Protection by a Central Suppressor Protection of Electronic Ignition . . . PAGE 11-3 11-3 11-3 11-3 11-7 11-1 Suppression - Automotive Transients Transient Environment The designer of electronic circuits for automotive applica- tions must ensure reliable circuit operation in a severe tran- sient environment. The transients on the automobile power supply range from the severe, high energy, transients gener- ated by the alternator/regulator system to the low-level "noise" generated by the ignition system and various acces- sories (motors, radios, transceivers, etc.). Transients are also coupled to the input and output terminals of automotive electronics by magnetic and capacitive coupling in the wiring harness, as well as conductive coupling in common conduc- tor circuits (especially the chassis "ground"). Steady state overvoltages may be applied by the circuit power supply due to the voltage regulator failure or the use of 24V battery "jump" starts. The circuits must also be designed against the possibility of the battery being connected in reverse polarity. Figure 2 shows a simplified automotive electrical system, illustrating transient sources and how to protect against them. Circuits which drive inductive loads must be protected against the transients resulting from the energy stored in the field of the inductor. These transients can be defined from the load inductance and load current. Table 1 summarizes the automotive power supply transients as documented by the Society of Automotive Engineers (SAE).' 1 ' Achieving maximum transient protection involves many fac- tors. First, consequences of a failure should be determined. Current limiting impedances and noise immunity require- ments need to be considered. The state of the circuit during the transient (on, off, unknown) and the availability of low- cost components capable of withstanding the transient are other factors. Considerable variation has been noted in the data gathered on automotive transients. Further, the interac- tion of other parts of the automotive electrical system with the circuit under transient conditions may require definition. The empirical evaluation of transient suppression using SAE-recommended test circuits,' 2 ' is invaluable in many cases. Figure 1 illustrates the test waveform for the most common, high energy transients. Varistor At To illustrate the procedures involved in designing transient pro- tection for automotive electronics, two examples are provided. One example illustrates the protection of a solenoid driver cir- cuit consisting of a logic integrated circuit with power transistor buffer; the second is the protection of an ignition circuit output transistor. These examples also illustrate the difference between protecting against random and repetitive transients. For random transients, energy and clamping versus standby power dissipation are dominant constraints. For repetitive tran- sients, transient power dissipation places an additional con- straint on the choice of the suppression device. The solenoid driver protection circuit also illustrates the conflicting constraints placed on automotive transient suppressors by the low maxi- mum voltage ratings of integrated circuits, the 24V jump-start cycle and the load dump transients. SOURCE IMPEDANCE - 0.512 FIGURE 1 A. MUTUAL COUPLING TRANSIENT - TESTED IN BOTH POLARITIES, SERIES AND PARALLEL INJECTED VOLTS 80 ; 40 t<0 < t < 400 400 10J S125V Infrequent <0.32s Inductive Lo j Transient <1J -300V to +80V Often <0.20s Alternator Field Decay nition Pul <1J -100V to -40V Each Turn-Off 90ms Ignition Pulse, Battery Disconnected <0.5J <75V <500Hz Several Vehicle Life Mutual Coupling in Harness (Note) <1J <200V Often 15ns Ignition Pulse, Normal <0.001J 3V <500Hz Continuous Accessory Noise S1.5V 50Hz to 10kHz Transceiver Feedback = 20mV R.F. NOTE: H si to ^ 11-5 Suppression - Automotive Transients struct a representative example. The key fact is the alternator surge power available to be dissipated in the sup- pressor. Figure 3A is suggested as a starting point for analysis. Since a peak surge power of 1600W is available, a suppressor with a clamping voltage of 40V would draw a peak current of 40A. The surge energy rating needed for the suppressor can be found by taking the integral of the surge power over time, resulting in approximately 85J. A jump-start rating of 24V is also needed. Evaluating central suppressor devices can be simplified with the aid of a load dump simulator as shown in Figure 3B. The inductor L, which simulates the alternator inductance, slows the surge rise time but does not materially affect the analysis. In the absence of a suppressor or load, the output waveform will be similar to that of Figure 1 B. If a suppressor is inserted, the oper- ating characteristics can be estimated as follows: Assume V c = 40V, then l P = (80 -40VJ/R., = 40A The energy W dissipated in the varistor may be estimated by: W = 1.4V c lpt (see Section 6 on Energy). The impulse dura- tion t, of the surge current (see Section 3, Figure 21) can be estimated from the delay time as: T = 0.7RC, where R is the series-parallel combination of the effective resistance of the varistor and simulator components and R 2 . To facilitate this calculation, assume that the effective resistance is given by V c /0.7 lp = 1 .4fi. The delay time con- stant with the suppressor in the circuit then becomes: RC- ' 2.4x7 ^2.4 + 7. (0.03)= 0.054s and the surge impulse duration: t = 0.7 RC, = 0.038s The deposited energy now can be estimated by: W = 1.4 V c l p T = (1.4)(40)(40)(.038) = 85J Hence, the simulator produces unprotected and protected circuit conditions similar to those expected in the vehicle itself. A suppressor with the needed high energy capability has been developed and already is in use. This improved Harris Varistor model V24ZA50 has a load dump rating of 1 00J. A narrow-tol- erance selection can satisfy the clamping requirement of 40V maximum at 40A, with a jumpstart rating of 24V. The protective performance of this suppressor can be measured conveniently using the simulator circuit shown in Figure 3B. The suppressor's durability has been demonstrated by sub- jecting test specimens first to 10 load dumps about 30s apart. After readout, additional stresses were applied consisting of a single dump of 200J and a jump-start overvoltage of 24V for five minutes. Clamping voltage, which is virtually invariant with tem- perature, was found to remain nearly unchanged by stress up to the single-surge destruction level of about 250J (see Figure 3C). Standby current, the most sensitive parameter, remained well within limits as shown in Figure 3D. -0.08 -.04 0.04 0.06 0.12 0.16 0.2 TIME (s) FIGURE 3A. ALTERNATOR POWER OUTPUT INTO A CENTRAL CHARGE TO 80V ^ C1 ^ 0.03F 1 -AAA- R 2 rysuppREssoR M UNDER /J TEST FIGURE 3B. LOAD DUMP SIMULATOR CIRCUIT (%) CLAMPING VOLTAGE CHANGE (% AT 20A) ■ N = 8 10 DUMPS 1 DUMP AT 100 J AT 200J S FIGURE 3C. STABILITY OF CLAMPING VOLTAGE STANDBY CURRENT AT 12V (mA) THRESHOLD OF THERMAL RUNWAY >100mA PROPOSED END-POINT QUALIFICATION 1 DUMP JUMP AT 200J START 24V FIGURE 3D. STABILITY OF STANDBY CURRENT 11-6 Suppression - Automotive Transients Protection of Electronic Ignition In the second example, the protection of the output power transistor in an electronic ignition circuit is analyzed. This power transistor performs the current switching function of mechanical distributor points in the usual Kettering ignition, thus avoiding the pitting, burning, and erosion mechanisms associated with the mechanical points. The ignition circuit is illustrated in Figure 4. resistor and a current gain over 20. The base emitter on- state voltage, V BE(0N) , is between 1 .0 and 1 .8V, and the col- lector to emitter saturation voltage is between 0.9 and 1 .5V. The varistor clamp voltage range is determined by the 200V needed to supply minimum spark voltage and the 400V rat- ing of the transistor. At 200V the varistor current must be less than: 1 v V BE(ON) /47 "=47Q= 002A DISTRIBUTOR SYSTEM CONDITION CONDITION v B START SWITCH Running 12V To 16V Open Starting 5VTo 12V Closed NOTE: 1. Operating temperature range -40°C to +110°C FIGURE 4. TYPICAL ELECTRONIC IGNITION CIRCUIT In normal operation, the coil primary current builds up when the power transistor is on, storing energy in the coil induc- tance. The power transistor is then switched off, and the volt- age at the collector rises rapidly as the capacitor, C, charges. Transformer action causes the secondary voltage to rise until the spark plug reaches firing voltage, clamping the transistor collector voltage at a safe value. If a spark plug is fouled or disconnected, the collector voltage can rise until either the capacitor contains the stored energy (minus losses), or the transistor breaks down with resulting dam- age/failure. Since the capacitor is small, transfer of the stored energy of the coil to the capacitor would result in a very high voltage requiring transistor protection. A varistor can be used to turn the transistor on during the period of high voltage, thus dissipating the excess energy safely as heat. The constraints on varistor selection are: clamp volt- age must be low enough to protect the transistor; clamp volt- age must be high enough to not affect normal spark energy; the power dissipation (with two spark plugs disconnected) must be within varistor ratings for an 8-cylinder, 4-cycle engine at 3300rpm (misfires at 55Hz, average). The mini- mum spark voltage output required is 20,000V, which repre- sents 200V at the transistor collector. The transistor has a breakdown voltage rating of 400V with the 47Q. base emitter to prevent unwanted transistor turn-on. The minimum varis- tor voltage at the 1 mA varistor specification point is found by solving the varistor voltage equation: I = kv a , assuming a maximum ce of 40. The result is 186V. The peak clamping current (at 400V-V BEMAX ) is found from the energy balance equation for the coil, using the peak coil current, \q. I c maximum is analyzed under both start and run conditions to determine the worst c ,12-0.9 C(slart) "^TssT and, . , 16-0.9 'c(run) - "T6£T 6.17A 4.2A The worst case coil current occurs with the start switch closed and will be less than 6.2A. The maximum peak coil current, l P when clamping is then: 1 1 .2 1, .2 1„ .,2 2 L 'c = 2 L 'p + 2 C V P and with a V P , of 400V: 2 2 2 lp = \ c - 400 C/L results in 6.0A starting and 3.6A running. The varistor cur- rents corresponding to this are: l p /h FE + V B£ /47n; which gives 0.34A starting and 0.22A running. Peak varistor voltage must be less than: 400V - V BE (i.e., 398V at 0.34A) The varistor power dissipation at 3300rpm (55pps), assum- ing a triangular current waveform with constant voltage and no losses, is found from coil energy balance: 1/2L (I P ) 2 = V MAX ^t solving for t: (7)(iO' 3 )h(3.6A) 400V 63ns The varistor power dissipation is found to be: v max? « = 398V (5f*) (63)( 10 - 6 )s (55pps) = 0.15W 11-7 i i , Suppression - Automotive Transients Observations indicate that the losses in the coil and reflected secondary load will reduce this by half to about 75mW. Using the 110°C ambient temperature derating factor of 0.53, it is found that a varistor of 0.1 5W dissipation capability is required. The varistor parameters are now defined as V x of at least 186V at 1mA but less than 398V at 0.34A and capable of at least 0.1 5W dissipation. The V220MA2A and V270MA4B both fit these requirements. As these examples have illustrated, the use of the Harris Varistor in automotive circuits for transient protection is both technically and economically sound. Design procedures are identical to the procedures used in the other environments. Experimental verification of the degree of protection can be made using standard waveforms reported by automotive engineering investigators. References [1 ] "Preliminary Recommended Environmental Practices for Electronic Equipment Design," Society of Automotive Engineers, 2 Pennsylvania Plaza, N.Y., N.Y. 10001. [2] "Electromagnetic Susceptibility Test Procedures for Vehicle Components (except Aircraft)," Society of Auto- motive Engineers, 2 Pennsylvania Plaza, N.Y., N.Y. 10001. [3] Korn, S.R., "Transient Voltage Suppression in Automo- tive Vehicles," SS-8766. 11-8 TVS APPLICATION NOTES APPLICATION AN8820.2 AN9108.2 AN9211 AN9304.3 AN9306 AN9307.1 AN9308.1 AN9310 AN9311.3 AN9312.2 PAGE Recommendations for Soldering Terminal Leads to MOV Varistor Discs 12-3 Harris Multilayer Surface Mount Surge Suppressors 12-5 Soldering Recommendations for Surface Mount Metal Oxide Varistors and Multilayer Transient Voltage Suppressors 12-15 ESD and Transient Protection Using the SP720 12-22 The New "C" III Series of Metal Oxide Varistors 12-32 The Connector Pin Varistor for Transient Voltage Protection in Connectors 12-37 Voltage Transients and Their Suppression 12-44 Surge Suppression Technologies Advantages and Disadvantages (MOVs, SADs, Gas Tubes, Filters and Transformers) 1 2-49 The ABCs of MOVs 12-55 Suppression of Transients in an Automotive Environment 12-58 O 7' & < ui O H □ ° a 2 a. < 12-1 Harris Semiconductor No. AN8820.2 April 1993 Harris MOVs Recommendations for Soldering Terminal Leads to MOV Varistor Discs Introduction The CA series of MOV varistor discs with silver electrodes are specifically designed for custom assembly and packag- ing. To take advantage of the excellent performance and reliability of Harris varistor technology, it is important that the correct materials and processes be used to solder on the terminal leads. Solder Fixtures Where varistor discs are custom assembled and packaged, fixturing is normally employed to maintain disc and terminal alignment during solder reflow. Soldering fixtures should be of lightweight design to reduce their thermal mass and, hence, the time necessary to bring them to reflow temperature. Disc and terminal lead should be pressed together lightly during the whole soldering process to help expel flux residues and excess solder from the interface. Trapped flux residue can result in bubbling of the solder, which leaves voids between silver electrode and terminal. Excess solder will enhance the tendency of the silver electrode to leach. Soldering Ovens Box, convection, and conveyor belt ovens are suitable for reflow solder processes using fixtures. Box ovens should have forced air circulation with sufficient ventilation to remove flux vapors. It is important that every fixture position in the oven be subjected to the same heating conditions. Therefore, fixture positions should be limited to locations within the oven where uniform airflow and temper- ature can be maintained. Convection ovens employ carefully designed exit baffles to facilitate close control of the soldering environment. Air is the best environment for soldering varistors. An inert gas (nitro- gen) or reducing atmosphere is sometimes employed to reduce oxidation in these ovens, but neither of these is rec- ommended for the processing of unpassivated varistors. A very repeatable temperature profile can be achieved with a conveyor belt oven. The profile is determined by the temper- ature of the heated zone(s) and the speed of the belt. A fixed loading pattern also helps in achieving uniform results. Fluxes Fluxes are used for chemical cleaning of disc and terminal surfaces. There are three basic types: R - These unactivated fluxes are less effective than the others in reducing oxides of copper, nickel, or palladium/silver metallizations, but are the ones rec- ommended for MOV varistors. All other fluxes increase leakage, reduce long term reliability, and can promote leaching of the silver electrode. Non- charring, non-activated R type fluxes such as Alpha 100 or its equivalent are best. RMA - These are mildly activated fluxes, and the most com- monly used in the mounting of electronic compo- nents. They may be used with varistors, but are not recommended. RA - These fully activated fluxes are corrosive, difficult to remove, and can lead to varistor failure. They must not be used to flux varistor discs. Solders and Solder Temperature Solders in the form of pastes or preforms can be used with varistors. Preforms are solder shapes premanufactured to specific sizes. Upon melting, they provide highly reproduci- ble volumes of solder for joining. Preforms can be prefluxed, eliminating the need for any additional fluxing. Heat should not be applied to a varistor too quickly, as the flux will not have sufficient time to activate and clean the join- ing surfaces. The result will be poor solderability. On the other hand, no varistor should be held longer than neces- sary at an elevated temperature. If heat is applied too slowly or maintained above reflow temperature for too long, leach- ing of the silver electrode into the solder will occur, reducing the disc to terminal bond strength. To avoid leaching, only solders with at least 2% silver content (e.g., 62Sn/36Pb/2Ag or equivalent) should be used; see Table 1 . It is equally important to observe processing time and temperature limits. Failure to do so can result in excessive leakage and alterations of the varistor's VI characteristic. Copyright © Harris Corporation 1993 Application Note 8820 Cleaning and Cleaning Fluids Cleaning is an important step in the soldering process, prevents electrical faults such as the high curre caused by ionic contamination, ab dirt films, and resins. A wide variety of cleaning processes can be applied to varis- tors, including water based, solvent based or a mixture of both, tailored to specific applications. Harris recommends 1.1.1 trichloroethane for the removal of flux residues after soldering. Defluxing in a solvent bath with ultrasonic agitation, followed by a solvent vapor wash, is a very effective cleaning process. After cleaning, the low boiling point solvent completely evap- orates from the disc, and will not harm solder joints. TABLE 1. SILVER BEARING SOLDERS (ALPHA METALS) ALLOY 62Sn/36Pb/2AG 96.5Sn/3.5Ag 96Sn/5 Ag 10Sn/88Pb/2Ag 5Sn/92.5Pb/2.5Ag 97.5Pb/2.5Ag MELTING TEMPERATURE 179°C 221 °C 221°C-245°C 268°C - 302°C 280°C 305°C 12-4 Harris Semiconductor NO. AN9108.2 March 1995 Harris Suppression Technology Harris Multilayer Surface Mount Surge Suppressors Author: Martin Corbett Introduction Sensitivity of Components Modern electronic circuits are much more vulnerable to dam- age from transient overstresses than earlier circuits, which made use of relays and vacuum tubes. The progress in the development of faster and denser integrated circuits has been accompanied by an increase in system vulnerability. As the use of such systems has increased so to has the need for their protection. Figure 1 shows damage susceptibility of some commonly used components, including discrete semi- conductors and integrated circuits P< 2 \ As many semiconductor devices can be damaged by poten- tial differences that exceed 10 volts, the survivability of mod- ern electronics is limited when exposed to transient overvoltages. The advent of smaller faster technologies, such as high speed logic and MOSFETs, has led to an increased vulnerability of electronic circuits to damage from overstresses. The voltage, current, or power seen by a device must be below the failure threshold of the device. The value of this threshold is a function of the magnitude and EMI duration of a transient overvoltage occurrence. The magni- tude of the transient is determined by the nature of the source, the characteristic impedance of the circuit and the resistance and inductance between the source of the tran- sient and the device. Integrated circuits are sensitive components, and their threshold for damage is difficult to increase. Therefore, tran- sient protection of these sensitive circuits is highly desirable to assure system survival. Digital integrated circuits produced with TTL technology are fairly rugged devices and are relatively insensitive to high speed transients. However, ICs designed with new technolo- gies, that have thinner gate oxides and higher cell densities, are more susceptible to voltage transients. When looking at the gate oxide cross section of devices using existing and new technologies, it is realized that the susceptibility to transients is continuously increasing due to the potential of damage with "punch-through". In order to EMP AND LIGHTNING • DIODES WAVE MIXER GP SIGNAL RECTIFIERS REFERENCE ZENER • TRANSISTORS LOW POWER HIGH POWER TTL DTL RTL ECL MOS LINEAR IC ■ BASIC COMPONENTS SCRS JFETS CAPACITORS 0.1 1 10 10* 10 3 10" 10 5 WATTS EMI - ELECTROMAGNETIC INTERFERENCE ESD - ELECTROSTATIC DISCHARGE EMP - ELECTROMAGNETIC PULSE FIGURE 1. RELATIVE DAMAGE SUSCEPTIBILITY OF ELECTRONIC COMPONENTS (FOR 1us PULSE) O P W < 111 O H j o a. z E < Copyright © Harris Corporation 1 995 12-5 Application Note 9108 work with these devices successfully, the sensitivity of such devices must be fully understood, and adequate precautions taken to ensure reliable operation, as well as survival in harsh environments. Table 1 shows a comparison of the fea- ture size, supply voltages, and typical gate count of various IC technologies. TABLE 1. CURRENT INTEGRATED CIRCUIT TECHNOLOGY PROPERTIES BIPOLAR MOS BiMOS POWER BiMOS Feature Size ( M M) 5.0 1.0 1.5 3.0 Typical Gate Count 500 6 16 80 Typical Supply Voltage (Volts) +60 +6 +16 +80 When designing to protect systems, it is desirable to ensure that worst cases stresses are below the failure threshold of the circuit. In the situation where information on the failure threshold is unknown, it is permissible to use a factor of 2 above the device/system steady state ratings and specify a brief duration at this over stress level (usually a few micro- seconds). Such an approach has been endorsed by the U.S. Department of Defense Military Handbook 419 [3] . When sensitive devices are specified in a circuit, transient protection must not be treated as an afterthought. If no transient suppressor is used, the weakest device absorbs most of the transient energy, with a high probability of a failure. If the failed device is replaced by one having higher breakdown ratings, the next weakest device will take over the unintended roll of transient suppressor, and system failure could still result. Simply replacing failed devices with higher capability parts does not guarantee system reliability. The Transient Threat Transients exist in every AC or DC system, or any wire con- necting two pieces of equipment or components. The sources of the transient can be lightning, nuclear electro- magnetic pulse, high energy switching and high voltage sparkover, or electrostatic discharge. These transients may be found wherever the energy stored in inductances, capac- itors, or mechanical devices, such as motors and genera- tors, is returned to a circuit. Stray capacitance and inductance may also set off oscillations, making the problem even worse. While a direct hit from lightning is not of real concern for a printed circuit board user, what may be of concern is the level of the transient which is "let through" by the primary suppressor. This "follow on current" may be up to 50A and it will last for a number of microseconds. If this current is above the failure threshold of a device in the circuit, it will be destroyed. Hopefully, the threat of transients generated from nuclear electromagnetic pulses (NEMP) will not be a real concern. However specific requirements do exist to ensure that sys- tems are protected from the fast rise pulses of NEMP. These transients have a rise time of approximately 5ns and are of a magnitude similar to that encountered from lightning. The two most likely types of transients from which a circuit must be protected are electrostatic discharge (ESD), and the switching of reactive loads. ESD will result when two conducting materials are brought close to one another and a voltage discharge occurs. The resulting voltage discharge can be as high as 25kV and will last up to 50ns. One of the most common methods of "zapping" circuits is walking across a carpeted floor, building up an electrical charge, and touching a device without being properly grounded. Transients can also be generated when an inductive load is disconnected and the existing energy is discharged back into the circuit. The arc generated from the opening of mechanical relay switches is another common source of switching transients. Whatever the cause of the transient, natural or man-made, the damage potential is real and cannot be casually dis- missed if reliable operation of equipment is to be expected. To properly select a transient suppressor, the frequency of occurrence of transients, the open-circuit voltage, the short circuit-current, and the source impedance of the circuit must be known. To date, designers have used resistors, capacitors, induc- tors, metal-oxide varistors, zener diodes, silicon carbide varistors, spark gaps, carbon blocks, or combinations of these to suppress transients and protect sensitive compo- nents. The new Harris series of Multilayer (ML) surge sup- pressors represents a unique and effective solution for transient suppression. 12-6 Application Note 9108 Multilayer Surge Suppressor Description The Harris multilayer (ML) series of transient voltage surge suppressors represents a recent breakthrough in the area of semiconducting ceramic processing. The ML suppressor is a compact, surface mountable chip that is voltage dependent, non-linear, and bi-directional. It has an electrical behavior similar to that of a back-to-back diode, i.e. it is inherently fully symmetrical, offering protection in both forward and reverse directions. The sharp, symmetrical breakdown characteris- tics of the device provides excellent protection from damag- ing voltage transients (Figure 2). When exposed to high voltage transients, the ML impedance changes many orders of magnitude from a near open circuit to a highly conductive FIGURE 2. SHARP SYMMETRICAL BREAKDOWN OF MULTI- LAYER SUPPRESSOR Construction The ML is constructed by forming a combination of alternat- ing electrode plates and semiconducting ceramic layers into a block. Each alternate layer of electrode is connected to opposite end terminations (Figure 3). The interdigitated block formation greatly enhances the available cross-sec- tional area for active conduction of transients. This paralleled arrangement of the inner electrode layers represents signifi- cantly more active surface area than the small outline of the package may suggest. This increased active surface area results in proportionally higher peak energy capability. SEMICONDUCTING CERAMIC ELECTRODES END TERMINATION FIGURE 3. MULTILAYER INNER ELECTRODES & SEMICON- DUCTING CERAMIC (CROSS-SECTION) Another advantage of this type of construction is that the breakdown voltage of the device is dependent on the dielec- tric thickness between the electrode layers and not the over- all thickness of the device. Increasing or decreasing the dielectric thickness will change the breakdown voltage of the device. Energy handling capability can be significantly increased with a larger overall package outline. The energy handling capability doubles from 0.6J (10/1000us waveform) for a 0.120 inch by 0.06 inch device to 1.2J for a 0.120 inch by 0.100 inch device. The crystalline structure of the ML transient voltage suppres- sor (TVS) consists of a matrix of fine, conductive grains separated by uniform grain boundaries, forming many P-N junctions (Figure 4). These boundaries are responsible for blocking conduction at low voltages, and are the source of the nonlinear electrical conduction at higher voltages. Conduction of the transient energy takes place between these P-N junctions. The uniform crystalline grains act as heat sinks for the energy absorbed by the device in a transient condition, and ensures an even distribution of the transient energy (heat) throughout the device. This even distribution results in enhanced transient energy capability and long term reliability. METAL ELECTRODES ^□□□□□□□MU ■ GRAINS FIGURE 4. MULTILAYER TRANSIENT VOLTAGE Package Outline The ML surge suppressor is a surface mountable device that is much smaller in size than the components it is designed to protect. The present size offerings are a "1210" form factor (0.120 inches x 0.100 inches) and a "1206" form factor (0.120 inches x 0.060 inches). Since the device is inherently bi-directional, symmetrical orientation for placement on a printed circuit board is not a concern. Its robust construction makes it ideally suitable to endure the thermal stresses encountered in the soldering, assembling and manufacturing steps involved in surface mount applications. As the device is inherently passivated by the fired ceramic material, it will not support combustion and is thus immune to any risk of flammability which may be present in the plastic or epoxy molded parts used in industry standard packages. 12-7 Application Note 9108 Characteristics Speed of Response The clamping action of the ML suppressor depends on a conduction mechanism similar to that of other semiconduc- tor devices. The response time of the zinc oxide material itself has been shown to be less than 500ps' 3 ' *• 5] . The apparent slow response time often associated with zinc oxide is due to parasitic inductance in the package and leads. Thus, the single most critical element affecting the response time of any suppressor is its lead length and, hence, the inductance in the leads. As the ML suppressor is a true surface mount device, with no leads or external pack- aging, it has virtually zero inductance. In actual applications, the estimation of voltage overshoot is of more practical relevance than that of speed of response. As a multilayer suppressor has essentially zero inductance it has little or no voltage overshoot. The actual response time of a ML surge suppressor is 1 ns to 5ns. This response time is more than sufficient for the transients which are likely to be encoun- tered by a component on a printed circuit board. Clamping Voltage The clamping voltage of a suppressor is the peak voltage appearing across the device when measured under the con- ditions of a specified pulse current and specified waveform. The industry recommended waveform for clamping voltage is the 8/2O41S pulse which has been endorsed by UL, IEEE and ANSI. The clamping voltage of the ML should be the level at which a transient must be suppressed to ensure that system or component failure does no occur. Shunt-type sup- pressors like the ML are used in parallel to the systems they protect. The effectiveness of shunt suppressors can be increased by understanding the important influence that source and line impedance play in a system, such as is shown in Figure 5. FIGURE 5. VOLTAGE DIVISION BETWEEN SOURCE, LINE AND SUPPRESSOR IMPEDANCE To obtain the lowest clamping voltage (V c ) possible, it is desirable to use the lowest suppressor impedance (Z su p PRESS0R ) and the highest line impedance (Z UNE ). The suppressor impedance is an inherent feature of the device, but the line impedance can become an important factor, by selecting location of the suppressor, or by adding resis- tances or inductances in series. V SUPPRESSOR x V SOURCE Temperature Dependence In the off state, the V-l characteristics of the ML suppressor approaches a linear (ohmic) relationship and shows a temperature dependent affect (Figure 6). The suppressor is in a high resistance mode (approaching 109Q) and appears as a near open circuit. This is equivalent to the leakage region in a traditional zener diode. Leakage currents at max- imum rated voltage are in the microamp range. When clamp- ing transients at higher currents (at and above the milliamp range), the ML suppressor approaches a near short circuit. Here the temperature variation in the characteristics of the ML becomes minimal throughout the full peak current and energy range (Figure 7). The clamping voltage of a multilayer transient voltage suppressor is the same at +25°C andat+125°C. < 10 -60 -50 -40 -30 -20 -10 TEMPERATURE (°C) 10 FIGURE 6. TEMPERATURE DEPENDENCE AT LOWER VOLTAGE 60 :> 50 AGE 40 a o > 30 15 Z Q. 20 S 5 o 10 V26MLA1206 V 14MLA12 06 V 3.5MLA1206 ' Z SUPPRESSOR + Z LINE + 2 SOURCE 20 40 60 80 100 120 140 160 TEMPERATURE (°C) FIGURE 7. CLAMPING VOLTAGE VARIATION OVER TEMPERATURE Peak Current Capability The peak current handling capability, and hence its ability to dissipate transient energy, is one of the ML suppressor's best features. This is achieved by the interdigitated construc- tion of the ML, which ensures that a large volume of suppressor material is available to absorb the transient energy. This structure ensures that the peak temperatures generated by the transient is kept low, because all of the package is available to act as an effective, uniform heat sink and absorb all the energy. 12-8 Application Note 9108 (Figure 8). Because of the low peak temperatures, the ML will experience very low thermal stress, both during heating and cooling. METAL ELECTRODES DEPLETION REGION GRAINS FIGURE 8. INTERDIGITATED CONSTRUCTION Repetitive pulsing on the ML suppressors (Figure 9) show negligible shift in the nominal voltage at one milliamp (less than 3%). There was also a minimal change in the leakage current of these devices. The Harris ML suppressor can also operate up to +125°C without any need for derating. V26MLA1206 1 50 A (8/20ms) 10,000 PULSES NOMINAL VOLTAGE AT 1mA V26 MLA1206 NUMBER OF PULSES FIGURE 9. REPETITIVE PEAK PULSE CAPABILITY Capacitance The ML suppressor is constructed by building up a compos- ite assembly of alternate layers of ceramic material and metal electrode. Since capacitance is proportional to area, and inversely proportional to thickness, the lower voltage ML's have a relatively high capacitance. Typical values of capacitance are shown in Table 2. TABLE 2. TYPICAL CAPACITANCE VALUES FOR 1206 MULTILAYER FAMILY CAPACITANCE (pF) DEVICE TYPE FREQUENCY (AT BIAS = 1 Vp.p) 1kHz 10kHz 100kHz 1MHz V5.5MLA1206 6250 5680 5350 5000 V14MLA1206 2750 2500 2360 2200 V18MLA1206 2100 1930 1830 1700 V26MLA1206 1000 910 860 800 V33MLA1206 600 550 520 500 V42MLA1206 550 520 480 450 V56MLA1206 410 380 360 350 V68MLA1206 190 170 160 150 Size A principal benefit of the new ML suppressor is their com- pact size in comparison to other surface mount components. The ML suppressor could be up to 50 times smaller than the components they are protecting. The small size of the ML offers an advantage in the saving of circuit board real estate and an ease in handling. Additionally, the solder mounting pads required for ML are much smaller, resulting in even more circuit board area savings. The present offering of multilayer suppressor sizes is 1 206 (0.120 x 0.060 inches) and 1210 (0.120 x 0.100 inches). Comparison to Other Transient Suppressors Peak Current and Energy Capability There are many design trade-offs involved in selecting the best transient suppression device for a given application. As previously mentioned, the large active electrode area available to the ML ensures that it's peak current handling capability is one of it's best features. Thus, by virtue of its construction, the ML is capable of dissipating significant amounts of energy over a small volume. The interdigitated construction of the ML means that the very high temperatures resulting from a transient occurrence will be dissipated through millions of P-N junctions. This is unlike a silicon suppressor, which has only one P-N junction available to handle a peak transient. Additionally, because many different materials with varying thermal coefficients of expansion are employed in the construction of a zener TVS, more extreme thermal stresses are created in transient energy dissipation and in the resulting temperature cycling. In an attempt to overcome this shortcoming, a number of silicon die are placed in series in a sandwich construction, with a metal header to act as a heat sink and solder pellets for bonding (Figure 10). This construction is designed to distribute the transient energy in more than one P-N junction, and will somewhat reduce the steep temperature build up. The reliability of such an approach is questionable. The metal sandwich is not completely effective in increasing the thermal capacity for transient pulses below 50us, because of the thermal time constant involved in transporting the energy (heat) from where it is generated (the silicon die) to the metal heat sink. Though high energy transients are much less frequent than low energy ones, it takes only one transient to completely damage the transient protector, and hence the component or circuit being protected. A device with no other function than to keep dangerous transients away from components may become the source of the problem if it shorts or opens, and leaves the circuit without protection. In the ML TVS, millions of P-N junctions are an integral part of the device structure, and it is this inherent advantage which gives excellent thermal properties. 12-9 Application Note 9108 FIGURE 10. DIFFERING THERMAL COEFFICIENT MATERIALS Comparing the typical peak current/power derating curves of the Harris multilayer to an equivalent silicon suppressor at +125°C, the ML has 100% of rated value while the zener diode has only 35% (Figure 11 ). TEMPERATURE (°C) FIGURE 11. ML AND ZENER DIODE POWER DERATING CURVES Clamping Voltage A well defined voltage avalanche characteristic is the best feature of a low voltage zener diode device, although it requires a high leakage current rating to achieve this. These diodes, recommended for the protection of 5V logic, have elevated temperature leakage specifications of 1000uA at their rated voltage. The leakage current of a zener diode can be reduced by specifying a higher voltage rated device, but this results in a higher clamping voltage and reduces the advantages of the zener diode. The V-l characteristic for a zener diode is defined over a small current range (1 decade). The ML current range is extended over a few more decades, which illustrates it's large peak current and energy handling capability. Temperature Effects Both the ML and the zener diode have a temperature depen- dance with respect to off state leakage current, with leakage current increasing as temperature increases. However, beyond the breakdown point, the clamping voltage of the ML will remain constant between +25°C and +125°C, while the clamping voltage for the zener diode at +125°C is higher than that specified at +25°C. Speed of Response Unfortunately, speed of response ratings do not represent the realizable response times of the transient suppressor in a typical system application. Traditional transient suppres- sors, zener diode and metal oxide varistors, for example, have finite lead inductance, and their response time is lim- ited (slowed) by these parasitic lead inductances. This limita- tion has been recognized by the IEEE committees on transient suppressors, with the conclusion that the response time of a suppressor is influenced by lead configuration and length. Unlike the leaded surface mount packages used in zener diodes, the ML suppressor is a true surface mount device. Since the ML has no leads, it has virtually no induc- tance and the principal factor contributing to response times is eliminated. Up to now, the only surface mounted surge suppressors available are leaded gull-wing and j-bend zener diodes or a relatively large surface mount metal oxide varistor. In such cases a large area of the PC board is needed for mount down. Electrically equivalent ML suppressors are as much as three to four times as small than their silicon counter- parts, resulting in significant surface mount PC board area savings (Figure 12). The compact size of the ML TVS is driven by the advantages of paralleled stacking, resulting in a high density energy absorber where the device volume is not taken up by lead frames, headers, external leads, and epoxy. Additional board area savings are realized with the smaller solder mounting area required by the ML as compared to the gull-wing or j-bend packages (Figure 13). ELEVATION VIEW PLAN VIEW | GULL WING J-BEND ML FIGURE 12. COMPARATIVE SURFACE MOUNT SURGE SUPPRESSORS c t B I DIMENSIONS A B C ML1206 0.203 0.103 0.065 Gull Wing 0.410 0.125 0.050 J -Bend 0.330 0.125 0.070 FIGURE 13. SOLDERING LAND PAD REQUIREMENTS 12-10 Application Note 9108 Applications Protection of Integrated Circuits and Low Voltage Circuits Protection against the coupling of transients are mainly required at two locations on the printed circuit board. The first is at the input/output port which affords protection of sen- sitive inputs to line drivers and receivers. The second location is at the power input to the integrated circuits at the input side of the board. This location will serve to keep the transient threat from transmitting throughout the rest of the board. In the past, IC's have been protected by means of decou- pling capacitors across the input power supply lines. The capacitors suppressed transients and supplied peak current for high speed switching operations. Unfortunately, the energy stored in the capacitor, and with it it's suppression capability, is very small: E = 1/2 * C * V 2 . Large electrolytic capacitors are usually placed on the output of the 5V supply. These capacitors are bulky and somewhat ineffective because of their poor high frequency response. Crowbars are also used to sense overvoltages. The crowbar functions such that an overvoltage shorts the output until the input fuse or circuit breaker opens, thereby turning the sys- tem off. Other concerns to consider as well as the power supplies and supply circuitry, are the input and output termi- nals carrying information. As long as the interconnections are short, transients do not seem to be a problem. However, when connections from board-to-board, system-to-system, or system-to-sensor are considered transients must be con- trolled (see Figure 14).' 7 ' SYSTEM 1 5V X X rfj iff T T SYSTEM 2 5V SYSTEM 1 MODEM 5V 12V MODEM 12V SYSTEM 2 5V FIGURE 14. SYSTEM-TO-SYSTEM AND SYSTEM-TO-SENSOR PROTECTION If the distances become long or interconnections between systems result in transient pick-up, then transient suppres- sion is a pre-requisite. Devices that are more effective than resistors and capacitors are needed to provide the neces- sary protection. Small spark gaps and silicon suppressors have been used quite effectively, but spark gaps still need a zener diode to reduce the initial voltage rise that triggers the spark gaps. Silicon suppressors, with their almost ideal V-l characteris- tics, are used quite extensively. However, zeners have low current-surge capabilities and are of limited value as a tran- sient suppressor when a relatively high magnitude transient is encountered. Surge capability is low because the thermal mass of the silicon chip, where all the energy of the tran- sients is to be converted into heat, is so small. Peak temper- atures can become so high that part of the silicon will melt, and the device will fail. On the other hand, there are zener diodes specifically designed for transient suppression. The thermal mass of these devices is increa more copper to the silicon pellet. This appn does not eliminate the basic problem. The transient energy is still converted into heat in the silicon pellet. The heat trav- els somewhat faster to the surrounding mass of copper. However, the large temperature differentials still exist. The mismatch of the thermal coefficient of expansion between the silicon and copper will create shearing forces that may lead to failures due to thermal fatigue. The low voltage V5.5MLA1206 may be used to protect inte- grated circuits requiring 5V on the input, e.g. all integ- rated circuits, systems containing low voltage IC's, memories, test equipment, data processing equipment, etc. The suppressor should be connected upstream form the IC to be protected. The maximum clamping voltage of the sup- pressor depends on the maximum transient current. If the clamping voltage is too high and the signal currents are low, a hybrid arrange- ment of a multilayer suppressor and a series impedance (an inductor or resistor) may be an effective and low cost solution. The series impedance should be as large as possible without distorting or attenuating the signal appreciably. The clamping voltage of the suppressor should be low, but high enough to prevent attenuation or distortion of the signal. CMOS Protection Latch-up is a phenomenon inherent in the basic CMOS structure. It is initiated by external conditions, is present only momentarily, and once induced is difficult to reverse, except by complete removal of power to the chip. Latch-up results in large current flow from V cc to ground. It can be triggered by an increasing voltage across the power terminal, such as an excessive voltage at the V cc pin (normally well above the maximum V cc rating of the device). This can be prevented by connecting a low voltage ML transient suppressor across V cc . Unfortunately, even if the systems power supply variations are kept small, individual inputs can still vary widely. Latch- up is also known to occur in CMOS systems when voltage supplied to an input exceeds the supply voltage. Again, tran- sients can be the culprit; the wrong sequence in power-up or power-down may have the same effect. A ML suppressor connected from V cc to ground will eliminate most of the latch-up problems caused by input over voltage. Additionally a ML suppressor connected from input to ground will help to protect the input from damaging transients such as electro- static discharge (Figure 15). |_Vcc I CMOS IC 5 OUTPUT V3.5MLA1206 FIGURE 15. PROTECTION OF CMOS DEVICES The new Harris V3.5MLA1206 represents a new method of protecting next generation 3.5V CMOS logic. New genera- 12-11 Application Note 9108 to overvoltage stress. No equivalent transient protection device currently available in a surface mount package can provide this level of protection. Discrete MOSFET Protection Over the years there has been an increasing migration from bipolar technology to MOSFET technology. This has resulted in an increase in the need for transient protection, for the system using the MOSFET. One reason for this is that a MOSFET is more susceptible to damage from electrostatic discharges than a bipolar transistor. Additionally, to take full advantage of the MOSFET, the voltage margins needed in a design should be minimized. This is because the incremental voltage increase for a MOSFET is more expensive than an equivalent incremental voltage increase for a bipolar transistor. When protecting the MOSFET transistor, its exceptionally fast switching times (50ns to 100ns) must also be consid- ered. The consequences of this fast switching time is a "ring- ing" in the wiring inductances connecting the MOSFET to the other components, resulting in the MOSFET being subjected to short duration transient voltages. By clamping these tran- sients to a safe low level it may be possible to use a lower cost MOSFET in the application. It is important when using a ML suppressor to connect it as close as possible to the drain and source leads of the MOSFET, in order to minimize the loop inductance. As the ML suppressor is a true surface mount package and has no lead inductance, this ensures that the MOSFET does not to suffer the additional transient volt- age overshoot associated with leaded suppressors. To protect the output of the MOSFET, the ML suppressor is connected between the drain and source (Figure 16). This ML must have a steady state voltage capability (V M (rjcj) which exceeds the worst case possible maximum supply voltage. Its clamping voltage at a peak transient current must be less than the minimum breakdown voltage of the MOSFET. For exam- ple, to protect against transients on a 28V ±10% supply, the V33MLA1206 ML suppressor with V| M(DC) of 33V can be used. According to the transient V-l curves of the ML data sheet, this will protect a MOSFET with a 60V minimum break- down from an approximate 10A transient pulse. GATE TO LOAD AND SUPPLY □ RAIN —i #=3 ML SUPPRESSOR FIGURE 16. DISCRETE MOSFET PROTECTION Additionally a ML suppressor can be used to protect the input of a discrete MOSFET from the threat of an ESD tran- sient. In the protection of a MOSFET driven with a 10V gate drive, the V14MLA1206 or VUMLA1210 suppressor should be connected from gate to source. These devices will protect against ESD pulses of 2kV to 25kV. The ML can also be used to protect MOSFETs (and bipolar transistors) from the transients generated when switching inductive loads. In this case, the ML selected must be able to dissipate the energy generated by the repetitive nature of these inductive load transient pulses (the average power of these transients must not exceed 0.25W). Automotive System Protection The increased use of surface mount technology in the auto- motive industry has resulted in the need for smaller, more densely packed boards with devices which have the perfor- mance capabilities of traditional through hole components. The transient conditions which may occur in the automobile is one of the best documented, and best understood transient environments. A load dump transient will develop when an alternator charging a flat battery is suddenly removed from the system. Peak voltages up to 125V may develop and can last for 200ms-400ms. Another common transient phenomena is a jump start which is generated when using a 24V truck bat- tery to start a car. This overvoltage may be applied for up to 3 to 5 minutes. Other transients result from relays and solenoids switching on and off, and from fuses blowing. Table 3 shows some sources, amplitudes, polarity, and energy levels of generated transients in the automotive elec- trical system' 8 '. TABLE 3. TYPICAL AUTOMOTIVE SUPPLY SUMMARY TRANSIENT LENGTH OF TRAN- SIENT CAUSE ENERGY CAPABILITY FREQUENCY OF OCCURRENCE VOLTAGE AMPLITUDE Steady State Failed Voltage Regulator Infrequent + 18V 3-5 Minutes Jump Starts with 24V Battery Infrequent ±24V 200ms to 400ms Load Dump; Disconnection to Battery While at High Charging >10J Infrequent <125V <320ms Inductive-Load Switching Tran- sient <1J Often -300V to +80V 200ms Alternator Field Decay < l.J Each Turn-Off -100V to -40V 90ms Ignition Pulse, Battery Discon- nected <0.5J <500Hz Several Times in Vehicle Life <75V 1ms Mutual Coupling in Harness <1J Often <200V 15ps Ignition Pulse, Normal <0.001J <500Hz Continuous 3V Accessory Noise <1.5V 50Hzto 10kHz Transceiver Feedback s20mV R.F. 12-12 Application Note 9108 Extension of Contact Life When relays or mechanical switches are used to control inductive loads, it is often necessary to derate the contacts to 50% of their resistive load rating due to the wear caused by the arcing of the contents. This arcing is caused by the stored energy in the inductive load. Each time the current in the inductive coil is interrupted by the mechanical contacts, the voltage across the contacts increases until the contacts arc. When the contacts arc, the voltage across the arc decreases and the current in the coil can increase some- what. The extinguishing of the arc causes an additional volt- age transient which can again cause the contacts to arc. It is not unusual for restriking to occur several times with the total energy in the arc several times that which was originally stored in the inductive load. It is this repetitive arcing that is so destructive to the contacts. A ML can be used to prevent initiation of the arc. Knowing the energy absorbed per pulse, the pulse repetition rate and the maximum operating voltage is sufficient to select the correct size ML suppressor. It is necessary to ensure that the device selected is capable of dissipating the power generated in the coil' 9 '. Part Number Nomenclature The part number of the ML device gives the following basic information: V33 MLA 1206 TTT DEVICE SIZE: 1206 = 0.120- X 0.060' 1210 = 0.120" X 0.100" SERIES DESIGNATION: Multilayer Suppressors MAXIMUM CONTINUOUS WORKING VOLTAGE: V M(DC ) Description of ML Ratings and Characteristics Maximum Continuous DC Working Voltage (V H ( DC )): This is the maximum continuous dc voltage which may be applied up to the maximum operating temperature (+125°C) of the ML. This voltage is also used as the refer- ence test point for leakage current. This voltage is always less than the breakdown voltage of the device. Maximum Continuous AC RMS Working Voltage (V M(AC) ): This is the maximum continuous sinusoidal rms voltage which may be applied. This voltage may be applied at any temperature up to +125°C. Maximum Non-Repetitive Surge Current (l TM ): This is the maximum peak current which may be applied for an 8720us impulse (Figure 17), with the V M(DC) or V M(AC) voltage also applied, without causing device failure. This pulse can be applied to the ML suppressor in either polarity. Maximum Non-Repetitive Surge Energy (W TM ): This is the maximum rated transient energy which may be dissipated for a single current pulse of 10/1000us, with the rated V M(DC) or V M(AC) voltage applied, without causing device failure. Maximum Clamping Voltage (V c ): This is the peak voltage appearing across the ML suppressor when measured for an 8/20us impulse and specified pulse current. The clamping voltage is shown for a current range of 1mA to 50A in the maximum transient V-l characteristic curves. Leakage Current (l L ): This is the amount of current drawn by the ML in its non-operational mode, i.e. when the voltage applied across the ML does not exceed the rated V M(DC) or V M (AC) voltage. Nominal Voltage (V N(DC) ): This is the voltage at which the ML begins to enter its conduction state and suppress tran- sients. This is the voltage defined at the 1mA point and has a minimum and maximum voltage specified. Capacitance (C): This is the capacitance of the ML when mea- sured at a frequency of 1MHz with 1 V P . P voltage bias applied. Oj = Virtual Origin of Wave T = Time From 10% to 90% of Peak T, = Virtual Front time = 1 .25 • t T 2 = Virtual Time to Half Value (Impulse Duration) Example: For an 8/20ns Current Waveform: 8ps = T, = Virtual Front Time 20(is = T 2 = Virtual Time to Half Value FIGURE 17. CURRENT TEST WAVEFORM Mountdown Recommendations Soldering The principal techniques used for the soldering of compo- nents in surface mount technology are Infra Red (IR) Reflow, Vapour Phase Reflow and Wave Soldering. Before solder- ing, the board and components must first be cleaned. A I, I, I, trichloroethane cleaning solvent in an ultrasonic bath, with a cleaning time of 2-5 minutes, is recommended for this operation. When wave soldering, the ML suppressor is attached to the substrate by means of an epoxy resin. When the epoxy adhesive is cured, the assembly is placed on a conveyor and run through the soldering process. With IR and vapour phase reflow the device is placed in a solder paste on the substrate. As the solder paste is heated it reflows and solders the unit to the board. With the ML suppressor, the recommended solder paste is a 60/40 Tin/Lead (Sn/Pb). While this configuration is best, a solder paste consisting of 62/36/2 (Sn/Pb/Ag) or a 63/37 (Sn/ Pb) can also be used with excellent results. 12-13 Application Note 9108 In soldering applications, the ML suppressor is held at ele- vated temperatures for a relatively long period of time. The wave soldering operation is the most strenuous process, as the components are immersed in the molten solder for sev- eral seconds. To avoid the possibility of stresses due to ther- mal shock occurring, a pre-heat stage in the soldering process is recommended, and the peak temperature of the solder bath should be rigidly controlled. When using the reflow process, care should be taken to ensure that the ML chip is never subjected to a thermal gradient steeper than 4 degrees per second; the ideal gradient being 2 degrees per second. When soldering preheating to within 100 degrees of the peak temperature is essential to minimize thermal shock. Some examples of typical soldering conditions are given in Table 4. TABLE 4. SOLDERING RECOMMENDATIONS SOLDERING OPERATION TIME (SECONDS) TEMPERATURE (°C) IR Reflow 5 - 10 220 Wave Solder 3-5 260 Vapour Phase 5 - 10 222 Once the soldering process has been completed, it is still necessary to ensure that any further thermal shocks are avoided. One possible cause of thermal shock is hot printed circuit boards being removed from the solder bath and sub- jected to cleaning solvents at room temperature. The boards must be allowed to cool to less than 50 degree Celsius before final cleaning. References [1] "An Overview of Electrical Overstress Effects on Semi- conductor Devices," D.G. Pierce and D.L. Durgin, Booz-Allen & Hamilton, Inc., Albuquerque, NM. [2] "Harris Semiconductor Application Note AN9003". [3] "Protection of Electronic Circuits From Overvoltages", Ronald B. Standler, 1989. [4] "ZnO Varistors for Transient Protection," L.M. Levinson, and H.R. Phillip, IEEE Trans. Parts, Hybrids and Pack- aging, 13:338-343, 1977. [5] "ZnO Varistors for Protection Against Nuclear Electro- magnetic Pulses," H.R Phillip, and L.M. Levinson, 1981. [6] "Overshoot: A Lead Effect in Varistor Characteristics," Fisher, FA., G.E. Company, Schnectady, NY, 1978. [7] "Harris Semiconductor Application Note AN9003". [8] "Harris Semiconductor Application Note AN9002". [9] "Transient Voltage Suppression Devices", Harris Semi- conductor DB450. 12-14 Harris Semiconductor No. AN9211 April 1993 Harris MOVs Soldering Recommendations for Surface Mount Metal Oxide Varistors and Multilayer Transient Voltage Suppressors Authors: Marty Corbett and Neil McLoughlin Introduction In recent years, electronic systems have migrated towards the manufacture of increased density circuits, with the same capability obtainable in a smaller package or increased capability in the same package. The accommodation of these higher density systems has been achieved by the use of surface mount technology (SMT). Surface mount technol- ogy has the advantages of lower costs, increased reliability and the reduction in the size and weight of components used. With these advantages, surface mount technology is fast becoming the norm in circuit design. The increased circuit densities of modem electronic systems are much more vulnerable to damage from transient overvort- ages than were the earlier circuits, which used relays and vac- uum tubes. Thus, the progress in the development of faster and denser integrated circuits has been accompanied by an increase in system vulnerability. Transient protection of these sensitive circuits is highly desirable to assure system survival. Surface mount technology demands a reliable transient volt- age protection technology, packaged compatibly with other forms of components used in surface mount technology. Harris Semiconductor has led the field in the introduction of surface mount transient voltage suppressors. These devices encompass voltages from S.SVpc to 275V AC and have a wide variety of applications. Their size, weight and inherent protection capability make them ideal for use on surface mount printed circuit boards. There are two standard series of Harris surface mount surge suppressors. The CH SERIES metal oxide varistors which encompass voltages from 14V[x; to 275V AC and the new ML SERIES which covers a voltage range from 3.5VQC to 68V DC . Metal Oxide Varistors A metal oxide varistor (MOV) is a non-linear device which has the property of maintaining are relatively small voltage change across its terminals while a disproportionately large surge current flows through it (Figure 1). When the MOV is connected in parallel across a line its non-linear action serves to divert the current of the surge and hold the voltage to a value that protects the equipment connected to the line. Since the voltage across the MOV is held at some level higher than the normal line voltage while surge current flows, there is energy deposited in the varistor during its surge diversion function. I FIGURE 1. V-l CHARACTERISTICS OF A MOV The basic conduction mechanism of a MOV results from semi- conductor junctions (P-N junctions) at the boundaries of the zinc oxide grains. A MOV is a mufti junction device with millions of grains acting as a series parallel combination between the electrical terminals. The voltage drop across a single grain in nearly constant and is independent of grain size. The CH series of surface mount metal oxide varistors are of a monolayer construction in a 5mm by 8mm package size. They are fully symmetrical and are passivated both top and bottom (Figure 2). The main advantage of this technology is its high operating voltage capability (68V DC to 275V AC ). The CH SERIES of metal oxide varistors are supplied in both T and 13" tape and reels. ELECTRODE PASSIVATION ZINC OXIDE MATERIAL 3 TERMINATION FIGURE 2. CROSS-SECTION OFTHE "CH" SERIES OF METAL Copyright © Hants Corporation 1993 Application Note 9211 Multilayer Transient Voltage Suppressors The Harris multilayer (ML) series of surface mount surge suppressors are of a multilayer construction. This technol- ogy, represents a recent breakthrough in its application to transient voltage suppression. The ML varistor is constructed by forming a combination of alternating electrode plates and semiconducting ceramic layers into a block. Each alternate layer of electrode is connected to opposite end terminations (Figure 3). The interdigitated block formation greatly enhances the available cross-sectional area for active conduction of transients. This paralleled arrangement of the inner electrode layers repre- sents significantly more active surface area than the small outline of the package may suggest. The increased active surface area results in proportionally higher peak energy capability. INNER ELECTRODES SEMICONDUCTING CERAMIC FIGURE 3. INTERNAL CONSTRUCTION OF THE HARRIS MUL- TILAYER TRANSIENT VOLTAGE SUPPRESSOR A further advantage of this type of construction is that the breakdown voltage of the device is dependent on the thick- ness between the electrode layers (dielectric thickness) and not the overall thickness of the device. The ML suppressor is a surface mountable device that is much smaller in size than the components it is designed to protect. The present size offerings are 1206, 1210, 1812 and 2220, with voltage ranges form 3.5V DC to 68V DC - Its robust construction makes it ideally suitable to endure the thermal stresses involved in the soldering, assembling and manufacturing steps involved in surface mount technology. As the device is inherently passivated by the fired ceramic material, it will not support combustion and is thus immune to any risk of flammability which may be present in the plastic or epoxy molded parts used in industry standard packages. Substrates There are a wide choice of substrate materials available for use as printed circuit boards in a surface mount application. The main factors which determine the choice of material to use are: 1. Electrical Performance 2. Size and Weight Limitations 3. Thermal Characteristics 4. Mechanical Characteristics 5. Cost When choosing a substrate material, the coefficient of thermal expansion of a Harris surface mountable suppressor of 6ppm/°C is an important consideration. Non-organic materials (ceramic based substrates), like aluminum or beril- lia, which have coefficients of thermal expansion of 5-7ppm°C, are a good match for the CH and ML series devices. Table 1 outlines some of the other materials used, and also their more important properties pertinent to surface mounting. While the choice of substrate material should take note of the coefficient of expansion of the devices. This may not be the determining factor in whether a device can be used or not. Obviously the environment of the finished circuit board will determine what level of temperature cycling will occur. It is this which will dictate the criticality of the match between device and PCB. Currently for most applications, both the CH and ML series use FR4 boards without issue. TABLE 1. SUBSTRATE MATERIAL PROPERTIES SUBSTRATE STRUCTURE MATERIAL PROPERTIES GLASS TRANSITION TEMPERATURE (°C) XY COEFFICIENT OF THERMAL EXPANSION (ppm/°C) THERMAL CONDUCTIVITY (W/M°C) Epoxy Fiberglass-FR4 125 14-18 0.16 Polyamide Fiberglass 250 12-16 0.35 Epoxy Aramid Fiber 125 6-8 0.12 Fiber/Teflon Laminates 75 20 0.26 Aluminium-beryillia (Ceramic) Not Available 5-7 21.0 12-16 Application Note 9211 Fluxes Fluxes are used for the chemical cleaning of the substrate surface. They will completely remove any surface oxides, and will prevent re-oxidation. They contain active ingredients such as solvents for removing soils and greases. Nonactivated fluxes ("R" type) are relatively effective in reducing oxides of copper, nickel or palladium/silver metallizations and are recommended for use with the Harris surface mount range. Mildly activated fluxes ("RMA" type) have natural and synthetic resins, which reduce oxides to metal or soluble salts. These "RMA" fluxes are generally not conductive nor corrosive at room temperature and are the most commonly used in the mounting of electronic components. The "RA" type (fully activated) fluxes are corrosive, difficult to remove, and can lead to circuit failures and other problems. Other non-resin fluxes depend on organic acids to reduce oxides. They are also corrosive after soldering and also can damage sensitive components. Water soluble types in particular must be thoroughly cleaned from the assembly. Environmental concerns, and the associated legislation, has led to a growing interest in fluxes with residues that can be removed with water or water and detergents (semi-aqueous cleaning). Many RMA fluxes can be converted to water soluble forms by adding saponifiers. There are detergents and semi-aqueous cleaning apparatus available that effectively remove most RMA type fluxes. Semi-aqueous cleaning also where large amounts of cleaning are needed. For the Harris Semiconductor range of surface mount varistors, nonactivated "R" type fluxes such as Alpha 100 or equivalent are recommended. Land Pad Patterns Land pad size and patterns are one of the most important aspects of surface mounting. They influence thermal, humidity, power and vibration cycling test results. Minimal changes (even as small as 0.005 inches) in the land pad pattern have proven to make substantial differences in reliability. This design/reliability relationship has been shown to exist for all types of designs such as in J lead, quadpacks, chip resistors, capacitors and small outline integrated circuit (SOIC) packages. Recommended land pad dimensions are provided for some surface mounted devices along with formulae which can be applied to different size varistors. Figure 4 gives recommended land patterns for the direct mount ML and CH series devices. TABLE 2. RECOMMENDED MOUNTING PAD OUTLINE L-(M + 2) I -+H (-»— T + M FT I W + 0.010 I k)R0.020W \ i w OR T SUPPRESSOR FAMILY DIMENSION T + M L-(M X 2) 0.020W (W + 0.010) 5 X 8 CH Series 2.21 (0.087) 5.79 (0.228) 5.50 (0.216) 1206 ML Series 1.65 1.85 (0.073) 2.62 (0.103) 1210 ML Series 1.85 (0.073) 1.85 (0.073) 3.73 (0.147) 1812 ML Series 1.85 (0.073) 3.20 (0.126) 4.36 (0.172) 2220 ML Series 1.84 (0.073) 4.29 (0.169) 6.19 (0.240) Solder Materials and Soldering Temperatures FIGURE 4. FORMULA FOR SURFACE MOUNT ABLE VARIS- TOR FOOTPRINTS TIME (SECONDS) FIGURE 5. RECOMMENDED MAXIMUM TIME AND SOLDER TEMPERATURE RELATIONSHIP OF HARRIS MOVs No varistor should be held longer than necessary at an elevated temperature. The termination materials used in both the CH and ML series devices are enhanced silver based materials. These materials are sensitive to exposure time and peak temperature conditions during the soldering process (Figure 5). The enhanced silver formulation contains either platinum, palladium or a mixture of both, which have the benefit of significantly reducing any leaching effects during soldering. To further ensure that there is no leeching of the silver electrode on the varistor, solders with at least 2% silver content are recommended (62 Sn / 36 Pb / 2 Ag). Examples of silver bearing solders and their associated melting temperatures are as follows: 12-17 Application Note 9211 TABLE 3. SILVER BEARING SOLDERS (ALPHA METALS) ALLOY MELTING TEMPERATURE °F °C 62 Sn / 36 Pb / 2 Ag 355 179 96.5 Sn /3.5 Ag 430 221 95 Sn / 5 Ag 430-473 221-245 20 Sn / 88 Pb / 2 Ag 514-576 268-302 5 Sn / 92.5 Pb / 2.5 Ag 536 280 Soldering Methods There are a number of different soldering techniques used in the surface mount process. The most common soldering processes are infrared reflow, vapor phase reflow and wave soldering. With the Harris surface mount range, the solder paste recommended is a 62/36/2 silver solder. While this configuration is best, other silver solder pastes can also be used. In all soldering applications, the time at peak temperature should be kept to a minimum. Any temperature steps employed in the solder process must, in broad terms, not exceed 70°C to 80°C. In the preheat stage of the reflow process, care should be taken to ensure that the chip is not subjected to a thermal gradient of greater than 4 degrees per second; the ideal gradient being 2 degrees per second. For optimum soldering, preheating to within 100 degrees of the peak soldering temperature is recommended; with a short dwell at the preheat temperature to help minimize the possibility of thermal shock. The dwell time at this preheat temperature should be for a time greater than 10T 2 seconds, where T is the chip thickness in millimeters. Once the soldering process has been completed, it is still necessary to protect against further effects of thermal shocks. One possible cause of thermal shock at the post solder stage is when the hot printed circuit boards are removed from the solder and immediately subjected to cleaning solvents at room temperature. To avoid this thermal shock affect, the boards must first be allowed to cool to less than 50°C prior to cleaning. Two different resistance to solder heat tests are routinely performed by Harris Semiconductor to simulate any possible effects that the high temperatures of the solder processes may have on the surface mount chip. These tests consist of the complete immersion of the chip in to a solder bath at 260°C for 5 seconds and also in to a solder bath at 220°C for 10 seconds. These soldering conditions were chosen to replicate the peak temperatures expected in a typical wave soldering operation and a typical reflow operation. Reflow Soldering There are two major reflow soldering techniques used in SMT today: 1. InfraRed (IR) Reflow 2. Vapor Phase Reflow The only difference between these two methods is the process of applying heat to melt the solder. In each of these methods precise amounts of solder paste are applied to the circuit board at points where the component terminals will be located. Screen or stencil printing, allowing simultaneous application of paste on all required points, is the most commonly used method for applying solder for a reflow process. Components are then placed in the solder paste. The solder pastes are a viscous mixture of spherical solder powder, thixotropic vehicle, flux and in some cases, flux activators. During the reflow process, the completed assembly is heated to cause the flux to activate, then heated further, causing the solder to melt and bond the components to the board. As reflow occurs, components whose terminations displace more weight, in solder, than the components weight will float in the molten solder. Surface tension forces work toward establishing the smallest possible surface area for the molten solder. Solder surface area is minimized when the component termination is in the center of the land pad and the solder forms an even fillet up the end termination. Provided the boards pads are properly designed and good wetting occurs, solder surface tension works to center component terminations on the boards connection pads. This centering action is directly proportional to the solder surface tension. Therefore, it is often advantageous to engineer reflow processes to achieve the highest possible solder surface tension, in direct contrast to the desire of minimizing surface tension in wave soldering. In designing a reflow temperature profile, it is important that the temperature be raised at least 20°C above the melting or liquidus temperature to ensure complete solder melting, flux activation, joint formation and the avoidance of cold melts. The time the parts are held above the melting point must belong enough to alloy the alloy to wet, to become homoge- nous and to level, but not enough to cause leaching of solder, metallization or flux charring. A fast heating rate may not always be advantageous. The parts or components may act as heat sinks, decreasing the rate of rise. If the coefficients of expansion of the substrate and components are too diverse or if the application of heat is uneven, fast breaking or cooling rates may result in poor solder joints or board strengths and loss of electrical conductivity. As stated previously, thermal shock can also damage components. Very rapid heating may evaporate low boiling point organic solvents in the flux so quickly that it causes solder spattering or displacement of devices. If this occurs, removal of these solvents before reflow may be required. A slower heating rate can have similar beneficial effects. InfraRed (IR) Reflow InfraRed (IR) reflow is the method used for the reflowing of solder paste by the medium of a focused or unfocused infra- red light. Its primary advantage is its ability to heat very localized areas. The IR process consists of a conveyor belt passing through a tunnel, with the substrate to be soldered sitting on the belt. 12-18 Application Note 9211 The tunnel consists of three main zones; a non-focused pre- heat, a focused reflow area and a cooling area. The unfo- cused infrared areas generally use two or more emitter zones, thereby providing a wide range of heating profiles for solder reflow. As the assembly passes through the oven on the belt, the time/temperature profile is controlled by the speed of the belt, the energy levels of the infrared sources, the distance of the substrate from the emitters and the absorptive qualities of the components on the assembly. The peak temperature of the infrared soldering operation should not exceed 220°C. The rate of temperature rise from the ambient condition to the peak temperature must be carefully controlled. It is recommended that no individual temperature step is greater than 80°C. A preheat dwell at approximately 150°C for 60 seconds will help to alleviate potential stresses resulting from sudden temperature changes. The temperature ramp up rate from the ambient condition to the peak temperature should not exceed 4°C per second; the ideal gradient being 2°C per second. The dwell time that the chip encounters at the peak temperature should not exceed 10 seconds. Any longer exposure to the peak temperature may result in deterioration of the device protection properties. Cooling of the substrate assembly after solder reflow is complete should be by natural cooling and not by forced air. The advantages of IR Reflow are its ease of setup and that double sided substrates can easily be assembled. Its biggest disadvantage is that temperature control is indirect and is dependent on the IR absorption characteristics of the com- ponent and substrate materials. On emergence from the solder chamber, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the IR reflow soldering process is as Table 4 and Figure 6. TABLE 4. RECOMMENDED TEMPERATURE PROFILE FOR IR REFLOW SOLDER PROCESS INFRARED (IR) REFLOW TEMPERATURE (°C) TIME (SECONDS) 25-60 60 60-120 60 120-155 30 155-155 60 155-220 60 220-220 10 220-50 60 -i 1 r 2 3 4 5 TIME (MINUTES) FIGURE 6. Vapor Phase Reflow Vapor phase reflow soldering involves exposing the assembly and joints to be soldered to a vapor atmosphere of an inert heated solvent. The solvent is vaporized by heating coils or a molten alloy, in the sump or bath. Heat is released and transferred to the assembly where the vapor comes in contact with the colder parts of the substrate and then condenses. In this process all cold areas are heated evenly and no areas can be heated higher than the boiling point of the solvent, thus preventing charring of the flux. This method gives a very rapid and even heating affect. Further advan- tages of vapor phase soldering is the excellent control of temperature and that the soldering operation is performed in an inert atmosphere. The liquids used in this process are relatively expensive and so, to overcome this a secondary less expensive solvent is often used. This solvent has a boiling temperature below 50°C. Assemblies are passed through the secondary vapor and into the primary vapor. The rate of flow through the vapors is determined by the mass of the substrate. As in the case of all soldering operations, the time the components sit at the peak temperature should be kept to a minimum. The dwell time is a function of the circuit board mass but should be kept to a minimum. On emergence from the solder system, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the vapor phase soldering process is as Table 5 and Figure 7. 12-19 Application Note 9211 TABLE 5. RECOMMENDED TEMPERATURE PROFILE FOR VAPOR PHASE REFLOW PROCESS VAPOR PHASE REFLOW TEMPERATURE (°C) TIME (SECONDS) 25-90 8 90-150 13 150-222 3 222-222 10 222-80 7 80-25 10 30 TIME (SECONDS) FIGURE 7. TYPICAL TEMPERATURE PROFILE Wave Solder This technique, while primarily used for soldering thru hole or leaded devices inserted into printed circuit boards, has also been successfully adapted to accommodate a hybrid technology where leaded, inserted components and adhe- sive bonded surface mount components populate the same circuit board. ■ The components to be soldered are first bonded to the substrate by means of a temporary adhesive. The board is then fluxed, preheated and dipped or dragged through two waves of solder. The preheating stage serves many func- tions. It evaporates most of the flux solvent, increases the activity of the flux and accelerates the solder wetting. It also reduces the magnitude of the temperature change experi- enced by the substrate and components. The first wave in the solder process is a high velocity turbulent wave that deposits large quantities of solder on all wettable surfaces it contacts. This turbulent wave is aimed at solving one of the two problems inherent in wave soldering surface mount components, a defect called voiding (i.e. skipped areas). One disadvantage of the high velocity turbu- lent wave is that it gives rise to a second defect known as bridging, where the excess solder thrown at the board by the turbulent wave spans between adjacent pads or circuit elements thus creating unwanted interconnects and shorts. The second, smooth wave accomplishes a clean up operation, melting and removing any bridges created by the turbulent wave. The smooth wave also subjects all previous soldered and wetted surfaces to a sufficiently high temperature to ensure good solder bonding to the circuit and component metallizations. In wave soldering, it is important that the solder have low surface tension to improve its surface wetting characteristics. Therefore, the molten solder bath is maintained at tempera- tures above its liquid point. On emergence from the solder wave, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the wave solder- ing process is as Table 6: TABLE 6. RECOMMENDED TEMPERATURE PROFILE FOR WAVE SOLDER PROCESS WAVE SOLDER TEMPERATURE (°C) TIME (SECONDS) 25-125 60 125-180 60 180-260 60 260-260 5 260-180 60 180-80 60 80-25 60 Cleaning Methods and Cleaning Fluids The objective of the cleaning process is to remove any contamination from the board, which may affect the chemical, physical or electrical performance of the circuit in its working environment. There are a wide variety of cleaning processes which can be used, including aqueous based, solvent based or a mixture of both, tailored to meet specific applications. After the soldering of surface mount components there is less residue to remove than in conventional through hole soldering. The cleaning process selected must be capable of removing any 12-20 Application Note 9211 contaminants from beneath the surface mount assemblies. Optimum cleaning is achieved by avoiding undue delays between the cleaning and soldering operations; by a minimum substrate to component clearance of 0.15mm and bv avoidina the hiah temperatures at which oxidation occurs Harris recommends 1, 1, 1 trichloroethane solvent in an ultrasonic bath, with a cleaning time of between two and five minutes. Other solvents which may be better suited to a particular application and can also be used may include one or more of the following: TABLE 7. CLEANING FLUIDS Water Isopropyl Alcohol Acetone Fluorocarbon 113 Ruorocarbon 113 Alcohol Blend N-Butyl 1,1,1 Trichloroethane Alcohol Blend Trichloroethane Toluene Methane Solder Defects Non-Wetting: This defect is caused by the formation of oxides on the termination of the components. The end termination has been exposed to the molten solder material but the solder has not adhered to the surface; base metal remains exposed. The accepted criterion is that no more than 5% of the terminated area should remain exposed after an immer- nonactive flux. Leaching: This is the dissolving of the chip termination into the molten solder. It commences at the chip corners, where metal coverage is at a minimum. The result of leaching is a weaker solder joint. The termination on the Harris surface mount suppressors consist of a precious metal alloy which increases the leach resistance capability of the component. Leach resistance defined as the immersion time at which a specified proportion of the termination material is visibly lost, under a given set of soldering conditions. De-Wetting: This condition results when the molten solder has coated the termination and then receded, leaving irregularly shaped mounds of solder separated by areas covered with a thin solder film. The base metal is not exposed. References [1] Transient Voltage Suppression Devices Manual (DB450), Harris Semiconductor. [2] CANE SMT 2588, Syfer Technology Limited, UK. 12-21 Harris Semiconductor No. AN9304.3 April 1994 Harris Intelligent Power ESD and Transient Protection Using the SP720 Author: Wayne Austin The need for transient protection in integrated circuits is driven by the quest for improved reliability at lower cost. The primary efforts for improvement are generally directed toward the lowest possible incidence of over-voltage related stresses. While electrical over-stress (EOS) is always a potential cause for failure; a discipline of proper handling, grounding and attention to environmental causes can reduce EOS causes for failure to a very low level. However, the nature of hostile environments cannot always be predicted. Electrostatic Discharge (ESD) in some measure, is always present and the best possible ESD interface protection may still be insufficient. As the technology of solid state progresses, the occurrence of ESD related IC failures is not uncommon. There is a continuing tendency for both ESD and EOS failures, due in part, to the smaller geometries of today's VLSI circuits. The solid state industry has generally acknowledged a stan- dard for the level of capability in LSI designs of ±2000V for the Human Body Model where the defined capacitance is 100pF and the series resistance is 1500Q. However, this level of protection may not be adequate in many applications and can be difficult to achieve in some VLSI technologies. Normal precautions against ESD in the environment of broad based manufacturing are often inadequate. The need for a more rugged IC interface protection will continue to be an established goal. Historically, it should be recognized that early IC develop- ment began to address the ESD problem when standards for handling precautions did not exist. High energy discharges were a common phenomena associated with monitor and picture tube (CRT) applications and could damage or destroy a solid state device without direct contact. It was recognized that all efforts to safe-guard sensitive devices were not totally sufficient. Small geometry signal processing circuits continued to sustain varying levels of damage through induced circulating currents and direct or indirect exposure in handling. These energy levels could be substantially higher than the current standard referenced in MIL-STD-3015.7; also referred to as the Human Body Model. The recognized need for improved ESD protection was first precipitated under harsh handling conditions; particularly in applications that interfaced to human contact or from the interaction of mechanical parts in motion. The popular features of component and modular electronic equipment have continued to generate susceptibility to IC damage while in continuing use. These market items include comput- ers and peripherals, telecommunication equipment and con- sumer electronic systems. While some IC's may only see the need for ESD protection while in manufacturing assembly or during service in the field, the most common cause for ESD failures can still be related to a human contact. Moreover, educational efforts have improved today's manufacturing environment substantially reduce failures that relate to the mechanical handling. The ESD failure causes that relate to mechanical handling now have a test standard referred to as a Machine Model which relates to the source of the generated energy. While the electrical model for an energy source is generally accepted as a capacitor with stored charge and a series resistance to represent the charge flow impedance, the best means to handle the high energy discharge is not so clearly evident. The circuit of Figure 1 illustrates the basic concept that is applied as a method of ESD testing for the Human Body Model. The ESD energy source is shown as a charged capacitor Cp and series connected, source impedance, resistor R D . The point of contact or energy discharge is shown, for test purposes, as a switch external to the IC. A protection structure is often included on an IC to prevent damage from an ESD energy source. To properly protect the circuit on the IC the on-chip switch, S s , is closed when a discharge is sensed and shunts the discharge energy through a low impedance resistor (R s ) to ground. It is imperative that the resistance of the discharge path be as low as practical to limit dissipation in the protection structure. It is not essential that the ground be the chip substrate or the package frame. The energy may be shunted via the shortest path external to the chip to an AC or DC ground. POINT OF ENERGY DISCHARGE ESD ENERGY SOURCE -VA O ACTIVE CIRCUIT (VERY LOW RESISTANCE) IC (CHIP) FIGURE 1 . ESD TEST FOR AN ON-CHIP PROTECTION CIRCUIT USING THE MIL-STD-883, METHOD 3015.7 (HUMAN BODY MODEL) Copyright © Harris Corporation 1 994 12-22 Application Note 9304 This conceptual method has been used in many IC designs employing a wide variation of structures, depending the IC technology and degree of protection needed. The switch, Ss is generally a threshold sensitive turn-ON at some voltage level above or below the normal signal range; however, it must be within the a safe operating range of the device being protected. The resistance, Rs is shown as the inherent series resistance of the protection structure when it is discharging (dumping) the ESD energy. In its simplest forms, the protection structures may be diodes and zeners, where the sensing threshold is the forward turn-ON or zener threshold of the device. The inherent resistance becomes the bulk resistance of the diode structure when it is conduct- ing. Successful examples of two such protection structures that have been used to protect sensitive inputs to MOS devices are shown in Figure 2. The back-to-back zener structure shown for the dual-gate MOSFET was employed in the 3N - dual gate MOS devices before IC technology was firmly established. The series poly and stacked diode structure used to shunt ESD energy followed several variations for use in CMOS technology and was employ in the CD74HC/HCT - High Speed CMOS family of logic devices. This CMOS protection structure is capable of meet- ing the 2000V requirements of MIL-STD-883, Method 3015.7; where the R D in Figure 1 is 1500Q and C D is 100pF. INPUT o Wl f WV- POLYR TO LOGIC G2 G1 T ° T ^ p -\ FIGURE 2. ESD AND TRANSIENT PROTECTION EFFECTIVELY USED IN MOS AND CMOS DEVICES Due to greater emphasis on Reliability under harsh applica- tion conditions, more ruggedized protection structure have been developed. A variety of circuit configurations have been evaluated and applied to use in production circuits. A limited introduction to this work was published in various papers by L. Avery (See Bibliography). To provide the best protection possible within economic constraints, it was determined that SCR latching structures could provide very fast turn-ON, a low forward on resistance and a reliable threshold of switching. Both positive and negative protection structures were readily adapted to bipolar technology. Other defining aspects of the protection network included the capability to be self-protecting to a much higher level than the signal input line being protected. Ideally, when a protection circuit is not otherwise needed, it should have no significant loading effect on the operating circuit. As such, it should have very little shunt capacitance and require minimal series resistance to be added to the signal line of the active circuit. Also, where minimal capacitance loading is essential for a fast turn-ON speed, the need for a simpler structure is indicated. The switching arrangement for a basic and simple protection structure is shown in Figure 3. Each high side and low side protection structure (R s and S s ) is an embedded device, taking advantage of the P substrate and epitaxial N material used in bipolar technology. Each cell contains an SCR with a series dropping resistor to sense an over-voltage turn-ON condition and trip the SCR (Switch S s ) into latch. The ON- resistance (Rs) of the latched SCR is much lower than R D and, depending on the polarity of the ESD voltage, dumps energy from the input signal line through the positive or neg- ative switch to ground. The return to ground for either ESD polarity is not limited by voltage supply definition, but may be to positive or negative supply lines, if this suits the needs of the application. When the energy is dissipated and forward current no longer flows, the SCR automatically turns-OFF. SIGNAL INPUT FIGURE 3. ESD AND TRANSIENT PROTECTION CIRCUIT Figure 4 shows the diagram of a positive and negative cell protection circuit as it applies to the SP720. The PNP and NPN transistor pairs are used as the equivalent SCR structures. Protection in this structure allows forward turn- ON to go marginally above the +V supply to turn-ON the high-side SCR or marginally below the -V supply to turn-ON the low-side SCR. The signal line to the active device is protected in both directions and does not add series imped- ance to the signal input line. A shunt resistance is used to forward bias the PNP device for turn-ON but is not directly connected to the signal line. As an on-chip protection cell, this structure may be next to the input pad of the active circuit; which is the best location for a protection device. However, for many applications, the technology of the active chip may not be compatible to structures of the type indicated in Figure 4. This is particularly true in the high speed CMOS where the substrates are commonly N type and connected to the positive supply of the chip. The protec- tion cell structure shown in Figure 4 is not required to be on the active chip because it does not sense series input current to the active device. The sense mechanism is voltage threshold referenced to the V+ and V- bias voltages. The cell structure of the SCR pair of Figure 4 are shown in the layout sketch and profile cutouts of Figure 5. It should be noted that the layout and profiles shown here are equivalent structures intended for tutorial information. The structures are shown on opposite sides of the 'IN" chip bonding pad, as is the case for the SP720. As needed for a preferred layout, 12-23 Application Note 9304 the structures are adjacent to the pad and as close to the positive and negative supply lines as possible. The common and best choice for effective layout is to provide a ground ring (V-) around the chip and to layout with minimum dis- tance paths to the positive supply (V+). In the SP720 the V- line is common to the substrate and frame ground of the IC. The equivalent circuit diagram of the SP720 is shown in Figure 6. Each switch element is an equivalent SCR structure where 14 positive and negative pairs as shown in Figure 4 are provided on a single chip. Each positive switch- EQUIVALENT SCR CIRCUIT SIGNAL INPUT FIGURE 4. PROTECTION CELLS OF THE SP720 SCR ARRAY METAL CONTACT B&R (P) Essza EMITTER (N+) rzzzzz ISO(P+) METAL CONNECTION ON-CHIP V+ "A' FIGURE 5A. HIGH AND LOW CELL PAIR LAYOUT; SHOWN WITHOUT PROTECT, METAL AND FIELD OXIDE LEVELS (NOT TO SCALE) HIGH SIDE LATCH PROTECTION STRUCTURE N^, VWramV^^ FIGURE 5B. PROFILES OF THE HIGH AND LOW SIDE SP720 SCR PROTECTION PAIR (NOT TO SCALE) 12-24 Application Note 9304 ing structure has a threshold reference to the V+ terminal, plus one V B £ (based-to-emitter voltage equal to one diode forward voltage drop). Similarly, each negative switching pair is referenced to the V- terminal minus one V BE . The internal protection cells of the SP720 are directly connect to the on-chip power supply line (+V) and the negative supply line (-V), which are substantial in surface metal content to provide low dropping resistance for the high peak currents encountered. Since both positive or negative transients can be expected, the SCR switches direct the positive voltage energy to V+ and the negative voltage sourced energy to V- (substrate) potential to provide fast turn-ON with low ON resistance to protect the active circuit. FIGURE 6. EQUIVALENT CIRCUIT DIAGRAM OF THE SP720 The V+ and V- supply lines of the SP720 are not required to be the same as those of the circuit to be protected. However, over-voltage protection is referenced to the V+ and V- supply voltages for all of the signal input terminals, IN1-IN7 and IN9-IN15. The V+ and V- supply voltages to the SP720 may be changed to suite the needs of the circuit under protection. The range of voltage may be power supply levels ranging from 4.5V up to the 35V maximum rating of the SP720. Lower levels of voltage are possible but with some degrada- tion of the switching speed which is nominally 6ns. Also, the input capacitance which is nominally 3pF can be expected to increase. There is no significant quiescent current in the SP720 other than reverse diode junction current which nominally less than 50nA over the rated -40°C to +105°C operating temperature. At room temperatures, this may be as low as a few nanoamperes. Because of the low dissipation of the SP720, the chip temperature can be expected to be close to the environment of the physical location where it is applied to use. Protection Levels of the SP720 For a given level of voltage or power, there is a defined degree of protection compatible to that need. For the SP720, the protection circuits are designed to clamp over-voltage within a range of peak current that will substantially improve the survival input expectancy of average monolithic silicon circuits used for small signal and digital processing applica- tions. Within itself, the SP720 should be expected to survival peak current and voltage surges within the maximum ratings defined in the data sheet. For voltage, the static DC and short duration transient capability is essentially the same. The process capability is typically better than 45V, allowing maximum continuous DC supply ratings to be conservatively rated at 35V. The current capability of any one SCR section is rated at 2A peak but is duration limited by the transient heating effect on the chip. As shown in Figure 7, the resis- tance of the SCR, when it is latched, is approximately 0.96£2 and the SCR latch threshold has 1 .08V of offset. For EOS, the peak dissipation can be calculated as follows: For: 2A Peak Current, R D = 1500n, Then: V| N(PK) = 1 .08V (Offset) + (0.960 x 2A) = 3V The peak dissipation is P D = 3V x 2A = 6W 1.08V FORWARD SCR VOLTAGE (V) FIGURE 7. SCR FORWARD CURRENT vs VOLTAGE CHARACTERISTICS While 2A through 1 500Q is 3000V, which is not an excep- tionally high ESD level of voltage, it does represent the EOS capability, provided the time duration for the 6W of dissipa- tion is limited to a few milliseconds. The dissipation of the 16 pin DIP and 16 pin SOIC packages are typically less than 1W for steady state conditions. The thermal capacity of the chip will allow discharge levels several times higher than this because ESD normally has a much shorter duration. The actual results for ESD tests on the SP720 as an isolated device are as follows: 1. Human Body Model using a modified version of the MIL- STD-883, Method 3015.7; with V+ and V- grounded and ESD discharge applied to each individual IN pin - Passed all test levels from ±9kV to ±1 6kV (1kV steps). 2. Human Body Model using the MIL-STD-883, Method 3015.7 (with V- only grounded) and ESD discharge applied to each individual IN pin - Passed all test levels to ±6kV, failed ±7kV (1kV steps). 12-25 Application Note 9304 3. Machine Model using EIAJ IC121 (R D = 0£i); discharge applied to IN pins with all others grounded - Passed all test levels to ±1 kV, failed ±1 .2kV; (200V steps). 4. While there are many potential uses for the SP720, the circuit of Figure 8 shows a normal configuration for protecting input lines to a sensitive digital IC. Each line is connected to an IN- Input of the SP720 in a shunt connection. As a test model a 2u digital ASIC CMOS IC was used to evaluate the ESD level of capability provided by the SP720. Without external protection, the ESD level of capability of the CMOS process was typically no better than ±2.5kV. When the SP720 was applied to use as shown in Figure 8, the ESD resistance to damage was better than ±10.2kV. (Higher levels were not evaluated at the time due to high voltage limitations.) It should be noted that the MIL-STD-883, Method 3015.7 test allows for one pin as a reference when testing. While this cannot be disputed as handling limitation, it is not a test for all aspects of applied use. To properly apply the SP720 to use in the application specifically requires that the V- pin be connected to a negative supply or ground and the V+ pin be connected to a positive supply. The SP720 was designed to be used with the supply terminals bias and, as such, has better than +16kV of ESD capability. For this reason, the modified test method as described, with the V+ pin connected via a ground return, is correct when the circuit is assembled for use. r v cc i -v cc — INPUT DRIVERS OR SIGNAL SOURCES SP720 J u IN 1-7 SP720 INPUT PROTECTION CIRCUIT (1 OF 14 ON CHIP) 1 IN 9-15 LINEAR OR DIGITAL IC INTERFACE V+ 8. PRACTICAL APPLICATION AND TEST EVALUATION CIRCUIT 12-26 Application Note 9304 SP720 CMOS Protection Model Where the need to provide ESD protection for CMOS circuits is the primary interest for the application of the SP720, inter- face characteristics of the device to be protected may lead to some specific problems. Application related issues and pre- cautions are discussed here to assist the circuit designer in achieving maximum success in EOS/ESD protection. CMOS Input Protection CMOS logic has limited on-chip protection and may contain circuit elements that add difficulty to the task of providing external protection. Consider the case where the input struc- ture of a CMOS device has on-chip protection but only to the extent that it will withstand Human Body Model minimum requirement for ESD when tested under the MIL-STD-883, Method 3015.7. This is normally ±2kV where the charged capacitor is 100pF and the series resistor to the device under test is 1 500S2 . The circuit of Figure 9 shows the typical network for an HC logic circuit where the input polysilicon resistor, R P is typically 120fl. When there is a surge or ESD voltage applied to the input structure, the diodes shunt current to V cc or GND to protect the logic circuits on the chip. The on-chip series resistors limit peak currents. If there is a positive transient voltage, V cs (t), applied to the input of the CMOS device, the diode, D-| will conduct when the forward voltage threshold exceeds the power supply voltage, V cc plus the forward diode volt- age drop of Di, V FWD1 . As the voltage at the input is further increased, the CMOS current, l cs is shunted through R P and Di to V cc such that the transient input voltage is V cs (t) = IcsW'Rp * Vfvto, + Vcc ['or Pos. V cs (t)] (EQ. 1 ) lcs(« = [Vcs(0 - (Vfwdi +V CC )]/R P (EQ. 1A) Similarly, when there is a negative transient, current initially conducts at the negative threshold of diode D 2 , V FWD2 to shunt negative current at the input, i.e. Vcs<») = IcsWRp +V FWD2 or (EQ. 2) lcs(t) = [VcsW • V FW D 2 ]/Rp (EQ. 2A) While the circuit of Figure 9 is specifically that of the HC logic family (one cell of the Hex Inverter, 74HCU04), many CMOS devices have a similar or an equivalent internal pro- tection circuit. When compared to the SCR structure of the SP720, the on-chip diodes of the protection network in Figure 9 have lower conduction thresholds. Vcs(t) "csW Rp U INPUT ESD/ -i- GND PROTECTION NETWORK - CHIP LOGIC SP720(1 of 14) FORWARD SCR CELL PROTECTION CIRCUIT v s (t) FIGURE 9. TYPICAL CMOS IC INPUT PROTECTION CIRCUIT REVERSE SCR CELL PROTECTION CIRCUIT FIGURE 1 0. SP720 SCR INTERFACE TO A CMOS INPUT WITH R, ADDED TO ILLUSTRATE MORE EFFECTIVE ESD PROTECTION FOR CMOS DEVICES SP720 to CMOS Interface Figure 10 shows the SCR cell structures of one protection pair in the SP720. In this example, the V+ of the SP720 is connected to the V c q logic supply and the V- is connected to logic GND. The IN terminal of the SP720 is connected to the CMOS logic device input through a resistor R|. When a neg- ative transient voltage is applied to the input circuit of Figure 10, the Reverse SCR Protection Circuit turns on when volt- age reaches the forward threshold of the PNP device and current conducts through the SCR resistor to forward bias the PNP transistor. The PNP device then supplies base cur- rent to forward bias and turn on the NPN device. Together, the PNP and NPN transistors form an SCR which is latched on to shunt transient current from IN to V-. The Forward SCR Protection Circuit has the same sequence for turn on when a positive transient voltage is applied to the input and conducts to shunt transient current from IN to V+ (V cc ). The Voltage-Current characteristic of the SCR is similar to a diode at low currents but changes to low saturated on resis- tance at high currents. As shown in the SP720 data sheet, the forward SCR (latched on) voltage is -1 V at 60mA which is -0.2V higher than a typically junction diode. The fully satu- rated turn on approaches 0.5A at 1.5V. When the SCR is paralleled with the a CMOS device input having an on-chip protection circuit equivalent to Figure 9, some of the current necessary to latch the SCR is shunted into the CMOS input. For some devices this may be sufficient for an ESD dis- charge to damage the CMOS input structure before the SP720 is latched on. The trade-off for achieving a safe level of ESD protection is switching speed. The most effective method is the addition of the series resistor, R| as shown in Figure 10. The series input resistor, as shown, is a practical method to limit current into the CMOS chip during the latch turn on of the SP720 SCR network. The value of R, is dependent on the safe level of current that would be allowed to flow into the CMOS input and the loss of switching speed that can be tolerated. The level of transient current, l cs that is shunted into the CMOS device is determined by the series resistor, R, and the volt- 12-27 Application Note 9304 age developed across the CMOS protection devices, R P and Di or D 2 , plus some contribution from the path of diode, D 3 for negative transients. As shown in Figure 11, the voltage across the SP720 SCR element is determined by its turn on threshold, V TH and the saturated resistance, R s when latched. The empirically derived equation for the voltage drop across the SP720 volt- age is V SP (t) = l SP (t)-R s + V TH (EQ. 3) or l SP (t) = [V SP (t) - V TH ]/(R S ) (EQ. 3A) where V TH - ±1.1 V and R s - 1Q. FORWARD SCR VOLTAGE DROP (V) FIGURE 11. FORWARD TURN ON CHARACTERISTIC OF AN SP720 SCR CELL where current conduction in the SP720 may be positive or negative, depending on the polarity of the transient. For the circuit of Figure 10, V s (t) is also the input voltage to the resistor, R| in series to the input of the CMOS device. When latched on, the impedance of the SP720 is much less than the input impedance of either R, or the CMOS input protec- tion circuit. Therefore, the CMOS loop current can be deter- mined by the voltage, V s (t) and the known conditions from Equation 3. For a negative transient input to the CMOS HCU04, the loop equation is V s (t) = l C s(t)'(R| + Rp) + V FWD2 (EQ. 4) or Icsd) = [V s (t) - VpwDai/fR, + R P ) (EQ. 4A) An equation solution for an input transient may be more directly solved by empirical methods because of the non-lin- ear characteristics. Given a transient voltage, V s (t) at the input, a value for R, can be determined for a safe level of peak current into a CMOS device. The input Voltage-Current characteristic of CMOS device should be known. As a first order approximation, the CMOS V-l curve tracer input char- acteristics of the 74HCU04 are shown in Figure 12. As indi- cated in Figure 12, the voltage drop across R P and R, in series (R P ~12(X2) will be significantly larger than the delta changes in the forward voltage drop of the D} or D 2 diodes over a wide range of current. As such, we can effectively assume V FWD - 0.75V for moderate levels of current. 25 I 1 1 -3 -2 -1 1 2 3 4 5 6 7 8 HCU04 FORWARD AND REVERSE VOLTAGE DROP (mV) FIGURE 12. FORWARD AND REVERSE PROTECTION CIRCUIT INPUT VOLTAGE-CURRENT CHARACTERISTIC OF THE HCU04 SHOWN FOR V cc = 5V, (i.e. D, THD - 5V + 0.7V) Example Transient Solution Based on the circuit of Figure 10, negative and positive ESD discharge circuit models of the SP720 and HCU04 are shown in Figure 13A and 13B. The negative ESD voltage is taken as the worse case condition because a positive ESD voltage will discharge to the Vcc power supply and the positive offset voltage will reduce the forward current. Using the negative model, a peak current value for l SP can be determined by the transient conditions of the applied voltage, V s (t) at the input. FIGURE 13A. NEGATIVE ESD DISCHARGE MODEL 12-28 Application Note 9304 FIGURE 13B. POSITIVE ESD DISCHARGE MODEL Given MIL-STD ESD HBM test conditions (C D = 100pF and Rn = 1500£i), Equation 3 with the resistors R D and R s in series, we can calculate the peak current for a specified volt- age, V D on the capacitor, C D . l S p(t) = [V D (t) - V TH ]/(R D + R s ) - V D (t)/R D (EQ. 5) Here, V D replaces V s as the driving voltage; and assumes that (1 ) R s is much less than R D ; (2) R s is much less than (R| + R P ); and (3) Vjh is much less than Vp. This may or may not be the general case but is true for the values indicated here. As such, [l S p]t = o~V D /1500. Given an ESD discharge of -15KV, neglecting inductive effects and distributed capacitance, the peak current at time t = will be -10A. And, with the SP720 latched on as shown in Equation 3, the 10A peak current will result in an ESD pulse at the input of the SP720 of -11V. For the HCU04 to withstand this surge of voltage, it is required that the drop- ping resistor, R| attenuate the peak voltage, V cs at the HCU04 input to within acceptable ratings. The negative reverse current path is through R,, R P and D 2 ; where R P and D 2 are part of the HCU04. For a negative ESD discharge voltage, V D from capacitor C D , the equation for the peak voltage, V cs at the input to the HCU04 is derived as fol- lows: Substituting Equation 5 into Equation 3, we have V s -(Vd/R d )-R s -1.1 (EQ.6) and from Equation 2 and Equation 4A, a general solution for the V cs voltage is V CS = l(V s - V FW D2)'(R| + RpM'Rp + V FWD 2 (EQ. 7) For a simpler approach, one can work backwards to arrive at the correct solution. The reverse CMOS voltage vs current curve of Figure 1 1 indicates that a peak voltage, V cs of -3V will produce a negative current of approximately -20mA which is the rated absolute maximum limit. For a -15kV ESD discharge and from Equation 6, the peak voltage, V s is V s = (VryR D )«R s - 1-1 = (-15/1500)-1.1 = -11.1V The peak current, l cs from Equation 4A is lcs = «v s -V F wD2V(Ri + Rp)] = [(-11.1 -(-0.7))]/(R, + Given the l cs current of -20mA and solving for R h R, = 397.5£2 The same result can be derived from Equation 7 but is more susceptible to rounding errors and the assumed voltage drop of V FWD2 due to the (V cs - V FWD 2) difference that appears in the equation. The approximation solution given here is based on a ±20mA current rating for the HCU04 device; although, input voltage ratings are exceeded at this level of current. As such, the solution is intended to apply only to short duration pulse con- ditions similar to the MIL-STD-883, Method 3015.7 specifica- tions for ESD discharge conditions. For long periods of sustained dissipation, the SP720 is limited by the rated capability of its package. -0.9 -0.8 < Ej C -0.6 D O £ ixi > -0.4 LU s 5 -0.3 K W -0.2 -0.1 A = *2S°C , = ion F HCU04 ( lcs) . SP72I +HCU04 ( -0.4 -0.8 -1.2 -1.6 -2.0 REVERSE VOLTAGE (V s ) TO THE SP720/HCU04 INPUT (V) FIGURE 14. MEASURED REVERSE CURRENT vs VOLTAGE CHARACTERISTIC OF THE SP720/HCU04 FOR THE FIGURE 10 CIRCUIT PROTECTION MODE Figure 14 shows the distribution of currents for the circuit of Figure 10 given a specific value of R,. Curves are shown for both l s (HCU04 + SP720) and l SP (SP720) versus a negative input voltage, V s . The resistor, R, value of 10£2 is used here primarily to sense the current flow into the HCU04. (This data was taken with the unused inputs to the HCU04 con- nected to ground and the unused inputs to the SP720 biased to V cc /2 on a resistive divider.) The Figure 14 curves verify the model condition of Figure 13A with the exception that resistive heating at higher currents increases the resistance in the latched on SCR. This curve explains the ESD protec- tion of the Harris High Speed Logic "HC" family and, in par- ticular, demonstrates the value of the R P internal resistor as protection for the HCU04 gate input. Added series resis- tance external to a signal input is always recommended for maximum ESD protection. Range of Capability While the SP720 has substantially greater ESD self protection capability than small signal or logics circuits such as the HCU04, it should be understood that it is not intended for 12-29 Application Note 9304 interface protection beyond the limits implied in the data sheet or the application note. The MIL-STD-883, Method 3015.7 condition noted here defines a human body model of 100pF and 1500Q where the capacitor is charged to a specified level and discharged through the series resistor into the circuit being tested. The capability of the SP720 under this condition has been noted as ±15kV. And, for a machine model where no resistance is specified, a 200pF capacitor is discharged into the input under test. For the machine model the level of capability is ±1 kV; again demonstrating that the series resistor used in the test or as part of the application circuit has pro- nounced effect for improving the level of ESD protection. While a series resistor at the input to a signal device can greatly extend the level of ESD protection, a circuit applica- tion, for speed or other restrictions, may not be tolerant to added series resistance. However, even a few ohms of resis- tance can substantially improve ESD protection levels. Where an ESD sensitive signal device to be protected has no internal input series resistance and interfaces to a potentially damag- ing environment, added resistance between the SP720 and the device is essential for added ESD protection. Circuits often contain substrate or pocket diodes at the input to GND or V cc . and will shunt very high peak currents during an ESD discharge. For example, if the HCU04 of Figure 14 is replaced with device having a protection diode to ground and no series resistor, the anticipated increase in input current is 10 times. Shunt capacitance is sometimes added to a signal input for added ESD protection but, for practical values of capacitance, is much less effective in suppressing transients. For most applications, added series resistance can substantially improve ESD transient protection with less signal degradation. A further concern for devices to be protected is forward or reverse conduction thresholds within the power supply range (not uncommon in analog circuits). Depending on the cost considerations, the power supply V+ and V- levels for the SP720 could be adjusted to match specific requirements. This may not be practical unless the levels are also common to an existing power supply. The solution of this problem goes beyond added series resistance for improved protec- tion. Each case must be treated with respect to the precise V-l input characteristics of the device to be protected. Interface and Power Supply Switching Where separate system components with different power supplies are used for the source signal output and the receiving signal input, additional interface protection circuitry maybe needed. The SP720 would normally have the same power supply levels as the receiving (input) device it is intended to protect. When the SP720 with its receiving inter- face circuit is powered off, a remote source signal may be activated from a separate supply (i.e., remote bus connected systems). The user should be aware that the SP720 remains active when powered down and may conduct current from the IN input to the V+ (or V-) supply. Within its own structure, any IN input of the SP720 will for- ward conduct to V+ when the input voltage increases to a level greater than a V BE threshold above the V+ supply. Sim- ilarly, the SP720 will reverse conduct to V- when the input voltage decreases to a level less than a V BE threshold below the V- supply. Either condition will exist as the V+ or V- level changes and will continue to exist as the V+ collapses to ground (or V-) when the SP720 supply is switched off. If a transient or power surge is provided from the source input to the IN terminal of the SP720, after the V+ has been switched off, forward current will be conducted to the V+/V cc power supply line. Without a power supply to clamp or limit the ris- ing voltage, a power surge on the input line may damage other signal devices common to the V cc power supply. Bypassing the V cc line may not be adequate to protect for large energy surges. The best choice for protection against this type of damage is to add a zener diode clamp to the Vqq line. The zener voltage level should be greater than V cc but within the absolute maximum ratings of all devices powered from the V C c supply line. Power Supply Off Protection, Rise/Fall Speed To illustrate the active switching of the SP720 and the speed of the SCR for both turn on and turn off, oscilloscope traces were taken for the circuit conditions of Figure 1 5. A pulse input signal is applied with NO supply voltage applied to the SP720. Figure 15 shows the positive and negative pulse conditions to V+ and V- respectively. The trace scales for Figure 15 are 10ns/division horizontal and 1V/division vertical. Input and output pulses are shown on each trace with the smaller pulse being the output. The smaller output trace is due to an offset resulting from the voltage dropped across the SCR in forward conduction. The OUT+ and OUT- pulses quickly respond to the rising edge of the input pulse, following within ~2ns delay from the start of the IN pulse and tracking the input signal. The output falls with approximately the same delay. Bibliography 1. L.R. Avery, "Electrostatic Discharge: Mechanisms, Protection Techniques, and Effects on Integrated Circuit Reliability", RCA Review, Vol. 45, No. 2, June 1984, Pg. 291 - 302. 2. L.R. Avery, "Using SCR's as Transient Protection Structures in Integrated Circuits," EOS/ESD Symp. Proa, 1983. Pg. 90 - 96. 3. MIL-STD-883D, 15 Nov 91, Electrostatic Discharge Sensitivity Classification, Method 3015.7, 22 Mar 89. 4. Machine Model Standard (R D = 0£2), EIAJ IC121 . 5. EOS/ESD-DS5.2, Proposed Standard, "EOS/ESD Association Standard for the Discharge (ESD) Sensitivity Testing - Machine Model (MM) - Component Level, Oct 92. 6. Harris Semiconductor, SP720. File No. 2791.5. Electronic Pro- tection Array for ESD and Overvoltage Protection. (16 Lead Plastic IC available in DIP and SOIC packages). 7. Harris Semiconductor, SP721, File No. 3590, Electronic Protec- tion Array for ESD and Overvoltage Protection (8 Lead Plastic IC in the SP720 family available in DIP and SOIC packages). 12-30 Application Note 9304 POSITIVE/FORWARD CONDUCTION HIGH SPEED ON/OFF PULSE (OUT+) FORWARD SCR CELL ±v GEN (son) REVERSE SCR CELL PROTECTION CIRCUIT OUT- GND NEGATIVE/REVERSE CONDUCTION HIGH SPEED ON/OFF PULSE (OUT-) FIGURE 15. SP720 CIRCUIT WITH NO POWER SUPPLY INPUT PULSE TEST WITH 50£1, (OV TO ±5V) INPUT. THE TRACE SCALES FOR OUT+ AND OUT- ARE 1V/DIV VERTICAL AND 10ns/DIV HORIZONTAL 12-31 Harris Semiconductor NO. AN9306 August 1993 Harris MOVs The New "C" III Series of Metal Oxide Varistors Authors: Martin Corbett and Paul Durnin Introduction The development of more sophisticated and less expensive semiconductors over the last 5-10 years has resulted in a dramatic increase in the consumer electronics market. It is not uncommon to see thousands of dollars worth of TV, VCR, music equipment, and computers in todays home. Accompanying this boom in the consumer market there has been an increased awareness, by the user, about system reliability. This is a result of the fact that solid state devices are very susceptible to stray electrical transients which may be present in the AC distribution system. Transient voltages can result from the sudden release of previously stored energy. Transients are sudden short term variations in the AC power and can be characterized by three things; they are undesirable, unpredictable and potentially destructive. Transients may be generated by light- ning, inductive load switching, electromagnetic pulses or electrostatic discharges. They occur randomly throughout the AC wave, generally lasting from a few microseconds to a number of milliseconds. Even for this very short time, they can do incalculable damage. The severity of the damage caused by the transient depends on, the magnitude of the transient, its waveshape duration and its frequency of occur- rence. Electrical overvoltages on AC mains can cause both permanent deterioration, or temporary malfunctions, of electronic components and systems. To be as effective as possible, the optimum transient suppressor must take into account transients that may be bidirectional in nature, that may appear at any point on the AC wave, and that may be of almost any duration. The suppressor selected needs to address all of the conditions to be effective. Not all original equipment manufacturers (OEMs) in the consumer market design transient, protection into their equipment. It is, therefore, left to the end user to provide their own protection. A wide variety of off-the-shelf protectors are available, the most common types being known as a "Transient Voltage Surge Suppressor" (TVSS). All major TVSS manufacturers use metal oxide varistors (MOVs) as the primary suppression technique in their systems. The use of correctly selected and installed MOVs have a long and proven history of successful field performance. Transient voltage surge suppressors can be obtained as either perma- nently connected fixtures or as cord and plug connected units. Permanently connected surge suppressors are an integral part of the electrical outlet and will protect any equipment which is plugged into that particular outlet. Permanently connected suppressors give continuous protection. Cord and plug connected suppressors are transportable protectors and will only protect from transients if they are plugged into an outlet at the time of the transient occurrence. The Transient Environment^ 2 3 4 5 i The environment in which transient overvoltages occurs varies dramatically from region to region. Primarily the problem is that of the enigmatic presence of overvoltage surges, above the normal system voltage. Overvoltages are sometimes explainable or sometimes they just suddenly appear in the electrical system; they may take the form of disturbances, notches, swells, sags, brownouts, outages or combinations of the above and are generically known as transients. Transients can be divided into two types; normal mode and common mode. A normal mode transient, sometimes referred to as a differential or transverse mode, is defined as a transient which occurs from line to line. Investigatory studies have shown that approximately 90% of all transients are normal mode occurrences. A common mode transient occurs between either line, and ground. The causes of the surges in an indoor AC electrical system can be attributed to one of the following causes: • Lightning • Opening or closing of switch contacts under load • Propagation of surges through transformers • Severe load changes in adjacent systems • Power line fluctuations and pulses • Short circuits or blown fuses. Transients caused by lightning can inject very high currents into the system. These lightning strikes, usually to the primary transmission lines, may result in coupling to the secondary line through mutual inductive or capacitive coupling. A direct strike is not the only damage lightning can do. The sudden change in an electrical field that occur during a cloud-to-cloud discharge can induce substantial voltages onto primary conductors, triggering lightning arrest- ers and creating transients. Copyright © Harris Corporation 1993 12-32 Application Note 9306 Man-made switching transients can be of a lesser, but more frequent threat. Such transients may be unpredictable and unrepeatable. Switching transients result from the rapid release of energy, e.g. switching of the power grid can cause transients which may damage equipment further along the electrical system. Studies and laboratory investigation of residential and industrial low voltage AC power systems have shown that the amplitude of the transient is proportional to the rate of its occurrence, i.e. lower magnitude transients occur most often. Governing standards bodies, in particular UL, IEEE and ANSI, have established standards which give practical guidelines to the transient environment one may expect to encounter in a low voltage AC power system. Typical examples are the ANSI/IEEE standard C62.41 and UL 1449. Rate of Occurrence The rate of occurrence of surges varies quite a lot and is dependent upon a particular power system. Rate of occurrence is related to the level of surges; low magnitude surges are more common than high level surges. An area described as a "low exposure" area would have very little lightning activity and few switching loads on the AC power system. A "medium exposure" area is known for high lightning activity, with frequent and severe switching transients. When designing equipment for the global environment it is expedient that it be, at least, designed for use in an area with "medium exposure" transient occurrences. "High exposure" areas are rare but real systems supplied by long overhead transmission lines and subject to reflections at line ends, where the characteristics of the installation produce high sparkover levels of the clearances. Lightning and switching transients generate overvoltages up to 10kV on the AC power lines. While this is the case, electronic equipment virtually never sees anything larger than 6kV. This is because the wiring systems used in indoor applications "flash over" at this 6kV level. Therefore, this is the maximum level that the aforementioned standards organizations have selected as the upper limit that electrical equipment is expected to be able to survive. The transient generated by this "flash over" creates a high energy, low impedance pulse. The further away from the source of the transient the protected equipment is located, the more the energy is absorbed in the wiring impedance and the more the equipment is protected. Representative Transients Table 1 reflects the surge voltages and currents deemed to represent the indoor transient environment in a low voltage AC power system. When deciding on the type of device to use as a transient voltage surge suppressor, it is generally recommended that the device selected have as a minimum the capability to handle the conditions called out in location Category B of Table 1 . TABLE 1 . SURGE VOLTAGES AND CURRENTS DEEMED TO REPRESENT THE INDOOR ENVIRONMENT IMPULSE LOCATION CATEGORY WAVEFORM MEDIUM EXPOSURE A Long Branch Cir- cuits and Outlets 0.5(is 100kHz 6kV 200A B Major Feeders and Short Branch Circuits 1.2/50HS 8/20ms 6kV 3kA 0.5ns 100kHz 6kV 500A Transient Protection Once the decision to include transient suppression has been made, the next stage in the process is to decide on what protection technology to use and on how to use it. The transient suppressor selected must be able to suppress surges to levels which are below the failure threshold of the equipment being protected, and the suppressor must survive a definite number of worst case transients. When comparing the various devices available considerations must be given to characteristics such as protection levels required, component survivability, cost, and size. "C" III Metal Oxide Varistor Series™ The new "C" III series of Harris radial metal oxide varistors represent the third generation of improvements in device performance and characteristics. The technology effort involved in the development of this new series concentrated on extending the existing performance and capability of the Harris second generation of metal oxide varistors. A metal oxide varistor (MOV) is a nonlinear device which has the property of maintaining a relatively small voltage change across its terminals while a disproportionately large surge current flows through it. This nonlinear action allows the MOV to divert the current of a surge when connected in parallel across a line and hold the voltage to a value that protects the equipment connected to that line. Since the voltage across the MOV is held at some level higher than the normal line voltage while surge current flows, there is energy deposited in the varistor during its surge diversion function. The basic conduction mechanism of a MOV results from semiconductor junctions (P-N junctions) at the boundaries of the zinc oxide grains. A MOV is a multi junction device with millions of grains acting as a series - parallel combination between the electrical terminals. The voltage drop across a single grain in nearly constant and is independent of grain size. The material of a metal oxide varistor is primarily zinc oxide with small additions of bismuth, cobalt, manganese and other metal oxides. The structure of the body consists of a matrix of conductive zinc oxide grains separated by grain boundaries, which provide the P-N junction semiconductor characteristics. When the MOV is exposed to surges, the zinc oxide exhibits a "bulk action" characteristic permitting it to conduct large amounts of current without damage. 12-33 Application Note 9306 The MOV has many advantages which make it ideal for use as a suppressor on the low voltage AC power line. The bulk nature of its construction gives it the required energy handling capability to handle the secondary level transients resulting from indirect lightning hits. MOV's are both cost and size effective, are widely available and do not have a significant amounts of voltage overshoot. The flexibility of their manufacture means that a variety of different sizes and packages are available for transient suppression in the indoor application. The characteristics of greatest importance for a metal oxide varistor in an AC surge environment are the peak current, energy handling, repetitive surge and temporary overvoltage capabilities. The focus of the design effort was on improving these characteristics and therefore offering the maximum protection presently available to the end user. The new "C" III series are designed to survive the harsh environments of the AC low-power indoor environment. Their much improved surge withstand capability is well in excess of the transients expected in the AC mains environment. Further design rules for the development of the "C" III series included considerations of the expected steady state operat- ing conditions and the repetitive surge environment. Transient Surge Withstand Capabilities The worst case transients encountered in the indoor AC environment may be represented by the combination wave of 6kV (1.2/50u.s) and 3kA (8/20u.s). This combination wave has been selected by Underwriters Laboratories (UL) for certification of all transient voltage surge suppressors to UL standard 1449. This standard calls out for a maximum surge transient withstand capability and also for duty-cycle withstand capability. The maximum surge withstand capability of 6kV, 3kA is proposed for cord and plug connected, direct plug in and permanently wired receptacle outlet type transient voltage surge suppressors. These peak transients are applied to the suppressor a total of three times, with normal line voltage also applied. The peak surge current rating of the new 20mm "C" III series of Harris metal oxide varistors is 9000A. This series of varis- tors are generally used for the permanently wired receptacle suppressors. Under the surge current withstand test require- ments of UL Standard 1449 (3 pulses of 3kA) these devices have a conservative rating of 20 such pulses. Continued stress testing at this level has shown an inherent device capability which commonly in excess of 100 pulses. See Figure 1 . The peak surge current rating of the new 14mm series of Harris metal oxide varistors is 6000 amps. This series of varistors are generally used for both the cord and plug connected and direct plug in types of suppressors Under the surge current withstand test requirements of UL Standard 1449 (3 pulses of 3kA) these devices have a conservative rating of 10 such pulses. Continued stress test- ing of these components at this level has shown an inherent device capability commonly is in excess of 40 pulses 400 > 13 Z 1 350 < J o vi: OLA: 0C 3ms) iTED FOR I 20 SI I I RGE 5) 10 20 30 40 50 60 70 80 90 100 110 120 NUMBER OF SURGES FIGURE 1 . TYPICAL REPETITIVE SURGE CURRENT CAPABIL- ITY OF "C" III SERIES MOVs As well as the surge current withstand test, UL Standard 1449 also has requirements for suppressor performance in a repetitive surge environment. The duty-cycle transient withstand test capability peak voltage and current levels are 6kV and 500A for both the cord and plug connected and direct plug in suppressors. For the permanently wired receptacle outlet the test levels are 6kV and 750A. In all cases the duty-cycle test requirements are for a total of 24 pulses, 12 in alternating directions. In the case of the 20mm size varistors, used for the permanently wired receptacle suppressors, their repetitive surge capability at 750A is 120 times. For the 14mm series of devices, used in cord and plug connected and direct plug in suppressors, the repetitive surge withstand capability is 80 pulses at 750A and 1 50 pulses at 500 amps. As in the previous case, this rating is conservative. Continued stress testing at the 750A level has shown an inherent device capability which com- monly is in excess of 250 pulses. See Figure 2. o > g z £ 2 u 600 V175LA20C 750A fa/JOne! 550 500 450 400 350 300 (RATED FOR 80 S URGES) 50 300 100 150 200 2 NUMBER OF SURGES FIGURE 2. TYPICAL REPETITIVE SURGE CURRENT CAPABIL- ITY OF "C" III SERIES MOVs The transient surge rating serves as an excellent figure of merit for the "C" III suppressor. This extremely high, inherent surge handling capability is one of the new "C" III suppressor's best features. The enhanced surge absorption capability results from improved process uniformity and enhanced construction. The homogeneity of the raw material powder and improved control over the sintering and assembly processes are contributing factors to this improvement. 12-34 Application Note 9306 AC Bias Reliability The "C" III series of metal oxide varistors were designed for use on the AC power line. The varistor is connected across the line and is biased with a constant amplitude sinusoidal voltage. If the varistor let through/leakage current increases with time, the power dissipation will also increase, with the ultimate possibility of thermal runaway and varistor failure. It should be noted that the definition of failure is a change in the nominal varistor voltage (V N ) exceeding ±10%, with an associated increase in the leakage current drawn by the MOV. Although this type of varistor is still functioning normally after this magnitude of change, devices at the lower extremities of V N tolerance may begin to dissipate more power. To guard against this possibility, an extensive series of statistically designed tests were performed to determine the reliability of the "C" III type of varistor under AC bias combined with high levels of temperature stress. To date, this test has generated over 50,000 device hours of operation at a temperature of 125°C. This temperature was selected in order to accelerate the stress testing, although the "C" III series are only rated at 85°C. Changes in the nominal varistor voltage, measured at 1mA, of less than 2% have been recorded. See Figure 3. > < E 100 100 200 300 400 500 600 700 800 900 1000 1100 TIME (HOURS) FIGURE 3. HIGH TEMPERATURE OPERATING LIFE +125°C FOR 1000 HOURS AT RATED BIAS Device Comparisons 17 - 81 A range of standard varistors, avalanche diodes, gas tube arresters and filter capacitors were evaluated under a 6kV, 0.5us x 100kHz ring wave. This transient replicates that called out in location Category A of the ANSI/IEEE C62.41, where most cord and plug connected and direct plug in suppressors are used, and is the most benign condition expected in this location. All of the selected devices are rated for use on a 120V AC line. The results obtained from this evaluation are per Table 2. The conclusions from this evaluation were: a) the silicon avalanche diode had the lowest level of performance; b) since location Category A is the location requiring the smallest sized suppressor, how can a device which does not survive this testing be considered an adequate suppressor? Not only does the avalanche diode fail, but it is also very expensive when compared with an equivalently rated metal oxide varistor. There are avalanche diodes available, in the 15kW family, which absorb large amounts of energy and it is assumed that these devices will meet the transient require- ments of this test. From a cost comparisons, these devices may be 15-20 times more expensive than an equivalent MOV. TABLE 2. COMPARATIVE PERFORMANCE DATA (NOTE: THE LOWER THE PROTECTION LEVEL IS THE BETTER) PROTECTION TECHNOLOGY DEVICE PART NO. AVERAGE PROTECTION LEVEL (kV) FAILS / SAMPLE SIZE Metal Oxide Varistor V130LA1 V130LA5 V130LA10A 0.51 0.50 0.47 0/10 0/10 0/10 Silicon Avalanche Diode 1.5KE200C 0.48 2/10 Gas Tube Surge Arrester CG2230 0.67 0/10 Filter Capacitor C280A - EA4K7 1.30 0/10 One of the primary requirements for a device rated for sup- pression of transients on the AC mains is its ability to handle large amounts of energy. In order for a device to have a high energy handling capability, it requires a large amount of bulk material with a high specific heat value in the immediate vicinity of the P-N junctions. The primary material in a metal oxide varistor is zinc oxide and the average grain size for a MOV used in an AC application is 20 microns. Observations over a range of compositional variations and processing conditions show a fixed voltage drop of between 2V-3V per grain with boundary junctions evenly distributed along their edges. In the case of a 14mm varistor, part V130LA10C, it would have an approximate volume of 220mm 3 of material in the immediate vicinity of the P-N grain junctions. An equiva- lent silicon avalanche diode would have approximately 0.106mm 3 in their single P-N junction vicinity. Comparing the volume of the varistor and the diode in the immediate vicinity of the junction, the varistor has more than 2000 times a larger mass available. Thus, the peak temperature in the bulk material of the varistor per energy absorbed is much lower than that for the single silicon avalanche diode junc- tion. It is the millions of P-N junctions, which are an integral part of the MOV structure, that gives it excellent thermal and energy handling properties. Reliability Performance of "C" III Series MOVs While the electrical ratings and characteristics of the "C" III series of MOVs are conservatively rated, samples of these devices have been subjected to a number of additional electrical and environmental stresses, over and above those specified. The results of this testing show an enhanced device performance. A summary of the reliability tests performed on the "C" III series are shown in Table 3. 12-35 Application Note 9306 TABLE 3. RELIABILITY TEST PERFORMANCE OF "C" III SERIES MOVS TEST REFERENCE STANDARD TEST CONDITIONS TEST RESULTS Surge Current UL 1449 IEEE/ ANSI C62.41 IEC 1051 9000A (8/20(is) 1 Pulse 0/165 6500A (8/20us) 2 Pulses 0/105 3000A (8/20MS) 20 Pulses 0/75 750A (8/20jis) 120 Pulses 0/65 Surge Energy UL 1449 IEEE/ ANSI C62.41 IEC 1051 90J (2ms) 1 Pulse 0/1258 Operating Life MIL-STD-202 Method 204D 125°C, 1000 Hours, Rated Bias Voltage 0/180 Temporary Overvoltage N/A 120% Maximum Rated Varistor Voltage for 300s 0/70 Device Selection After evaluating the advantages and disadvantages of the various suppression technologies available, the device of choice is clearly the metal oxide varistor. Once the decision has been made as to which technology to use, it is now necessary to decide on the actual device to select for a particular application. To select the correct varistor for a specific application, determine the following information: 1. The maximum system RMS voltage 2. How the MOV is to be connected? 3. The MOV rating with a voltage 10-25% above system voltage 4. The worst-case transient energy that will need to be absorbed by the MOV. (Use the guidelines called out in ANSI/IEEE C62.41 1992) 5. The clamping voltage required for system protection Device Features • Recognized as "Transient Voltage Surge Suppressors" to UL 1449; File E75961 • Recognized as "Transient Voltage Surge Suppressors" to CSA C22.2, No. 1; File LR91788 High energy absorption capability: W TM (2ms). 45J to 120J • High peak pulse current capability: l TM = 6000A to 9000A (8/20us) • Wide operating voltage range: V M(AC)RMS = 130V to 175V Available in tape and reel for automatic insertion; also available with trimmed and/or crimped leads. "C" III MOV Terms and Descriptions Rated AC Voltage (V M(AC)R ms) " This is ,he maximum con- tinuous sinusoidal voltage which may be applied to the MOV. This voltage may be applied at any temperature up to the maximum operating temperature of +85°C. Maximum Non-Repetitive Surge Current (l TM ) - This is the maximum peak current which may be applied for an 8/20us impulse, with rated line voltage also applied, without causing device failure. Maximum Non-Repetitive Surge Energy (W TM ) - This is the maximum rated transient energy which may be dissipated for a single current pulse at a specified impulse and duration (2ms), with the rated RMS voltage applied, without causing device failure. Nominal Voltage (V N(DC) ) - This is the voltage at which the device changes from the off state to the on state and enters its conduction mode of operation. This voltage is character- ized at the 1mA point and has specified minimum and maxi- mum voltage levels. Clamping Voltage (V c ) - This is the peak voltage appearing across the MOV when measured at conditions of specified pulse current amplitude and specified waveform (8/20us). References [1] "ANSI/IEEE C62.411992 Guide On Surge Voltages In Low Voltage AC Power Circuits". [2] "Voltage Transients and Their Suppression", Corbett, M. [3] "Understanding AC Line Transient Immunity", Dash, G. and Straus, I. [4] "Suppression Of Voltage Transients Is An Art Trying To Be A Science", GE 660.33. [5] "The Propagation and Attenuation of Surge Voltages and Currents in Low Voltage AC Circuits", Martzloff, F.D., 1984. [6] 'Transient Voltage Suppression Devices", Harris Semi- conductor DB450. [7] "Protective Level Comparison of Voltage Transient Sup- pressors", Hopkins, D. C. [8] "Comparison of Transient Suppressors!", Korn, S. 12-36 Harris Semiconductor NO. AN9307.1 March 1995 Harris MOVs The Connector Pin Varistor for Transient Voltage Protection in Connectors Introduction Authors: Paul McCambridge and Martin Corbett Nonlinear devices have long been used for transient voltage protection and have bee available in conventional package configurations - axial, radial, and power packages (Figure 1 ) The connector pin varistor represents a new approach to transient suppression by forming the active material into a shape which requires no leads or package (Figure 2) The idea was developed many years ago, but only recently have breakthroughs in the manufacturing process allowed cost- effective production of such devices. an extremely low value, limiting the voltage rise across the varistor (Figure 3). The destructive energy is absorbed by circuit impedance and varistor impedance. Energy is converted into hear and, if the varistor is properly rated, no components are harmed. M FIGURE 1. CONVENTIONAL PACKAGE CONFIGURATIONS METALLIZED PIN ELECTRODE FIGURE 2. TUBULAR VARISTOR (CONNECTOR PIN VARISTOR) Connector pin varistors are voltage dependent nonlinear semiconducting devices having electrical behavior similar to back-to-back zener diodes. The symmetrical sharp break- down characteristic enables the varistor to provide excellent transient suppression. As the voltage of a transient rises, the impedance of the varistor changes from a very high value to ■ FIGURE 3. VOLTAGE IMPEDANCE CHARACTERISTICS OF A TYPICAL VARISTOR To obtain the lowest clamping voltage, the impedance of the varistor (Z s ) and the impedance of the varistor leads (Z c ), should be as low as possible, but the impedance of the line (Z L ) and the transient source (Z T ) should be as high as pos- sible (Figure 4). The part of Z L which is contributed by the ground return also reduces Z L , but at the same time lifts the ground above true ground and therefore should be small. Unfortunately, the impedance of the transient source (Z T ) cannot be controlled and is unknown in most instances.' 1 ' Z L LINE IMPEDANCE Z T TRANSIENT SOURCE IMPEDANCE Zc CONNECTION IMPEDANCE Z s SUPPRESSOR IMPEDANCE V c CLAMPING VOLTAGE V T TRANSIENT VOLTAGE FIGURE 4. IMPEDANCE RELATIONSHIP IN A TRANSIENT SUPPRESSOR CIRCUIT Copyright © Harris Corporation 1995 12-37 Application Note 9307 Varistors contain zinc oxide, bismuth, cobalt, manganese and other metal oxides. The structure of the body consists of conductive zinc oxide grains surrounded by a glassy layer (the grain boundary) which provides the 2.5V PN-junction semiconductor characteristics. Figure 5 shows a simplified cross section of the varistor material. DEPLETION t_ " REGION r □□aw nn r tr THICKNESS GRAINS FIGURE 5. SIMPLIFIED MICROSTRUCTURE OF A VARISTOR MATERIAL The varistor is a multi-junction device with many junctions in parallel and series. Each junction is heat sunk by zinc oxide grains resulting in low junction temperatures and large over- load capabilities. As shown in Figure 5, the more junctions that are connected in series, the higher the voltage rating and as more junctions are connected in parallel, the higher the current rating. Energy rating, on the other hand, is related to both voltage and current and is proportional to the volume of the varistor. In summary: • Thickness is proportional to voltage • Area is proportional to current (a x b) or [(d2 • TC)/4] or (d • 71 • length). • Volume is proportional to energy (area x thickness) Electrical Characteristics An electrical model for a varistor is represented by the equivalent circuit shown in Figure 6. C|NT "OFF FIGURE 6. VARISTOR EQUIVALENT CIRCUIT Pulse Response The pulse response of a varistor is best understood by using the equivalent circuit representation consisting of a pure capacitor (Cp), two batteries, the grain resistance (Rz„o) and the intergrain capacitance (C| NT ). The off-resistance (Roff) is not applicable in this discussion. Due to the varistor capacitance (Cp), the varistor is initially a short circuit to any applied pulse. Varistor breakdown conduction through (V B1 ) and (V B2 ), as illustrated in Figure 6 does not occur until this capacitor is charged to the varistor breakdown voltage (V B ). The time is calculated by: t c = C P . (V B1 /I) or (2) Where I is the average pulse current (capacitor charging current) for < t < t c . The value of the peak current is controlled by I = (di/dt) • C P , the source impedance voltage of the transient, and the varistor's dimensions (area proportional to C). For longer duration pulses t > t c , V B1 and V B2 will participate on the current conduction process, as the voltage on C P rises above the breakover voltage (V B ). Speed of Response The conduction mechanism is that of a II - VI polycrystalline semiconductor. Conduction occurs rapidly, with no apparent time lag even in the picosecond range. Figure 7 shows a composite photograph of two voltage traces with and without a varistor connected to a low-induc- tance high speed pulse generator having a rise time of 500ps. The second trace is not synchronized with the first, but merely superimposed on the oscilloscope screen, show- ing the instantaneous voltage clamping effect of the varistor. There is no delay or any indication which would justify con- cern about response time. SB" TRACE 1 ' LOAD VOLTAGE WITHOUT VARISTOR . TRACE 2 LOAD VOLTAGE CLAMPED BY VARISTOR 500ps/DIV. FIGURE 7. RESPONSE OF A VARISTOR TO A FAST RISING PULSE (dv/dt = 1MV/ns) Using conventional lead-mounted varistors, the inductance of the leads completely masks the fast action of the varistor; therefore, the test results as shown in Figure 7 required the insertion of a small piece of varistor material in a coaxial line to demonstrate the intrinsic varistor response. Tests made on lead-mounted devices, even with careful attention to minimize lead length, show that the voltage induced through lead inductance contributes substantially to the voltage appearing across the varistor terminals (Figure 8). These undesirable induced voltage are proportional to lead inductance and di/dt and can be positive or negative. 12-38 Application Note 9307 c = d r L V c = CLAMPING VOLTAGE FIGURE 8. THE ELECTRICAL EQUIVALENT OF A LEAD- MOUNTED VARISTOR Figure 9 shows the positive and negative part of the induced voltage, resulting from a pulse with a rise time of 4ns to a peak current of 2.5A. When the measurement is repeated with a leadless varistor, such as the connector pin varistor, its unique coaxial mounting allows it to become part of the transmission line. This completely eliminates inductive lead effect (Figure 10). Calculations of the induced voltage as a direct result of lead effect for different current rise times provides a better under- standing of the di/dt value at which the lead effect become significant. Table 1 is based on an assumption of a current pulse of 10A, 1 inch of lead wire (which translates into approximately 15nH) and rise times ranging from seconds to femtoseconds. t„ = 4ns FIGURE 9. EXPONENTIAL PULSE APPLIED TO A RADIAL DEVICE (5V/DIV., 50S/DIV.) 9 l PEAK = 2.5A,300V FIGURE 10. EXPONENTIAL PULSE APPLIEDTO A PIN-VARISTOR (5WDIV., 50nS/DIV.) TABLE 1 . INDUCED VOLTAGE IN 1 1N. LEADS. PEAKCURRENT 10A, AT DIFFERENT CURRENT RISE TIMES TIME L e 1 x 10° 1 sec. 10A 15nH 150 X 10" 9 1 x 1CP 5 1ms 10A 15nH 150 x 10 -5 1 x 10 -5 1ns 10A 15nH 150 x 10' 3 1 x 10" 9 1ns 10A 15nH 150 1 x 10" 12 1ps 10A 15nH 150 x10' 3 1 x icr 18 1fs 10A I onn 150 x10" 6 Figure 11 illustrates the lead effect even more dramatically for fast rising pulses ranging in rise time from milliseconds to femtoseconds. MODEL 10,000,000 FEMTO PICO 1.5V> * «. 0.05 I io-» I 10" 7 I 10 5 T— I 10" 3 I NANO MICRO MILLI TIME IN SECONDS FIGURE 1 1 . LEAD EFFECT OF 1 INCH CONNECTION (L = 1 5nH) Temperature Coefficient (Electrical) The temperature coefficient is usually of little importance. It is most pronounced at low voltage and current levels and decreases to practically zero at the upper end of the V-l characteristics (Figure 12). 5? 0.1 i ° 5 C -0.1 C ui O -0.2 u £ -0.3 D 5 -0.4 LEAKAGE REGION tu -0.5 NORMAL OPERATION z SAMHLb I YKfc V130LA10A 10 s 10" 4 10' 3 10 2 10-' 10° 10 1 10 2 10 3 CURRENT (A) FIGURE 12. TYPICAL TEMPERATURE COEFFICIENT OF VOLT- AGE vs CURRENT (-55°C to +125°C) 12-39 Circuit designers may ask, "Why use connector pin varistors when suppressors could be located on the printed circuit board of the electronic control module (ECM)?" Reasons include saving space and avoiding side effects of circuit board suppressor action. A simplified schematic of an ECM is illustrated in Figure 13. Suppressors usually would be installed across the power analog and digital signal lines entering the ECM. These would divert surges to ground to avoid upset or damage of the ICs fed by those lines. However, side effects could occur if the suppressors are located internally. The paths of circulating current for diverting surges to ground could be of significant length and impedance. If the suppressor current paths share some impedance, then a surge current in one suppressor could cause a surge voltage on the ground line of another circuit. Also, surges can be coupled from one line to another within the ECM by radiation or by capacitive means. These problems are even more likely with surges that have fast fronts causing high V = Ldl/dt voltages, such as when has tubes are activated. DIGITAL FIGURE 13. CIRCUIT BOARD SUPPRESSOR INSTALLATION The above concerns are avoided when connector pin varistors are used as shown in Figure 14. Currents then can be diverted directly to a grounding plate within the connector which, in turn, terminates to the exterior of the ECM shielded housing. Surge currents stay outside of the "black box," and sensitive circuits are not exposed to the side effects of suppressor operation. Even if the ICs have on-chip suppressors for ESD protection, or the PC board has local suppressors, the connector pin varistors are desirable because they can divert some of the surge. This permits the local devices, in combination with line impedances and filter chokes, if present, to become secondary protectors. The local surge currents will be less, surge coupling side effects will be reduced, and lower clamping voltages can be attained. T-t^T- COMMUNICATION 2_ FIGURE 14. CONNECTOR PIN VARISTOR INSTALLATION Connector Pins vs Zener Diodes Clamping Voltage Clamping voltage is an important feature of a transient suppressor. Zener diode type devices have lower clamping voltage than varistors (Figure 15). Because all protective devices are connected in parallel with the device or system to be protected, a lower clamping voltage will apply less stress to the device protected. CURRENT FIGURE 15. CHARACTERISTICS OF ZENER AND VARISTOR Speeds Compared Response times of less than 1ps are claimed for zener diodes. For varistors, measurements were made down to 500ps with a voltage rise time (dv/dt) of 1 million volts per microsecond. Another consideration is the lead effect, previously discussed. Both devices are fast enough to respond to any practical requirements, including NEMP type transients. Leakage Currents Leakage current and sharpness of the knee are two areas of misconception about the varistor and zener diode devices. Figure 16 shows a zener diode and a varistor, both recom- mended by their manufacturers for protection of integrated circuits having 5V supply voltages. 12-40 Application Note 9307 The zener diode leakage is about 100 times higher at 5V than the varistor, 200uA versus less than 2uA For a leakage current comparison, 25 zener diode devices were measured at +25°C. Only 1 device measured 30mA. The rest were 150mA and more. At elevated temperatures, the comparison is even more favorable to the varistor. The zener diode is specified at 1000mA at 5.5V. The leakage current of a zener can be reduced by specifying a higher voltage device which would have a lower leakage current, but the price is a higher clamping voltage and the advantage of the zener disappears. FIGURE 16. CHARACTERISTICS OF A ZENER DIODE (ON LEFT) vs A VARISTOR (ON RIGHT) Peak Pulse Power Transient suppressors have to be optimized to absorb large amounts of power or energy in a short time duration: nanoseconds, microseconds or, in some rare instances, milliseconds. Electrical energy is transformed Into heat and has to be distributed instantaneously throughout the device. Transient thermal impedance is much more important than steady- state thermal impedance, as it keeps peak junction temperature to a minimum. In other words, head should be instantly and evenly distributed throughout the device. The varistor meets these requirements: an extremely reliable device with large overload capability. Zener diodes on the other hand, transform electrical energy into hear in the depletion region, an extremely small area, resulting in high peak temperature. From there the hear will flow through the silicon and solder joint to the copper. Thermal coefficient mismatch and large temperature differentials can result in an unreliable device for transient suppression. Figure 1 7 shows peak pulse power versus pulse width for the varistor and the zener diode, the same devices compared for leakage current. At 1 ms, the two devices are almost the same. At 2us the varistor is almost 10 times better, 7kW for the zener versus 60kW for the varistor. 1ms 2.0 10us 20 PULSE TIME 100ns 1000ms FIGURE 17. PEAK PULSE POWER vs PULSE TIME Aging A common misconception is that a varistor's V-l characteris- tics changes every time energy is absorbed. As illustrated in Figure 18, the V-l characteristic changed on some of the devices, but returned to its original value after applying a second or third pulse. Is this an inversion of the aging process? Time and temperature have very similar effects. To be conservative, peak pulse limits have been established which, in many cases, have been exceeded manyfold without harm to the device. This does not mean that established limits should be ignored, but rather, viewed in perspective of the definition of a failed device. A failed device shows a ±10 percent change of the V-l characteristic at the 1mA point. Zener diodes, on the other hand, fail suddenly at predictable power and energy levels. Bx20|isWAVEV31CP2 H f 0123456789 10 NUMBER OF PULSES FIGURE 18. 250A PULSE-WITHSTAND CAPABILITIES Failure Mode Varistors fail short, but can also explode when energy is excessive, resulting in an open circuit. Because of the large peak pulse capabilities of varistors, these types of failure are quite rare for properly selected devices. 12-41 Application Note 9307 Zeners, on the other hand, can fail either short or open. If the pellet is connected by a wire, it can act as a fuse, disconnecting the device and resulting in an open circuit. Designers must analyze which failure mode, open or short, is preferred for their circuits. When a device fails during a transient, a short is preferred, since it will provide a current path bypass and continued to protect the sensitive components. On the other hand, if a device fails open during a transient, the remaining energy ends up in the sensitive components that were supposed to be protected. If the energy is already dissipated, the circuit will now operate without a suppressor and the next transient, or the next few transients, will denigrate the equipment. Another consideration is a hybrid approach, making use of the best features of both types of transient suppressors (Figure 19). input— f-v/v-f— ~ T~ rrYYV T — VARISTOR \X ZENER VARISTOR \A ZENER FIGURE 19. HYBRID PROTECTION USING VARISTORS, ZENERS, R AND L Capacitance Depending on the application, transient suppressor capacitance can be a very desirable or undesirable feature compared to zener diodes. Varistors have a higher capacitance. In DC circuits, capacitance is desirable: the larger the better. Decoupling capacitors are used on IC supply voltage pins and can in any cases be replaced by varistors, providing both the decoupling and transient voltage clamping functions. The same is true for filter connectors where the varistor can perform the dual functions of providing both filtering and transient suppression. There are circuits, however, where capacitance is less desir- able, such as high frequency digital or some analog circuits. As a rule, the source impedance of the signal and the frequency as well as the capacitance of the transient suppressor should be considered (Figure 20). The current through C P is a function of dv/dt and the distortion is a function of the signal's source impedance. Each case must be evaluated individually to determine the maximum allowable capacitance. INPUT SIGNAL OUTPUT SIGNAL JUL FIGURE 20. SOURCE IMPEDANCE (R s ) AND PARASITIC CAPACITANCE (C p ) Response to Radiation For space applications, an extremely important property of a protection device is its response to imposed radiation effects. Electron Irradiation Figure 21 represents MOV and zener devices exposed to electron irradiation. The V-l curves, before and after test, are shown. The MOV is virtually unaffected, even at the extremely high dose of 10 8 rads, while the zener shows a dramatic increase in leakage current. 100 80 60 20 10 s HARRIS MOV 4 * —t * ZENER ■ 1 r -PRE -10 a R ■EST ADS, 18M !V ELECT! IONS 10 6 10* CURRENT (A) 10 2 FIGURE 21. RADIATION SENSITIVITY OF MOV AND ZENER DEVICES Neutron Effects A second MOV-zener comparison was made with respect to neutron fluence. The selected devices were equal in area. Figure 22 shows the clamping voltage response of the MOV and the zener to neutron irradiation as high as 1 1 5 N/cm 2 . In contrast to the large change in the zener, the MOV is unaltered. At higher currents where the MOVs clamping voltage is again unchanged, the zener device clamping voltage increases by as much as 36 percent. FIGURE 22. VOLTAGE CURRENTS CHARACTERISTIC RESPONSE TO NEUTRON IRRADIATION FOR MOV AND ZENER DIODE DEVICES Counterclockwise rotation of the V-l characteristics is observed in silicon devices at high neutron irradiation levels. In other words, leakage increases at low current levels and clamping voltage increases at higher current levels. 12-42 Application Note 9307 The solid and open circles for a given fluence represent the high and low breakdown currents for the sample of devices tested. A marked decrease in current (or energy) handling capability with increased neutron fluence should be noted. The failure threshold level of silicon semiconductor junctions is further reduced when high or rapidly increasing currents are applied. Junctions develop hot spots, which enlarge until a short occurs if current is not limited or quickly removed. The characteristic voltage current relationship of a PN- Junction is shown in Figure 23. At low reverse voltage, the device will conduct very little current (the saturation current). At higher reverse voltage V B0 (breakdown voltage), the current increases rapidly as the electrons are either pulled by the electric field (zener effect) or knocked out by other electrons (avalanching). A further increase in voltage causes the device to exhibit a negative resistance characteristic leading to a secondary breakdown. This manifests itself through the formation of hotspots, and irreversible damage decreases under neutron irradiation for zeners, but not for zinc oxide varistors. SATURATION CURRENT BREAKDOWN VOLTAGE REDUCTION IN FAILURE STRESSHOLD BY RADIAL SECONDARY BREAKDOWN FIGURE 23. VOLTAGE CURRENTS CHARACTERISTIC OF PN-JUNCTION Gamma Radiationf 71 Radiation damage studies were performed on specified varistors. Emission spectra and V-l characteristics were collected before and after irradiation with 10 6 rads Co 60 gamma radiation. Both show no change, within experimental error, after irradiation. Mechanical Strength After sintering, the varistor becomes a strong, rugged ceramic material. As with all ceramic materials, it has high compressive strength and lower tensile or shear strength. An experiment was performed to demonstrate the strength of the varistor material when used in the tubular form. Results are shown in Table 2. P1 and P2 represent maxi- mum pressures applied before fracture. Directions of applied stresses are shown in Figure 24. TABLE 2. VARISTOR MATERIAL STRENGTH PART SIZE P1 P2 20A 100lbs 30lbs 20B 1 0Olbs 141bs 22B 100lbs 14lbs 1111 FIGURE 24. APPLIED STRESSES Conclusions Connector pin varistors provide a unique way to install surge protection in electronic systems without the bulkiness of some approaches. The tubular form of this varistor gives a relatively large area for conducting surge current, with an inherent mass for dissipating electrical heat energy. The rugged body physi- cally resembles passive components; but, because it is a semiconductor device, response time is very fast. The lead- less form reduces the voltage overshoot that can be caused by lead inductance. Also, the device has a high degree of inherent radiation hardness. Connector pin varistors divert surge currents to the outside surface of the "black box" hous- ing, not to printed board runs feeding sensitive circuits, thereby helping to avoid or reduce surge coupling side effects. References [1] Harris Corporation, Transient Voltage Suppression Devices," Fifth Edition, 400.3, September, 1989. [2] Sebald R. Korn, The New Low Voltage GE-MOV Varistor (For Protection of 5 VDC and Below). Application Note No. 200.91 by General Electric Application Engineering. [3] D. M. Tasca and J. C. Peden, Technical Information Series No. 73SD252 EMT/Power Transient Suppression, Gen- eral Electric Re-entry & Environmental Systems Division. D. M. Tasca and J. C. Peden, Technical Information Series No.73SD23G Subnanosecond Rise Time Pulse Response and Clamping Voltage Characteristics of GE- MOV and Transzorb, General Electric Space Division. [4] Lionel M. Levinson and H. R. Philipp, "AC-Properties of Metal Oxide Varistors," Journal of Applied Physics, Vol. 47, No. 3, March, 1976. [5] Lionel M. Levinson and H. R. Philipp, "High-Frequency and High-Current Studies of Metal Oxide Varistors," Journal of Applied Physics, Vol. 47, No. 3, March, 1976. [6] Low Temperature Admittance Spectroscopy of Zinc Oxide Varistors (internal GE report). [7] EMP Engineering and Design Principles, Sixth Printing October, 1984, Bell Telephone Laboratories, Inc. [8] Data Book 1980 - 1981 . General Semiconductor Indus- tries, Inc. 12-43 Harris Semiconductor NO. AN9308.1 March 1995 Harris MOVs Voltage Transients and Their Suppression Author: Martin P. Corbett Introduction The increasing usage of sensitive solid state devices in modem electrical systems, particularly computers, communi- cations systems and military equipment, has given rise to concerns about system reliability. These concerns stem from the fact that the solid state devices are very susceptible to stray electrical transients which may be present in the distri- bution system. The initial use of semiconductor devices resulted in a number of unexplained failures. Investigation into these failures revealed that they were caused by transients, which were present In many different forms in the system. Transients in an electrical circuit result from tile sudden release of previously stored energy. The severity of, and hence the damage caused by transients depends on their frequency of occurrence, the peak transient currents and voltages present and their waveshapes. In order to adequately protect sensitive electrical systems, thereby assuring reliable operation, transient voltage sup- pression must be part of the initial design process and not simply included as an afterthought. To ensure effective tran- sient suppression, the device chosen must have the capabil- ity to dissipate the impulse energy of the transient at a sufficiently low voltage so that the capabilities of the circuit being protected are not affected. The most successful type of suppression device used is the metal oxide varistor. Other devices which are also used are the zener diode and the gas-tube arrestor. The Transient Environment The occurrence rate of surges varies over wide limits, depending on the particular power system. These transients are difficult to deal with, due to their random occurrences and the problems in defining their amplitude, duration and energy content. Data collected from many independent sources have led to the data shown in Figure 1 . This predic- tion shows with certainty only a relative frequency of occur- rence, while the absolute number of occurrences can be described only in terms of low, medium or high exposure. This data was taken from unprotected circuits with no surge suppression i a z Q LU UJ u < X to LU UJ DC Q < to LU 00 >■ < en LL LU O a H to to LU Hi a tc LT o SU UJ o OF UR K to LU m 1 10* HIGH EXPOS URE \ Ml EXPO DIUM > SURE — (SEE NO C rE) SPAR F CLEAR KOVER ANCES — ■ E LOV XPOSUR s 1 2 5 SURGE CREST (kV) NOTE: In some locations, sparkover of clearances may limit the overvoltages. FIGURE 1. RATE OF SURGE OCCURRENCES vs VOLTAGE LEVEL AT UNPROTECTED LOCATIONS The low exposure portion of the graph Is derived from data collected in geographical areas known for low lightning activ- ity, with little load switching activity. Medium exposure sys- tems are geographical areas known for high lightning activity, with frequent and severe switching transients. High exposure areas are rare, but real systems, supplied by long overhead lines and subject to reflections at line ends, where the characteristics of the installation produce high sparkover levels of the clearances. Investigations into the two most common exposure levels, low and medium, have shown that the majority of surges occurring here can be represented by typical waveform shapes (per ANSI/IEEE C62.41-1980). The majority of surges which occur in indoor low voltage power systems can be modeled to an oscillatory waveform (see Figure 2). A surge impinging on the system excites the natural resonant frequencies of the conductor system. As a result, not only are the surges oscillatory but surges may have different amplitudes and waveshapes at different locations in the sys- tem. These oscillatory frequencies range from 5kHz to 500kHz with 100kHz being a realistic choice. Copyright © Harris Corporation 1995 12-44 Note 9308 0.9V PEAK VpEAK 0.1 V PEAK 60% OF Vp EAK FIGURE 2. 0.5ms - 100kHz RING WAVE (OPEN CIRCUIT VOLT- AGE) In outdoor situations the surge waveforms recorded have been categorized by virtue ot the energy content associated with them. These waveshapes involve greater energy than those associated with the indoor environment. These waveforms were found to be unidirectional in nature (see Figure 3). °-9V PEAK 0-3V PEAK T, x 1.67 c 1.2^s FIGURE 3A. OPEN-CIRCUIT WAVEFORM "•9 'peak T 2 x 1 .25 ■ 8ms FIGURE 3B. DISCHARGE CURRENT WAVEFORM FIGURE 3. UNIDIRECTIONAL WAVESHAPES (OUTDOOR LOCATIONS) Transient Energy and Source Impedance Some transients may be intentionally created in the circuit due to inductive load switching, commutation voltage spikes, etc. These transients are easy to suppress since their energy content is known. It is the transients which are gener- ated external to the circuit and coupled into it which cause problems. These can be caused by the discharge of electro- magnetic energy, e.g., lightning or electrostatic discharge. These transients are more difficult to identify, measure and suppress. Regardless of their source, transients have one thing in common - they are destructive. The destruction potential of transients is defined by their peak voltage, the follow-on current and the time duration of the current flow, that is: E = Jvc(t).|(t)dt o where: E = Transient energy I = Peak transient current Vc = Resulting clamping voltage t = Time x = Impulse duration of the transient It should be noted that considering the very small possibili- ties of a direct lightning hit it may be deemed economically unfeasible to protect against such transients. However, to protect against transients generated by line switching, ESD, EMP and other such causes is essential, and if ignored will lead to expensive component and/or system losses. The energy contained in a transient will be divided between the transient suppressor and the line upon which it is travelling in a way which is determined by their two impedances. It is essential to make a realistic assumption of the transient's source impedance in order to ensure that the device selected for protection has adequate surge handling capability. In a gas-tube arrestor, the low impedance of the arc after sparkover forces most of the energy to be dissipated elsewhere - for instance in a power-follow current-limiting resistor that has to be added in series with the gap. This is one of tile disadvantages of the gas-tube arrestor. A voltage clamping suppressor (e.g., a metal oxide varistor) must be capable of absorbing a large amount of transient surge energy. Its clamping action does not involve the power-follow energy resulting from the short-circuit action of the gap. The degree to which source impedance is important depends largely on the type of suppressor used. The surge suppressor must be able to handle the current passed through them by the surge source. An assumption of too high an impedance (when testing the suppressor) may not subject it to sufficient stresses, while the assumption of too low an impedance may subject it to unrealistically large stress; there is a trade off between the size/cost of the sup- pressor and the amount of protection required. In a building, the source impedance and the load impedance increases from the outside to locations well within the inside of the building, i.e., as one gets further from the service 12-45 Application Note 9308 entrance, the impedance increases. Since the wire in a structure does not provide much attention, the open circuit voltages show little variation. Figure 4 illustrates the application of three categories to the wiring of a power system. These three categories represent the majority of locations from the electrical service entrance to the most remote wall outlet. Table 1 is intended as an aid in the selection of surge suppressors devices, since it is very difficult to select a spe- cific value of source impedance. Category A covers outlets and long branch circuits over 30 feet from category B and those over 60 feet from category C. Category B is for major feeders and short branch circuits from the electrical entrance. Examples at this location are bus and feeder systems in industrial plants, distribution panel devices, and lightning systems in commercial build- ings. Category C applies to outdoor locations and the electri- cal service entrance. It covers the service drop from pole to building entrance, the run between meter and the distribu- tion panel, the overhead line to detached buildings and underground lines to well pumps. TABLE 1. SURGE VOLTAGES AND CURRENTS DEEMED TO REPRESENT THE INDOOR ENVIRONMENT AND RECOMMENDED FOR USE IN DESIGNING PROTECTIVE SYSTEMS LOCATION CATEGORY CENTER COMPARABLE TO IEC 664 CATEGORY IMPULSE ENERGY (JOULES) DEPOSITED IN A SUPPRESSOR WITH CLAMPING VOLTAGE WAVEFORM MEDIUM EXPOSURE AMPLITUDE TYPE OF SPECIMEN OR LOAD CIRCUIT CIRCUIT 500V 1000V A. Long branch circuits and outlets II 0.5|iS - 100kHz 6kV High Impedance (Note 1) (120V Sys.) (240V Sys.) 200A Low Impedance (Note 2) 0.8 1.6 B. Major feeders short branch circuits, and load center III 1 .2/50ms 6kV High Impedance (Note 1) 8/20^is 3kA Low Impedance (Note 2) 40 80 0.5ms - 100kHz 6kV High Impedance (Note 1) 500A Low Impedance 2 4 NOTES: 1 . For high-impedance test specimens or load circuits, the voltage shown represents the surge voltage. In making simulation tests, use that value for the open-circuit voltage of the test generator. 2. For low-impedance test specimens or load circuits, the current shown represents the discharge current of the surge (not the short-circuit current of the power system). In making simulation tests, use that current for the short-circuit current of the test generator. 3. Other suppressors which have different clamping voltages would receive different energy levels. 12-46 Application Note 9308 i TRANSFORMER j> METER OUTBUILDING A B C Outlets and long branch circuits. All outlets at more than 10m (30ft.) from Category B. All outlets at more than 20m (60ft.) from Category C. Feeders and short branch circuits Distribution Panel Devices Bus and feeder in industrial plants Heavy appliance outlets with "short" con- nections to service entrance Lighting systems in large buildings Outside and service entrance Service drop from pole to building. Run between meter and panel. Over- head line to detached building. Under- ground line to well pump. Transient Suppression The best type of transient suppressor to use depends on the intended application, bearing in mind that in some cases both primary and secondary protection may be required. It is the function of tile transient suppressor to, in one way or another, limit the maximum instantaneous voltage that can develop across the protected load. The choice depends on several factors, but the decision is ultimately a trade-off between the cost of the suppressor and the amount of protection needed. The time required for a transient suppressor to begin functioning is extremely important when it is used to protect sensitive components. If the suppressor is slow acting and a fast-rise transient spike appears on the system the voltage across the protected load can rise to damaging levels before suppression begins. On AC power lines the best type of suppression to use is a metal oxide varistor. Other devices occasionally used are the zener diode and the gas-tube arrestor. Gas-Tube Arrestors This is a suppression device which finds most of its applica- tions in telecommunication systems. It is made of two metal- lic conductors usually separated by 10mils to 15mils encapsulated in a glass envelope. This glass envelope is pressurized and contains a number of different gases. One disadvantage of this device arises from the possibility of seal leakage and the resulting loss of protection. Also, in a gas- tube arrestor, the low impedance of the arc after sparkover forces most of the energy to be dissipated elsewhere. This requires additional components in the system, for instance a power-follow current-limiting resistor that has to be added in series with the gap. Zener Diodes One type of clamp-action device used in transient suppres- sion is the zener diode. When a voltage of sufficient ampli- tude is applied in the reverse direction, the zener diode is 12-47 ing across the diode is therefore called the reverse ava- lanche or zener voltage. When a transient propagates along the line with a voltage exceeding the reverse-based voltage rating of the diode, the diode will conduct and the transient will be clamped at the zener voltage. This clamping voltage is lower than that of an equivalent varistor. Some manufacturers have claimed that the response time of a zener diode is 1ps to 2ps. This is impossible according to the laws of physics, since a signal traveling at the speed of light in vacuum, the fastest speed in the universe, would require about 50ps to transverse the length of the plastic package of the diode. In practice, the speed of response is determined by the parasitic inductance of the package and the manner in which the device is con- nected via its leads. Although zener diodes can provide tran- sient protection, they cannot survive significant instantaneous power surges. Larger diodes can be used to increase the power rating, but this is oniy at the expense of increased costs. Also, the maximum tolerable surge current for a zener diode in reverse breakdown is small when com- pared to tolerable surge currents for varistors. Due to the fact that there is only the p-n junction in a zener diode, it will need to have some additional heat sinking in order to facili- tate the rapid build-up of heat which occurs in the junction after it has encountered a transient. Metal Oxide Varistor As the name suggests, metal oxide varistors (MOV) are vari- able resistors. Unlike a potentiometer, which is manually adjusted, the resistance of a varistor varies automatically in response to changes in voltages appearing across it. Varis- tors are a monolithic device consisting of many grains of zinc oxide, mixed with other materials, and compressed into a single form. The boundaries between individual grains can be equated to p-n junctions with the entire mass represented as a series-parallel diode network. When a MOV is biased, some grains are forward biased and some are reverse biased. As the voltage is increased, a growing number of the reversed biased grains exhibit reverse avalanche and begin to conduct. Through careful control in manufacturing, most of the nonconducting p-n junctions can be made to avalanche at the same voltage. on physical characteristics of the MOV and the wave shape of the current pulse driven through it by the voltage spike. Experimental work has shown the response time to be in the 500 picosecond range. One misconception about varistors is that they are slow to respond to rapid rise transients. This "slow" response is due to parasitic inductance in the package and leads when the varistor is not connected with minimal lead length. If due consideration is given to these effects in its installation, the MOV will be more than capable of suppressing any voltage transients found in the low voltage ac power system. The MOV has many advantages over the zener diode, the greatest of which is its ability to handle transients of much larger energy content. Because it consists of many p-n junc- tions, power is dissipated throughout its entire bulk, and unlike the zener, no single hot spot will develop. Another advantage of the MOV is its ability to survive much higher instantaneous power. Summary When designing circuits of the complex nature seen in todays electrical environment, the initial design must incor- porate some form of transient voltage surge suppression. The expense of incorporating a surge protection device in a system is very low when compared with the cost of equip- ment downtime, maintenance and lost productivity which may result as a consequence of not having protection. When selecting surge suppressors for retrofit to an existing design, one important point to remember is that the location of the load to be protected relative to the service entrance is as important as the transient entrance which may be present in an overvoltage situation. Bibliography An American National Standard/IEEE Guide for Surge Voltages in Low Voltage AC Power Circuits, C62.41-1980. Harris Semiconductor, Transient Voltage Suppression Devices, DB450. Korn, Sebald, Voltage Transients and Power Conversion Equipment, GE. 12-48 Harris Semiconductor NO. AN9310 March 1995 Harris MOVs Surge Suppression Technologies Advantages and Disadvant (MOVs, SADs, Gas Tubes, Filters and Transformers) Author: Martin P. Corbett capability to dissipate the impulse energy of the transient at Synopsis Protection on the low voltage AC mains system from transient overvoltages is now a fundamental power quality concern. The use of correctly selected and installed surge protectors have a long and proven history of successful field performance. The expected transient environment is addressed, along with various types of surge suppression components which are available. Advantages and disadvan- tages of isolator, crowbar and clamping type surge suppres- sors are discussed. Competitive evaluations are reported and some recommendations and guidelines for the selection of the correct type of device to be used are given. Introduction The increasing use of semiconductors and other solid state components in modern electrical systems has resulted in a growing awareness about system reliability. This is a consequence of the fact that solid state devices are very susceptible to stray electrical transients which may be present in the low voltage AC distribution system. The initial use of semiconductors resulted in a large number of unexplained failures. Investigation into these failures revealed that they were caused by a number of diverse overvoltage conditions which were present in the distribution system. Transient voltages result from the sudden release of previously stored energy from overstress conditions such as lightning, inductive load switching, electromagnetic pulses or electrostatic discharges. The severity of, and hence the damage caused, by the transient depends on their frequency of occurrence, their peak values and their waveshapes. Electrical overvoltages on AC mains can cause either permanent deterioration, or temporary malfunctions in electronic components and systems. Protection from transients can be obtained by using specially designed components which will, either limit the magnitude of the transient using a large series impedance or by diverting the transient using a low value shunt impedance. A prudent designer will consider the need for transient protection in the early stages of the design. Too many times it has been necessary to retrofit existing equipment with transient suppressors. This is expensive in terms of field failures, customer downtime and potential loss of business. In some systems retrofitting becomes cumbersome, as the space required was not planned for in the initial design. The device selected as the system protector must have the a sufficiently low voltage so that the capabilities of the system being protected are not affected. Problem Definition (The Transient Environment)^ •* 3 - "i Primarily the problem is that of the enigmatic presence of overvoltage surges, above the normal system voltage. Over- voltages are sometimes explainable or sometimes they just mysteriously appear in the electrical system; they take the form of disturbances, notches, swells, sags, brownouts, outages or combinations of the above and are generically known as transients. A common result of encountering these overvoltages is the early failure of semiconductor components and other sensitive electrical components. An equally serious effect is the loss of control in solid-state logic systems that may think surges are legitimate signals and thus endeavor to react to them. Numerous studies have been performed which indicate that the causes of the surges in an electrical system can be attributed to one of the following causes: • Lightning • Opening or closing of switch contacts under load • Propagation of surges through transformers • Severe load changes in adjacent systems • Power line fluctuations and pulses • Short circuits or blown fuses The power system is made up of a large network of cross connected transmission lines. This power system is often interfered with by transients originating from one of the aforementioned sources. Transients caused by lightning can inject very high currents into the system. These lightning strikes, usually to the primary transmission lines, may result in coupling to the secondary line through mutual inductive or capacitive coupling. Even a lightning hit that misses the line can induce substantial voltage onto the primary conductors, triggering lightning arresters and creating transients. Man-made switching transients can be of a lesser, but more frequent threat. Switching of the power grid can cause transients which may damage down line equipment. The use of thyristors in switching circuits or power control can also create such transients. Copyright 10J Infrequent <125V < 320ms Inductive-load switching transient <1J Often 300V to +80V 200ms Alternator field decay <1J Each Turn-Off -100V to -40V 90ms Ignition pulse, battery discon- nected <0.5J < 500Hz Several Times in Vehicle Life <75V 1ms Mutual coupling in harness <1J Often <200V 15ns Ignition pulse, normal <0.001J < 500Hz Continuous 3V Accessory noise <1.5V 50Hz to 10kHz Transceiver feedback =20mV R.F. The achievement of maximum transient protection involves many factors. First, consequences of a failure should be determined. Current limiting impedances and noise immuni- ties need to be considered. The state of the circuit under transient conditions (on, off, unknown) and the availability of low cost components capable of withstanding the transients are other factors. Furthermore, the interaction of other parts of the automotive electrical system with the circuit under transient conditions may require definition. Suppressor Applications [31 The sensitive electronics of the automobile need to be protected from both repetitive and random transients. In an environment of random transients, the dominating constraints are energy and clamping voltage vs standby power dissipation. For repetitive transients, transient power dissipation places an additional constraint on the choice of suppression device. It must also be noted that the worst case transient scenarios, load dump and jump start, place conflicting constraints on the automotive suppressor. The high energy content of the load dump transient must be clamped to a worst case volt- age of 40V, while the leakage current/power dissipation drawn under a jump start condition must also be kept to a minimum. A centrally located suppressor is the principal transient suppression device used in most automobiles. It is connected directly across the main power supply line without any intervening load resistance. It must be capable of absorbing the entire available load dump energy, and must also withstand the full jump start voltage. To be cost effective, it is usually located in the most critical electronic module. Additional secondary suppression is also employed at other locations in the system for further suppression and to control locally generated transients. As previously mentioned, the maximum load dump energy available to the central suppressor depends on a combina- tion of the alternator size and the loads that share the surge current and energy which are thus generated. It must be remembered that there are many different automotive electronic configurations which result in a variety of diverse load dumps. MultiLayer Transient Voltage Surge Suppressor (AUML)t 4 ' 5 1 The new automotive multilayer (AUML) transient voltage suppressor is a voltage dependent, nonlinear device. It has an electrical behavior similar to that of a back-to-back zener diodes and it is inherently bidirectional. It offers protection from transients in both the forward and reverse directions. When exposed to high voltage transients, the AUML under- goes a nonlinear impedance change which is many orders of magnitude, from approximately 10 9 to 10£1. The crystalline structure of the AUML transient voltage suppressor consists of a matrix of fine, conductive grains separated by uniform grain boundaries, forming P-N junctions (Figure 3). These boundaries are responsible for blocking conduction at low voltages, and are the source of 12-59 ^uiiuuuuon 01 ine transient energy taKes place between the millions of P-N junctions present in the device. The uniform crystalline grains act as heat sinks for the energy absorbed by the device under a transient condition, and ensures an even distribution of the transient energy (heat) throughout the device. This even distribution results in enhanced transient energy capability and long term reliability. FIGURE 3. AUML TRANSIENT VOLTAGE SUPPRESSOR The AUML is constructed by forming a combination of alter- nating electrode layers and semiconducting ceramic layers into a rectangular block. Each alternate layer of electrode material, separated by ceramic semiconducting material, is connected to opposite end terminations of the device. SEMICONDUCTING CERAMIC inner ^ ;nd ELECTRODES ■ TERMINATION FIGURE 4. AUML INNER CONSTRUCTION The paralleled arrangement of the inner electrode layers represents significantly more active surface area than the small outline of the package may suggest (Figure 4). This increased active surface area, combined with an interdigi- tated block formation, results in proportionally higher peak energy capability. The AUML surge suppressor is a surface mountable device that is much smaller in size than the components it is designed to protect. The present size offerings for suppres- sion in the automotive environment are "1210" (0.120 x (0.220 x 0.200 inches). The correct device to use depends on the location of the suppressor in the overall electronics system. Device Ratings and Characteristics Package Outline The present size offerings of the AUML series are the indus- try 2220, 1812 and 1210 standard form factors. Since the AUML device is inherently bidirectional, symmetrical orienta- tion for placement on a printed circuit board is not a concern. Its robust construction makes it ideally suitable to endure the thermal stresses involved in the soldering, assembling and manufacturing steps involved in surface mount technology. The AUML device is inherently passivated by means of the fired ceramic material. They will not support combustion and are thus immune to the risk of flammability which may be present in the plastic or epoxy molded diode devices. Load Dump Energy Capability The most damaging classification of transients an automo- bile must survive is a load dump discharge occurrence. A load dump transient occurs when the alternator load in the automobile is abruptly reduced and the battery clamping effect is thus removed. The worst case scenario of the load dump occurs when the battery is disconnected while operating at full rated load. The resultant load dump energy handling capability serves as an excellent figure of merit for the AUML suppressor. Standard load dump specifications require a device capabil- ity of 10 pulses at rated energy, across a temperature range of -40°C to +125°C. This capability requirement is well within the ratings of all of the AUML series. Due to the assortment of electronic applications in an automotive circuit, there is a need for a wide range of surge suppressors. The transient environment can generally be divided into three distinct sections and there will be a need for a different type of suppressor within each section. The 2220 size was designed for operation in the primary transient area, i.e. directly across the alternator. The 1812 size for secondary protection and the 1210 size for tertiary protection. A typically load dump transient results in an energy discharge of approximately 100J (depending on the size of the alternator). The deciding factor in the selection of the correct size suppressor is the amount of energy which is dissipated in the series and parallel loads in the circuit. The higher the impedance between the battery and the system requiring suppression, the smaller is the suppressor required. Random samples of the 1210, 1812 and 2220 devices were subjected to repetitive load dump pulses at their rated energy level. This testing was performed across a tempera- ture spectrum from -40°C to +125°C. This temperature range simulates both passenger compartment and under the hood operation. There was virtually no change in the device characteristics of any of the units tested (Figure 5). 12-60 Application Note 9312 1 35. < >30. 5 25. 1210 = 3J 3 4 5 6 7 8 NUMBER OF LOAD DUMP PULSES -r- 10 FIGURE 5. LOAD DUMP PULSING OVER A TEMPERATURE RANGE OF - 55°C to +125°C Further testing on the AUML series has resulted in the extension the number of load dump pulses, at rated energy, which are applied to the devices. The reliability information thus generated gives an indication of the inherent capability of the series of devices. The V18AUMLA1210 sample has been subjected to over 2000 pulses at its rated energy of 3J; the V18AUMLA1812 sample over 1000 times at 6J. The V18AUMLA2220 sample has been pulsed at 25J over 300 times (Figure 6). In all cases there has been little or no change in the device characteristics. ~i r 60 90 120 150 180 210 240 270 300 NUMBER OF LOAD DUMP PULSES FIGURE 6. REPETITIVE LOAD DUMP PULSING AT RATED LOAD DUMP ENERGY As previously discussed, the very high energy absorption capability of the AUML suppressor series is achieved by means of a new, highly controlled manufacturing process. This new multilayer technology ensures that a large volume of suppressor material, with an interdigitated layer construc- tion, is available in an extremely small package. Unlike equivalent rated silicon TVS diodes, all of the AUML device package is available to act as an effective, uniform heat sink. Hence, the peak temperatures generated by the load dump transient are evenly dissipated throughout the complete device. This even energy dissipation ensures that there are lower peak temperatures generated at the P-N grain bound- aries of the AUML suppressor. Experience has shown that while the effects of a load dump transient are of real concern, its frequency of occurrence is much less than that of localized low energy inductive spikes. Such low energy spikes may be generated as a result of motors turning on and off, from ESD occurrences, or from any number of other sources. It is essential that the suppres- sion technology selected also has the capability to suppress such transients. Testing on the V18AUMLA2220 has shown that after being subjected to a repetitive energy pulse of 2J, over 6000 times, no characteristic changes have occurred (Figure 7). I 1000 n 1 1 r 2000 3000 4000 5000 NUMBER OF PULSES FIGURE 7. REPETITIVE ENERGY TESTING OF THE V1 8AUM- LA2220 AT LOW ENERGY LEVELS Clamping Voltage The clamping voltage of a suppressor is the peak voltage appearing across the device when measured under condi- tions of a specified current pulse waveform. The industry recommended waveform for clamping voltage is the 8/20us pulse which has been endorsed by UL, IEEE and ANSI. The maximum clamping voltage of the AUML should be below the system or component failure level. Shunt type suppressors like the AUML are used in parallel to the systems they protect. Their effectiveness can be increased by understanding the important influence that source and line impedance play in the overall system (Figure 8). ( ) V SOURCE Z SUPPRESSOR l/\ (CLAMPING jt-I VOLTAGE) T t SYSTEM TO BE PROTECTED FIGURE 8. VOLTAGE DIVISIONS BETWEEN SOURCE, LINE AND SUPPRESSOR IMPEDANCE To obtain the lowest clamping voltage (V c ) possible, it is desirable to use the lowest suppressor impedance (Z SUPPRESS or) and the highest line impedance (Z UNE ). The suppressor impedance is an inherent feature used to select the device, but the line impedance can become an important factor in selecting the location of the suppressor L>y adding resistances or inductances in series. V SUPPRESSOR * V SOURCE Z SUPPRESSOR + Z LINE + Z SOURCE 12-61 Application Note 9312 Speed of Response The clamping action of the AUML suppressor depends on a conduction mechanism similar to that of other semiconduc- tor devices (i.e. the P-N Junction). The apparent slow response time often associated with transient suppressors is due to parasitic inductance in the package and leads of the device, and is independent of the conducting material. The most critical element affecting the response time of a suppressor is the inductance of the lead material and hence the lead length. The AUML suppressor is a surface mount device with no leads or external packaging, and thus, virtually zero inductance. The response time of a AUML surge suppressor is in the 1ns to 5ns range, which is more than sufficient for the transients which are encountered in the automotive environment. Temperature Effects In the off-state (leakage) region of the multilayer suppressor, the device characteristics approach a linear (ohmic) relationship and shows a temperature dependent affect. In this region the suppressor is in a very high resistance mode (approaching 10 Q) and appears as a near open circuit. Leakage currents at maximum rated voltage are in the low microamp range. When suppressing transients at higher currents (at and above the ten milliamp range), the AUML suppressor approaches a near short-circuit. In this region the characteristics of the AUML are virtually temperature independent. The clamping voltage of a multilayer transient voltage suppressor are the same at -55°C and +125°C (Figure 9). CURRENT (A) FIGURE 9. TYPICAL V - 1 CHARACTERISTICS OF THE V18AUMLA2220 AT -40°C, +25°C, +85°C AND +125°C Soldering Recommendations for Multilayer Surge Suppressors™ When soldering all surface mount components onto printed circuit boards there are certain materials, parameters and processes which must be considered. These include: 1 . Printed Circuit Board Material 2. Flux used 3. Land Pad Size 4. Soldering Methods 4.1 Infrared Reflow Solder 4.2 Vapor Phase Solder 4.3 Wave Solder 5. Cleaning Methods and Fluids Employed Substrates There are a wide choice of substrate materials available for use as printed circuit boards in a surface mount application. The main factors which determine the choice of material to use are: 1 . Electrical performance 2. Size and weight limitations 3. Thermal characteristics 4. Mechanical characteristics 5. Cost When choosing a substrate material, the coefficient of ther- mal expansion for the ML surface mountable suppressor of 6ppm/°C is an important consideration. Non-organic materi- als (ceramic based substrates), like aluminum or beryllia, which have coefficients of thermal expansion of 5ppm - 7ppm/°C, are a good match. Table 2 below outlines some of the other materials used, and also there more important properties pertinent to surface mounting. While the choice of substrate material should take note of the coefficient of expansion of the devices, this may not be the determining factor in whether a device can be used or not. Obviously the environment of the finished circuit board will determine what level of temperature cycling will occur. It is this which will dictate the criticality of the match between device and printed circuit board. Currently for most applica- tions the ML series use FR4 boards without issue. TABLE 2. SUBSTRATE MATERIAL PROPERTIES SUBSTRATE STRUCTURE MATERIAL PROPERTIES GLASS TRANSITION TEMPERATURE (°C) XY COEFFICIENT OF THERMAL EXPANSION (PPM/°C) THERMAL CONDUC- TIVITY (W/M°C) Epoxy Fiberglass FR4 125 14 - 18 0.16 Polyamide Fiberglass 250 12 - 16 0.35 Epoxy Aramid Fiber 125 6-8 0.12 Fiber/Teflon Laminates 75 20 0.26 Aluminum- Beryllia (Ceramic) Not Available 5-7 21.0 12-62 Application Note 9312 Fluxes Fluxes are used for the chemical cleaning of a substrate surface. They will remove any surface oxides, and will also prevent reoxidation. They can contain active ingredients such as solvents for removing soils and greases. Nonactivated fluxes ("FT type) are relatively effective in reducing oxides of copper, nickel or palladium/silver metallizations and are recommended for use with the Harris surface mount suppressor range. Mildly activated fluxes ("RMA" type) have natural and synthetic resins, which reduce oxides to metal or soluble salts. These "RMA" fluxes are generally not conductive nor corrosive at room temperature and are the most commonly used in the mounting of electronic components. The "RA" type (fully activated) fluxes are corrosive, difficult to remove, and can lead to circuit failures and other problems. Other nonresin fluxes depend on organic acids to reduce oxides. They are also corrosive after soldering and also can damage sensitive components. Water soluble types in particular must be thoroughly cleaned from the assembly. Environmental concerns, and associated legislation, has led to a growing interest in fluxes with residues that can be removed with water or water and detergents (semiaqueous cleaning). Many RMA fluxes can be converted to water soluble forms by adding saponifers. There are detergents and semiaqueous cleaning apparatus available that effec- tively remove most RMA type fluxes. Semiaqueous cleaning also tends to be less expensive than solvent cleaning in operations where large amounts of cleaning are needed. For the Harris Semiconductor range of surface mount varistors, nonactivated "R" type fluxes such as Alpha 100 or equivalent are recommended. Land Pad Patterns Land pad size and patterns are one of the most important aspects of surface mounting. They influence thermal, humid- ity, power and vibration cycling test results. Minimal changes (even as small as 0.005 inches) in the land pad pattern have proven to make substantial differences in reliability. This design /reliability relationship has been shown to exist for all types of designs such as in J-lead, quadpacks, chip resistors, capacitors and small outline integrated circuit (SOIC) packages. Optimum and tested land pad dimensions are provided for some surface mounted devices along with formulas which can be applied to different size varistors. Figure 10 gives optimum land patterns for the direct mount multilayer devices, while Table 3 outlines the optimum size of the land pad for each device size. TABLE 3. RECOMMENDED MOUNTING PAD OUTLINE -«- L (M + 2) -» W + 0.010 OR 0.020W T : M LT SUPPRESSOR SIZE DIMENSION T + M L-2M W+0.01 OR 0.02*W 1206 1.65 1.85 2.62 1210 1.85 1.85 3.73 1812 1.85 3.20 4.36 2220 1.84 4.29 6.19 Solder Materials and Soldering Temperatures No varistor should be held longer than necessary at an elevated temperature. Exceeding the temperature and time limits can result in excessive leakage and alterations of the l-V characteristics. 250 " o 210 " LU rx 230 " i ir 220 - i 210 - 200 - 1 1 ► 5 10 TIME (SECONDS) FIGURE 11 . RECOMMENDED TIME AND SOLDER TEMPERATURE To ensure that there is no leeching of the silver electrode on the varistor, solders with at least 2% silver content are recommended (62 Sn / 36 Pb / 2 Ag). Examples of silver bearing solders and their associated melting temperatures are per Table 4. TABLE 4. SILVER BEARING SOLDERS (ALPHA METALS) ALLOY MELTING TEMPERATURE °F °C 62Sn/36Pb/2Ag 355 179 96.5Sn/3.5Ag 430 221 95Sn/5Ag 430 - 473 221 - 245 20Sn/88Pb/2Ag 514 - 576 268 - 302 FIGURE 10. LAND PAD PATTERNS FOR MULTILAYER SUPPRESSORS Soldering Methods There are a number of different soldering techniques used in the surface mount process. The most common soldering processes are infra red reflow, vapor phase reflow and wave soldering. For the Harris surface mount suppressor range, the solder paste recommended is a 62/36/2 silver solder. While this configuration is best, other silver solder pastes can also be used. In all soldering applications, the time at peak tempera- ture should be kept to a minimum. Any temperature steps 12-63 process, care should be taken to ensure that the chip is never subjected to a thermal gradient of greater than +4°C per second; the ideal gradient being +2°C per second. For optimum soldering, preheating to within +100°C of the peak soldering temperature is recommended; with a short dwell at the preheat temperature to help minimize the possibility of thermal shock. The dwell time at this preheat temperature should be for a time greater than 10T 2 seconds, where T is the chip thickness in millimeters. Once the soldering process has been completed, it is still necessary to protect against further effects of thermal shocks. One possible cause of thermal shock at the post solder stage is when the hot printed circuit boards are removed from the solder bath and immediately subjected to cleaning solvents at room temper- ature. To avoid this thermal shock affect, the boards must first be allowed to cool to less than +50°C prior to cleaning. Two different resistance to solder heat tests are routinely performed by Harris Semiconductor to simulate any possible effects that the high temperatures of the solder processes may have on the surface mount chip. These tests consist of the complete immersion of the chip in to a solder bath at +260°C for 5 seconds and also in to a solder bath at +220°C for 10 seconds. These soldering conditions were chosen to replicate the peak temperatures expected in a typical wave soldering operation and a typical reflow operation. Reflow Soldering There are two major reflow soldering techniques used in SMT today: 1. InfraRed (IR) Reflow 2. Vapor Phase Reflow The only difference between these two methods is the process of applying heat to melt the solder. In each of these methods precise amounts of solder paste are applied to the circuit board at points where the component terminals will be located. Screen or stencil printing, allowing simultaneous application of paste on all required points, is the most com- monly used method for applying solder for a reflow process. Components are then placed in the solder paste. The solder pastes are a viscous mixture of spherical solder powder, thixotropic vehicle, flux and in some cases, flux activators. During the reflow process, the completed assembly is heated to cause the flux to activate, then heated further, causing the solder to melt and bond the components to the board. As reflow occurs, components whose terminations displace more weight, in solder, than the components weight will float in the molten solder. Surface tension forces work toward establishing the smallest possible surface area for the molten solder. Solder surface area is minimized when the component termination is in the center of the land pad and the solder forms an even fillet up the end termination. Provided the boards pads are properly designed and good wetting occurs, solder surface tension works to center com- ponent terminations on the boards connection pads. This centering action is directly proportional to the solder surface tension. Therefore, it is often advantageous to engineer surface tension in wave soldering. In designing a reflow temperature profile, it is important that the temperature be raised at least 20°C above the melting or liquidus temperature to ensure complete solder melting, flux activation, joint formation and the avoidance of cold melts. The time the parts are held above the melting point must be long enough to alloy the alloy to wet, to become homoge- nous and to level, but not enough to cause leaching of solder, metallization or flux charring. A fast heating rate may not always be advantageous. The parts or components may act as heat sinks, decreasing the rate of rise. If the coefficients of expansion of the substrate and components are too diverse or if the application of heat is uneven, fast breaking or cooling rates may result in poor solder joints or board strengths and loss of electrical conduc- tivity. As stated previously, thermal shock can also damage components. Very rapid heating may evaporate low boiling point organic solvents in the flux so quickly that it causes solder spattering or displacement of devices. If this occurs, removal of these solvents before reflow may be required. A slower heating rate can have similar beneficial effects. InfraRed (IR) Reflow InfraRed (IR) reflow is the method used for the reflowing of solder paste by the medium of a focused or unfocused infra red light. Its primary advantage is its ability to heat very localized areas. The IR process consists of a conveyor belt passing through a tunnel, with the substrate to be soldered sitting on the belt. The tunnel consists of three main zones; a non-focused preheat, a focused reflow area and a cooling area. The unfocused infrared areas generally use two or more emitter zones, thereby providing a wide range of heating profiles for solder reflow. As the assembly passes through the oven on the belt, the time/temperature profile is controlled by the speed of the belt, the energy levels of the infrared sources, the distance of the substrate from the emitters and the absorptive qualities of the components on the assembly. The peak temperature of the infrared soldering operation should not exceed 220°C. The rate of temperature rise from the ambient condition to the peak temperature must be carefully controlled. It is recommended that no individual temperature step is greater than 80°C. A preheat dwell at approximately 150°C for 60 seconds will help to alleviate potential stresses resulting from sudden temperature changes. The temperature ramp up rate from the ambient condition to the peak temperature should not exceed 4°C per second; the ideal gradient being 2°C per second. The dwell time that the chip encounters at the peak temperature should not exceed 10 seconds. Any longer exposure to the peak temperature may result in deterioration of the device protection properties. Cooling of the substrate assembly after solder reflow is complete should be by natural cooling and not by forced air. The advantages of IR Reflow are its ease of setup and that double sided substrates can easily be assembled. Its biggest 12-64 Application Note 9312 disadvantage is that temperature control is indirect and is dependent on the IR absorption characteristics of the component and substrate materials. On emergence from the solder chamber, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the IR reflow soldering process is as Figure 12 and Table 5. FIGURE 12. TYPICAL TEMPERATURE PROFILE FOR IR RE- FLOW SOLDER PROCESS TABLE 5. RECOMMENDED TEMPERATURE PROFILE INFRARED (IR) REFLOW TEMPERATURE (°C) TIME (SECONDS) 25-60 60 60-120 60 120-155 30 155-155 60 155-220 60 220-220 10 220-50 60 contact with the colder parts of the substrate and then condenses. In this process all cold areas are heated evenly and no areas can be heated higher than the boiling point of the solvent, thus preventing charring of the flux. This method gives a very rapid and even heating affect. Further advantages of vapor phase soldering is the excellent control of temperature and that the soldering operation is performed in an inert atmosphere. The liquids used in this process are relatively expensive and so, to overcome this a secondary less expensive solvent is often used. This solvent has a boiling temperature below 50°C. Assemblies are passed through the secondary vapor and into the primary vapor. The rate of flow through the vapors is determined by the mass of the substrate. As in the case of all soldering operations, the time the components sit at the peak temperature should be kept to a minimum. In the case of Harris surface mount suppressors a dwell of no more than 10 seconds at 222°C is recommended. On emergence from the solder system, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the vapor phase soldering process is as Figure 13 and Table 6. Vapor Phase Reflow Vapor phase reflow soldering involves exposing the assem- bly and joints to be soldered to a vapor atmosphere of an inert heated solvent. The solvent is vaporized by heating coils or a molten alloy, in the sump or bath. Heat is released and transferred to the assembly where the vapor comes in i i i i i i r 15 20 25 30 35 40 45 TIME (SECONDS) FIGURE 13. TYPICAL TEMPERATURE PROFILE FOR VAPOR PHASE REFLOW SOLDERING TABLE 6. RECOMMENDED TEMPERATURE PROFILE INFRARED (IR) REFLOW TEMPERATURE (°C) TIME (SECONDS) 25-90 8 90-150 13 150-222 3 222-222 10 222-80 7 80-25 10 12-65 Application Note 9312 Wave Solder This technique, while primarily used for soldering thru hole or leaded devices inserted into printed circuit boards, has also been successfully adapted to accommodate a hybrid technology where leaded, inserted components and adhesive bonded surface mount components populate the same circuit board. The components to be soldered are first bonded to the substrate by means of a temporary adhesive. The board is then fluxed, preheated and dipped or dragged through two waves of solder. The preheating stage serves many functions. It evaporates most of the flux solvent, increases the activity of the flux and accelerates the solder wetting. It also reduces the magnitude of the temperature change experienced by the substrate and components. The first wave in the solder process is a high velocity turbu- lent wave that deposits large quantities of solder on all wettable surfaces it contacts. This turbulent wave is aimed at solving one of the two problems inherent in wave soldering surface mount components, a defect called voiding (i.e. skipped areas). One disadvantage of the high velocity turbu- lent wave is that it gives rise to a second defect known as bridging, where the excess solder thrown at the board by the turbulent wave spans between adjacent pads or circuit elements thus creating unwanted interconnects and shorts. The second, smooth wave accomplishes a clean up operation, melting and removing any bridges created by the turbulent wave. The smooth wave also subjects all previous soldered and wetted surfaces to a sufficiently high tempera- ture to ensure good solder bonding to the circuit and component metallizations. In wave soldering, it is important that the solder have low surface tension to improve its surface wetting characteristics. Therefore, the molten solder bath is maintained at temperatures above its liquid point. On emergence from the solder wave, cooling to ambient should be allowed to occur naturally. Natural cooling allows a gradual relaxation of thermal mismatch stresses in the solder joints. Forced air cooling should be avoided as it can induce thermal breakage. The recommended temperature profile for the wave solder- ing process is as Table 7. TABLE 7. RECOMMENDED TEMPERATURE PROFILE WAVE SOLDER TEMPERATURE (°C) TIME (SECONDS) 25-125 60 125-180 60 180-260 60 260-260 5 260-180 60 180-80 60 80-25 60 Cleaning Methods and Cleaning Fluids The objective of the cleaning process is to remove any contamination, from the board, which may affect the chemical, physical or electrical performance of the circuit in its working environment. There are a wide variety of cleaning processes which can be used, including aqueous based, solvent based or a mixture of both, tailored to meet specific applications. After the sol- dering of surface mount components there is less residue to remove than in conventional through hole soldering. The cleaning process selected must be capable of removing any contaminants from beneath the surface mount assemblies. Optimum cleaning is achieved by avoiding undue delays between the cleaning and soldering operations; by a minimum substrate to component clearance of 0.15mm and by avoiding the high temperatures at which oxidation occurs. Harris recommends 1,1,1 trichloroethane solvent in an ultrasonic bath, with a cleaning time of between two and five minutes. Other solvents which may be better suited to a particular application and can also be used may include those outlined in Table 8. TABLE 8. CLEANING FLUIDS Water Acetone Isopropyl Alcohol Fluorocarbon 113 Fluorocarbon 1 13 Alcohol N-Butyl 1,1,1, Trichloroethane Trichloroethane Toluene Methane Comparison to Other Device Technologies There are many design considerations involved when selecting the correct transient suppressor for an automotive application. One obvious consideration is cost. Other factors such as load dump energy capability, clamping voltage, temperature dependance, and size must also be weighed. Each of these factors will now be discussed. Energy Capability The large active electrode area available to the AUML suppressor ensures that load dump energy handling capabil- ity is one of it's best features. By virtue of its interdigitated construction, the AUML suppressor is capable of dissipating significant amounts of energy over a very small volume of material. The interdigitated construction also ensures that the very high temperatures resulting from a load dump transient will be evenly dissipated through millions of P-N junctions. Silicon surge suppressors may also be used for the suppres- sion of transients in an automotive environment. In the case of a silicon suppressor, only one P-N junction is available to handle the energy of the load transient. It should be noted that many different materials, with varying thermal coeffi- cients of expansion, are employed in the construction of a 12-66 Application Note 9312 silicon suppressor. This may result in extreme thermal stresses being created in the body of the suppressor during a load dump condition. In an attempt to overcome this weakness, a number of silicon die are placed in series in a sandwich construction, with a metal header to act as a heat sink and solder pellets for bonding (Figure 14). HEADER SOLDER PELLET SILICON DIE FIGURE 14. TYPICAL INTERNAL CONSTRUCTION OF A SILICON SUPPRESSOR This construction is designed to distribute the transient energy through more than one P-N junction, and somewhat helps to alleviate the steep temperature build up during the transient. Even with this metal sandwich, the silicon suppres- sor is not completely effective in handling transient pulses. This is because of the thermal time constant involved in transporting the energy (heat) from where it is generated (the silicon die) to the metal heat sink. Even though high energy load dump transients are much less frequent than low energy ones, it takes only one such transient to completely damage the transient suppressor and hence the component or circuit being protected. Comparing the typical peak current, energy and power derating curves of the Harris multilayer to an equivalent silicon suppressor at +125°C, the AUML has 100% of rated value while the zener diode has only 35% (Figure 15). HARRIS MULTI-LAYER SILICON SUPPRESSOR i 1 1 r 50 100 150 200 TEMPERATURE (°C) Clamping Voltage In the majority of automotive applications, the maximum clamping voltage requirement for the primary surge suppres- sor is 40V at 40A (8/20us current waveform). Both the AUML and silicon suppressors easily meet this requirement. The V-l characteristic for a silicon diode is defined over a small current range (1 decade). The AUML current range is extended over a few more decades, which illustrates it's large peak current and energy handling capability. Temperature Effects Both the AUML and the silicon diode have a temperature dependance with respect to off state leakage current - leak- age current increases as temperature increases. However, beyond the breakdown point, the clamping voltage of the AUML will remain constant between +25°C and +125°C, while the clamping voltage for the zener diode at +125°C is higher than that specified at +25°C. Size Up to now, the only surface mounted surge suppressors available are leaded gull-wing and j-bend silicon diodes or a relatively large surface mount metal oxide varistor. In both of these cases a large area of the PC board is needed for mount down. As previously mentioned, electrically equiva- lent AUML suppressors are as much as three to four times as small than their silicon counterparts, resulting in signifi- cant surface mount PC board area savings (Figure 16). TOSHIBA DIODE /.5A5A2/ MOTOROLA DIODE MR2525I I 1 17 0.563 0.118 L»- 0.660-*-) HARRIS AUML2220 FIGURE 16. SIZE COMPARISONS OF AUTOMOTIVE SURGE SUPPRESSORS The compact size of the AUML suppressor is obtained by the paralleled stacking manufacturing process. This results in a high density energy absorber where the device volume is not taken up by lead frames, headers, external leads, and epoxy. Additional board area savings are also realized with the smaller solder mounting area required by the AUML. FIGURE 1 5. AUML AND SILICON SUPPRESSORS CURRENT, ENERGY AND POWER DERATING CURVE 12-67 Maximum Continuous DC Working Voltage (V M(DC) ): This is the maximum continuous dc voltage which may be applied, up to the maximum operating temperature (+125°C), to the AUML suppressor. This voltage is used as the reference test point for leakage current and is always less than the breakdown voltage of the device. Load Dump Energy Rating (W| d ): A load dump occurs when the alternator load is suddenly reduced. The worst case load dump is caused by disconnecting a discharged battery when the alternator is running at full load. The load dump energy discharge occurs with the rated battery voltage also applied and must not cause device failure. This pulse can be applied to the AUML suppressor in either polarity. Maximum Clamping Voltage (V c ): This is the peak voltage appearing across the AUML suppressor when measured with an 8/20us pulse current (Figure 17). 8ms = T, = FRONT TIME 20|is = T 2 = TIME TO HALF VALUE FIGURE 17. Leakage Current (l L ): This is the amount of current drawn by the AUML suppressor in its non-operational mode, i.e. when the voltage applied across the AUML does not exceed the rated V M(DC) voltage of the device. Nominal Voltage (V N(DC) ): This is the voltage at which the AUML enters its conduction state and begins to suppress transients. In the automotive environment this voltage is defined at the 10mA point and has a minimum and maxi- mum voltage specified. References [1] Electromagnetic Susceptibility Measurement Procedures for Vehicle Components - SAE J 1 1 1 3, August, 1987. [2] Harris Semiconductor Application Note AN9002. [3] Transient Voltage Suppression Devices, Harris Semiconductor DB450. [4] "Transient Suppression in the Automotive Environment", Corbett, M. and McCambridge, P., Automotive Electronic Design, October, 1991. [5] Harris Semiconductor Application Note AN9108. [6] CANE SMT 2588, Syfer Technology Limited, UK. 12-68 TVS HIGH RELIABILITY SERIES PAGE HIGH RELIABILITY VARISTORS 13-3 High Reliability Series Mechanical and Environmental Testing for Aerospace, Military and High Reliability Applications . 13-3 DESC Qualified Parts List (QPL) MIL-R-83530 13-3 MIL-R-83530 Inspections 13-4 DESC Standard Military Drawing # 87063 13-5 DESC Standard Military Drawing # 90065 13-7 Harris High Reliability Series TX Equivalents 13-7 Custom Types 13-9 Radiation Hardness 13-9 HIGH RELIABILITY PROTECTION ARRAY DATA SHEET SP720MD-8, High Reliability Electronic Protection Array for ESD and Overvoltage Protection 13-11 SP720MD, SP720MM-8, SP720MM m v> < UJ J t£ 111 UJ DC CO X a x 13-1 hJinh Daliafoilitif X/ot-ict/M-c iign rieiiaDiiiiy vansiors High Reliability Series Mechanical and Environmental Testing for Aerospace, Military and High Reliability Applications The high reliability Harris varistor is the latest step in increased product performance, and is available for applications requiring quality and reliability assurance levels consistent with military or other standards. (MIL-STD-19500, MIL-S-750, Method 202). Additionally, Harris varistors are inherently radiation hardened compared to silicon diode suppressors as illustrated in Figure 1 . This series of high-reliability varistors involve five categories: • DESC Qualified Parts List (QPL) MIL-R-83530 4 types presently available • DESC Standard Military Drawings based on MIL-R-83530 63 types presently available: - ZA Series - Drawing #87063 - DB Series - Drawing #90065 • Harris high reliability series offers TX equivalents 29 types presently available • Custom types processed to customer-specific require- ments - (SCD) or to standard military flow • SP720 - High Reliability Electronic Protection Array Credentials Harris varistors and quality mai • DESC approved • QPL listed • CECC approved • ISO approved • UL approved • CSA approved DESC Qualified Parts List (QPL) MIL-R-83530 TABLE 1. MIL-R-83530/1 RATINGS AND CHARACTERISTICS PART NUMBER M 83 530/ NOMINAL VARISTOR VOLTAGE (V) TOLERANCE (%) VOLTAGE RATING (V) ENERGY RATING (J) CLAMPING VOLTAGE AT 100 A (V) CAPACITANCE AT 1 MHz (PF) CLAMPING VOLTAGE AT PEAK CURRENT RATING (V) Itm (A) NEAREST COMMERCIAL EQUIVALENT (RMS) (DC) 1-2000B 200 ±10 130 175 50 325 3800 570 6000 V130LA20B 1-2200D 220 +10, -5 150 200 55 360 3200 650 6000 V150LA20B 1-4300E 430 +5, -10 275 369 100 680 1800 1200 6000 V275LA40B 1-5100E 510 +5, -10 320 420 120 810 1500 1450 6000 V320LA40B This series of varistors are screened and conditioned in accordance with MIL-R-83530 as outlined in Table 2. Manufacturing system con- forms to MIL-l-45208; MIL-Q-9858. 13-3 High Reliability Series — -R-83530 Inspections TABLE 2. MIL-R-83530 GROUP A, B, AND C INSPECTI INSPECTION AQL (PERCENT DEFECTIVE) MAJOR MINOR NUMBER OF SAMPLE UNITS FAILURES ALLOWED Group A SUBGROUP 1 High Temperature Life (Stabilization Bake) 100% Thermal Shock 100% Power Bum-In 100% Clamping Voltage 100% Nominal Varistor Voltage 100% SUBGROUP 2 Visual and Mechanical Examination 1.0% AQL 7.6% LQ 25% AQL 13.0% LQ Per Plan Body Dimensions Per Plan Diameter and Length of Leads Per Plan Marking Per Plan Workmanship Per Plan SUBGROUP 3 Solderability I Per Plan Group B SUBGROUP 1 Dielectric Withstanding Voltage Per Plan SUBGROUP 2 Resistance to Solvents Per Plan SUBGROUP 3 Terminal Strength (Lead Fatigue) Per Plan Moisture Resistance Per Plan Peak Current Per Plan Energy Per Plan Group C EVERY 3 MONTHS High Temperature Storage 10 Operating Life (Steady State) 10 Pulse Life 10 Shock 10 Vibration 10 Constant Acceleration 10 Energy 10 13-4 High Reliability Series DESC Standard Military Drawing # 87063 Based on MIL-R-83530 TABLE 3. ZA SERIES RATINGS AND SPECIFICATIONS MAXIMUM RATINGS (+85°C) SPECIFICATIONS (+25°C) CONTINUOUS TRANSIENT MAXIMUM CLAMPING VOLTAGE V c AT TEST CURRENT (8/20|is) RMS DC ENERGY (10/ 1000ns) PEAK CURRENT (8/20tis) VARISTOR VOLTAGE AT 1 m A Dc TEST CURRENT TYPICAL CAPACITANCE S7063 DASH NO. NEAREST COMM. NO. (NOTE 1) V M(AC) V M(DC) w TM 'tm MIN V N(DC) MAX v c ■c f = 1MHz SIZE (V) (V) (J) (A) (V) (V) (V) (V) (A) (PF) 001 V22ZA05 1 14 18 0.2 35 18.7 22 26 51 2 400 002 V22ZA1 2 14 18 0.9 150 18.7 22 26 47 5 1600 003 V22ZA2 3 14 18 2.0 350 18.7 22 26 43 5 4000 004 V22ZA3 4 14 18 4.0 750 18.7 22 26 43 10 9000 005 5 14 18 6.5 1500 19.2 24 (Note 2) 26 43 20 18000 006 V27ZA05 1 17 22 0.25 35 23 27 31.1 59 2 300 007 V27ZA1 2 17 22 1.0 150 23 27 31.1 57 5 1300 008 V27ZA2 3 17 22 2.5 350 23 27 31.1 53 5 3000 009 V27ZA4 4 17 22 5.0 750 23 27 31.1 53 10 7000 010 V27ZA60 5 17 22 8.0 1500 23 27 (Note 2) 31.1 50 20 15000 01 1 \/O07AnC VdoZAOo 1 20 26 0.3 35 29.5 33 38 67 2 250 012 V33ZA1 2 20 26 1.2 150 29.5 33 36.5 68 5 1100 01 3 \/QQ"7AO V 00£J\£. 3 20 26 3.0 350 29.5 33 36.5 64 5 2700 014 V33ZA5 4 20 26 6.0 750 29.5 33 36.5 64 10 6000 015 5 21 27 9.0 1500 29.5 33 (Note 2) 36.5 58 20 13000 016 V362A80 5 23 31 10.0 1500 32 36 (Note 2) 40 63 20 12000 017 V39ZA05 1 25 31 0.35 35 35 39 46 79 2 220 018 V39ZA1 2 25 31 1.5 150 35 39 43 79 5 900 019 V39ZA3 3 25 31 3.5 350 35 39 43 76 5 2200 020 V39ZA6 4 25 31 7.2 750 35 39 43 76 10 5000 021 V47ZA05 1 30 38 0.4 35 42 47 200 022 V47ZA1 2 30 38 1.8 150 42 47 52 92 5 800 023 V47ZA3 3 30 38 4.5 350 42 47 52 89 5 2000 024 V47ZA7 4 30 38 8.8 750 42 47 52 89 10 4500 025 V56ZA05 1 35 45 0.5 35 50 56 66 108 2 180 13-5 87063 DASH NO. NEAREST COMM. NO. (NOTE 1 ) SIZE CONTINUOUS TRANSIENT VARISTOR VOLTAGE AT 1 m A DC TEST CURRENT MAXIMUM CLAMPING VOLTAGE V c AT TEST CURRENT (8/20tis) TYPICAL CAPACITANCE RMS DC ENERGY (10/ 1000 t .s) PEAK CURRENT (8/20ns) V M(AC) V M(DC) w TM >TM MIN V N(DC) MAX v c 'c f = 1MHz (V) (V) (J) (A) (V) (V) (V) (V) (A) (pF) 026 V56ZA2 2 35 45 2.3 150 50 56 62 107 5 700 027 V56ZA3 3 35 45 5.5 350 50 56 62 103 5 1800 028 V56ZA8 4 35 45 10.0 750 50 56 62 103 10 3900 029 V68ZA05 1 40 56 0.6 35 61 68 80 127 2 150 030 V68ZA2 2 40 56 3.0 150 61 68 75 127 5 600 031 V68ZA3 3 40 56 6.5 350 61 68 75 123 5 1500 032 V68ZA10 4 40 56 13.0 750 61 68 75 123 10 3300 033 V82ZA05 1 50 66 1.2 70 73 82 97 145 2 120 034 V82ZA2 2 50 66 3.5 300 73 82 91 135 10 500 035 V82ZA4 3 50 66 7.3 750 73 62 91 135 25 1100 036 V82ZA12 4 50 66 13.0 1500 73 82 91 145 50 2500 037 V100ZA05 1 60 81 1.5 70 90 100 117 175 2 90 038 V100ZA3 2 60 81 4.3 300 90 100 110 165 10 400 039 V100ZA4 3 60 81 8.9 750 90 100 110 165 25 900 040 V100ZA15 4 60 81 16.0 1500 90 100 110 175 50 2000 041 V120ZA05 1 75 102 1.8 100 108 120 138 205 2 70 042 V120ZA1 2 75 102 5.3 400 108 120 132 205 10 300 043 V120ZA4 3 75 102 11.0 1000 108 120 132 200 25 750 044 V120ZA6 4 75 102 19.0 2000 108 120 132 210 50 1700 045 V150ZA05 1 92 127 2.3 100 135 150 173 240 2 60 046 V150ZA1 2 95 127 6.5 400 135 150 165 250 10 250 047 V150ZA4 3 95 127 13.0 1000 135 150 165 250 25 600 048 V150ZA8 4 95 127 23.0 2000 135 150 165 255 50 1400 049 V180ZA05 1 110 153 2.7 150 162 180 207 290 2 50 050 V180ZA1 2 115 153 7.7 500 162 180 198 295 10 200 051 V180ZA5 3 115 153 16.0 1500 162 180 198 300 25 500 052 V180ZA10 4 115 153 27.0 3000 162 180 198 300 50 1100 NOTES: 1. Size 1-5mm, 2-7mm. 3-10mm, 4-14mm, 5-20mm 2. 1 0mA DC test current. 13-6 High Reliability Series DESC Star Based on MIL-R-83530 TABLE 4. DB SERIES RATINGS AND SPECIFICATIONS 90065 DASH NO. VOLTAGE RATING MAX. (RMS) ENERGY MAX (J) PEAK CURRENT (A) NOMINAL VARISTOR VOLTAGE (V) MAX CLAMPING VOLTAGE AT TEST CURRENT TYPICAL CAPACITANCE (pF) (V) (I) 012 130 170 22500 200 +28, -16 345 200 10000 013 150 200 22500 240 +28 405 200 8000 014 250 270 22500 390 +39, -36 650 200 5000 015 275 300 22500 430 ±43 730 200 4500 016 320 350 22500 510 +29, -48 830 200 3800 017 420 460 28800 680 +68, -70 1130 200 3000 018 480 510 28800 750 +74, -80 1240 200 2700 019 510 550 28800 820 +91 , -85 1350 200 2500 020 575 600 28800 910 +95, -105 1480 200 2200 021 660 690 28800 1050 ±110 1720 200 2000 022 750 810 28800 1200 ±120 2000 200 1800 Harris High Reliability Series TX Equivalents TABLE 5. AVAILABLE TX MODEL TYPES TX MODEL MODEL SIZE DEVICE MARK NEAREST COMMERCIAL EQUIVALENT V8ZTX1 7mm 8TX1 V8ZA1 V8ZTX2 10mm 8TX2 V8ZA2 V12ZTX1 7mm 12TX1 V12ZA1 V12ZTX2 10mm 12TX2 V12ZA2 V22ZTX1 7mm 22TX1 V22ZA1 V22ZTX3 14mm 22TX3 V22ZA3 V24ZTX50 20mm 24TX50 V24ZA50 V33ZTX1 7mm 33TX1 V33ZA1 V33ZTX5 14mm 33TX5 V33ZA5 V33ZTX70 20mm 33TX70 V33ZA70 V68ZTX2 7mm 68TX2 V68ZA2 V68ZTX10 14mm 68TX10 V68ZA10 V82ZTX2 7mm 82TX2 V82ZA2 V82ZTX12 14mm 82TX12 I 1 V82ZA12 TX MODEL MODEL SIZE DEVICE MARK NEAREST COMMERCIAL EQUIVALENT V130LTX2 V130LTX10A V130LTX20B 7mm 14mm 20mm 130TX 130TX10 130TX20 V130LA2 V130LA10A V130LA20A V150LTX2 V150LTX10A V150LTX20B 7mm 14mm 20mm 150TX 150TX10 150TX20 V150LA2 V150LA10A V150LA20B V250LTX4 V250LTX20A V250LTX40B 7mm 14mm 20mm 250TX 250TX20 250TX40 V250LA4 V250LA20A V250LA40B V420LTX20A V420LTX40B 14mm 20mm 420TX20 420TX40 V420LA20A V420LA40B V480LTX40A V480LTX80B 14mm 20mm 480TX40 480TX80 V480LA40A V480LA80B V510LTX40A V510LTX80B 14mm 20mm 510TX40 510TX80 V510LA40A V510LA80B 13-7 High Reliability Series The TX series of varistors are 100% screened and conditioned in accordance with MIL-STD-750. Tests are as outlined in Table 6. INSPECTION LOTS FORMED AFTER ASSEMBLY LOTS PROPOSED 100% SCREENING REVIEW OF DATA TX PREPARATION FOR DELIVERY OA ACCEPTANCE SAMPLE PER APPLICABLE DEVICE SPECIFICATION FOR TX TYPES TABLE 6. TX EQUIVALENTS SERIES 100% SCREENING SCREEN MIL-STD-750 METHOD CONDITION TX REQUIREMENTS High Temperature Life (stabilization bake) 1032 24 hours min. at max. rated storage temperature. 100% Thermal Shock {temperature cycling) 1051 No dwell is required at 25°C. Test condition A1 , 5 cycles •55°C to +125 °C (extremes). >10 minutes 100% Humidity Life 85°C, 85% R.H., 168 hours. 100% Interim Electrical Vn(qc) Vc (Note 1) As specified, but including delta parameter as a mini- mum. 100% Screen Power Bum-In 1038 Condition B, 85°C, Rated V M(AC) , 72 hours min 100% Final Electrical +V N(DC) V c (Notel) As specified — All parameter measurements must be completed within 96 hours after removal from burn-in conditions. 100% Screen External Visual Examination 2071 To be performed after complete marking. 100% NOTE: 1 . Delta Parameter - V N / D q Maximum allowable shift ±1 0% Max. Applicable lot PDA - 10% Max. Peak current and energy ratings are derated by 10% and 30%, respectively, from standard parts. TABLE 7. QUALITY ASSURANCE ACCEPTANCE TEST MIL-STD-105 LTPD LEVEL AQL Electrical (Bidirectional) Vn(oc), (Per specifications table) II 0.1 Dielectric Withstand Voltage MIL-STD-202, Method 301 , 2500V min. at 1 .0^Ao C 15 Solderability MIL-STD-202, Method 208, no aging, non-activated 15 13-8 High Reliability Series Custom Types In addition to our comprehensive high-reliability series as Additional mechanical and referenced above, Harris can screen and condition to defined in Table 8. customer-specific requirements. TABLE 8. MECHANICAL AND ENVIRONMENTAL CAPABILITIES (TYPICAL CONDITIONS) TEST NAME TEST METHOD DESCRIPTION Terminal Strength MIL-STD-750-2036 3 Bends, 90° Arc, 16oz. Weight Drop Shock MIL-STD-750-2016 1500g's, 0.5ms, 5 Pulses, X,, V 1 , Z, Variable Frequency Vibration MIL-STD-750-2056 20g's, 100-2000Hz, X,, V,, Z, Constant Acceleration MIL-STD-750-2006 V 2 , 20,000g's Min Salt Atmosphere MIL-STD-750-1041 35°C. 24 hrs, 10-50g/m 2 Day Soldering Heat/Solderability MIL-STD-750-2031/2026 260°C, 10s, 3 Cycles, Test Marking Resistance to Solvents MIL-STD-202-215 Permanence, 3 Solvents Flammability MIL-STD-202-111 1 5s Torching, 1 0s to Flameout Flammability UL1414 3 x 15s Torching Cyclical Moisture Resistance MIL-STD-202-106 1 Days Steady-State Moisture Resistance 85/85 96 Hrs. Biased Moisture Resistance Not Recommended for High-Voltage Types Temperature Cycle MIL-STD-202-107 -55°Cto+125°C, 5 Cycles High-Temperature Life (Nonoperating) MIL-STD-750-1032 125°C, 24 Hrs. Bum-In MIL-STD-750-1038 Rated Temperature and V RMS Hermetic Seal MIL-STD-750-1071 Condition D Radiation Hardness For space applications, an extremely important property of a protection device is its response to imposed radiation effects. Electron Irradiation A Harris MOV and a silicon transient suppression diode were exposed to electron irradiation. The V-l Curves, before and after test, are shown in Figure 1 . It is apparent that the Harris MOV was virtually unaffected, even at the extremely high dose of 1 8 rads, while the silicon transient suppression diode showed a dramatic increase in leakage current. I HARRIS MOV I * * * — « SILICON TRANSIENT SUPPRESSION DIODE « 1 ... 10*R 18Me rEST ADS, 1 ELECTRC >NS 10* 10* CURRENT (A) 10= FIGURE 1. RADIATION SENSITIVITY OF HARRIS V130LA1 AND SILICON TRANSIENT SUPPRESSION DIODE 13-9 High Reliability Series Neutron Effects A second MOV-Zener comparison was made in response to neutron fluence. The selected devices were equal in area. Figure 2 shows the clamping voltage response of the MOV and the zener to neutron irradiation to as high as 10 15 N/cm 2 . It is apparent that in contrast to the large change in the zener, the MOV is unaltered. At higher cur- rents where the MOV's clamping voltage is again unchanged, the zener device clamping voltage increases by as much as 36%. AMPERES FIGURE 2. V-l CHARACTERISTIC RESPONSE TO NEUTRON IRRADIATION FOR MOV AND ZENER DIODE DEVICES Counterclockwise rotation of the V-l characteristics is observed in silicon devices at high neutron irradiation levels; in other words, increasing leakage at low current levels and increasing clamping voltage at higher current levels. The solid and open circles for a given fluence represent the high and low breakdown currents for the sample of devices tested. Note that there is a marked decrease in current (or energy) handling capability with increased neutron fluence. Failure threshold of silicon semiconductor junctions is further reduced when high or rapidly increasing currents are applied. Junctions develop hot spots, which enlarge until a short occurs if current is not limited or quickly removed. The characteristic voltage current relationship of a PN-Junc- tion is shown in Figure 3. v FIGURE 3. V-l CHARACTERISTIC OF PN-JUNCTION At low reverse voltage, the device will conduct very little current (the saturation current). At higher reverse voltage V B q (breakdown voltage), the current increases rapidly as the electrons are either pulled by the electric field (Zener effect) or knocked out by other electrons (avalanching). A further increase in voltage causes the device to exhibit a negative resistance characteristic leading to secondary breakdown. This manifests itself through the formation of hotspots, and irreversible damage occurs. This failure threshold decreases under neutron irradiation for zeners, but not for Zinc Oxide Varistors. Gamma Radiation Radiation damage studies were performed on type V130LA2 varistors. Emission spectra and V-l characteristics were collected before and after irradiation with 10 6 rads Co 60 gamma radiation. Both show no change, within experimental error, after irradiation. 13-10 33 SEMICONDUCTOR PRELIMINARY March 1995 SP720MD-8, SP720MD, SP720MM-8, SP720MM High Reliability Electronic Protection Array for ESD and Features • The SP720MD-8 and SP720MM-8 are Harris Class B "Equivalent" Parts with Back-End Conformance to MIL-STD-883 for Final Assembly, Electrical Testing, Burn-In and QC Inspection • ±2A Peak Current Capability • Single-Ended Voltage Range • Differential Voltage Range .to + 35V to ±17.5V • Designed to Provide Over-Voltage Protection • Fast Switching 6ns I • Low Input Leakages of 1 nA at 25°C Typical • Low Input Capacitance of 3pF Typical • An Array of 14 SCR/Diode Pairs • Proven Interface for ESD • Military Temperature Range -55°C to +125°C Applications • Microprocessor/Logic Input Protection • Data Bus Protection • Analog Device Input Protection • Voltage Clamp Description The SP720 is a High Reliability Array of SCR/Diode bipolar structures for ESD and over-voltage protection to sensitive input circuits. The SP720 has 2 protection SCR/Diode device structures at each IN input. A total of 14 available IN inputs can be used to protect up to 14 external signal or bus lines. Over voltage protection is from the IN to V+ or V-. The SCR structures are designed for fast triggering at a thresh- old of one +V BE diode threshold above V+ or at a -V BE diode threshold below V-. From an IN input, a clamp to V+ is acti- vated if a transient pulse causes the input to be increased to a voltage level greater than one V BE above V+. A similar clamp to V- is activated if a negative pulse, one V BE less than V-, is applied to an IN input. The SP720MD-8 and SP720MM-8 Class B "Equivalent" Parts conform to MIL-STD-883 through final assembly, elec- trical test, burn-in and QC Inspection. The SP720MD and SP720MM are High Reliability Ceramic Packaged ICs. Refer to Application Note AN9304 for further information. Ordering Information PART NUMBER TEMPERATURE RANGE PACKAGE SP720MD-8 -55°Cto+125°C 16 Lead Ceramic SBDIP SP720MD -55°Cto+125°C 16 Lead Ceramic SBDIP SP720MM-8 -55°Cto+125°C 20 Pad Ceramic LCC SP720MM -55°Cto+125°C 20 Pad Ceramic LCC Pinouts SP720MD (SBDIP) TOP VIEW SP720MM (CLCC) TOP VIEW IN |T ii] v+ IN \T is] IN IN [3 u| in IN IN [± ijj] IN IN IN [7 IN IN IN [6 U\ IN IN IN ^ io] IN v.[? JJ IN V- Lij uIj lIj iSil l! 8 j A I «J — i *J -_, 6 I i --i 7 I — i — i 8 I 118 i IN Eli IN i — 1 16 M i ps IN I IN U LJ U U_ S o o z S Functional Block Diagram (sp72omd> CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.e. Handling Procedures. pj| e N um ber 3683.1 Copyright © Harris Corporation 1 995 Specifications SP720MD-8, SP720MD, SP720MM-8, Absolute Maximum Ratings Thermal Information Thermal Resistance Bja Bjc Sidebraze DIP Package 82°C/W 14°C/W Ceramic LCC 70°C/W 19°C/W Package Power Dissipation Sidebraze DIP Package, up to +93°C 1 .OW Ceramic LCC, up to +105°C LOW Package Power Dissipation Derating Factor Sidebraze DIP Package, above +93°C 12.2mWV°C Ceramic LCC, above +105°C 14.3mW/°C CAUTION: Stresses above those listed in "Absolute Maximum Ratings - may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Continuous Supply Voltage, [(V+) - (V-)] +35V Input Peak Current, l IN (Non-Repetitive, <1ms) ±2A Max. DC Input Current, l| N ±70mA For ESD Transient Capability - See Note 2, Figure 1, Table 1 Storage Temperature Range -65°C to +150°C Junction Temperature +1 75°C Lead Temperature (Soldering 1 0s) +265°C Operating Conditions Operating Voltage Range, Single Supply +4.5V to +30V Operating Voltage Range, Split Supply ±2.25V to ±15V Typical Quiescent Supply Current 50nA Operating Temperature Range -55°C to +125°C Electrical Specifications T A = -55°C to +1 25°C, Unless Otherwise Specified PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS Operating Voltage Range V SUPPLY VSUPPLY = l(V+) - (V-)] 4.5 to 30 35 V Peak Forward/Reverse Voltage Drop IN to V- (with V- Reference) V IN - (V-) l, N = -1A (1ms Peak Pulse) -2 V IN to V+ (with V+ Reference) V IN - (V + ) l| N = +1 A (1ms Peak Pulse) +2 V DC Forward/Reverse Voltage Drop IN to V- (with V- Reference) V IN - (V-) l, N = -100mA to V- -1.5 V IN to V+ (with V+ Reference) V,n " (V+) l IN = +1 00mA to V+ +1.5 V Input Leakage Current !|N V- < V, N < V+, V SU pp LY = 30V -15 5 +15 nA Quiescent Supply Current 'quiescent V- < V IN < V+, V SUPPLY = 30V 50 150 nA Equivalent SCR ON Threshold Note 3 1.1 V Equivalent SCR ON Resistance VFwryiFwrj(Note3) 1 n Input Capacitance C IN 3 pF Input Switching Speed *ON 6 nS 1 . In automotive and battery operated systems, the power supply lines should be externally protected for load dump and reverse battery. When the V+ and V- pins are connected to the same supply voltage source as the device or control line under protection, a current limiting resistor should be connected in series between the external supply and the SP720 supply pins to limit reverse battery current to within the rated maximum limits. Bypass capacitors of typically 0.01 uF or larger from the V+ and V- pins to ground are recommended. 2. For ESD testing of the SP720 to MIL-STD-883, Method 301 5.7, Human Body Model (HBM), the results are typically better than 6kV (Condition 1 ). Transient and ESD capability is highly dependent on the application. For conditions that are defined as an in-circuit method of ESD testing where the V+ and V- pins have a return path to ground, the ESD capability is typically greater than 15kV from 100pF through 1 .5k£) (Condition 2). For ESD testing of the SP720 to EIAJ IC1 21 Machine Model (MM) standard, the results are typically better than 1kV (Condition 4). These values were measured by AT&T ESD Lab using the component testing procedures of both standards. Additional ESD testing for 200pF through 1 .5kn with 6ns risetime was done with results better than 9kV (Condition 3). 3. Refer to the Figure 3 graph for definitions of equivalent "SCR ON Threshold" and "SCR ON Resistance". These characteristics are given here for thumb-rule information to determine peak current and dissipation under EOS conditions. R, -10M£2 -VvV o Wr H.V. SUPPLY ±v IN DUT FIGURE 1. ELECTROSTATIC DISCHARGE TEST MIL-STD-883D, METHOD 3015.7 TABLE 1. ESD TEST CONDITIONS TEST ±V C D Condition 1 6kV 1.5k£i 100pF (HBM) Condition 2 15kV 1.5kn 100pF (Mod. HBM) Condition 3 9kV 1.5k(2 200pF (Mod. HBM) Condition 4 1KkV own 200pF (MM) 13-12 SP720MD-8, SP720MD, SP720MM-8, SP720MM INPUT DRIVERS OR SIGNAL SOURCES LINEAR OR DIGITAL IC INTERFACE v — IN 1-7 IN 9-15 SP720 INPUT PROTECTION CIRCUIT (1 OF 14 ON CHIP) TO tV cc 1 FIGURE 4. TYPICAL APPUCATION OF THE SP720 AS AN INPUT CLAMP FOR OVER-VOLTAGE, GREATER THAN 1 V BE ABOVE V+ OR LESS THAN -1V BE BELOW V-. PINOUT SHOWN IS FOR THE SP720MD PDIP PACKAGE. 13-13 SP720MD-8, SP720MD, SP720MM-8, SP720MM Power Dissipation Derating Curves o 100 125 AMBIENT TEMPERATURE (°C) 150 175 FIGURE 5. SP720MD DERATING CURVE FOR THE 82°C/W THERMAL RESISTANCE OF THE SIDEBRAZE 16 LEAD CERAMIC PACKAGE, DERATED 12.2mW/°C FROM A MAXIMUM P„ OF LOW AT 93°C 2 i in 0.5 5 MAX. DISSIPATION 105°C MAX. DERATED DISSIPATION 50 100 AMBIENT TEMPERATURE (°C) FIGURE 6. SP720MM DERATING CURVE FOR THE 70°C/W THERMAL RESISTANCE OF THE 20 PAD CERAMIC LCC PACKAGE, DERATED 14.3mW/°C FROM A MAXIMUM P D OF LOW AT 105°C 13-14 SP720MD-8, SP720MD, SP720MM-8, SP720MM SP720MD-8 and SP720MM-8 Dynamic Burn-In Circuits 16 LEAD CERAMIC SBDIP NOTES: t All resistors 1kn ±10% 2. V CO = 30V±1% 3. F s = 0V to 30V +1%, 50% Duty Cycle 4. Cf = 22(iF Min. Tantalum, 50WV (33WV 5. T AMB = 125°C 20 PAD CLCC INPUT SIGNAL • Vcc : C1 — Wv— — Wv— Wv * i i i i I — n — tt L2. j L£J j_ 1 j L??j LtSI 4"! [18 — I !J — I 7 I — i ~-\ 8 I Tie L ri? ■ It* '"ft* 1 r-n r-T r-*i r-T i 9 i 1 1 1 i11 i 1 12 i 1 1 3 1 I . I I LI 11,11, I -vW— 1 -VvV— — vW— OUUl 13-15 SP720MD-8, SP720MD, SP720MM-8, SP720MM Metallization Topology DIE DIMENSIONS: 51 x84x14±1mils METALLIZATION: Type: Al Thickness: 17.5kA±2.5kA GLASSIVATION: Type: SiO z Thickness: 13kA + 2.6kA SUBSTRATE POTENTIAL (POWERED UP): WORST CASE CURRENT DENSITY: 9.18 x 10 4 A/cm 2 at 70mA PROCESS: Metallization Mask Layout SP720MD-8, SP720MD, SP720MM-8, SP720MM 13-16 SP720MD-8, SP720MD, SP720MM-8, SP720MM Ceramic Dual-ln-Line Metal Seal Packages (SBDIP) d LEAD FINISH l f. \ c iviuui ii iticiqi voi ioiui s 01 i vj iviuunayci i lai i sient Voltage Suppressors (ML Series) (8 pages) 99304 AN9304 ESD and Transient Protection Using the SP720 (10 pages) 99306 AN9306 The New "C" III Series of Metal Oxide Varistors (5 pages) 99307 AN9307 The Connector PIN Varistor for Transient Voltage Protection in Connectors (7 pages) Q930R AN9308 Voltsicjs TrsnsiGnts 3nd their Suppression (5 psqgs) 99310 OUI yc OUppi ooolUI 1 I CUl 1 1 I Uiuy Ico r\U Vol 1 lay trb al IU UloaUvdl Itctyco ^IVILJ V i>, O/^Uo, uds 1 UUcb, Filters & Transformers) (6 pages) 99311 AN9311 The ABCs of MOVs (3 pages) 99312 AN9312 Suppression of Transients in an Automotive Environment (11 pages) For more information, see the AnswerFAX map on page 14-2 and choose catalog item #5, "Discrete and Intelligent Power Products". AnswerFAX Gives You the Information You Need. On Your Own Fax. • Data Sheets • Application Notes • New Products • Technical Briefs AnswerFAX provides a full library of information on Harris products at your fingertips 24 hours a day. m HARRIS KMJ SEMICONDUCTOR 407-724-7800 14-4 INDEX AC Bias Reliability 5-11 AC Power Lines, Transients 1-13 Accelerated Humidity Life 5-17 Accelerated Storage Life 5-17 Accelerated Testing 5-13 Acceleration Factor 5-10 AC-DC Difference 7-4 Across the Line Components 7-9 Activation 5-11 Activation Energy 5-11 Aging 2-9 Alpha ..2-5,3-9 Alternator Field Decay 11-5 ANSI 1-18 ANSI Standard 1-18, 1-21, 6-21, 7-12 AnswerFAX 14-1 Application, Examples 6-11, 12-1 Applications, Automotive 11-3, 12-58 Applications, Crowbar 6-19 Applications, Motor Control 6-12 Applications, Motor Protection 6-18 Applications, Noise Suppression 6-15 Applications, Power Supply 6-11 Applications, Relays 6-14, 6-15 Applications, Telecom 10-11 Arcing, Contact 6-15 Arcing, Switch 1-12 Array Protection 9-6 Arrhenius Models 5-12 Assurance Tests 7-8 Asymmetrical Polarity 7-5 Automobile Transients 1-14 Automotive Central Suppressor 11-3, 11-7 Automotive Electrical System 11-4 Automotive Ignition 11-4 Automotive Test Waveforms 11-3 Automotive Transients 1-15,11-5 Avalanche 2-5 Avalanche Diodes 12-52 Axial Lead Metal-Oxide Varistors 4-69 B Branch Circuits 1-22 Break-In Stabilization 7-4 Building Locations 1-22 Buried Cable 10-3 Cable Plant 10-3 Cable Shield 10-3 Cable, Suspended 10-3 Cable Transients 10-4 Capacitance 3-9, 7-7 Capacitance, Stray 1-12 Capacitance, Varistor 2-9, 3-4 Capacitor Clamping 6-14 Carbon Blocks 10-7 Central Office 10-8 Ceramic Structure 3-3 Characteristic Measurement 7-4, 7-10 Characteristics, Electrical 3-6, 3-9 Circuit Models, Varistors 3-6, 3-9 Clamp Ratio 6-6 Clamping 2-3 Clamping Voltage 6-6 Clamping Voltage Measurement 7-5 Clearing Time 6-8 Comparison of Suppressors 2-6 Conductive Shield 10-3 Connector Pin Varistor 2-11 X Ul a 16-1 Conservation, Energy 1-16 Construction, Varistor 3-5 Contact Arcing 6-14, 6-15 Contact Bounce 1-12, 1-15 Contact Welding 1-15 Contacts 1-15 Continuous Power Dissipation 7-9 Continuous Rating 7-8 Creepage Specifications 1-16 Crowbar, Power Supply 6-19 Crowbar Type Suppressors 2-3 Current, Derating 6-5 Current, Peak Rating 6-5, 7-8 D Date Codes 12-56 DC Bias 5-13 DC Power Life 5-13 DC Standby Current 7-7 Degradation, Semiconductor 1-15 Delay Time, Gas Tube 2-6, 2-8 Depletion 3-5 Derating Curves 6-6 DESC Qualified Parts 13-3 Detection of Transients 1-16, 7-10 Dielectric Breakdown 1-16 Disc Diameter 3-6 Disc Thickness 3-4 Dissipation Factor 7-7 DOX 5-5 Dynamic Resistance 3-10 E Effects of Voltage Transients 1-15 Electrical Characteristics 3-6 Electromechanical Contacts 1-12 Electromechanical Switching 1-15 Electronic Ignition 11-7 Encapsulation 3-6 Energy, 60Hz Surge Capability 5-15 Energy Calculations 6-4 Energy Conservation 1-16 Energy, Inductive 1-11 Energy, Pulse 5-15 Energy Rating 6-4, 7-7, 7-8 Energy, Stored. See Stored Energy Energy Waveshape Constants 6-4 Energy Withstand 5-15 Engine Shutdown 1-15 Engineering Evaluation 7-3 Environment 1-19 Environmental Testing 5-17,13-3 Epoxy 3-6 Equipment, Test 7-10 Equivalent Circuit 3-6 F Failure Definition 5-13 Failure Insulation 1-15 Failure Mode 2-9, 6-6 Failure Rate 5-11 Failure, Semiconductor 1-15 Fault Conditions 1-12 FCC Standards 7-12, 7-13 Field Maintenance 7-4 Filters 2-4 Fire Retardant 5-15 Flame Test 5-17, 7-9 Flashover 1-13 Follow Current 2-3, 2-4 Fuse Clearing 6-8 Fusing Example 6-8 Fusing, Varistor 6-8 F.M.E.A 5-9 G Gas Discharge Device 2-6 Gas Tubes 2-4, 12-52 Grain Structure 3-3 Grains 3-3 Ground Currents 10-3 Ground Potential Rise 10-5 H Harris Varistor Properties 3-3 Heavy Metals 12-57 High Reliability Testing 13-3 Humidity Life 5-18 Hybrid Protection 2-9 I A 6-8 Idle Power. See Standby Power IEC Standard 1-18 IEEE Standard 3-11,7-12 16-2 induced iransients iu-4 Inductance, Leads 3-10, 7-6, 12-57 Induction Motor, Stored Energy 6-18 Inductive Load Switching 6-14 Inductive Loads, Transistor Switching 6-16 Inrush Current 1-11 Instrumentation, Transient Detection. See Equipment, Test Insulation 1-15 ISO 9000 5-3,5-7 J Jump Starts 1-14, 11-3 Junction, Grain Boundary 3-3, 3-4 K Kettering Ignition. See Electronic Ignition L Laboratory Instruments 7-10 Lead Length 7-6 Leakage Region 3-9 Life, DC Power 5-14 Life, Humidity. See Humidity Life Life, Storage 5-17 Life Testing 7-8 Lifetime Current Rating 6-5 Lightning 1-19, 6-8, 10-3, 10-8 Lightning Transients 10-5 Load Dump 1-14, 11-3 Load Line 6-5, 6-6 Location Category 1-22 Long Branch Circuits 1-22, 4-7 Loop Area 7-6 M Magnetizing Current 6-13 Manufacturing Sequence 3-5 Matching 6-10 Mean Life 5-12 Measurement of Characteristics 7-4 Measuring Transients 7-10 Mechanical 13-9 Mechanical Reliability 5-15 Mechanical Shock 5-18 Metal Oxide Properties 3-3 ivioior uonuoi o-ii: Motor Protection 6-18 MTTF 5-10 Mutual Coupling 6-14 N Noise Generation 1-16 Noise Suppression 6-15 Nonlinear Resistors 2-5 o Operation, Theory of 3-4 Overshoot Effect 3-11, 7-5, 7-6 P Package Material Expulsion 6-8 Package Photo 3-7 Parallel Operation 6-10 Peak Current Rating 7-8 Peak Current Rating. See Current PFAST 5-6 Phase Connections 4-8 P-N Junction 3-3 Power Circuits (AC) 1-19 Power Consumption 1-16 Power Contact 10-5 Power Cross 10-5 Power Derating 6-6 Power Dissipation Requirements 6-5 Power Induction 10-5 Power Lines (AC) Transients 1-13 Power, Standby 2-6 Power Supply Crowbar. See Crowbar Power Supply Protection 6-11 Power-Follow 2-4 Primary Protection 10-5 Product Family Guide 6-7 Product Qualification 7-3 Product Series, Varistor 4-1 Proof Tests 2-10 Protection Array 9-11 Pulse Current Testing 7-5 Pulse Current Waveform 3-13 Pulse Energy 5-14 Pulse Rating 7-8 X UJ Q Z 16-3 Pulse Rating Curves Quality 5-3 Questions, Common 12-55 R Radiation Hardness 5-19, 13-9 Random Transients 1-13 Rate Effects 3-10 Rate of Rise 1-16 Rating, Assurance. See Assurance Tests Rating, Peak Current. See Current, Peak Rating Rating, Power Dissipation 7-8 Rating Table 6-3 Ratings, Current vs Temperature 6-5, 6-6 RC Network Snubbers 2-4 REA Standard 7-12 Relay Capacitance, Stray 1-12 Relay Switching. See Applications, Relays Reliability 5-3 Reliability, AC Bias 5-11 Reliability, DC Bias 5-13 Reliability, Environmental 5-18 Reliability Model, DC Power Life 5-14 Reliability Terms 5-10 Repeatable Transients 1-11 Response Time 2-8, 3-10 Restrike 1-12 RFI Filter 6-11 S SAE Test Circuits 11-3 Secondary Protection 10-6 Selecting the Varistor 6-3 Selection Guide 6-7, 6-20 Selenium Suppressors 2-5 Semiconductor Degradation 1-15 Semiconductor, Transient Effects 1-15 Series Operation 6-10 Service Entrance 1-22, 4-7 Shock Testing. See Mechanical Short-Circuit Device 5-15 Signal Line Protection. See Array, Protection Silicon Carbide 2-5 2-4, 2-7 SPC 5-7 Specifications Table 6-3 Speed of Response. See Response Time Stability 5-13 Standards 1-18 Standby Power. See Power, Standby Starting Currents 6-18 Static Resistance 3-10 Storage 5-18 Storage Reliability 5-9 Stored Energy 1-12, 6-13, 6-14 Stored Energy, Motor 6-18 Stress Levels 5-14 Suppression Devices 2-3 Suppressors, Avalanche Diodes 2-5 Surface Mount Varistors 2-13, 12-5 Surge Energy (60Hz) Capability. See Energy Surge Impedance 10-4 Surge Testing 7-9 Surge Withstand Capability Standard 7-13 Surge Withstand Capability (SWC) 1-14 SURGECTOR Applications 10-11 SURGECTOR Nomenclature, Packages and Shipping . . 10-10 SURGECTOR Operation 10-8 SURGECTOR Performance Characteristics 10-9 SURGECTOR Product Selection Guide 8-2 Suspended Cable 10-3 Switch Arcing. See Arcing Switching, Contacts 6-14 Switching, Inductive Loads. See Inductive Loads Symmetrical 3-3 T Telecommunication Line Transients 1-14 Telecommunications 10-3, 10-11 Telephone Lines 1-14 Telephone Protection 10-11 Temperature Coefficient 3-9 Temperature Dependence 7-7 Temperature Derating 6-5, 6-6 Temperature Effects 3-9 Terminal Strength 5-18 Terminology. See Varistor Terminology 16-4 Test Objectives 7-3 Test Waveform 3-13 Test Waves 7-10 Testing 2-10, 7-9 Testing, Clamp Voltage. See Clamping Testing, Current Surge 7-10 Testing, DC Standby Current. See DC Testing, Environmental. See Environmental Testing, Field. See Field Maintenance Testing, Mechanical 13-9 Testing, Pulse Energy. See Pulse Energy Testing, Transient Power. See Transient Power Testing, Transients 1-18 Testing, Varistors 7-3 Thermal Runaway 5-11 Thermal Shock 5-18 Thevenin Equivalent Circuit 6-5 Tip and Ring 10-3, 10-6 Training 5-7 Transformer 1-11,6-4,6-13 Transformer Magnetizing Current 1-11 Transient Control Level (TCL) 1-14 Transient Detection. See Detection Transient Effects 1-15 Transient Environment 1-19 Transient Measurements 7-10 Transient Power 7-8 Transient Standards. See Standards Transients, AC Power Lines. See AC Transients, Automotive 1-14, 1-15 Transients, Cable 10-4 Transients, Random. See Random Transients, Repeatable 1-11 Transients, Telecommunication. See Telecommunication Transmission Lines 10-3 Tubular Varistor 2-11 TV Receiver 6-11 U UL Flammability 4-6 UL Recognition 7-9 Underground Cable 10-3 Upturn Region 3-6 Varistor 2 Varistor Basic Properties 3-; Varistor Capacitance. See Capacitance Varistor Construction. See Construction Varistor Fusing 6-8 Varistor Matching. See Matching Varistor Rating 7 Varistor Reliability. See Reliability Varistor Specifications 4-1 Varistor Stability. See Stability Varistor Symbols 3-11 Varistor Terminology 3-11 Varistor Testing 7-3 Varistor Voltage Measurement 7-4 Varistor Voltage Ratings 6-20 Varistors, Metal Oxide 2-6 Vibration 5-18 Vibration Variable 13-9 Voltage 2-6 Voltage Clamping 6-6 Voltage Dependent Device 3-3 Voltage Rating Table 6-3 Volt-Ampere Characteristics 2-3, 2-6, W Waveform, Test. See Test Welding 1-15 Withstand Capabilities 2-9 z Zener Suppressors 2- Zinc Oxide 2-6 16-5 16-6