Here's the format of the YM2612 test register ($21), as best as I can tell: bit 7 - If bit 6 set, select 0=LSB, 1=MSB of serial data bit 6 - If set, reading status returns serial data LSB or MSB instead of status flags bit 5 - If set, only the attack phase and possibly decay occur, there is no sustain o release. It sounds like each channel was keyed-on rapidly. When the bit is cleared, the channels resume their original position within the envelope so this bit doesn't have any lasting change on them. bit 4 - Data sent to DAC is inverted - this is *really* loud, so turn down the volume before using this bit. ;) bit 3 - Audio output is muted, (the PSG still works of course) bits 4,5 will make sound faintly audible when set in conjunction. bit 2 - Timer A and B run 24 times faster. bits 1,0 - No effect. Bits 7, 6 allow you to read the serial data sent from the YM2612 to the DAC. (the other chip, YM3012 - not the DAC at $2A/$2B) I'm unsure of the exact format, it's probably similar to the YM2151. Bit 4 inverts the data sent to the DAC, but not the data read from the status register. Compared to the YM2151 test register documented in MAME, the last 3 bits may have something to do with the LFO. And I'm also not entirely sure about the MSB/LSB order for bit 6. Other than that the two work in a mostly identical way. My Notes: bit 7 - Select upper/lower bits of 14-bit output from operator unit to to accumulator. If set, lower bits are read, otherwise upper bits are read. Note that when the upper bits are selected, the lower 6 bits of the 8-bit result contain the upper 6 bits of the 14-bit operator output. The upper 2 bits of the result do return data, but the meaning of that data is currently unknown. bit 6 - Enable output of operator data to status register bit 5 - ? bit 4 - Toggles the "FORM SELECT" (pin 6) input to the DAC bit 3 - Halt Phase Generator. While this bit is set, the phase counter is reset to 0 before each update cycle. This means the phase generator effectively outputs the phase increment value each cycle. By setting up a phase increment which steps a full quarter phase each update cycle, the phase generator can be set to oscillate between minimum and maximum attenuation each step, effectively removing it from the operator unit, and isolating the envelope generator output. bit 2 - Disables the 24 divider for both timers. Both timers run 24 times faster, and timer A runs at the FM clock rate.