I. DESCRIPTION OF OPERATION All functions of the OPLL are controlled by data written in a register array by the processor. The data specifies the sound envelope shape, the degree of modulation, frequency, and output mode, etc. A complete set of data defines the sound as that of a piano or violin, etc. For the use of complex varieties of data sets see “Synthesis of music sounds”. (III 1) Registers A register comprises an area of 271 bits, as shown in the address map II— 7. The address referred to here is the sub-address assigned to cach register of the OPLL. Musical sound data will be written into a register referred ib by the sub-address. To store a data in the OPLL. we send a sub-address then the sound data. If we access a location having the same sub-address many times, we only have to send the sub-address the first time. In subsequent accesses, we can send sound data alone to renew old data. All registers are cleared to 0 by initialization (initial clear: TC terminal = 0). (Ml-1-1) TEST: ADDRESS [SOF] This address is established to test this LSI. Normally all addresses are 0. (I- 1-2) AM/VIB/EG-TYP/KSR/MULTIPLE : ADDRESS [$00. S01} This register controls the muitiplying factor that converts F-number into the carrier ($01) and modulator ($00) frequencies which matches the sound frequency components, and the envelope shape etc. $00,801 [Ds [Ds [Ds 10.0; 0, 0, De a]? mutt PEtS/S/ Ble oe a oe Do — Ds (MULTIPLE): The frequencies of the carrier wave and the modulated wave are controlled according to the multiplying factors in Table MI—1. F (t) = E sin (ft + [ sin (7 ft)) Frequency according to F-number of Carrier multiple 1 Modulator muitiple 7 -8-