e CTi, CT2: Controj 1, Control 2 (Output) This is the terminal that is used to control an external device and should read “0” level when at initial condition. e SO: Senal Output (Output) Takes the tone signal divided between the 2 left and night channels, outputs it as serial data, and sends it to the YM3012 D/A converter specially developed for use with the YM2151. e SHI, SH2: Sample and hold Used to pick up the serial data supplied to the YM3012 D/A converter, and for sampling hoid after analog conversion. © 9M: System clock (Input) Inputs the clock 9M that drives the YM2151, which is intermally broken down to and used at 1/2 the frequency. The 9M is the reference for the tone signal. @ $1: Clock for D/A (Output) This clock drives the D/A and operates at the same frequency as the clock inside the YM2151, Also, when the $1 level shifts from “1” to “0”, the iRQ. CTI, CT2, TO. SHI, SH2. and SO signals all change e Voo: Power Supply (Input) Normally supplies at + SV. e ss: Grand (Input) Conects the system grand.